Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC LOKMAT BHAWAN A WING 808 WARDHA ROAD RAMDASPETH NAGPUR 440010 | NAGPUR | MAHARASHTRA | 440010 | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹11.7 L+₹80,297 (7.36%)Rejected-AOC 142 JAGJIVANRAM NAGAR GAROBA MAIDAN NAGPUR 440008 | NAGPUR | NAGPUR | MAHARASHTRA | 440008 | L2 | Rejected-AOC Not being the lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
15 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) AF Sonegaon, Nagpur
Bldg P-51, 44 Wings AF Station Sonegaon, Nagpur-440005
REPAIR/ MAINTENANCE OF COOLING APPLIANCES AND LED SECURITY LIGHTS IN TXR AND TECHNICAL AREA AT AFS SONEGAON, NAGPUR
2023_MES_635104_1
8498/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Sonegaon
As per NIT
8 documents required · 8 mandatory
₹500
AGE (I) AF Sonegaon
₹20,000
Yes
7 Mar 2024
30 Dec 2023
22 Feb 2024
30 Dec 2023
15 Feb 2024
13 Jan 2024
30 Dec 2023 - 6 Jan 2024
Amount
S&F in repairs starting capacitor of cap 80/100 MFD 440 Volts Air Conditioner & fixing in position testing etc complete all as specified and directed.
S & F in repairs running capacitor of cap 36/45 MFD 440 V AC & fixing in position testing etc complete all as specified and directed.
S& F in repairs over load relay suitable for AC split 1.5 ton & fixing in position & testing etc complete all as specified and directed.
S & F in repairs thermostat suitable for AC split type 1.5 ton fixing in position etc complete all as specified and directed.
S & F in repairs thermostat suitable for AC split type 2 ton fixing in position etc complete all as specified and directed.
M & L for refrigerant gas charging with R-22 suitable for 1.5/2TR Ton AC including cutting of copper tubes soldering & fixing in position complete all as specified and directed.
S & F in repairs sealed/unit compressor with full charging of gas F-12/ R-22 factory winded ( Make : Kirloskar/Shriram or equivalent) suitable for AC 1.5 /2 Ton split type or equivalent including transporting to civil work shop & bring back at site & fixed in position & testing etc all as specified and directed.
S & F fan motor 230 V suitable for AC 1.5 ton split type complete all as specified and directed. (any capacity)
S & F fan motor 230 V suitable for AC 2 ton split type complete all as specified and directed. ( any capacity )
S & F in repairs filter element suitable for AC 1.5 ton Split type of any make complete all as specified and directed.
S & F in repairs filter element suitable for AC 2 ton Split type of any make complete all as specified and directed.
S & F in repairs blower unit for A/C 1.5 ton,/2 Ton of split type complete all as specified and directed.
S& F in repairs remote control suitable for AC split type cap 1.5 ton, 2ton & 3 ton of split type complete all as specified and directed.
M & L for disconnecting unserviceable and corroded top cover of AC split type outer unit of any capacity including replacement with new top cover made out of 02 mm thick MS CRC sheet with necessary bolt, nuts & washers duly painted as per existing complete all as specified and directed.
S&F in repair PCB circuits for ACs 1.5, 2 TR complete all as specified and directed.
S&F in repair PCB circuits(outer unit PCB) for inverter base AC cap 1.5/2 TR outer unit complete all as specified and directed.
M & L for disconnecting outer & inner unit of Air-conditioning unit of any capacity including cutting of copper tubes including shifting of outer unit from roof of the building with provision of angle iron anchor pockets made out of 25mmX25mmX5mm angle iron with suitable size of MS plate with installation of outer & inner unit of AC with the suitable space for further maintenance including necessary gas charging / topping up R-22 with soldering of copper tubes complete all as specified and directed.
S & F in repairs sealed unit compressor with full charging of gas F-12/R134 factory winded suitable for refrigerator 185 ltrs capacity of any make carrying out in civil work shop and bringing it back to site, fixing & testing complete all as specified and directed.
M & L for gas charging with F-12/F-22 or equivalent suitable for refrigerator capacity 165/250/310 Ltrs including cutting of copper tubes soldering & fixing in position complete all as specified and directed.
M & L for gas charging with F-12/F-22 or equivalent suitable for deep freezer of various capacity including cutting of copper tubes soldering & fixing in position complete all as specified and directed.
S & F in repairs sealed unit compressor with full charging of gas F-12/ R134 factory winded of capacity 40/60/80 ( Make Kirloskar / Shriram or equivalent) Model 444, 512, 2612 or equivalent carrying out in civil work shop & bringing back to site & testing for water cooler complete all as specified and directed.
S & F in repairs fan motor 230V single phase 1440 RPM suitable for water cooler 40/60/80 Ltrs and fixing in position etc complete all as specified and directed.
S&F in repairs starting capacitor 80/100 MFD 440- V suitable for water cooler any capacity and fixing in position testing etc complete all as specified and directed.
S & F in repairs capacitor 36 MFD 440 V suitable for water cooler any capacity fixing in position testing etc complete all as specified and directed.
S&F in repairs over load relay suitable for water cooler fixing in position testing etc complete all as specified and directed.
M & L for repairs to water cooler body of any capacity including cutting of corroded portion of MS sheet and making new with MS CRC sheet 22SWG for bottom portion and 24 SWG for upper/body portion,repairing of stand including painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S & F in repairs 15mm ball valves high pressure with polythene float valve and fly nuts complete screwed for iron pipe & fixed for water cooler any capacity complete all as specified and directed.
S & F in repairs stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes for union & fixed of size 15 mm bore complete all as specified and directed.
M & L for refrigerant gas charging with R-12, R-22 or equivalent for water cooler capacity of 40/60/80 Ltrs cap including cutting of copper tubing & soldering etc complete all as specified and directed.
M & L for taking out old unserviceable thermostat from water cooler, supply and fix thermostat complete all as specified and directed.
M & L for opening of voltage stabilizer, repairing/ rewinding of transformer including heating varnishing and replacing of relay of the 5 KVA capacity complete all as specified and directed.
M & L for opening of voltage stabilizer, repairing/ rewinding of transformer including heating varnishing and replacing of relay of the 2 KVA capacity complete all as specified and directed.
M & L for taking out old unserviceable volt meter/ amp meter and Supply & fix volt meter/ amp meter for single phase voltage stabilizer complete all as specified and directed.
M &L for rewinding of fan motor any make any size of desert cooler with super enameled copper wire using with suitable gauge including materials such as insulating paper, varnishing, heating/baking and reassembling testing complete all as specified and directed.
S & F in repair of fan motor including cutting dismantling from desert cooler any size as per site complete all as specified and directed.
S & F in repairs vertical pump for desert cooler with GI clamps suitable Upto 5 feet height discharge coolers etc complete all as specified and directed.
S & F in repairs capacitor 4 MFD suitable for desert cooler of any capacity & testing etc complete all as specified and directed.
S & F suitable pad / grass ribs including packing complete set of three for each cooler complete all as specified and directed.
S & F PVC flexible pipe 15 mm bore suitable to desert cooler any capacity for circulation of water etc complete all as specified and directed.
S & F plug top 5 Amp for electric connection of desert cooler etc complete all as specified and directed.
S & F plug top 15 Amp for electric connection for water coolers, deep freezers etc. complete all as specified and directed.
S & F for ply wood 6 mm thick including painting with two coats of synthetic enamel paint over one coat of primer on one side fixing to window face complete wherever required for desert cooler etc complete all as specified and directed.
M & L for preparation of old surface of desert cooler any make any size internally & externally complete body both internal & external surface with two coats of synthetic enamel paint gray shade over one coat of red oxide primer complete all as specified and directed.
S & F in repair including cutting dismantling desert cooler bottom water storage tank with primer & painting of tank cap upto 80 litre complete all as specified and directed.
S & F in repairs PVC copper cable 1.5 sqmm three core for connection of desert cooler complete all as specified and directed.
S & F single pole with a two pin & earth plug & socket complete with one single pole MCB of capacity 20 Amp complete all as specified and directed.
M&L for split AC's checking /rectification of minor problem including washing,cleaning of outer/inner unit with filter by brushes & servicing of inner & outer unit etc complete all as specified and directed.
M & L for refrigerant gas charging with 410-C( gas green) suitable for 1.5/2TR Ton AC including cutting of copper tubes soldering & fixing in position complete all as specified and directed.
M& L for capillary tube 0.060 inch,0.064 inch & 0.072inch suitable for 1.5 TR & 2TR AC as directed by Engineer -in charge complete all as specified and directed.
S&F in repair thermostat for geyser capacity upto 25 ltrs complete all as specified and as directed.
S&F in repair heating element for geyser capacity upto 25 ltrs complete all as specified and directed.
S&F in repair temperature and pressure valve for geyser capacity upto 25 ltrs complete all as specified and as directed.
S&F isolator switch for geyser capacity upto 25 ltrs complete all as specified and directed.
S&F an overflow pipe for geyser capacity upto 25 ltrs complete all as specified and directed.
Taking down carefully old tube light/MH/HPSV Light fitting , 70/80/150/250/400 watt, unserviceable LED Street light fittings carefully from towers and upto 10 meter poles, after disconnecting the supply, sealing the cable ends for carrying out repairs/maintenance at site/workshop complete all as specified and directed. Note : (i) Spares required for repair of the fitting shall be measured and paid seperately under the item No. 57 here in after as "Supply only". However, the labour cost for taking down spares & fixing shall deemed to be included in the quoted rate. (ii) Unserviceable spare parts shall be contractor's property as per Sch of Credit.
Supply only the spares required for replacement of spares during the process of repair of the light fitting vide SI item No 56 here in before complete all as specified and directed.
(a) LED fittings 70 watt driver
(b) LED fittings 80 watt driver
(c) LED fittings 150 watt driver
(d) LED fittings 200 watt driver
Taking down carefully old security light/MH/HPSV Light fitting , unserviceable LED building security light fittings 20 watt carefully from towers and upto 10 meter poles, after disconnecting the supply, sealing the cable ends for carrying out repairs/maintenance at site/workshop complete all as specified and directed.
Supply only the spares LED fittings 20 watt driver required for replacement of spares during the process of repair of the light fitting vide SI item No 58 here in before complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, stays, laying of UG cable/ pipes & getting out in soft/loose soil complete all as specified and as directed.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
M & L for providing dry river sand as in sand cushioning for underground cable protection including punning down sand in layers complete all as specified & directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supplying and laying common burnt clay sub class ‘B’ bricks of size 230 mm x 115 mm x 75 mm, laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed.
M & L road cutting of size 30 cm width x 45 cm depth for laying of cables including making good the road with necessary returning filling and bituminious portion with concrete and bituminous mixture and cemented portion with PCC in 1:2:4 , 15 cm thick from top and matching with the existing surfaces complete all as specified and directed.
Supplying and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc for protection of cables including taking down complete all as specified and directed
Supplying, laying, testing and Commissioning cable XLPE insulated aluminium conductor,stranded, armoured, PVC sheathed, LT 1100 volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables complete all as specified and directed for the following sizes.
50 sqmm, 3.5 core
25 sqmm, 3.5 core
16 sqmm, 4 core
10 sqmm, 2 core
S&F LED street light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 70 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed.
S&F LED Flood light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 200 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed.
S&F LED Flood light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 80 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed.
S&F LED Flood light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 150 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed.
S & F 20 Watt LED Bldg security light with a nominal system. The luminaire shall have rated system lifetime of 50,000 burning hours at L70. The luminaire should have cool white colour temperature (CCT>5000K) and a CRI>70. The luminaire shall meet IP66 rating with THD<20% & pf>0.9. The luminaire housing should be made of pressure die cast aluminimum. The total power consumption should not exceed 25W (including driver) pre wired fitted on and including two Nos PVC block of suitable size and connection up to tube light fitting with connecting up with copper 3 core flexible cord of minimum size 0.5 Sqmm and testing complete including LED lamp complete all as specified and as directed.
Rectification of cable faults including provision of straight through cable joint LT Epoxy complete with resine and hardner for cable of size 70 Sqmm 3.5 core complete all as specified and directed Make:- M-Seal / Denson / Raychem / Cabseal
All as per Item No 73 here in before but of size 95 Sqmm 3.5 core.
All as per Item No 73 here in before but of size 35 Sqmm 3.5 core.
All as per Item No 73 here in before but of size 25 Sqmm 4 core.
M & L for painting of Steel tubular poles of any size with two coats of aluminum paint including painting to cross arms and clamps etc including preparation of surfaces by scrubbing and cleaning with wire brush and renumbering the existing number of the pole as existing complete all as specified and directed.
M & L for scrapping down rusted, fallen paint from the Electrical LT panel including rail/channel of base using mechanical scrapers, brushes, sand paper etc and removing the old paint on entire outer surfaces and repainting external surfaces with black/yellow (strip) colour with applying a coat of red oxide zinc chrome primer on the both internal & external portion where base metal is exposed, painting spray one coat of synthetic enamel paint for outdoor type panel including MCCB's specific cabinet complete all as specified and directed.
M & L for writing Pole No on PCC/steel poles with white synthetic enamelled paint on black background, size of letter shall be 50 mm or less complete all as specified and directed.
S&F in repairs Isolator TPN 415 volts 63 Amp AC with necessary connection in existing panel/DB BOX complete all as specified and directed.
S&F in repairs Isolator DP 240 volts 40 Amp AC with necessary connection in existing panel/DB BOX complete all as specified and directed.
S&F in repairs MCCBs four pole 415 volts. 16 KA ,100 Amp AC in existing panel board with modification /fabrication of existing panel board as directed by E-in-Charge complete all as specified and directed.
S & F Thermo plastic cable looping boxes, factory made, IP 65 sheet of size 200 x 160 x 98mm seperate detached gland plate and including MCB TPN 20 Amps and bakelite connector 4 way 20 Amp with din rail, weather vermin proof, front door opening with hinge and locking arrangement fixed to pole complete all as specified and directed. Make : Henselelectric/neptune or its equivalent in other makes.
S & F in repairs solar Photovoltaic Panel of 50Wp monocrystalline type complete all as specified and as directed.
karambir constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .