GEMC-511687764662351
Awarded to VAM INSTRUMENT(INDIA) PRIVATE LIMITED
₹58,410
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| pH EC TDS Salinity Meter (PETS) | 372 | - | 1 NOS | ₹58,410 | 58,410 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹58,410Qualified Make: SYSTRONICS
Model: 372 2ND FLOOR S A S HOUSE SAPRU MARG LUCKNOW LUCKNOW | Make: SYSTRONICS
Model: 372 | L1 | Qualified | |
| 2 | L2₹70,400+₹11,990 (20.5%)Qualified Make: SYSTRONICS
Model: SYSTRONICS MODEL-372 47 2 GROUND FLOOR HARIJAN BASTI KONDLI COLONY KONDLI KONDLI NEW DELHI DELHI 110096 | EAST DELHI | DELHI | 110096 | Make: SYSTRONICS
Model: SYSTRONICS MODEL-372 | L2 | Qualified | |
| 3 | L3₹71,850+₹13,440 (23.0%)Qualified Make: ALTIS
Model: DE-301 0 NEAR RAJGHAT BRIDGE LALGANJ ROAD DARIBA RAEBARELI UTTAR PRADESH 229001 | RAE BARELI | UTTAR PRADESH | 229001 | Make: ALTIS
Model: DE-301 | L3 | Qualified | |
| 4 | L4₹75,000+₹16,590 (28.4%)Qualified Make: SYSTRONICS
Model: SYSTROMICS T-372 105 FIRST FLOOR VISHAL TOWER DISTRICT CENTRE JANAKPURI JANAKPURI WEST DELHI DELHI 110058 UDYAM DL 11 0022043 07ASXPS7874B1ZX R M MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110058 | Make: SYSTRONICS
Model: SYSTROMICS T-372 | L4 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
22 Oct 2018, 3:00 pmClosed
Water Quality Meters/Analyzers Water Quality Meters/Analyzers ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TYPE/NOMENCLATURE PROTECTION Type of Meter Analyzer Bench Type Bench Type
Handheld Functional nomenclature Multi Parameter Water Quality Analyzer Dissolved Oxygen Meter
Salinity Meter
ORP Meter
TDS Meter
Turbidity Meter
pH Meter
Multi Parameter Water Quality Analyzer Ingress Protection (Main Unit) NA being Bench Top IP 55
IP 56
IP 57
IP 65
IP 66
IP 67
IP 68
NA being Bench Top Calibration Automatic Manual
Automatic MEASURED WATER QUALITY PARAMETERS Dissolved Oxygen (DO) false true
false DO % Stauration false true
false Conductivity true true
false Resistivity false true
false Salinity true true
false 1/8 Total Dissolved Solids (TDS) true true
false pH true true
false Oxidation Reduction Potential (ORP) true true
false Ammonium false true
false Nitrate false true
false Chloride false true
false Turbidity false true
false Depth false true
false Temperature true true
false Atmospheric Pressure false true
false MEASUREMENT OF DISSOLVED OXYGEN (DO)/DO % Saturation Dissolved Oxygen (DO) measurement Principle NA Optical
Electro Chemical ( Amperometric )
NA Sensor/Probe Electrode Type NA Lifetime Luminiscent for Optical
Polarographic for Electro Chemical
Galvanic for Electro Chemical
NA Measurement Range for DO Content ( in ppm or mg/l ) NA * Resolution ( in ppm or mg/l ) NA * DO Accuracy ( +/- ) 0 * Measurement Range for DO % Saturation ( in % ) NA 0-200
0-400
0-500
0-600
0-800
NA Resolution ( in % ) NA * DO % Accuracy (+/- ) 0 * MEASUREMENT OF CONDUCTIVITY (EC) Conductivity measurement principle Conductive (contacting) Conductive (contacting)
Inductive
NA Sensor Probe/Electrode Type 2 Cell Electrode 2 Cell Electrode
4 Cell Electrode
NA Material of Electrode Platinum Platinum
Titanium
Gold Plated Nickel
Graphite
NA Measurement Range ( in µS/cm ) 0-200 * Resolution ( in mho or 0.01 * 2/8 µS/cm ) EC Accuracy ( +/- ) 0.1 * MEASUREMENT OF RESISTIVITY Resitivity measurement principle NA Conductivity Conversion
NA Lowest Measurement Value for Resistivity (in ohm-cm) NA 0
1
2
5
10
NA Highest Measurement Value for Resistivity (in Mega ohm-cm) NA 1
20
50
100
200
NA Resolution ( in ohm- cm) NA * Resistivity Accuracy(+/- ) 0 * MEASUREMENT OF SALINITY Salinity measurement principle Conductivity Conversion Conductivity Conversion
NA Measurement Range ( in parts per thousand or g/l or PSU) 0-40 * Resolution (in g/l) 0.1 * Salinity Accuracy ( +/- ) 0.02 * MEASUREMENT OF TOTAL DISSOLVED SOLIDS (TDS) TDS measurement principle Conductivity Conversion Conductivity Conversion
NA TDS Measurement Range ( in parts per thousand or g/l ) 0-200 0-100
0-200
NA Resolution ( in g/l ) 0.1 * TDS Accuracy ( +/- ) 1 * MEASUREMENT OF pH pH measurement principle Electro chemical Electro chemical
NA Sensor/Probe Electrode Type Glass Electrode Hydrogen (Platinum) Electrode
Antimony Electrode
Glass Electrode
Ion Selective Electrode (ISE)
NA Number of Sensors Electrodes Combination Electrode (2 Electrode) Single Electrode
Combination Electrode (2 Electrode)
Differential Electrode (3 Electrode)
NA pH Measurement Range 0-14 0-14
NA 3/8 Resolution ( in pH number ) 0.01 * pH Accuracy ( +/- ) 0.01 * MEASUREMENT OF OXIDATION REDUCTION POTENTIAL (ORP) ORP measurement principle Electro chemical Electro chemical
NA Sensor/Probe Electrode Type Platinum Electrode Platinum Electrode
NA Lowest Measurement Value for ORP (in mV ) -2000 -3000
2500
2000
1500
1000
500
0
NA Highest Measurement Value for ORP (in mV ) 2000 3000
NA Resolution ( in ± mV ) 0.1 * ORP Accuracy ( +/- ) 1 * MEASUREMENT OF AMMONIUM Sensor/Probe Electrode Type NA Ion Selective Electrode
NA Measurement Range ( in ppm or mg/l ) NA 0-100
0-300
NA Resolution ( in ppm or mg/l ) NA * Ammonium Accuracy ( +/- ) 0 * MEASUREMENT OF NITRATE Sensor/Probe Electrode Type NA Ion Selective Electrode
NA Resolution ( in ppm or mg/l ) NA * Nitrate Accuracy ( +/- ) 0 * MEASUREMENT OF CHLORIDE Sensor/Probe/Electro de Type NA Ion Selective Electrode
NA Measurement Range ( in ppm or mg/l ) NA 0-400
0-1000
0-1200
0-1500
NA Resolution ( in ppm or mg/l ) NA * Chloride Accuracy ( +/- 0 * 4/8 ) MEASUREMENT OF TURBIDITY Turbidity measurement principle NA Nephelometric measurement according to ISO 7027
Nephelometric measurement according to US EPA 180.1
NA Light Source NA Infrared Led
White light tungsten lamp
NA Measurement of scattered light NA 30 degree scatter nephelometer
90 degree scatter nephelometer
NA Lowest Measurement Value for Turbidity (in FNU or NTU ) NA 0.01
0.05
0.1
0.5
NA Highest Measurement Value for Turbidity (in FNU or NTU ) NA * Resolution ( in FNU or FTU ) NA * Turbidity Accuracy ( +/- ) 0 * MEASUREMENT OF TEMPERATURE Sensor/Probe Type Semi Conductor Based Thermister Semi Conductor Based Thermister
Resistance Temperature (RTD) Detector
NA Lowest Measurement Value for Temperature (˚C) 0 -20
15
NA Highest Measurement Value for Temperature (˚C) 100 * Resolution (˚C) 0.1 * Temperature Accuracy ( +/- ) 1 * MEASUREMENT OF PRESSURE Sensor/Probe Type NA Pressure transducer
NA Lowest Measurement Value for Pressure (in mmHg ) NA * Highest Measurement Value for Pressure (in NA 800
825
850
875
900
950
NA 5/8 mmHg ) Resolution ( in mmHg ) NA * Pressure Accuracy ( +/- ) 0 * MEASUREMENT OF DEPTH Measurement Method NA Water Pressure method
NA Depth Measurement Range (in meters) NA * Length of Cable connecting peobe (inclusive in the scope of supply) 0 * COMPENSATION CORRECTION Temperature correction Automatically compensates for manual input value Automatic
Manual
Automatically compensates for manual input value
NA Salinity Correction Automatically compensates for manual input value Automatic
NA Barometric Pressure correction NA Automatic
NA DISPLAY/STORAGE Type of Display LCD with Backlight * Display Digit Size 8 * Number of Digits in Display 12 * Number of parameters diplayed simultaneously 1 * Memory (in Data Sets) 500 * Internal memory (GB) 0 * In-built GPS false * Date/time Stamp in Entries true * Connectivity interface RS 232 * POWER SOURCE Power Source Mains (230 ±10 Volts 50 Hz AC) * Battery Size
if Non Rechargeable Battery NA * Battery Chemistry
if Rechargeable Battery NA * 6/8 Voltage of each Battery 0 * Number of Batteries required for operation 0 * Number of Batteries Inclusive in the Scope of Supply 0 * Battery Capacity (mAh) 0 * Battery Life 0 * Suitable Adapter to be supplied to make the equipment Work on 230 V ± 10 %
50 Hz true * GENERIC Armour housing of Sensor/Probe Plastic * Probe/Sensor Electrode supplied with equipment true * Number of elctrodes supplied 2 * Weight 3000 * Dimensions ( mm x mm x mm ) - * Carry Case included in the scope of supply false * Any other features - * List of Items and Quantity of each item included in the offer - * OPERATING CONDITIONS Minimum Operating Temperature 0 0
20 Maximum Operating Temperature 70 50
55
60
70 Operating Humidity
Rh at 40 deg C 85 65
70
75
80
85
90
95 WARRANTY Warranty on Equipment 1 1
3
4
6 Warranty on Probe Electrode 6 6
12
18
24
30
36
48 Warranty on Cables for Connecting Probe 1 1
5 CERTIFICATION Availability of Test Reports from Central Govt/NABL approved/ILAC accredited Lab to prove conformity to false true
false 7/8 the specification If Yes
Test Report to be furnished to the Buyer on demand NA * Test Report No and Date - * Name of the Lab and Address - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ramesh Chand Meena N 321303
ICAR-Directorate Rapeseed Mustard Research
Sewar 1 15
727434
GEM/2018/B/102595
GeM Contract
Water Quality Meters / Analyzers
GeM Contract
15 days
Rajasthan; Bharatpur
PRODUCT
Awarded to VAM INSTRUMENT(INDIA) PRIVATE LIMITED
₹58,410
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| pH EC TDS Salinity Meter (PETS) | 372 | - | 1 NOS | ₹58,410 | 58,410 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Water Quality Meters/Analyzers Water Quality Meters/Analyzers ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TYPE/NOMENCLATURE PROTECTION Type of Meter Analyzer Bench Type Bench Type | - | - | - |
| Handheld Functional nomenclature Multi Parameter Water Quality Analyzer Dissolved Oxygen Meter | - | - | - |
| Salinity Meter | - | - | - |
| ORP Meter | - | - | - |
| TDS Meter | - | - | - |
| Turbidity Meter | - | - | - |
| pH Meter | - | - | - |
| Multi Parameter Water Quality Analyzer Ingress Protection (Main Unit) NA being Bench Top IP 55 | - | - | - |
| IP 56 | - | - | - |
| IP 57 | - | - | - |
| IP 65 | - | - | - |
| IP 66 | - | - | - |
| IP 67 | - | - | - |
| IP 68 | - | - | - |
| NA being Bench Top Calibration Automatic Manual | - | - | - |
| Automatic MEASURED WATER QUALITY PARAMETERS Dissolved Oxygen (DO) false true | - | - | - |
| false DO % Stauration false true | - | - | - |
| false Conductivity true true | - | - | - |
| false Resistivity false true | - | - | - |
| false Salinity true true | - | - | - |
| false 1/8 Total Dissolved Solids (TDS) true true | - | - | - |
| false pH true true | - | - | - |
| false Oxidation Reduction Potential (ORP) true true | - | - | - |
| false Ammonium false true | - | - | - |
| false Nitrate false true | - | - | - |
| false Chloride false true | - | - | - |
| false Turbidity false true | - | - | - |
| false Depth false true | - | - | - |
| false Temperature true true | - | - | - |
| false Atmospheric Pressure false true | - | - | - |
| false MEASUREMENT OF DISSOLVED OXYGEN (DO)/DO % Saturation Dissolved Oxygen (DO) measurement Principle NA Optical | - | - | - |
| Electro Chemical ( Amperometric ) | - | - | - |
| NA Sensor/Probe Electrode Type NA Lifetime Luminiscent for Optical | - | - | - |
| Polarographic for Electro Chemical | - | - | - |
| Galvanic for Electro Chemical | - | - | - |
| NA Measurement Range for DO Content ( in ppm or mg/l ) NA * Resolution ( in ppm or mg/l ) NA * DO Accuracy ( +/- ) 0 * Measurement Range for DO % Saturation ( in % ) NA 0-200 | - | - | - |
| 0-400 | - | - | - |
| 0-500 | - | - | - |
| 0-600 | - | - | - |
| 0-800 | - | - | - |
| NA Resolution ( in % ) NA * DO % Accuracy (+/- ) 0 * MEASUREMENT OF CONDUCTIVITY (EC) Conductivity measurement principle Conductive (contacting) Conductive (contacting) | - | - | - |
| Inductive | - | - | - |
| NA Sensor Probe/Electrode Type 2 Cell Electrode 2 Cell Electrode | - | - | - |
| 4 Cell Electrode | - | - | - |
| NA Material of Electrode Platinum Platinum | - | - | - |
| Titanium | - | - | - |
| Gold Plated Nickel | - | - | - |
| Graphite | - | - | - |
| NA Measurement Range ( in µS/cm ) 0-200 * Resolution ( in mho or 0.01 * 2/8 µS/cm ) EC Accuracy ( +/- ) 0.1 * MEASUREMENT OF RESISTIVITY Resitivity measurement principle NA Conductivity Conversion | - | - | - |
| NA Lowest Measurement Value for Resistivity (in ohm-cm) NA 0 | - | - | - |
| 1 | - | - | - |
| 2 | - | - | - |
| 5 | - | - | - |
| 10 | - | - | - |
| NA Highest Measurement Value for Resistivity (in Mega ohm-cm) NA 1 | - | - | - |
| 20 | - | - | - |
| 50 | - | - | - |
| 100 | - | - | - |
| 200 | - | - | - |
| NA Resolution ( in ohm- cm) NA * Resistivity Accuracy(+/- ) 0 * MEASUREMENT OF SALINITY Salinity measurement principle Conductivity Conversion Conductivity Conversion | - | - | - |
| NA Measurement Range ( in parts per thousand or g/l or PSU) 0-40 * Resolution (in g/l) 0.1 * Salinity Accuracy ( +/- ) 0.02 * MEASUREMENT OF TOTAL DISSOLVED SOLIDS (TDS) TDS measurement principle Conductivity Conversion Conductivity Conversion | - | - | - |
| NA TDS Measurement Range ( in parts per thousand or g/l ) 0-200 0-100 | - | - | - |
| 0-200 | - | - | - |
| NA Resolution ( in g/l ) 0.1 * TDS Accuracy ( +/- ) 1 * MEASUREMENT OF pH pH measurement principle Electro chemical Electro chemical | - | - | - |
| NA Sensor/Probe Electrode Type Glass Electrode Hydrogen (Platinum) Electrode | - | - | - |
| Antimony Electrode | - | - | - |
| Glass Electrode | - | - | - |
| Ion Selective Electrode (ISE) | - | - | - |
| NA Number of Sensors Electrodes Combination Electrode (2 Electrode) Single Electrode | - | - | - |
| Combination Electrode (2 Electrode) | - | - | - |
| Differential Electrode (3 Electrode) | - | - | - |
| NA pH Measurement Range 0-14 0-14 | - | - | - |
| NA 3/8 Resolution ( in pH number ) 0.01 * pH Accuracy ( +/- ) 0.01 * MEASUREMENT OF OXIDATION REDUCTION POTENTIAL (ORP) ORP measurement principle Electro chemical Electro chemical | - | - | - |
| NA Sensor/Probe Electrode Type Platinum Electrode Platinum Electrode | - | - | - |
| NA Lowest Measurement Value for ORP (in mV ) -2000 -3000 | - | - | - |
| 2500 | - | - | - |
| 2000 | - | - | - |
| 1500 | - | - | - |
| 1000 | - | - | - |
| 500 | - | - | - |
| 0 | - | - | - |
| NA Highest Measurement Value for ORP (in mV ) 2000 3000 | - | - | - |
| NA Resolution ( in ± mV ) 0.1 * ORP Accuracy ( +/- ) 1 * MEASUREMENT OF AMMONIUM Sensor/Probe Electrode Type NA Ion Selective Electrode | - | - | - |
| NA Measurement Range ( in ppm or mg/l ) NA 0-100 | - | - | - |
| 0-300 | - | - | - |
| NA Resolution ( in ppm or mg/l ) NA * Ammonium Accuracy ( +/- ) 0 * MEASUREMENT OF NITRATE Sensor/Probe Electrode Type NA Ion Selective Electrode | - | - | - |
| NA Resolution ( in ppm or mg/l ) NA * Nitrate Accuracy ( +/- ) 0 * MEASUREMENT OF CHLORIDE Sensor/Probe/Electro de Type NA Ion Selective Electrode | - | - | - |
| NA Measurement Range ( in ppm or mg/l ) NA 0-400 | - | - | - |
| 0-1000 | - | - | - |
| 0-1200 | - | - | - |
| 0-1500 | - | - | - |
| NA Resolution ( in ppm or mg/l ) NA * Chloride Accuracy ( +/- 0 * 4/8 ) MEASUREMENT OF TURBIDITY Turbidity measurement principle NA Nephelometric measurement according to ISO 7027 | - | - | - |
| Nephelometric measurement according to US EPA 180.1 | - | - | - |
| NA Light Source NA Infrared Led | - | - | - |
| White light tungsten lamp | - | - | - |
| NA Measurement of scattered light NA 30 degree scatter nephelometer | - | - | - |
| 90 degree scatter nephelometer | - | - | - |
| NA Lowest Measurement Value for Turbidity (in FNU or NTU ) NA 0.01 | - | - | - |
| 0.05 | - | - | - |
| 0.1 | - | - | - |
| 0.5 | - | - | - |
| NA Highest Measurement Value for Turbidity (in FNU or NTU ) NA * Resolution ( in FNU or FTU ) NA * Turbidity Accuracy ( +/- ) 0 * MEASUREMENT OF TEMPERATURE Sensor/Probe Type Semi Conductor Based Thermister Semi Conductor Based Thermister | - | - | - |
| Resistance Temperature (RTD) Detector | - | - | - |
| NA Lowest Measurement Value for Temperature (˚C) 0 -20 | - | - | - |
| 15 | - | - | - |
| NA Highest Measurement Value for Temperature (˚C) 100 * Resolution (˚C) 0.1 * Temperature Accuracy ( +/- ) 1 * MEASUREMENT OF PRESSURE Sensor/Probe Type NA Pressure transducer | - | - | - |
| NA Lowest Measurement Value for Pressure (in mmHg ) NA * Highest Measurement Value for Pressure (in NA 800 | - | - | - |
| 825 | - | - | - |
| 850 | - | - | - |
| 875 | - | - | - |
| 900 | - | - | - |
| 950 | - | - | - |
| NA 5/8 mmHg ) Resolution ( in mmHg ) NA * Pressure Accuracy ( +/- ) 0 * MEASUREMENT OF DEPTH Measurement Method NA Water Pressure method | - | - | - |
| NA Depth Measurement Range (in meters) NA * Length of Cable connecting peobe (inclusive in the scope of supply) 0 * COMPENSATION CORRECTION Temperature correction Automatically compensates for manual input value Automatic | - | - | - |
| Manual | - | - | - |
| Automatically compensates for manual input value | - | - | - |
| NA Salinity Correction Automatically compensates for manual input value Automatic | - | - | - |
| NA Barometric Pressure correction NA Automatic | - | - | - |
| NA DISPLAY/STORAGE Type of Display LCD with Backlight * Display Digit Size 8 * Number of Digits in Display 12 * Number of parameters diplayed simultaneously 1 * Memory (in Data Sets) 500 * Internal memory (GB) 0 * In-built GPS false * Date/time Stamp in Entries true * Connectivity interface RS 232 * POWER SOURCE Power Source Mains (230 ±10 Volts 50 Hz AC) * Battery Size | - | - | - |
| if Non Rechargeable Battery NA * Battery Chemistry | - | - | - |
| if Rechargeable Battery NA * 6/8 Voltage of each Battery 0 * Number of Batteries required for operation 0 * Number of Batteries Inclusive in the Scope of Supply 0 * Battery Capacity (mAh) 0 * Battery Life 0 * Suitable Adapter to be supplied to make the equipment Work on 230 V ± 10 % | - | - | - |
| 50 Hz true * GENERIC Armour housing of Sensor/Probe Plastic * Probe/Sensor Electrode supplied with equipment true * Number of elctrodes supplied 2 * Weight 3000 * Dimensions ( mm x mm x mm ) - * Carry Case included in the scope of supply false * Any other features - * List of Items and Quantity of each item included in the offer - * OPERATING CONDITIONS Minimum Operating Temperature 0 0 | - | - | - |
| 20 Maximum Operating Temperature 70 50 | - | - | - |
| 55 | - | - | - |
| 60 | - | - | - |
| 70 Operating Humidity | - | - | - |
| Rh at 40 deg C 85 65 | - | - | - |
| 70 | - | - | - |
| 75 | - | - | - |
| 80 | - | - | - |
| 85 | - | - | - |
| 90 | - | - | - |
| 95 WARRANTY Warranty on Equipment 1 1 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 6 Warranty on Probe Electrode 6 6 | - | - | - |
| 12 | - | - | - |
| 18 | - | - | - |
| 24 | - | - | - |
| 30 | - | - | - |
| 36 | - | - | - |
| 48 Warranty on Cables for Connecting Probe 1 1 | - | - | - |
| 5 CERTIFICATION Availability of Test Reports from Central Govt/NABL approved/ILAC accredited Lab to prove conformity to false true | - | - | - |
| false 7/8 the specification If Yes | - | - | - |
| Test Report to be furnished to the Buyer on demand NA * Test Report No and Date - * Name of the Lab and Address - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ramesh Chand Meena N 321303 | - | - | - |
| ICAR-Directorate Rapeseed Mustard Research | - | - | - |
| Sewar 1 15 | - | - | - |
Exempted
25 Oct 2018
11 Oct 2018
contract_GEMC-511687764662351.pdf
GEM_CONTRACT • 0.03 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_727434.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .