Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.0 LAccepted-Finance | 1 | Accepted-Finance L1 LOWEST BIDDER | |
| 2 | 2₹1.1 L+₹11,891.80 (11.8%)Rejected-Finance | 2 | Rejected-Finance RATES ARE ON HIGHER SIDE | |
| 3 | 3₹1.2 L+₹16,994.66 (16.8%)Rejected-Finance | 3 | Rejected-Finance RATES ARE ON HIGHER SIDE | |
| 4 | 4₹1.4 L+₹35,933.65 (35.6%)Rejected-Finance | 4 | Rejected-Finance RATES ARE ON HIGHER SIDE | |
| 5 | 5₹2.1 L+₹1.1 L (109.2%)Rejected-Finance | 5 | Rejected-Finance RATES ARE ON HIGHER SIDE |
Tender Value
₹1.4 L
EMD Value
₹1,500
Closing Date
28 Dec 2023, 5:00 pmClosed
SE ETC AZAMGARH
220KV S/S COLONY HAFIZPUR AZAMGARH
SHIFTING OF 132 KV SOLAR BAY AT 132 KV S/S HALDHARPUR UNDER ETD, MAU.
2023_UPTCL_872606_1
84/AETC/2023-24
Open Tender
Electrical Works
Item Wise
15 days
MAU
UTR SLIP OF EMD TENDER FEE PAN CARD GST CERTIFICATE WORK EXPERIENCE etc.
2 documents required · 2 mandatory
₹590
SE ETC UPPCL AZAMGARH
₹1,500
3 Jan 2024
20 Dec 2023
29 Dec 2023
20 Dec 2023
28 Dec 2023
20 Dec 2023
20 Dec 2023 - 28 Dec 2023
Amount
Carriage of structure/materials from Electy. fabrication unit Naini Prayagraj/other Substations To 132 KV S/S Haldharpur. Sorting, counting, stacking mark wise and head loading of structure on truck/tralier (1.039 MT)
Safe carriage of loaded structure from electy. fabrication unit Naini Prayagraj To 132 KV S/S Haldharpur Mau. Distance approx. 250 km (1.039 MT X250 km=259.75 MT-KM)
Unloading of carriage structure from Truck/Trailer its Sorting, Counting and proper Stacking at the S/S premises as per direction of supervisioning engineer (1.039 MT)
Erection of following structure/equipments as per instruction of various equipments manuals and technical specifications including shifting of structures/equipments from store to erection site including all other associated works for completion of erection work satisfactorily:- Auxiliary structures
132 KV SF-6 Circuit Breaker
132 KV C.Ts
132 KV Bus Isolator without earth blades
132 KV C.T Junction box
145 KV Post Insulators
Main & check ABT Meters in ABT meter cubicle.
Jumpering of all equipments of 3 phase 132 KV feeder bay with ACSR Panther conductor between Main bus including all droppers with help of suitable clamps/fittings including hoisting of 70 KN disc insulator on each phase on 132 KV gantry with suspension clamps and required cutting and bending of conductors.(All Clamp/Fitting will be provided by Dept. free of cost)
Cutting, straightening & laying of following MS flat 700 mm below inside ground and above ground of 75mmx10,50 mm x 6 mm size and 25 mm x 6 mm size MS Flats for earthing of main auxiliary structures, equipment and cable trenches including welding with main earthmat and with the object to be earthed excavation of trenches its back filling ,Painting and all other associated work to complete the earthing work satisfactorily as per technical specification. (MS Flat Provided by Contractor) Earthing of structures with 75 mm x 10 mm size MS Flat.
Earthing of structures with 50 mm x 6 mm size MS Flat.
Earthing of auxiliary structures and equipments with 25 mm x 6 mm size MS Flat.
Earthing of cable trenches/Racks with 25 mm x 6 mm size MS Flat.
Prepartion of Interconnection diagram of cable schedule as per drawings to complete job including C.B., C.T., Isolators etc. & submission of same in hard bound sets of 03 copies to the department.
Laying& termination with proper glands and ferruling of following size of control cables in the cable trenches and relay panels in control room to various equipments, junction boxes, etc. in switchyard as per cable schedule its saddling with 25X3mm size including carriage of cable drums from stores to work site and shifting back to store with all other associated works to complete the job satisfactorily as per technical specifications:-(Making Cable Schedule and Termination Schedule is in the scope of Contractor) Laying of 2CX2.5 sqmm size control cable
Laying of 4CX2.5 sqmm size control cable
Laying of 6CX2.5 sqmm size control cable
Shifting of 132 KV Distance Protection Panel from store of substation to the control room/kiosk room and fixing of panels by grouting new bolts etc. with all associated works i.e. earthing of panel alongwith all terminations with proper Glands and Ferruls and neat dressing of cables at control room end at new panels.
Shifting of 132 KV ABT Meter Cubicle from store of substation to the control room/kiosk room and fixing of panels by grouting new bolts etc. with all associated works i.e. earthing of panel alongwith with terminations of cables with proper Glands and Ferruls and neat dressing of cables at control room end at new panels.
Providing & Fixing of Name Plate made of 2mm Thick Alu. sheet with covering of 3M HIP/ Equivalent retro reflective sheet of size 300mmx150mm plate to fixed with the help of Nut & Bolts already installed equipement (C.B.-01No., BSI-01 No., LSI-01No., DPP Panel-01No., Metering Panel-01No., Shutdown Board-01No.) (content to be printed on Name Plate will be provided by department)
Providing & Fixing of Phase Plates made of 2mm Thick Alu. sheet with covering of 3M HIP/ Equivalent retro reflective sheet of size 300mmx150mm plate to fixed with the help of Nut & Bolts already installed equipement (C.T. - 03 Nos., P.T.-03 Nos., L.A.-03 Nos(content to be printed on Phase Plate will be provided by department)
M/s. ADITYA TRADING CO., KM-383, RAIDOPUR OFFICERS COLONY, AZAMGARH, U.P.-276001.
M/s. ABHISHEK CONSTRUCTION, VILL. AND POST- MOHAMMADALLAH, AZAMGARH, U.P.-276001
M/S Shree Constraction
V.P.Associates
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .