Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | ₹16.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹19.2 L+₹2.7 L (16.4%)Rejected-Finance | ₹19.2 L+₹2.7 L (16.4%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical police verification of Vijendra Doon and Pooja Choudhary not submitted, Bank solvency cerificate is more than 6 months old, working capital certificate not submitted, |
| 4 | Rejected-Technical 261 BHARAT NAGAR BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | - | - | Rejected-Technical Tenderer enlistment validity expired on 31 Dec 2025. |
| Sl No | Description | Qty | Unit | KAY VEE CONSTRUCTIONS L1 | REYANSH GARG AND COMPANY L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5 m wide and not exceeding 1.5 m depth for foundation for laying of cable etc and getting out in soft loose soil all as specified and directed by Engineer-in-Charge. | 142 | Cum | 100 ₹14,200 Lowest | 110 ₹15,620 |
| 2.00 | Returning and filling including spreading leveling watering and well ramming in layeres n exc 25 cm in soil complete all as specified and directed by Engineer-in-Charge. | 68 | Cum | 100 ₹6,800 Lowest | 120 ₹8,160 |
| 3.00 | Removing excavated material n.exc 50 m and deepositing where directed at a level n.exc 1.5 mtr above the starting point as in soil complete all as specified and directed by Engineer-in-Charge. | 74 | Cum | 100 ₹7,400 Lowest | 105 ₹7,770 |
| 4.00 | Material & Labour for dry river sand as in sand cushioning to under ground cable cover including punning down all as specified and directed by Engineer-in-Charge.
Note- Punned thickness of 18 cm shall be measured for 1 Cum | 62 | Cum | 700 ₹43,400 Lowest | 750 ₹46,500 |
| 5.00 | Supply and laying reinforced precast concrete cable cover LV, type I, Flat, size 250mm X 150mm X 40mm complete all as specified and directed by Engineer-in-Charge. | 2,100 | Each | 25 ₹52,500 Lowest | 35 ₹73,500 |
| 6.00 | Supply and laying synethic Rubber insulated mats 2 mm thick for volatge upto 3.3 KV for electrical purpose as per IS : 15652-2006, (supersending IS 5424) suitable for electrical shock safety of size 2m X 1m X 2mm complete all as specified and directed by Enginner-in-Charge. | 5 | Each | 1,000 ₹5,000 Lowest | 1,200 ₹6,000 |
| 7.00 | Supply and fixing DC cable connector (Male and Female) complete set as specified and directed at site by Engineer-in-Charge. | 30 | Each set | 200 ₹6,000 Lowest | 250 ₹7,500 |
| 8.00 | Supply, laying and testing and commissioning of 6 Sqmm DC cable double insulated low voltage UV and weather resistance complete all as specified and directed by Engineer-in-Charge. | 300 | RM | 150 ₹45,000 Lowest | 175 ₹52,500 |
| 9.00 | Supply, laying, testing and commissioning of XLPE insulated single core cable 150 Sqmm suitable for DC Supply all as specified and directed by Engineer-in-Charge. | 107 | RM | 1,000 ₹1,07,000 Lowest | 1,200 ₹1,28,400 |
| 10.00 | Supply, laying, testing and commissioning of XLPE insulated single core cable 240 Sqmm suitable for DC Supply all as specified and directed by Engineer-in-Charge. | 90 | RM | 1,200 ₹1,08,000 Lowest | 1,300 ₹1,17,000 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
11 May 2026, 6:00 pmClosed
HQ CWE(AF) BHISIANA
HQ CWE(AF) BHISIANA
REPAIR AND MAINT OF SOLAR PLANT (1 MW) AT AF STN BHISIANA
2026_MES_761209_1
CWE(BHI)/BHI-84/2025-26
Open Tender
Civil Works
Works
334 days
Bhisiana
As per tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) BHISIANA
₹30,000
Yes
11 Jun 2026
21 Apr 2026
13 May 2026
21 Apr 2026
11 May 2026
5 May 2026
21 Apr 2026 - 24 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Excavation in trenches not exc 1.5 m wide and not exceeding 1.5 m depth for foundation for laying of cable etc and getting out in soft loose soil all as specified and directed by Engineer-in-Charge. | - | Cum | - | - |
| - | Returning and filling including spreading leveling watering and well ramming in layeres n exc 25 cm in soil complete all as specified and directed by Engineer-in-Charge. | - | Cum | - | - |
| - | Removing excavated material n.exc 50 m and deepositing where directed at a level n.exc 1.5 mtr above the starting point as in soil complete all as specified and directed by Engineer-in-Charge. | - | Cum | - | - |
| - | Material & Labour for dry river sand as in sand cushioning to under ground cable cover including punning down all as specified and directed by Engineer-in-Charge.
Note- Punned thickness of 18 cm shall be measured for 1 Cum | - | Cum | - | - |
| - | Supply and laying reinforced precast concrete cable cover LV, type I, Flat, size 250mm X 150mm X 40mm complete all as specified and directed by Engineer-in-Charge. | - | Each | - | - |
| - | Supply and laying synethic Rubber insulated mats 2 mm thick for volatge upto 3.3 KV for electrical purpose as per IS : 15652-2006, (supersending IS 5424) suitable for electrical shock safety of size 2m X 1m X 2mm complete all as specified and directed by Enginner-in-Charge. | - | Each | - | - |
| - | Supply and fixing DC cable connector (Male and Female) complete set as specified and directed at site by Engineer-in-Charge. | - | Each set | - | - |
| - | Supply, laying and testing and commissioning of 6 Sqmm DC cable double insulated low voltage UV and weather resistance complete all as specified and directed by Engineer-in-Charge. | - | RM | - | - |
| - | Supply, laying, testing and commissioning of XLPE insulated single core cable 150 Sqmm suitable for DC Supply all as specified and directed by Engineer-in-Charge. | - | RM | - | - |
| - | Supply, laying, testing and commissioning of XLPE insulated single core cable 240 Sqmm suitable for DC Supply all as specified and directed by Engineer-in-Charge. | - | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
BOQ_852661.xls
BOQ • 0.42 MB
Tender84.pdf
Tender Documents • 1.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .