Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L1 | Accepted-AOC Successful bidder |
| 2 | L2₹1.8 Cr+₹3.3 L (1.88%)Rejected-AOC | ₹1.8 Cr+₹3.3 L (1.88%) | L2 | Rejected-AOC Unsuccessful bidder |
| 3 | Rejected-Technical 57 RUPNAGAR GUWAHATI PO INDRAPUR PS PALTANBAZAR DIST KAMRP METRO ASSAM PIN 781032 | KAMRUP METRO | ASSAM | 781032 | - | - | Rejected-Technical Technically not qualified |
Tender Value
Refer Docs
EMD Value
₹2.8 L
Closing Date
5 Mar 2021, 2:00 pmClosed
SE Guwahati Building Circle-II Chandmari
SE office Guwahati Building Circle-II Chandmari
Upgradation Modernisation of Landscaping, External Road Development for Ambulance and Beautification at District Hospital Sonapur up to the mark State of Art under SOPD G for the Financial year 2020 21
2021_PWBNH_21515_1
COVID19/SonapurDH/Lanscaping
Open Tender
Civil Works - Building
Item Wise
90 days
Sonapur Kamrup (Metro)
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,190
Assam State Road Board Maintenance (Roads) Fund
₹2.8 L
Yes
SE office Guwahati Building Circle-II Chandmari
15 Jun 2021
26 Feb 2021
6 Mar 2021
26 Feb 2021
5 Mar 2021
26 Feb 2021
1 Mar 2021
Amount
Earth work in Excavation for foundation trenches of walls , Retaining walls, footing of column , steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work , breaking clods in return filling , dressing Watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Upto a depth of 2 mts. below the existing Ground Level In ordinary Soil
Earth /Sand filling in plinth in layers not more than 150 mm thick including necessary carriage , watering , ramming etc. completed and specified including payment of land compensation , forest royalty , sales tax and other duties and taxes as may be necessary. (a) With earth or silt or sand obtained by head load with lead upto 90m and lift upto 2m. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b)Other than Guwahati city only
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
230mm thick brick wall in cement morter with 1st class brick including racking out joints and curing complete as directed in structure (I) In Sub-structure upto plinth level including dewatering if necessary (c). In proportion 1:5.
230mm thick brick wall in cement morter with 1st class brick including racking out joints and curing complete as directed in structure (II) In superstructure above plinth level up to 1st floor level. (b). In proportion 1:4.(1 cement:4 sand)
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement:4 sand)
Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. (a) 112mm thick brick/ R.B wall
Plain cement concrete works with course aggregate of sizes 13mm to 32mm in foundation bed for footing steps, for walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (Shuttering where necessary shall be measured and paid separately) (a) In proportion- 1 cement : 3 sand : 6 coarse aggregates by volume
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. c) 100mm thick
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. c) M25 grade concrete
In super structure from plinth level up to 1st floor level. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. P) Using admixture, plasticiser etc b) M20 grade concrete or Prop. 1:1.5:3 (Playing area floor)
Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.
Providing formwork of ordinary timber planking so as to give a rough finish including centering, shuttering , strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for cast - in - situ reinforced concrete and plain concrete work: In Substructure upto Plinth Level : Foundation, footings, base of columns, pile cap, raft and mass concrete works etc. Using 25mm thick plank
Sides of tie beams, plinth beams, grade beams etc. at or below plinth level Using 25mm thick plank
In Superstructure from Plinth Level upto Floor Level-1: Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.2.1 .
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) b) In cement mortar 1:4
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). c) Delux range Somany/ Orient/Nitco/Varmora Make iv) Of size 300mmx600mm and above
Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). (i) Executive Quality (i) With Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii)Super Ductile (SD) TMT reinforcement bars
Extra over item 18.1.1(a) for each subsequent floor or part thereof 1st floor to 2nd floor level.
Steel work riveted and/ or bolted/ riveted in built up sections, frame work including cutting, hoisting, fixing in position and applying a priming coat of red- lead paint up to 4.6m height above plinth including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. a) In beams and joists with connecting plates/ angle cleats
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) a) For 1.5mm thick application
Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Extra over item no 13.4.7 above for every subsequent coat of wall painting with Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). (i).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Extra over item no 13.4.7 above for painting with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on celling and on sloping roof. (i).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak" brand of required shade by thinning 1ltr. of paint with 750ml of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.
Extra over item no.13.5.2 above for every subsequent coat of acrylic emulsion exterior coatings of Unicem 'Rakshak' brand of required shade.
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (ii).Surfaces up to 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Supplying and planting of suitable plant materials for preparation protective / external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (B) ADOPTING CROSS WISE DOUBLE ROW PLANTING METHOD (i) With Duranta
Supplying and planting of house plants in required size of pot including filling the pot to the top surface with appropriate soil media of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (H) With Iron Cross Begonia (I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
Supplying and planting of palms with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (B) With Erica palm (Butterfly palm)/ Kentia palm (I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
Supplying and planting of suitable plant materials for edge making / Internal hedge(20 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) ADOPTING SINGLE ROW PLANTING METHOD (i) With Duranta
(ii) With Coleus
Supplying and planting of suitable plant materials for edge making / Internal hedge(20 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (B) ADOPTING CROSS WISE DOUBLE ROW PLANTING METHOD (i) With Duranta
(v) With Acer palmatum
Supplying and planting of ornamental trees (1'-0" height sapling) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . SHADE TREE (A) Neem / Mahaneem / Beef wood / Bakul / Acacia / Siris / Devils tree / Kadam / Palash / Pink Cassia / peepal / Silver oak / Simalu / Ajar
(B) Kanchan / Nahar / Arjunu
Supplying and planting of ornamental shrub ( below 1'-0" height ) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (A) Radhachura / Krishnachura / Rat ki rani / Ixora / Jetuka
(B) Allmanda / Khorika zai / May flower / Kamini / Kathanda / Tecoma / Acalypha / Bougainvillea / Dracaena / Togor / Nilakantha / Mussaenda
(D) Thuja
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Spectrum or equivalent as directed by the Departement (iii) 0.50 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Spectrum or equivalent as directed by the Departement (iii) 0.50 mm thick
Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause 401 of MoRTH specifications (with an initial lead of 5 km) (including cost of testing of materials at site and laboratory as directed by the deptt.) (b)Using Grading II material
Providing, laying, spreading and compacting stione aggregates of specific size to water bound mecadam specification including spreading in uniform thickness, hand-packing, rolling with vibratoy roller8-10 tonnes in stages to proper grade and camber, applying and brooming Type -A (13.2 mm agg.) screening/binding material to filled up the interstices of coarse aggregate watering and compacting to the reqd. density( with all initial lead of 5.0 Km) By Manual means Grading II using Screening Type B(11.2mm agg)
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 40 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and Technical specification clause 1504 of MORD.
Providing & Fixing of Aludecor Aluminium Composite Panel cladding & canopy in pan shape in specific color AL33MT 5002 or approved shades made out of 3mm thick aluminium composite panel material consisting 2.5mm LDPE core sandwich between two aluminium sheet of each 0.25mm thick. The Aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF/Lumiflon based fluoro-polymer resin coating of approved color and shade of face #1 and polumer (Service) coating on face #2 as specified using stainless steel screw, nuts, bolts, whether Silicon sealant, backer rods etc along with a Aluminium Tube frame work of size 25X40mm of minimum 0.25mm thick fixed with MS structure. The canopy will be of 300mm height and 1200mm width from the wall of the building. Canopy must be connected from one pillar to another with MS structure as per specification. Light would be fixed to the bottom face of the canopy by cutting as per specified light sizes.
Water Fountain
Water Cascade
Wiring for light/fan/bell point with 2 x 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring with 20 mm dia 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 6 Amps flush type switch/bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover as required complete, when placed elsewhere. Short point upto 3.0 m length
Medium point upto 6.0 m length
Long point upto 10.0 m length
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 3 x 4 sq. mm. + earth continuity with 2x 2.5 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supplying including and fixing of metal boxes in recessed system complete as per direction of department. Legrand/anchor/schneider or equivalent 3 module flush type metal
6 module flush type metal
12 module flush type metal
Supplying including fitting fixing of logic front plate of suitable colour as per direction of department. Legrand/anchor/schneider or equivalent 3 module flush type metal
6 module flush type metal
12 module flush type metal
Supplying with fitting fixing 6 amp one way modular clip in switch in recessed system including making necessary connection complete as per direction of department. Legrand/anchor/schneider or equivalent
Supplying including installation, testing and commissioning of Solar Street light as per following specification and as directed by the Department. 5 W LED SOLAR STREET LIGHT [Confirming RDSO Specification No: RDSO/PE/SPEC/PS/0093-2008(Rev 0)] SYSTEM SPECIFICATION 15 W LED based luminaries/fixture (1500 Lumens –typical). LED Type: White High Powered LED’s 5500-6500 K temperature. Automatic Dusk to Dawn Operate ion. Independent standalone Solar Street Lighting System. Powered by a 12V, 80 Wp Solar PV Module confirming RDSO Part-I Approval & IEC: 61215 Certification. (Model: TBP 1280/ 1280M). (make: TATA BP SOLAR or equivalent) 12V, 75Ah @ C10, Tubular Plate Lead Acid Low Maintenance Battery with PP Container (make: TATA BP SOLAR or equivalent). Battery Box made of M.S fabricated with corrosion resistance paint. 6m height MS Pole with corrosion resistance paint. Manufacturers Criteria: Must have ISO: 9001 & ISO: 14001 Certification. (As per Annexure A: Clause no: b, Page 10) Must have integrated production capacity of Solar PV Cell & Module. (As per Annexure A: Clause no: d, Page: 10) Unit Cost Without Installation & Commissioning)
Installation & Commissioning Charges
Supplying and fixing of Jaquar or equivalent COB Based die cast aluminium housing with toughened glass cover IP65 proctected 70W flood light fittings complete with all accessories including connection cable, as approved by the Deptt.s etc. as required.
Supplying and fixing of Jaquar or equivalent surface mounted 2 x 3W 3000K IP54 up-down lighter with aluminium housing and transparent tempered glass diffuser fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required.
Supplying and fixing of 4W LED Bollard of Jaquar / Philips/ Wipro make outdoor light fittings complete with all accessories including connection cable, as approved by the Deptt.s etc. as required.
MS PA ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .