Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹24.2 L+₹11,034 (0.46%)Rejected-Finance | L2 | Rejected-Finance Rates are high | |
| 3 | L3₹25.1 L+₹1.0 L (4.31%)Rejected-Finance | L3 | Rejected-Finance Rates are high | |
| 4 | L4₹25.4 L+₹1.3 L (5.43%)Rejected-Finance | L4 | Rejected-Finance Rates are high | |
| 5 | L5₹25.4 L+₹1.3 L (5.54%)Rejected-Finance | L5 | Rejected-Finance Rates are high |
Tender Value
Refer Docs
EMD Value
₹51,000
Closing Date
1 Mar 2021, 6:00 pmClosed
GE (MIS) MHOW
GE (MAINT) INF SCHOOL 75 MALL ROAD MHOW
MANNING AND OPERATION OF MAIN PUMP HOUSE FILTRATION PLANT AND BEIRCHHA PUMP HOUSE UNDER GE MAINT INF SCHOOL MHOW
2021_MES_417508_1
GE MIS MHOW/71 OF 2020-21
Open Tender
Miscellaneous Works
Item Rate
334 days
GE (MIS) MHOW
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (MIS) MHOW
₹51,000
Yes
22 Mar 2021
1 Feb 2021
3 Mar 2021
8 Feb 2021
1 Mar 2021
15 Feb 2021
Amount
Manning and operation of Bercha lake and Pump House at Bercha including installation/ equipments detailed below by employing one FGM, in three shifts of Eight hours duration each shift (from 0600 hrs to 1400 hrs, 1400 hrs to 2200 hrs and 2200 hrs to 0600 hrs) including maintaining of log sheets complete all as specified and directed by Engineer-in-Charge . NOTES:- I. Machinery/Equipment to be manned and operated:-
Machinery/Equipment to be manned and operated:- 1. Bercha lake, juna pani nala and bandh etc. 2. Syphon Assys 80 mm each including valves-04 3. Syphon Assys 100 mm each including valves-02 sets 4. Valves house-02 Nos 5. Pump house-02 Nos 6. Stere Room-01 Nos 7. RCC sump Capacity 150000 Gallon-01 No 8. Centrifugal pumping sets 30 HP with all accessories-02 Nos 9. Centrifugal pumping sets 40 HP with all accessories-02 Nos 10. Centrifugal pumping sets 50 HP with all accessories02 Nos 11. DG set Cap 125 KVA 01 Nos 12. Electric panel of pump set including area lighning.
Manning and operation of filtration plant and MES pump house and installed machinery including the chorination of raw water as detailed below by employing one (FGM) as per E-in-C's standing orders in three shift of 0800 hrs each (from 0600 hrs hrs to 1400 hrs, 1400 hrs to 2200 hrs to 0600 hrs) including maintaining of log sheets complete all as specified and directed by Engineer-in Charge.
Manning and operation of filtration plant and MES pump house and installed machinery including the chorination of raw water as detailed below by employing one (helper) as per E-in-C's standing orders in three shift of 0800 hrs each (from 0600 hrs hrs to 1400 hrs, 1400 hrs to 2200 hrs to 0600 hrs) each shift means complete continues 08 hrs duration) complete all as specified and directed by Engineer-in Charge.
Machinery/Equipment to be manned and operated:- 1. Flocculator, Filter Beds, Chlorination sump, Alum dosing system etc. 2. Air blower 20 HP capacity -02 Nos 3. All controling Valves (Sluice/Butterfly valves) at Filtration plant and pump house Area. 4. Valve house 02 Nos 5. Pump house -03 Nos 6. DG Room 01 Nos 7. RCC Sump capacity 15 lakh Gallon -03 Nos 8. Centrifugal pumping sets 100 HP with all accessories, starter etc. including panel 01 Nos 9. Centrifugal pumpng sets 75 HP with all accessories, starter etc. including panel 08 Nos 10. DG set capacity 250 KVA with all accessories including panel 01 Nos 11. DG set capacity 200 KVA with all accessories including panel 01 Nos 12. DG set capacity 160 KVA with all accessories including panel 01 Nos 13. All electric panel and area lightning.
Supply & Fix in repairs of sluice valves cast iron body, double flanged, ISI marked (IS-14846), heavy duty, class PN -1.6 gun metal, with rising spindle of solid forged bronze and poerating handle, including rubber gaskets, nuts, bolts, washers etccomplete of the following sizes:-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
Taking out sluice valves refaving, regrinding and refixing of following sizes:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Supply and fix in repairs of water pressure gauge, anologue type of range up to 0-150 PSI complete all as specified as directed:-
Supply and fix in repairs of Brass spindle externally threadedand in repairs in sluice valves of follwing sizes:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Supply and fix in repairs of Brass wedges nut with internal threaded in sluice valves of following sizes:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Notes :- For all Items of BOQ ; If the quoted amount is less than the estimated cost of the work i.e. 25.50 Lakhs, then the lowest bidder will have to deposit FDR/BGB in favour of Accepting Officer within 07 days of opening of finacial bid for the difference in estimated cost i.e. 25.50 Lakhs & quoted amount. In case the said FDR/BGB is not submitted within stipulated period mentioned above, the contractor shall be banned for 06 months & his bid will be rejected. The said Amt deposited by the lowest bidder will be released after two months of certified completion of work.
LAKSHMI DEVELOPERS
ENVIRO TECH SERVICES
MODI CORPORATION
Vinayak Trading House
SUNIL ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .