| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | ₹1.4 Cr Quoted ₹1.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.5 Cr+₹8.5 L (5.82%)Rejected-Finance 5 KEDAR APARTMENTS 484 60 PARVATI MITRAMANDAL COLONY PARATI PUNE 411 009 | PUNE | PUNE | MAHARASHTRA | 411009 | ₹1.5 Cr+₹8.5 L (5.82%) | L2 | Rejected-Finance REJECTED NOT BEING L1 |
| 3 | L3₹1.6 Cr+₹11.3 L (7.77%)Rejected-Finance 0 NERTHUA RAEBARELI UTTAR PRADESH 229103 | RAE BARELI | UTTAR PRADESH | 229103 | ₹1.6 Cr+₹11.3 L (7.77%) | L3 | Rejected-Finance REJECTED NOT BEING L1 |
| 4 | L4₹1.6 Cr+₹12.6 L (8.69%)Rejected-Finance | ₹1.6 Cr+₹12.6 L (8.69%) | L4 | Rejected-Finance REJECTED NOT BEING L1 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
15 Jun 2023, 6:00 pmClosed
COL VIKAS KESARWANI
CWE (AF) LOHEGAON, PUNE - 411032
ADDITION, ALTERATION TO SMC UNDER GE (AF) LOHEGAON AT AIRFORCE STATION PUNE
2023_MES_595197_1
81877/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) LOHEGAON
As per NIT
6 documents required · 6 mandatory
₹1,000
Yes
GE (AF) LOHEGAON
₹2.2 L
Yes
21 Jul 2023
13 May 2023
22 Jun 2023
13 May 2023
15 Jun 2023
3 Jun 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid in any type of motar complete all as specified and directed.
M & L cement concrete type B0 1:2:4 (12.5 mm graded agg) 25mm thick as in sub floors complete all as specified and directed.
M&L for Vitrified Ceramic tiles 10 mm thick light shade (square/rectangular) polished, area of each tiles exc .18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including Screed Bed 15 mm thick in Cement Mortar (1:6) complete all as specified and as directed.
Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 15 mm thick screed bed in CM (1: 6) complete all specified and directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm in floors {Superior/Premium quality}, set and jointed in neat cement slurry and pointed in colour cement to match the shade of tile over and including 15 mm thick screed bed in CM (1: 6) complete all specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incluidng rubbing and polishing complete including screed bed 15mm thick in cement motar 1:6 complete all as specified and directed.
M & L for Mirror polishing on marble/granite/kota stone/stone work where ever required to give high gloss finish complete all as specified and directed.
M&L Glazed Ceramic Coloured Tiles, 350X250X7mm/450X350X7mm thick in size, set on Vertical Surfaces such as Skirting, Dado, etc,over and including 10mm thick rendering in cement mortar 1:3 Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed.
M&L Glazed Ceramic Coloured Tiles, 300x200x7mm thick in size, set on Vertical Surfaces such as Skirting, Dado, etc,over and including 10mm thick rendering in cement mortar 1:3 Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed.
M &L Machine cut cudappah stone slab 20-25mm thick over 10mm thick plaster of cement 1:3 in wall and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. (For rack purpose)
M&L granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in CM (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and directed.
M & L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and no pigment complete all as specified and directed.
M & L for (50mm thick ) sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for 100 mm thick cement concrete Type B-2, 1:2:4 (using 20mm graded stone aggregate), as in floors, etc, and finished the cement concrete surfaces even and smooth with out using extra cement, complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type D-2 (using 40mm graded stone aggregate as in sub base of floor and path, plinth protection etc.complete all as specified and directed.
M&L Forming Contraction (Dummy) joints 75 mm deep x 10mm wide for plinth protection & similar work, filled with sealing compound Grade 'A' in plinth protection complete all as specified and directed.
M & L for acid washing of existing floors/wall surfaces of (Ceramic tiles/Vetrified tiles ) Bathroom/Laboratory/Office/Dispencery/Reception etc all as specified and directed.
Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-charge
M&L for Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) 600 x 600 mm fixed to aluminium grid frame all as specified and directed by Engr-in-charge
M&L Anodised aluminium snap grid size 605 x 605 mm frame work for false ceiling and hangers 6mm dia G. I (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed.
S & F Solid PVC wall lining consistng of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawings complete all specified and directed.
S &F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all specified and directed.
M & L for taking down existing roof treatment of any description in suspended slabs in roofs, chajjas, etc,including cement mortar, complete all as specified and directed.
M&L for 10 mm thick rendering on fair faces of brick works / Concrete surfaces finished even and smooth without using extra cement in cement mortar 1: 4 complete all as specified and as directed
M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforment with polyster non woven fabric (wt reinforcement not less than 150 gms/sqm) laid on bituminous primed surfaced application including preperation and applaying two coats of Heat resisting Aluminium paint over APP Membrane complete all as apecified and directed.
Supply liquid water proofing compound
M&L PCC 1:2:4, 25 mm thick type B0 using 12.5mm graded stone aggregate as in padding of roof surfaces finished even and fair with out using extra cement complete all as directed by Engr-in-charge.
Demolition of cement concrete (un-reinforced) in ground floors and paving's not exc 15 cm thickness (below or above ground level) all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm all as specified and directed.
Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings complete all specified and directed.
S&F pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling of structural steel work complete all as specified and directed.
S & F Rolled Mild Steel roof trusses(framed),trussed ,purlins ,rails and fastenings etc.,confirming to Fe 410 - S including distance pieces, cleats, etc., complete all as specified and directed.
S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
M&L for 100 mm thick cement concrete Type D-2, 1:4:8 (using 20mm graded stone aggregate), as in floors, etc, and finished the cement concrete surfaces even and smooth with out using extra cement, complete all as specified and as directed.
S &F 150mm dia thickness of sheet 1mm mild steel sheet eaves gutters galvanised class 3 half round with rounded edges complete all specified and directed.
S &F 150mm dia, 1mm thickness of sheet of Angles (internal or external ) or nozzle pieces (out lets) complete all specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm in repairs complete all specified and directed.
M & L for foot operated taps in sink including Taps, operating system, pipes Exposed Foot Operated Auto Closing Valve for Pressmatic Basin Taps Only with Plug (Table Mounted Model) with Two 900 & 1200mm Long raided Hoses with 15mm Nuts etc all as specified and directed.
M &L for 18mm thick plywood BWR grade type BB fixed with screws to timber frame work all as specified and directed.
Ditto all as per Ser Item No 42.00 as above but 12mm thick complete all specified and directed.
Ditto all as per Ser Item No 42.00 as above but 6mm thick complete all specified and directed.
M&L for 0.90mm thick decorative laminate type – I of surface finish (colour & pattern as approved) fixed with approved adhesive as per manufacturer’s instruction finished to approved size for working table all as directed by Engineer-in-Charge.
M&L for 2nd class H.W. plain cover fillets square, rectangular or triangular in section bull nosed, splayed chamfered or rounded on one edge or face in 2nd class H.W. sectional area n. exc. 6 Sqcm all as specified and directed.
M&L for 2nd class H.W. plain cover fillets square, rectangular or triangular in section bull nosed, splayed chamfered or rounded on one edge or face in 2nd class H.W. sectional area exc. 6 Sqcm and not. exc 13 Sq cm all as specified and directed..
S&F brass hinges 75mm size extruded with stainless steel pin type D-11 all as specified and directed.
S&F Lock cupboard grade I, size 50mm brass 75mm size 4 level complete all specified and directed.
S&F brass handles extruded fabricated type 100mm size complete all specified and directed.
S &F 50mm dia polished hard wood knobs fixed with screws complete all specified and directed.
S &F 100mm size of hasp and staple safety type brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all specified and directed.
Taking down chowkat with shutter without taking out shutter from the frame exc 1.5 and n.exc 4 Sqm each complete all specified and directed.
Taking down chowkat with shutter without taking out shutter from the frame n.exc 1.5 Sqm complete all specified and directed.
Taking down shutters of any description n exc 1 sqm each complete all specified and directed.
Taking down Shutters of description exc 1sq.m and n exc 2 sq. m each complete all as specified and as directed.
Taking down Shutters of description exc 2sq.m each complete all as specified and as directed.
Supply and fix for factory made solid Panel PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded Prelaminated PVC sheet on the front face and 2mm prelaminated colour PVC sheet on back face, fixed in frame at site as per specification and drawing including fittings complete all as specified and as directed.
Supply and fix for solid PVC door frame of size 50mm x 47mm, made out of 5 mm thick plain colour PVC sheet, reinforced with mild steel square tube complete all as specified and as directed.
S&F aluminium powder coated three track sliding window with two shutters of 5mm thick tinted glass of modigaurd and one shutter of stainless steel wire mesh including good quality of bearing handle, locks, PVC rubber lining including frame work etc complete all as specified. :- Three track bottom – 20957, Three track top/vertical – 20958, Handle – 20606,Interlocking – 20605, Top and bottom – 20604.
M&L for aluminium powder coated louvered ventilator with provision of exhaust fan using aluminium section including glass and stainless steel wire mesh including frame work etc complete all as specified and directed by Engineer-in-Charge.
S&F Powder Coated Anodised aluminium Sliding Door, window and ventilator shutters, without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, roller and mortise lock etc. complete all as specified and directed by Engr-in-Charge.
M&L sheet glass 4.8mm thick ordinary quality and glazing with aluminium beeds in square exc 0.50 sqm in each pane complete all as specified and as directed
S &F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed.
S & F Steel windows or ventilators, fixed type, with glazing bars all as specified and directed.
S&F in repairs 18/19 Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed screws to timber work all as specified and directed.
S &F 12mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape drilling holes rquired, handles all as specified and directed.
S & F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufactureres all as specified and directed.
S &F 5mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sqm in each pane all as specified and directed.
S & F double action floor spring Hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed in repairs.
S & F 100 mm size butt hinges, medium weight, cold rolled brass complete all as specified and as directed.
S&F 150 mm long brass, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150 mm size Brass handles, Extruded aluminium alloy handles, abricated type, anodised complete all as specified and as directed.
S&F 250 mm long Brass sliding door bolt, plate type, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed.
S&F second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
S&F 30 mm thick second class hardwood glazed and skeleton shutters divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers and prepared to receive glass, gauze, etc., edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, gauze, etc.complete all as specified and as directed.
S&F 30 mm thick second class hardwood glazed and skeleton shutters divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers and prepared to receive glass, gauze, etc., edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, gauze, etc complete all as specified and as directed. (NOTE :- windows and ventilator are provided with stiles and rails as specified in SSR Part -I)
S & F 40 mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F 3.0 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5 sq mtr in each pane complete all as specified and as directed.
S&F in repair Stainless steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
Taking down cement plaster on brick/stone/concrete surface including wall tiling and hacking out joints hacking for key scrubbing down with water etc complete
M & L rendering 15mm thick on surface of brick work/concrete surface in CM 1:6 and is to be finished even and smooth with out using extra cement complete all as specified directed
M & L for 10mm thick cement plaster in CM 1:4 on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) etc. complete all specified and directed.
M & L for 5mm thick cement plaster in CM 1:4 on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) etc. complete all specified and directed.
M & L for 100mm internal diameter of pipe in mm, salt-glazed stoneware drain pipes laid in trenches and jointed as specified
M&L for 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft and loose soil complete all specified and directed.
Returning, filling in including spreading, leveling , watering and well ramming in layers not exc 25 cm in any stata complete all as specified and directed.
Removing excavated in any statra to distance not exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed.
M & L for PCC (1:3:6) type C2 concrete bed to drain pipes of dia 100mm dia including packing under and haunching against the sides of pipes after they laid and tested.as reqd on ground condition complete all specified and directed.
M & L for PCC (1:3:6) type C2 concrete bed to drain pipes of dia 150mm dia including packing under and haunching against the sides of pipes after they laid and tested.as reqd on ground condition complete all specified and directed.
M & L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required 150mm Dia complete all as specified and directed. ( Note : Work in Foule Position
Demolition and breaking up drain pipes (Salt glazed ware /PVC/ AC or Reinforced concrete) set in cement mortar (75mm dia, 100mm dia) all as specified and directed.
S&F 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors complete all specified and directed.
Ditto all as per Ser Item No 94.00 as above but 110mm dia complete all specified and directed.
M&L for PVC (SWR) bends of any radius with oval and access door of 75mm dia complete all specified and directed.
Ditto all as per Ser Item No 96.00 as above but 110mm dia complete all specified and directed.
M&Lfor PVC (SWR) vent cowl of 75mm dia complete all specified and directed.
S&F in repair PVC(SWR) Nahani trap with grating of diameter of outlet 75mm including jointing to waste pipe fixed in cement concrete type B1 (1:2:4).
M&L(SWG) gully trap 125/110mm setting and jointing with solvent cement all as specified and directed.
S & F Grating doom 100mm dia of Stainless steel with holes/without holds for waste pipes all as specified and directed.
Demolition of stone / block masonry built in CM all as specified and directed.
M&L for precast solid cement concrete block masonry exc 10cm in width built with and setting in mortar complete type C1 (1:3:6 mix) and set in CM (1:6) all as specified and directed.
M and L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement motar 1:4 all as specified and directed.
M & L for Walling of random rubble,uncoursed random rubble,uncoursed, well bonded, bedded and solidly hearted, for random or polygonal rubble walling, brought up to course built in cement motar 1:4 complete all specified and directed.
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers any number of coats any width or girth complete all specified and directed.
M & L for Preparation of old painted wooden surfaces of any description having width/girth exceeding 10cm and applying one coat of synthetic enamel paint for material and labour complete all specified and directed.
M & L for Preparation of new wooden surfaces of any description having width/girth exceeding 10cm and applying two coats of synthetic enamel paint over pink primer for material and labour complete all specified and directed.
M & L for Complete removal of existing treatment on walls all as specified and directed.
M&L for 1mm thick wall care putty on wall all as specified and directed by Engr in Charge.
M & L for distemepring with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre of approved munufacutre of required shade and colour complete as sper munufacuters specification two or more coat on new work all as specified and directed.
M & L for Preparing surfaces plastered or unplastered, washing, rubbing, down and stopping of destempered and painted surfaces for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than than 50gm/litre and UV resistance as per IS 15489:2004 Alkali and fungal resistance, dirt resistance exterior paint or required shade with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.9 litre/10 sqm over new surfaces/old surfaces of wall all as specified and directed.
M & L for Preparation of old plastered surfaces/un plastered surfaces including brooming down with steel wire brushing scrapping down smoke spout moulds, moss and efflorescence, salt treating oil and greasy spots etc and applying two coat of white washing on old plastered surfaces of walls all as specified.
Ditto all as per Ser Item No 113.00 above but on surface of on ceiling /soffits of slabs, chajjas complete all specified and directed.
M & L for Preparation of old painted steel/iron surfaces of any description having width/girth exceeding 10cm and applying one coat of synthetic enamel paint all as specified and directed.
M & L for Preparation of new painted steel/iron surfaces of any description having width/girth exceeding 10cm and applying two coat of synthetic enamel paint over a coat of red oxide complete all specified and directed.
M & L for French polishing on wooden surface of any description including cleaning and preparing the surfaces with a coat of wood filler and two or more coats of French polishing till the desired finish is obtained complete all specified and directed.
M & L for PCC 1:3:6 type C2 (40mm garded aggregate) Cement concrete in surface channels and drains all as specified and directed.
M&L for PCC type D-2(1:4:8) using 40mm graded crushed aggregate as mass conc and filling of foundation complete all specified and directed.
S & F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 15mm dia complete all specified and directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 20mm dia complete all specified and directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 25mm dia complete all specified and directed.
M&L for GI tubing 15mm dia medium grade with all fittings & fixed complete to walls & ceiling or laid in floors in repairs complete all specified and directed.
Fixing only 15mm dia tubes, any grade, to walls and ceilings or laying in floors complete all specified and directed.
M&L for GI tubing 20mm dia medium grade with all fittings & fixtures complete laid in trenches fixed in repairs complete all specified and directed.
Fixing only 20mm dia tubes, any grade, to walls and ceilings or laying in floors complete all specified and directed.
M&L for GI tubing 25mm dia medium grade with all fittings & fixtures complete laid in trenches fixed in repairs complete all specified and directed.
Fixing only 25mm dia tubes, any grade, to walls and ceilings or laying in floors complete all specified and directed.
M&L for cutting chases, pinning in making good to face for concealed water tubing complete all specified and directed.
S&F vitreous chinaware EWC including connection to drain or outgoing pipe and to PVC flushing pipe, antisyphonage pipe, PVC low level flushing cistern 10 ltr capacity with brackets of approval Make and all necessary fittings etc complete all specified and directed incl PVC seat cover fixed in repair
S&F Florentine Single Lever Surgical Purpose Elbow Action Basin Mixer with Extended Operating Lever without Popup Waste System with 450mm Long Braided Hoses all as specified and directed ( Model No FLR-5033B)
S&F in repair 15 mm dia CP brass PVC connection 45 cm long including check nuts etc complete all as specified and directed
M&L Florentine Bib Cock with Extended Lever Handle and Wall Flange all as sepecified and directed.(Model No ;FLR-5043N)
Dismantling of PVC water tanks of 500 ltr capacity and removing to store and all as specified and directed by Engr-in-Charge.
Demolition of RCC water tanks of 2000 ltr capacity removing from roof slab and all as specified and directed by Engr-in-Charge.
S&F rotational moulded polyethylene water storage tank 500 Litres capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I with 25 mm ball valve high pressure PTMT with rod & high density plastic ball complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tank of 1000 ltr capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I with 25 mm ball valve high pressure PTMT with rod & high density plastic ball complete all as specified and directed by Engineer-in-Charge.
S & F in repair PVC low level flushing cistern plastic valve with inlet ball valve float chain and ball (of capacity 10 liters) ISI Marked incl 32mm PVC flush pipe complete all as specified and directed
S & F Vitreous China wash basin, white, flat back, size 550x450 (for Hospilal use) including CP Pillar taps (Surgical type), waste, chain and plug and porcelain stopper but including brackets,450mm PVC connection with barass screws, waste coupling, 32 mm dia all as specified and as directed.
S & F Oval type size 550x450mm wash hand basin white fixing in granite as well as cudappa slab inclduing provding CP Pillar taps (Surgical type), PVC waste pipe 32mm dia ,chromium plated, brass waste coupling 32mm dia all as specified and directed (For Officer toilets only).
S & F in repair stop valves/angle valves fancy , cast copper alloy,screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specified and directed.
S &F Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed
S &F F Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe all as specified and directed
S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified .
S &F Two way bib cock with wall flange 15mm dia all as specified and directed.
S &F in repair brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges all as specified and directed.
S & F stainless steel fancy type curtain rod 20 mm bore including fixing and two sides brackets all as specified & as directed.
Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of 200m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination all as specified and directed.
M & L Providing precast cement concrete type B1 1:2:4 (20mm graded aggregate) in landings cover slabs, (for manholes etc) chullah hoods, chajjas, water toughs mangers shelves and similar articles with plain face and set in CM 1:4 complete all specified and directed.
S &F TMT Bars Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all specified and directed.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor Flame retardant PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets all a specified and directed
One light point controlled by one switch .
One Fan point controlled by one regulator/switch.
One 3 pin socket 5 A on independent board.
One 3 pin socket 5 A on the same switch board.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded Flame retardant PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board) ISI marked (IS 14782) for housing one 15 A Switch / sockets all a specified and directed
S&F ceiling rose surface bakelite 65mm, three terminals (ISI marked) as specified
Supply and fix Modular switch 1 way 6A,1 module
Supply and fix Modular switch 1 way 16A,1 module
Supply and fix Modular Socket, 6A - 2/3 pin combined 2 module
Supply and fix Modular Socket 6A/16A - 2/3 pin combined2 module
Supply and fix Modular Fan step regulator, 120W - 2 module
Supply and fix Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings
Taking down old unsv fluoroscent PL type square fitting and Supply and fix in replacement LED recessed light 2’ x 2’, 32-34 Watt in white powder coated CRCA housing with driver complete with system lumen output not less than 100 lumen per watt complete all as specified and as directed.
Taking down old fluoroscent tubelight along with fixture and Supply & fix LED tube light along with fixture, 1x20 W( 4 feet long) surface and wall mounted LED batten, extruded aluminium housing & integrated electronic drive including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal complete as specified and directed.
Taking down old fluoroscent tubelight along with fixture Supply & fix LED tube light along with fixture, 1x10 W( 2 feet long) surface and wall mounted LED batten, extruded aluminium housing & integrated electronic drive including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal complete all as specified and directed.
Taking down of old unsv security light and Supply & fix LED security light fitting 30 Watt with Energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device including bracket made out of GI pipe with clamps, nut bolts, 3 core wire for connection from looping box/ connector complete all as specified and directed.
Taking down ceiling fan single phase 240 V 1200 mm /1400mm sweep from the existing position including disconnecting supply cable from ceiling rose / connector opening ceiling fan carefully and cleaning and washing the bearings /bushs thoroughly and applying necessary lubricants parts, painting etc and hanging in original position connecting and testing complete on completion of civil works of Bldg all as specified and directed by Engr-in-Charge
Supply and fix wall mounted fan 400 mm sweep with complete wiring and other fixing accessories as per requirement at site.
Taking down old unserviceable exhaust fan of any size and shape, deposit in MES store and Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm
Taking down old unserviceable exhaust fan of any size and shape, deposit in MES store and Supply and fix exhaust fan, steel body heavy duty type AC single Phase 230V of size 300mm sweep with blades, frame and louvers
Taking down of old rusted DBs and S&F VTPN DB 4 way double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof 4 way IP 43 protection, isolated neutral bus bar, insulated bus bar assembly, door earthing, mechanical impact strength IK09 and sitable for MCCB upto 125Amps.
Taking down of old rusted DBs and Supply and fixing MCB DB SPN 12 way with bus bar IP 43-IK-09 with metal double door suitable for housing of MCBs complete all as directed by Engineer-in- Charge.
Taking down of old rusted DBs and Supply and fixing MCB DB SPN 8 way with bus bar IP 43-IK-09 with metal double door suitable for housing of MCBs complete all as directed by Engineer-in- Charge.
Supply and fixing of MCCB 4P, 125 amps, 10KA, Ics=100%Ics, Fixed Thermal & Fixed Magnetic setting with complete connections etc all as specified and directed by Engr-in-Charge.
S&F MCB DP 40 to 63 Amp 10 kA 240 Volt, 'C' Curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge.
M&L for MCB SP 6-32 Amps C curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge.
Taking down old submain wiring and M & L for sub main wiring with two runs of single core 6.0 Sq mm FLRSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4.0 Sq mm single core Flame retardant PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC CONDUIT with all fttiing & fixtures all as directed and specified. (Note:- Two runs of 6.0 Sqmm copper cable and one run of 4 sqmm copper cable including PVC CONDUIT shall be measured and paid as one length)
Taking down old submain wiring and M & L for sub main wiring with two runs of single core 4.0 Sq mm FLRSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 2.5 Sq mm single core Flame retardant PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC CONDUIT with all fttiing & fixtures all as directed and specified. (Note:- Two runs of 4 Sqmm copper cable and one run of 2.5 sqmm copper cable including PVC CONDUIT shall be measured and paid as one length)
Taking down old submain wiring and M & L for sub main wiring with two runs of single core 2.5 Sq mm FLRSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 1.5 Sq mm single core Flame retardant PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC CONDUIT with all fttiing & fixtures all as directed and specified. (Note:- Two runs of 2.5 Sqmm copper cable and one run of 1.5 sqmm copper cable including PVC CONDUIT shall be measured and paid as one length)
M & L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, checknuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plate No. 3 of SSR Part I of 1991 & testing complete including 15mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , funnel, wire mesh with GI watering pipe etc.
Material and labour for taking down serviceable split AC of capaicty upto 2.0 TR from one location and re-install the same at another location including fixing brackets, gas charging, brazing and additional 10 feet of copper piping etc all as specified and directed
Taking out of old unserviceable UG cable and Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified for following size:-
50 sqmm 3.5 core
185 sqmm 3.5 core
240 sqmm 3.5 core
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc.
Hard/dense soil
Soft/disintegrated rock
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. [Note : Measuremenet will be done after punning]
Supplying and laying un-reinforced precast concrete cable cover, class I, flat, size 250mm x 150mm x 40mm for cable protection
Taking down old LT panel from site and Supply, Install, Test and Commissioning of LT feeder pillar box of outdoor type fabricated out of 3 mm thick CRCA sheet double door(front & back opening), panel shall be fabricated from CPRI approved manufacturer complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a) Copper bus bar 600 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (b) On load Manual Change Over switch of range 630 Amps 4P- 01 Nos (For two incoming cables) (c ) MCCB FP 250 Amps 25 KA - 01 No (Outgoing for Dental LT Panel) (d) MCCB FP 160 Amps 25 KA - 01 No (Outgoing for SMC) (e) MCCB FP 100 Amps 25 KA - 02 Nos (Outgoing for O2 Plant, Education Sec (f) MCB FP 63 Amp 'C' Curve - 02 Nos (Stadium, spare) (g) LED indicator for RYB of size 22.5 mm - Set of 3 (h) 3 Phase Digital voltmeter CL 1 -01 nos (i) 3 Phase Digital ammeter CL1 -01 Nos
Taking down old LT panel from site and Supply, Install, Test and Commissioning of LT feeder pillar box of outdoor type fabricated out of 3 mm thick CRCA sheet double door(front & back opening), panel shall be fabricated from CPRI approved manufacturer complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a) Copper bus bar 600 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (b) Onload Manual Change Over switch of range 630 Amps 4P- 01 Nos (For two incoming cables) (c ) MCCB FP 320 Amps 65 KA - 02 No (Outgoing for Main cable and Standby cable) (d) LED indicator for RYB of size 22.5 mm - Set of 3 (e) 3 Phase Digital voltmeter CL 1 -01 nos (f) 3 Phase Digital ammeter CL1 -01 Nos
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), of size 900x 900mm x 400mm, panel shall be fabricated from CPRI approved manufacturer complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a)Aluminium bus bar 400 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (a) MCCB FP 200 Amps 50 KA - 01 No for Main incoming (b) LED indicator for RYB of size 22.5 mm - 01 Set (c) 3 Phase Digital voltmeter -01 nos (d) 3 Phase Digital ammeter-01 Nos Note for Srl Item No 186.00, 187.00 and 188.00: The contractor shall submit layout drawing of LT panel and shall be approved by GE before fabrication.
Supply, Install, Test and Commissioning of LT feeder pillar box of outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a) 200 Amp FP Manual Changeover-01 Nos FOR DENTAL WORKING AND STANDBY CABLE
Supply and fix GI Pipe Light grade with all connected accessories of sizes 50 mm dia complete all as specified and directed by Engr-in-Charge.
Supply and fix GI Pipe Light grade with all connected accessories of sizes 100 mm dia complete all as specified and directed by Engr-in-Charge.
M& L for cutting existing road /hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying GI tubing , returning filling & well raming watering finish surfae 10 cm from top
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified.
Supply install testing and commissioning of 5 Star rated inverter AC having 2.0 TR capacity, precision cooling technology, dual rotor invertor compressor, BLDC motor, filters, cold plasma technology, 100% copper coils of indoor, outdoor including installation kit for indoor and outdoor unit, extra length of refrigrent copper piping, coard cable, drain pipe as red at site. Refrigrent shall be echo friendly (R-410A, R-32) complete all as specified and directed by Engr-in-Charge.
Supply and fixing of voltage stabilizer for automatic operation, single phase, copper wounded, naturally air cooled indoor type & design for input variation between 150 V to 275 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and capacity 5.0 KVA complete on wall
S&F sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 06 to 32 Amps.
M & L for sub main wiring with two runs of single core 4.0 Sq mm FLRSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4.0 Sq mm single core Flame retardan PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified. (Note:- Two runs of 4 Sqmm copper cable and one run of 4 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length)
Supply, installation and testing of silent Diesel Engine Generating set 415 volts 160 KVA 3 phase, 0.8 power factor 50 Hz, 1500 RPM , engine and alternator as per relavent IS, self excited self regulated brushless AC generator with relay panel and control panel installed including sound proof Acoustic enclosure suitable for ambient condition at Pune, Engine should comply with latest CPCB norms , mounted on a base frame along with Std control panel , fuel tank, Battery with leads, first fill of oil, engine safeties & protections, anti vibration mounting pads and foundation etc in all respect and confirming to condition under BS 5514/2613/5000 ISO 8526/3046 with following:- (i) The capacity of Generator set shall be net after all due derating factors as per relevant ISI standard. (ii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test by IEM or rep of accepting officer. (iii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including one hour on 10% overhead in presence of representative detailed by accepting Officer, all arrangements are to be made by the contractor for tests.
(A). Alternator :- Standard design alternator mounted on base frame rated at 160 KVA net output at site after considering deratings as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited ,self regulated screen protected ,drip proof SPDP enclosure ,brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be inposition to generate supply with frequecy regulation with in + 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613 /5000/ IS - 4722. i) Insualation class - 'H' ii) Excitation : Self Excited iii) Regulation performance: The voltage is kept constant with + 1%, manual voltage adjustment within + 5% iv) Frequency regulation + 1%
(B) Diesel Engine: - Six Cylinder In line, liquid / water cooled, Turbo charged 1500 RPM, Engine should be with electric start, compression ignation, 4 stroke cycle Designed to run continuously at 1500 RPM confirming to IS 10001 / 10002 ISO -3046 . Adequate capacity of Diesel engine suitable for 160 KVA coupled drive independently above alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories ,directly coupled through flexible coupling ,multi cylinder multi stroke direct injection, cold starting as per relevant ISI/BS - 5514 with an overload capacity of 10% for one hour in 12 hours, continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under i) Fly wheel with housing ii) Cooling system :- water cooled radiator type iii) Cooling Water pump : - Centrifugal type belt driven.
iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable as per manufacturer and standard with with MS pipe light grade upto and away two meters hight from top of enclosure including angle iron frame supports from floor to the bottom of exhaust pipe from the enclosure covered with mineral wool of thickness 50MM wrapped with chicken wiremesh of size 2.25 mm and aluminium sheet of 24 SWG to be complete with within the enclosure for safe exhaust without transfering vibration to the walve of the enclosure. Exhaust gas turbo charger type Exhaust manifold Silencer : Residential type Bellows v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch/ nozzles/ governer electronic type capable for 1% speed /frequecy regulation. Fuel filters Fuel hoses vi) Lub oil System :- Lubricating oil filter Lubricating oil pump
vii) Air Intake System :- Air intake Manifold Air cleanler dry type viii) Governer :- Electronic Governer ix) Starting System :- Electric Self starter with maintenance free batteries including battery charging alternator. x) Batteries :- Maintenance free Batteries of suitable capacity complete with copper conductor multi stranded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolite all as specified
(C) Fuel Tank :- Inbuilt service fuel tank of capacity for Eight Hrs continues made out of HR sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base within the acoustic enclosure is inclusive of the cost of DG set and is as per manufactures design.
(D) Auto Main Failure (AMF): Microprocessor based Cubical panel indoor type made out of CRCA sheet of 2 mm thick conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 phase , 4 wire, AC 50 Hz having copper bus bar capacity required to carry current at 1.5 times of rated current of DG set with three phase and half neutral color coded, prewired with copper cable of suitable size all as standard practice of manufacturer specifications incl nacessary hardware, gaskets, ferrule, MS stand and CRCA fabrication etc with the following accessories. INPUT (MAINS) i) Indicating lamp 230 V -02 Nos, (ii) Control MCB SP 6A- 4 Nos (iii) Power Contactor 250 Amp 4 Pole 415 Volt- -01 Nos (iv) MCCB 250 Amp 4 Pole 415 volt 36 kA - 01 Nos (v) VMR 415 Volts -01 (vi) Digital Ammeter ( 0-400)and Voltmeter (0- 500) (vii) Current Transformer 400/5A -03 Nos
INPUT (DG) i) Indicating lamp 230 V -02 Nos, (ii) Control MCB SP 6A- 3 Nos (iii) Power Contactor 250 Amp 4Pole 415 Volt- -01 Nos (iv) MCCB 250 Amp 4 Pole 415 volt 36 kA - 01 Nos (v) Battery Charger 24 V 10 A -01 Nos (vi) DC Digital Ammeter ( 0 - 30 A)and Voltmeter (0 - 30 V) (vii) Current Transformer 400/5A -03 Nos OUT GOING (i) MCCB 250 Amps 4 pole 415 Volts 36 kA -01 Nos ACCESSORIES (i) Auto Manual switch 10 A -01 Nos (ii) Manual Load Switch 10 A 0 01 Nos (iii) Relay 230 V / 24 V - 02 Nos (iv) DC Switch 10 A- 01 Nos (v) Key Switch 10 A -01 (vi) Digital Multi function meters suitable to display of DG : Phase voltage,Line current, frequncy, avarge Voltage, average current, Phase KW,Total KW, KWH, kVA, KVAR ,PF earth leakage current etc
E. Acoustic enclosure: Enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet steel will provide easy access for maintenance, repairs and operation. The enclosure is custom built to suit conditions as per latest CPCB norms. The following itmes are deemed to be included in the rate quoted for all DG sets:- (i) DHPP for testing purpose shall be supplied by the contractor with out any extra cost to Govt (ii) The contractor shall will arrange for artificial load for testing for final testing of DG Set at site (iii) Documents : Standard Documents as per manufacturer specifications such as maintenance & operation, mannual parts, catalogues, display chacts such as maintenance and oil change chart/board etc.
(F) Civil Works :- All civil works including PCC plat form and related to foundations including of panel and equipments including making good the existing structure of disturbed during installation and commissioning of genset. The depth of the foundation shall be minimum 300mm below ground level and 300mm above the ground or as recommended by the manufacturer.
Mehta Construction Co.
M/s Kirti Enterprises
tulsani associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .