| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC 262 1 NEAR MANAV CHOWK NEW GRAIN MARKET AMBALA CITY HARYANA HARYANA 134003 | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹8.3 L+₹27,012 (3.37%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹8.4 L+₹34,631 (4.31%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹9.7 L+₹1.7 L (21.1%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 5 | L5₹9.9 L+₹1.8 L (22.8%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
10 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
S F AUGUSTINE IDSE EE
MES OFFICE GE KASAULI DISTT SOLAN HP
REPAIR MAINT OF INTERNAL ELECTIFCATION IN OTM AND MD ACCN AT MIL STN KASAULI UNDER GE KASAULI
2021_MES_460072_1
GEK-38/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KASAULI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KASAULI
₹30,000
Yes
26 Aug 2021
15 Jul 2021
13 Aug 2021
15 Jul 2021
10 Aug 2021
29 Jul 2021
60 days
Amount
Schedule 'A' Section - I
Taking down carefully aluminium/ copper conductor point wiring (light, fan, light socket, power socket) complete fitting such as switches, sockets, lamp holder, utility light fitting, fan regulator, ceiling rose etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed.
M & L for point wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing sunken boxes for mounting of switch, socket etc incl taking down unsv if reqd complete all as specified and directed for the following :-
One Light/Fan/Bell point controlled by one, one way switch 6 Amp complete
One switch socket outlet 3 pin, 5 Amp on the independed board
One switch socket outlet 3 pin, 5 Amp on same board
All as per item No 2 but point wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 Sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly for one 16 Amps socket (Power) point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket etc incl taking down unsv if reqd complete all as specified and directed.
M & L in replacement sub main wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces etc after incl down unsv if reqd all as specified and directed.
S & F in replacement switch piano flush button single pole one way, 6 Amps, 240 Volt incl taking down unsv complete all as per specified and directed
S & F in replacement bell push piano flush type 6 amps , 240V incl taking down unsv complete all as per specified and directed
S & F in replacement buzzer ding dong, AC 230 volts Single Phase incl taking down unsv complete all as per specified and directed
S & F in replacement socket outlet 2-in-1 5 pin, 6 Amps flush type complete all as specified and as directed.
S&F in replacement switch piano flush button single pole one way, 16 Amps, 230/240 V incl taking down unsv complete all as specifed and directed
S&F in replacement socket outlet 2-in-1 5 pin, 6 & 16 Amps flush type incl taking down unsv complete all as specified and as directed.
S&F in replacement PVC Plug Top 5 pin, 6 & 16 Amps flush type incl taking down unsv complete all as specified and as directed.
S & F in replacemnt ceiling rose surface, backelite, three terminal, 240 volts incl taking down unsv complete all as specified and directed.
S & F in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings incl taking down unsv complete all as specified and as directed.
S&F Wall mounted LED batten box type pre coated CRCA body suitable for retrofit LED tube rod 18 Watt including LED self ballasted LED retrofit tube lamp 18 Watt with thermoplastic body min 1800 system lumens and builtin surge protection of 2.5 KV fixed in repair incl taking down unsv complete all as specified and directed.
S&F LED self ballasted LED retrofit tube lamp 18 Watt with thermoplastic body min 1800 system lumens and builtin surge protection of 2.5 KV incl taking down unsv complete all as specified and directed.
S&F Wall mounted mirror light LED fitting self ballasted LED batten extruded thermoplastic body with PC diffuser in unique square shaped 10 watt 2 Feet long CCT 6500K fixed in repair incl dismantling taking down unsv fitting any type complete all as specified and directed.
S&F Surface mounted LED bulk head 10 watt luminaire with ABS body & polycarbonate diffuser IP 65 including connecting to ceiling rose with 0.5 sqmm two core copper flexible conductor cable fixed in repair incl lamp incl taking down unsv complete all as per specified and directed.
S&F self ballasted LED Retrofit Bulb 5 Star Bulbs 9 Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL/LED Bulb complete all as specified and as directed.
S&F self ballasted LED Retrofit Bulb 5 Star Bulbs 12 Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL/LED Bulb complete all as specified and as directed.
S&F self ballasted LED Retrofit Bulb 3Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, E-14 cap, (Thread type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL/LED Bulb complete all as specified and as directed.
S&F self ballasted LED Retrofit Bulb 3Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, E-27 cap, (Thread type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL/LED Bulb complete all as specified and as directed.
S&F LED Slim panel size 2'x 2' ,40 Watt recess/ surface mounting edge lit LED slim panel having white powder coated extruded aluminium body with high quality LGP and PMMA diffuser , separate HPF driver suitable for Armstrong and grid ceiling separate accessories for recess /surface mounting PCGLP 2X 2, CCT 4000K fixed in repair incl dismantling taking out unsv one of any make/ size complete all as specified and as directed.
S&F Recess mounting ceiling fitting 1'X4' LED 36 Watt light Edgelit slim panel having white powder coated extruded aluminium body with high quality LPG and PMMA diffuser. Separate HPF driver. Suitable for Armstrong and Grid ceiling, PF min 0.95 complete incl dismantling taking out unsv one of any make/ size complete all as specified and as directed (As per existing Sample).
S&F Recess mounting ceiling fitting 1'X1' LED 18 Watt light Edgelit slim panel having white powder coated extruded aluminium body with high quality LPG and PMMA diffuser. Separate HPF driver. Suitable for Armstrong and Grid ceiling, PF min 0.95 complete incl dismantling taking out unsv one of any make/ size complete all as specified and as directed (As per existing sample).
Supply and fixing building security LED light 25 Watt energy saving LED ASTRA NEO street light made up of pressure dia cast housing with toughened glass and high power LEDs with option of secondary optic with IP66 protection, efficacy : 110LM/W one GI medium grade 25mm dia bracket of total lenghth 50 cm incl 2 Nos MS Clamp and fastners after dismantling taking down unsv one all as specified and directed.
S&F MCB DB TPN 4 way double door, IP 43, CRCA sheet powder coated vertical type factory made suitable for incorporating MCB as out going and MCCB as incoming including connecting incoming and outgoing cables & blaking plate as required incl taking down existing unsv DB of any size and making good distrubed surface to match with existing complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble).
S&F MCB DB SPN 4 way double door, IP 43, CRCA sheet powder coated, factory made suitable for incorporating MCB as out going connecting incoming and outgoing cables & blaking plate as required including taking out existing unserviceable DB of any size and making good disturbed surface to match with existing incl taking down unsv complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble).
S&F MCB DB SPN 8 way double door, IP 43, CRCA sheet powder coated factory made suitable for incorporating MCB as out going connecting incoming and outgoing cables & blaking plate as required incl taking out existing unsv DB of any size and making good disturbed surface to match with existing incl taking down unsv complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble).
S&F MCB TPN 63 Amps, 10 KA 415 Volt, 50 Hz, IS/IEC 60898-1, 'C' curve including taking down unserviceable complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble).
S&F MCB SPN 32 Amp to 40 Amp, 10 KA, 240 volts, IS/IEC 60898-1, 'C' curve including taking down unserviceable complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble).
S&F MCB SP 6 Amp to 32 Amp 10 KA, 240 volts, IS/IEC 60898-1, 'C' curve including taking down unserviceable complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble)
S&F Single pole and neutral enclosure with a two pin and earth plug and socket board with IS 13032, IS 8623 complete with one single pole 20 amp MCB complete incl dismantiling taking out unsv complete all as specifed and directed.
S&F Heating Element ISI Marked round/ tringular base, push type or thread type including rubber washer for 1.5/2.0 KW suitable for geysers 25 Ltrs to 50 Ltrs capacity (as per existing sample) including taking down unserviceable complete all as specified and as directed.
S&F thermostat ISI Marked suitable for geysers 25 Ltrs to 50 Ltrs capacity (as per existing sample) including taking down unserviceable complete all as specified and as directed.
S&F Cromium plated connections 45 Cm long for Hot/Cold water of 15mm size with cromium nuts and washsers fixed as in repairs complete all as specified.
S & F in replacement of PVC gang box suitable for 6 Amp Socket and 6 Amp switch complete all as per specifiec and directed
S & F in replacement of PVC gang box suitable for 16 Amp Socket and 16 Amp switch complete all as per specifiec and directed
Supply only electric insulation tape heavy duty complete all as per specifed and directed
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium, conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 Sq. mm x 2 Core nominal cross section in service connections complete all as per specifed and directed.
Dismantling and taking out the unsv/burnt copper wire of the motor from the exhaust fan and rewinding the motor of the exhaust fan of any make of size 250mm/300mm/450mm sweep with super enamelled copper wire of same size guage and weight as per existing including necessary insulating material to gain desire RPM as per manufacture design and varnishing the winding with two coats of synthetic varnish including heat treatment oiling greasing complete and reassembling of all parts with testing on completion complete all as specified and directed
S&F in repair Exhaust Fan 250mm Sweep plastic body, 1400 RPM with air delivery 1050 CMH including and taking down unserviceable and depositing to E/M Store complete all as specified and directed.
S&F in repair Exhaust Fan 300mm Sweep metal body (Heavy Duty), 1400 RPM with air delivery 1050 CMH including and taking down unserviceable and depositing to E/M Store complete all as specified and directed.
S&F 40 Watt post top fitting powder coated aluminum die cast and spun aluminium with decorative clear diffuser suitable for landscape lighting in 5700K CCT and IP 65 protection fixed in repair including and taking down unserviceable complete all as specified and directed.
S&F LED Bollard light suitable for garden/lawn 10 Watt 230 volts 50 Hz including necessary earth work and excavation and PCC foundation fixed in repair including and taking down unserviceable complete all as specified and directed.
Amount of credit of Rs. 37361.00 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
R. P. Suppliers and Construction Co.
Rajesh Agencies
Vasudeva Trading Co.
Vishal Builder
Pankaj Traders
bharat refrigeration and electric co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .