Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.0 L+₹3,887 (0.16%)Rejected-Finance 10 2 NARAYAN BAG INDORE M P | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹27.8 L+₹3.8 L (15.9%)Rejected-Finance 22 1755A KANNANKATTU TEMPLE ROAD EDAKOCHI KOCHI 682010 ERNAKULAM KERALA 682010 | ERNAKULAM | KERALA | 682010 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹27.9 L+₹4.0 L (16.6%)Rejected-Finance | L4 | Rejected-Finance Being L4 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
6 Mar 2024, 6:00 pmClosed
GARRISON ENGINEER
Garrison Engineer (Maint) Infantry School , Mhow -453441
REPAIR MAINT OF INTERNAL ELECTRIC WIRING SUB MAIN WIRING CEILING EXHAUST WALL MOUNTING FANS AT ALL AREAS OF INF SCHOOL UNDER GE MIS MHOW
2024_MES_641285_1
8630/GE (MIS)/ Mhow
Open Tender
Civil Works - Others
Item Rate
150 days
GE (MIS) Mhow
All as per Tender document
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (MIS) Mhow
₹64,000
Yes
21 Mar 2024
8 Feb 2024
8 Mar 2024
8 Feb 2024
6 Mar 2024
21 Feb 2024
Amount
REPAIR / MAINT OF INTERNAL ELECTRIFICATION :
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc and removing materials to store for keeping in safe custody or for taking credit ( credit a for above items should be made as per condition seperately ) and making good distrubed surfaces of walls, floors etc. complete all as specified
M & L for Point wiring using approved colour coding as per IS (Red, black and green for single phase circuits) with FRLSH PVC insulated PVC unsheathed electric cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in existing conduit on wall/roof/floor etc making good the disturbed surface of wall including 1.5 sqmm green FRLS PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including galvanised boxes and bakelite sheet for mounting switches, sockets, fan regulators etc for the following.
One light/fan/bell point controlled by one switch
One 5amps socket out let point controlled by one switch on same board with other switches.
One 5amps socket out let point on independent board controlled by one switch.
All as per item No 03 here in before but using FRLS PVC insulated unsheathed 2.5 Sqmm cross sectional area cable for phase /neutral & for earth 2.5 Sq mm green FRLS PVC insulated cable for 15 Amps socket point on independent board controlled by one switch.
M&L for point wiring using approved colour coding as per IS (Red, black and green for single phase circuits) with FRLSH PVC insulated PVC unsheathed electric cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area drawn in and including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good and matching disturbed surface of wall with existing surface of wall (cutting except on ceiling for fan point only, on ceiling instead of PVC conduit surface casing caping will be used) & 1.5 sqmm green FRLSH PVC insulated unsheathed copper conductor as earth wire connected to earth dolly by providing lugs including galvanised boxes and bakelite sheet for mounting switches, sockets, fan regulators etc for the following.
One light point/fan/ Bell point controlled by one switch
One 5amps socket out let point controlled by one switch on same board with other switches.
One 5amps socket out let point on independent board controlled by one switch.
All as per item No 05 here in before but using FRLSH PVC insulated unsheathed 2.5 sqmm cross sectional area cable for phase /neutral & for earth 2.5 Sq mm green FRLSH PVC insulated cable for 15 Amps socket point on independent board controlled by one switch.
M&L for Point wiring using approved colour coding as per IS (Red, black and green for single phase circuits) with FRLSH PVC insulated and unsheathed electric cable 1100 volts grade single core having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area for phase & neutral, drawn in and including non metallic rigid PVC casing caping not less than 25mm base size with all fitting and fixing accessories and with and including 1.5 Sqmm green FRLSH PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor connected to earth dolly by providing suitable lugs including galvanised/wooden boxes of suitable size with white laminated bakelite sheet for mounting switches,sockets etc complete for the following.
One light/ fan/ bell point controlled by one switch
One 5amps socket out let point controlled by one switch on same board with other switches.
One 5amps socket out let point on independent board controlled by one switch.
All as per item No 07 here in before but using FRLSH insulated unsheathed 2.5 sqmm cross sectional area cable for phase /neutral & for earth 2.5 Sq mm green FRLSH PVC insulated cable for 15 Amps socket point on independent board controlled by one switch.
S&F in repairs switch piano flush button single pole one way 6 Amp 240 volts.
S&F in repairs socket outlet flush type 5 pin, 6 Amps, 230 volts
S&F in repairs switch socket combination 2 in 1, 3 pin 16 Amp flush type universal, 240 volts
S&F in repairs switch socket combination 2 in 1, 3 pin 6 Amp flush type universal, 240 volts
S&F in repairs switch piano flush button single pole one way 16 Amp 240 volt.
S&F in repairs socket outlet flush type multipurpose 2 in 1, 3 pin 6 and 16 Amp, 240 volt.
S&F in repairs bell push single pole, 6 Amps, 240 Volts, flush type.
S&F in repairs ceiling rose surface bakelite three terminal
S&F in repairs lamp holder insulated body with back plate for batten fittings.
S&F in repairs Bell, ding dong type, AC 240 Volts,single pole
S&F in repairs electronic fan regulator step type ,AC 240 Volts
S&F in repairs integrated LED tube light fitting 1x18/20 Watt, 6000K complete with all accessories duly connection with three core flexible copper cable and fixed on two nos of PVC square boxes complete all as specified and directed. Make:- Havells Cat No. LHEXBLP7PN1W018 , Bajaj cat Pt No. BCLSB 18WH or equivalent in Wipro
S&F in repairs integrated LED tube light fitting 1x9/10 Watt, 6000K complete with all accessories duly connection with three core flexible copper cable and fixed on two nos of PVC square box complete all as specified and directed .Make:- Havells Cat No. LHEXBLP7IN1W010 Bajaj Cat Pt No. BCLSB 10 WH or equivalent in Wipro
S&F in repairs integrated LED tube light fitting 1x5 Watt, 6500K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos of PVC square box complete all as specified .Make:- Havells Cat No. LHEXBLP7IN1W005, Bajaj Cat Pt No. BCLSB 05NW or equivalent in Crompton /Wipro
S&F in repairs retrofit LED tube light T-8 type, 1x20 Watt, 6500K in Polycarbonate body with extruded Al heat sink for efficient heat dissipation complete all as specified Make:- Havells Cat No.LHLDDCXCML8Q020 , Bajaj Cat Pt No BLRB20CW LED or equivalent in Wipro.
S&F in repairs batten for retrofit type LED tube T-8 Type upto 1x22 Watt, pre-wired for LED tube complete with all accessories duly connection with three core flexible copper cable and fixed on two Nos of PVC square boxes complete all as specified . Make:- Havells Cat No. LHFXCENNTN1W020 / Bajaj Cat No. BLRB20CW LED or equivalent in Wipro. Note for item Nos. 22 to 23:- Makes of these items should be same and compatible with eath other.
S&F in repairs Wall light fittings suitable for LED bulb 9 watt with & including LED bulb of 9 watt, including connection with all necessary fixing accessories complete all as specified Make :- Havells Cat No. LHFOECE1TZ1B014 or equivalent in equivalent in Bajaj, Philips.
S&F in repairs LED Bulk Head luminaire 10W, 6000K pressure die cast housing with IP65 protection complete with electric connection all as specified . Make:- Havells Cat No. HEXAFT10LED857SSYMBOPC, Crompton Cat No. LBH-10-CDL, Bajaj Cat No. BIBWP 10W LED
Supply and fix in repairs LED street light fittings 1x25 /30 Watt, 5700K complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65 protection fixed on and including sufficient length and appropriate size GI bracket with all accessories duly connection with three core flexible copper cable complete all as specified and directed .Make:- Crompton Cat No. LSTO-25-CDL, Bajaj Cat No. ENXTP30LWHSYPCSD and equivalent in Havells cat No. LHEXAYP7PN6K030 .
S&F in repairs LED round light fitting 15W recess mounting type,6000k complete with driver duly connection with copper cable all as specified Make: Havells Cat No. LHEBFCP7IZ1W015 Bajaj Cat Pt No. BGSLO SLEEK 15W WH RD, or equivalent inCrompton, Wipro
S&F in repairs LED round light fitting 18W recess com surface mounting type complete 6000K with driver duly connection with copper cable complete all as specified .Make: Havells Cat No. LHEBADP7IZ1W018 Bajaj Cat Pt No. BGSLO SLEEK 15W WH RD, or equivalent in Crompton, Wipro
S&F in repairs recess mounting type 1'X1' LED Luminaire 18W, 5700K in white finish with opal diffuser with electronic driver duly connection with copper cable complete all as specified. Make: Bajaj Cat Pt No. BZRSQL 18L WH, or equivalent in Crompton , Havells and Wipro.
S&F in repairs LED ceiling light fittings 34/36 watt recess mounting type 2x2 luminaire, 6000k complete with driver duly connection wire all as specified .Make: Jaguar Cat No. LULT02S036XC, Crompton Cat No. LCTLRN-36-FO-CDL, Bajaj Cat Pt No. BZRSQL 36W GZ1 WH or equivalent in Havells Wipro.
S&F in repairs LED ceiling light fittings 34/36 watt surface mounting type 2x2 luminaire, 6000k complete with driver duly connection wire all as specified .Make: Jaguar Cat No. LSVR01S036SC, Crompton Cat No. LCTLRN-36-FO-CDL, Bajaj Cat Pt No. BZRSQL 36W GZ1 WH or equivalent in Havells Wipro.
S&F in repairs LED ceiling light fittings recessed mounting of 06 watt 3000K complete with driver duly connection wire all as specified .Make: Havells Cat No. LHEEAQPBIB1W006 or equivalent in Bajaj Wipro.
M&L for Sub main wiring in repairs with two runs of single core FRLSH PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including surface non metallic rigid PVC conduit not less than 25mm dia and all fittings like bends, tees, saddles etc including one run of FRLSH PVC insulated unsheathed 6.0 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly complete all as specified.
M&L for Sub main wiring in repairs with two runs of single core FRLSH PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including surface non metallic rigid PVC conduit not less than 25mm dia and all fittings like bends, tees, saddles etcincluding one run of FRLSH PVC insulated unsheathed 4 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly complete all as specified.
M&L for Sub main wiring in repair with two runs of single core FRLSH PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia concealed in wall by cutting chases of wall and making good the disturbed surface, including PVC insulated unsheathed FRLSH 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly from main distribution board complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring in repair with two runs of single core FRLSH PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia concealed in wall by cutting chases of wall and making good the disturbed surface, including PVC insulated unsheathed FRLSH 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly from main distribution board complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring in repairs with four runs of single core FRLSH PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia concealed in wall by cutting chases of wall and making good the disturbed surface, including two runs FRLSH PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly from main distribution board complete all as specified and directed by Engineer-in-Charge. Note for Sl item No 34 to 38 : 2/4 runs of 4/6 sqmm single core multistandred copper conductor and one/two run of earth conduit conductor and one length of PVC conduit and its accessories shall be measured as one unit length.
S&F in repairs Modular Switch flush type 6 Amps single pole one way
S&F in repairs Modular Socket outlet, multi purpose, 2/3 Pin combined 6 Amps flush type
S&F in repairs Modular Bell push flush type,6 Amps
S&F in repairs Modular Socket outlet, multi purpose, 2/3 pin combined 16 Amps universal socket
S&F in repairs Modular Switch 16 Amps single pole, one way
S&F in repairs Modular fan regulator step type, 2 module type
S&F in repairs white finished single mounting modular plates suitable for modular accessories of following sizes Make: Legrand Mylinc Series, Anchor Roma Plus, Crabtree Athena Series
suitable for 1/2 modules
suitable for 3 modules
suitable for 4 modules
suitable for 6 modules
suitable for 8 modules
S&F in repairs sheet metal boxes concealed in wall suitable for modular accessories of following sizes Make: Legrand Mylinc Series, Anchor Roma Plus, Crabtree Athena Series
suitable for 1 or 2 modules 50mm.
suitable for 3 modules 50mm.
suitable for 4 modules 50mm.
suitable for 6 or 8 modules 50mm.
S&F in repair flush mounting factory made Vertical TPN DB, IP-43 Protection -IK 08 with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of space for 100-125 Amps MCCB as incomer and SP/TP MCBs as out going 4 way complete all as specified Make:- HPL/L&T/HPL/Havells
S&F in repair flush mounting factory made Vertical TPN DB, IP-43 Protection -IK 08 with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of space for 100-125 Amps MCCB as incomer and SP/TP MCBs as out going 8 way complete all as specified Make:- HPL/L&T/HPL/Havells
S&F in repairs double door TPN DBs four way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified Make: HPL/L&T/HPL/Havells
S&F in repairs double door SPN DBs eight way, powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified. Make : HPL/L&T/HPL/Havells
S&F in repairs double door SPN DBs four way, powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified and directed by Engineer-in-Charge. Make : HPL/L&T/HPL/Havells
S&F in repairs MCCB FP 125 Amps 27 KA including connection with suitable size aluminium / copper lugs complete all as specified. Make - HPL/L&T/HPL/Havells
S&F in repairs MCB TPN 50 to 63 amps 10 KA, c-series including connection with suitable size aluminium/copper lugs complete all as specified Make : HPL/L&T/HPL/Havells
S&F in repairs MCB SPN 6 to 32 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified . Make : HPL/L&T/HPL/Havells
S&F in repairs MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'B' series including connection with suitable size aluminium / copper lugs complete all as specified . Make : HPL/L&T/HPL/Havells
S&F in repairs Single pole and neutral Sheet Metal enclosure with a two pin and earth plug and socket including one single pole MCB,20 Amps and cutting of wall and fixing of AC box in concealed system and making good of disturbed surfaces complete all specified and as directed.
M & L for Earthing in repairs complete with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.5 of MES SSR part-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type C1 with 40 mm thick RCC 1:2:4 type B1 cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed.
S&F in repairs Hylem bakelite sheet ISI marked and providing suitable hole on hylem sheet for fixing of swiches ,sockets and modular plates as per site requirement and suitable for housing modular accessories of following sizes
Hylem bakelite sheet of size ( 5 inch x 5 inch) suitable for 1 or 2 modules 50mm
Hylem bakelite sheet of size ( 8 inch x 5 inch) suitable for 3 modules 50mm.
Hylem bakelite sheet of size ( 6 inch x 9 inch) suitable for 4 modules 50mm.
Hylem bakelite sheet of size ( 9 inch x 11 inch) suitable for 8 modules 50mm.
S&F PVC rectangular block for mounting switches,sockets,fan regulators etc. With 3 mm thick plastic laminated sheet cover of following sizes as below.
100mmx100mmx50mm
175mmx100mmx50mm
200mmx150mmx50mm
250mmx200mmx50mm
Note for Sl items No 1 to 59: (a) The contractor should deploy a minimum two electricians and two helpers to attend the above day-to-day complaints. The contractor's electrician and helper should be available at AGE E/M Complaint Cell on each day at 09.00 AM and rectify the complaints on the same day and the report should be submitted at 05.00 PM to the concerned JE E/M. (b) Contractor shall provide all necessary T&P, ladder, etc as required for repair/replacement of Lights and point wiring at the Wall and ceiling at any Height. Quoted rates shall be inclusive of the above provision and nothing extra shall be allowed and paid to the contractor.
REPAIRS / MAINT CEILING / EXHAUST /WALL FAN:
M&L for attending and rectifying day to day complaints of fans by taking down carefully existing ceiling fans /exhaust fan / wall mounted fan of any type/size/make from its position at various location such as OTM, Md accommodation and offices under GE(MIS) area,by removing the blades from fan, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bushes , burnt winding, shaft, split pin, condenser etc reassembling after winding and replacing defective parts with new parts including provision of 3 core 1.50 Sqmm) flexible copper cable from ceiling rose to connector , refixing of removed blades and hanging /fixing in its original position properly including necessary testing after hanging fixing complete all as specified and directed.
Note for Ser item No 62 :- (a) Quoted rate shall be inclusive for grease,bushes,shaft,split pin etc (b)Winding of ceiling fan and spare parts such as ball bearing,capacitor etc required to making the ceiling fan serviceable shall be measured and paid separately under relevant items here in after. (c ) Contractor quoted rate shall be inclusive for to collect and transport new/old /serviced/winded ceiling/exhaust/wall fan of any size and any make from AGE E/M store yard and fix at required location as directed by Engineer-in-Charge. (d) Quoted rate shall be inclusive for assembling and fixing at site as directed including servicing, if required (e) Representative of the contractor shall be present at complaint cell and collect the complaints at 9.00 Am every day and attending and resolve the complaints immediately and repot the status of complaint to Engineer-in-Charge at 05:00 pm on the same day.Necessary record shall be maintained by Contractor.
M&L for rewinding of following fan motor with super enamelled copper winding wire of same gauge and as per existing and weight including cleaning of rotor, stator , varnishing, heating and provision of fresh insulating materials for the following size of ceiling / exhaust /pedestal /wall mounted fan all as specified and directed.
For ceiling fan of 1400 mm sweep
For ceiling fan of 1200 mm sweep
For Exhaust fan 400mm to 450mm sweep
For Exhaust/wall mounted fan 230mm to 380mm sweep
Note For item No 63 : (a)Quoted rate shall be inclusive for collection of ceiling/exhaust/wall mounted fan from the existing site and AGE E/M No.1 store yard by contractor's own arrangement, removing defective parts, burnt winding carefully, cleaning & re-assembling the fan after winding (ie) oiling, greasing, washer, lock bolts, connector, cross pin etc, return back to AGE E/M No.1 store yard and testing at yard for proper working to the satisfaction of Engineer-in-charge .(b) Spare parts shall be measured and paid seperately under relevant items supply only
Supply only in replacement of following parts of fan all as specified and directed by Engineer- in-Charge.
Ball bearing of size 6201, 6202, 6203 (Make: NBC /SKF)
Gun metal bush self lubricated of suitable size for ceiling and wall mounting fan
Clamp for hanging ceiling fan made out of MS heavy duty flat iron of size 40x 6 mm as per sample including nuts, bolts, washers, etc suitable for 40/50 mm dia GI pipe/angle iron complete all as specified and directed by Engineer-in-Charge.
Canopy (Set of two) suitable for exisiting Ceiling fan of any size
Fan connector suitable for fixing of capacitor for ceiling fan of any size
Fan plate suitable for exisiting Ceiling fan of any size
Holding clamps for ceiling fan with rubber reel, nuts, bolts, washers, split pins complete all as specified
Supply and fix in repairs PVC insulated and FRLSH flexible cable three core Copper conductor of size 23/0.0076 (3 Core x 0.50 Sqmm), ISI marked, complete all as specified and directed by Engr-in-Charge (other than for fans covered in item Sl. No. 01 above in which the rates are deemed to be inclusive.)
Supply only blade set (03 Nos) suitable for Ceiling fan 1200mm/1400mm sweep matching with existing blades complete all as specified and directed
Supply only exhaust fan blade of existing pattern for 230mm sweep (as per sample ) complete all as specified and directed
Supply only exhaust fan blade of existing pattern for 300mm sweep (as per sample ) complete all as specified and directed
Supply only exhaust fan blade of existing pattern for 450mm sweep (as per sample ) complete all as specified and directed
S&F in repairs exhaust fan louver of existing pattern (as per sample ) for 230mm sweep exhuast fan including providing necessary items as required for fixing of louvers complete complete all as specified and directed
S&F in repairs exhaust fan louver of existing pattern (as per sample ) for 300mm sweep exhuast fan including providing necessary items as required for fixing of louvers complete complete all as specified and directed
S&F in repairs exhaust fan louver of existing pattern (as per sample ) for 450mm sweep exhuast fan including providing necessary items as required for fixing of louvers complete complete all as specified and directed
S&F in repairs exhaust fan metal frame of existing pattern (as per sample) suitable for 230mm sweep including providing suitable holes, nuts,bolts , washers etc. for fixing of exhaust fan complete all as specified and directed .
S&F in repairs exhaust fan metal frame of existing pattern (as per sample) suitable for 300mm sweep including providing suitable holes, nuts,bolts , washers etc. for fixing of exhaust fan complete all as specified and directed .
S&F in repairs exhaust fan metal frame of existing pattern (as per sample) suitable for 450mm sweep including providing suitable holes, nuts,bolts , washers etc. for fixing of exhaust fan complete all as specified and directed .
S&F in repairs table fan/wall fan blades as per existing pattern size 400 mm sweep complete as per sample complete all as specified and directed
S&F in repair condenser 0.80 MFD, 240 Volts, AC 50 Hz confirming to IS 1709 .Make:- Epcos or other equivalent as approved by GE.
S&F in repair condenser 2.5 MFD, 240 Volts, AC 50 Hz confirming to IS 1709 .Make:- Epcos or other equivalent as approved by GE.
S&F in repair condenser 4.0 MFD, 240 Volts, AC 50 Hz confirming to IS 1709 .Make:- Epcos or other equivalent as approved by GE.
S&F in repairs of MS down rod 'medium grade' 15mm dia of length 0.75 m complete with making split holes, cut or threads at both end of pipe as required for hanging of ceiling fan including painting of rod with two coats of synthetic enamel white paint over one coat of primer complete all as specified and directed
All as per item no 81 above but for length 1.50 m
All as per item no 81 above but for length 3.0 m
M&L for making hole of appropriate size by cutting in the existing wall to fix exhuast fan of size 300/450 mm sweep including making good the disturbed surfaces to match with existing surface of wall including fixing exhaust fan with necessary suitable size nuts, bolts, washers as required at site and connecting with and including suitable size and length of PVC insulated three core flexible three core copper conductor from ceiling rose complete all as specified and directed Note:- Exhaust fan shll be collected from AGE E/M-01 store yard and quoted rate shall be inclusive of above provision .
M&L for cleaning and preparing the surfaces of ceiling/exhaust fan of any sweep and type , removing the grease, carbon dust over the fans ,filling cavities with filler and applying one coat of synthetic enamel paint of approved colour by sprying including writing MES number on the fan complete as in situ all as specified and directed
Note for Ser items No 61 to 85: (a) Contractor should deploy a minimum of 03 Nos of Electrician and 03 nos of helpers for attending above day-to-day complaints. The contractor's electrician and helper should be available at the AGE E/M complaint cell each day at 09:00 AM and rectify the complaints on the same day and the report should be submitted at 05:00 PM to the respective JE E/M . The contractor's rep shall be responsible for maintaining the complaint register book properly (b) Contractor shall provide all necessary T&P, ladder, etc as required for repair/replacement of ceiling/exahust/wall mounted fans etc at the Wall and ceiling at any Height. Quoted rates shall be inclusive of the above provision and nothing extra shall be allowed and paid to the contractor.
S.S. Engineers
sanjay traders
Mighty Steel Sales Crop
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .