Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC BHAVANI KRUPA GANDHI CHOWK NAGPUR | NAGPUR | NAGPUR | MAHARASHTRA | 442302 | L1 | Accepted-AOC Being a lowest bidder and reasonable rate quoted | |
| 2 | L2₹37.2 L+₹2.6 L (7.63%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹38.1 L+₹3.5 L (10.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹38.5 L+₹3.9 L (11.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹38.9 L+₹4.4 L (12.6%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
23 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PULGAON
GE PULGAON CAD CAMP
REPAIRS TO RCC ROOF WORK AND OTHER B/R WORKS IN B SUB DEPOT INSIDE DEPOT AT CAD PULGAON
2022_MES_528413_1
8997/PUL/E8
Open Tender
Civil Works
Item Rate
270 days
GE PULGAON
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE PULGAON
₹70,000
Yes
8 Jul 2022
3 Jun 2022
30 Jun 2022
3 Jun 2022
23 Jun 2022
18 Jun 2022
3 Jun 2022 - 17 Jun 2022
Amount
Demolition of cement concrete (un-reinforced) in ground floors and paving n.exc 15 cm thickness (below or above ground level) complete all as specified and directed. Note: 1. For demolition, power for drilling machine, breaker etc will be supplied by mobile generator on own arrangement by contractor 2. Wastage of time for TFF issue from ISO/Fire station (as usage of generator involved) may be considered while quoting
M & L for PCC 1:3:6, 75mm thick type C2 as in plinth protection complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (40mm graded stone agg.) concrete in surface channels and Saucer drains etc complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1, (20mm graded aggregate) as in copings, cills, sesmic and similar bands, plinth courses, string courses,lacing courses, parapet etc including weathering, slightly rounded or chamfered angle and throating and use of formwork complete all as specified and as directed.
M&L for in repairs 75 mm thick PCC 1:4:8 type D2 (Using 40 mm graded stone aggrgate) as in sub base complete all as specified and as directed.
Taking down cement or cement lime plaster of any description from stone/brick or concrete surface of wall/ceiling etc including racking out joints hacking for key scrubbing down with water complete all as specified and as directed.
M & L for rendering 15mm thick in CM 1:6 on fair faces of brick/stone wall or concrete surface finished even and smooth without using extra cement complete all as specified and directed.
M & L for Rendering 10mm thick in CM 1:3 on fair faces of concrete surfaces of ceiling, beam bottom, roof projection etc, finished even and smooth without using extra cement including necessary scaffolding for any height etc complete all as specified and directed.
Material and Labour for rendering 15mm thick (in two coats of 10mm under coat and 5mm plaster) on fair faces of brick work/stone or concrete surfaces in cement mortar 1:4 finished even and fair without using extra cement for both coats mixed with integral water proofing compound at the rate of 3% by weight of cement all as per manufactures instructions incl necessary scaffolding etc for any height complete all as specified and directed. Note : Water proofing compound will be measured and paid separately
Supply only Integral water proofing compound of make IMPERMO/ ACCOPROOF complete all as specified and directed.
M & L for applying two coat of Plastic emulsion paint over a coat of primer as preparatoy to paiting including prepration of newly platered surface of wall with applying 3mm thick wall care putty complete all as specified and directed.
M & L for applying two coat of Plastic emulsion paint over a coat of primer as preparatoy to paiting including prepration of old decorated surfaces of wall including complete removal of existing treatment including washing, rubbing down etc. of wall with applying 3mm thick wall care putty complete all as specified and directed.
M & L for applying two coat of Plastic emulsion paint over a coat of primer as preparatoy to paiting including prepration of newly platered surface of ceiling with applying 3mm thick wall care putty complete all as specified and directed.
M & L for applying two coat of Plastic emulsion paint over a coat of primer as preparatoy to paiting including prepration of old decorated surfaces of ceiling including by complete removal of existing treatment including washing, rubbing down etc of ceiling with applying 3mm thick wall care putty complete all as specified and directed.
M & L for preparation of newly plaster surface and applying two coat of weather proof acrylic emulsion exterior paint over a coat of weather proof acrylic emulsion exterior primer (Asian or equivalent) and applying 3mm thick weatherproof putty on walls including scaffolding with required safety measuers etc complete all as specified and directed.
All as per item No 15 but Camouflage
Complete Removal of existing treatment on walls including removing dirt, nails, making good holes cracks etc brooming down with steel wire brushing scrapping down smoke soots etc and Two coats of weather proof exterior Acrylic emulsion paint (Camouflage) (APEX or equivalent) of any tint over one coat of Exterior Acrylic primer (Asian or equivalent) and applying 3mm thick weatherproof putty on walls including scaffolding with required safety measuers etc complete all as specified and directed.
M & L for 100mm cement concrete type B-1, 1:2:4 using 20mm graded aggregate as in flooring and finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. Note: 1. For demolition, power for drilling machine will be supplied by mobile generator on own arrangement by contractor 2. Wastage of time for TFF issue from ISO/Fire station (as usage of generator involved) may be considered while quoting
Forming 12mm thick Expansion joints in 100mm thick concrete slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade A complete all as specified and as directed.
Forming contraction (Dummy) joint 30mm deep x 10 mm wide with 'A' grade sealing complete all as specified and as directed.
M and L preparation of newly plaster surface on external wall surfaces and applying two coats of cement base paint over over a coat of primer complete all as specified and as directed.
M & L for cutting out cracks to V-section in existing floor/roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen/epoxy/silicon gel and clean dry sand 1:1 (by weight) complete all as specified and directed.
S & F Mild steel flat iron as in hold fast 25x6 mm confirming to Fe 290 Gde E-165 complete all as specified and directed.
M & L for preparation and treating small articles, area tarred n.exc 0.10 Sqm each such as hold fasts end of posts, back of chowkhats complete all as specified and directed.
Cutting holes in brick/stone/concrete walls built in cement mortar for inserting hold fasts depth of embedded portion of hold fast n.exc half brick and making good the dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed.
Cutting holes into or through brick/ stone walls built in cement mortar or cement lime mortar and making good in CM 1:3 or cement concrete 1:2:4 type B1 as required of superficial area exceeding 150 Sqcm but n.exc 400 Sqcm complete all as specified and directed.
Excavating in trenches, n. exc. 1.5m wide and n. exc 1.5m in depth for foundation etc getting out hard/desne soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm. Hard/dense soil complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above starting point getting out soil complete all as specified and directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
Material and Labour cement concrete Type B2, 1:2:4 (using 40mm graded aggregate) in foundation filling and mass concrete in any position complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed.
S & F MS door/ ventilator framed work as in door or gate of angle or other section Fe-290W (Gde E-165) quality 'A' with gusset plats,MS plate, rails, braces,guard bars, flats etc complete drilled for fixing for steel sheeting or other covering in door etc including nut and bolts required prepared for hanging with steel doors fitting and hanging on pintels including pintle hinges, stops, hand made sliding bolts, bolts for fixing ventilators any frame on walls etc also complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) n. exc. 1.5 Sqm each complete all as specified and as directed.
All as per Item No. 34.00 here in before but exceeding 1.5 Sqm and not exceeding 4.00 Sqm each.
Taking down shutters of any description n exc 1.00 Sqm each and refix in same opening complete all as specified and directed.
Taking down shutters of any description but exc 1.00 Sqm and not exc 2.00 Sqm each and refix in same opening complete all as specified and directed.
Taking down shutters of any description but exc 2.00 Sqm each and refix in same opening complete all as specified and directed.
S & F in repairs 1.60 mm thick MS sheet plain black steel door and similar work cut to size, holes, punched including round headed screws with plain 40mm lap joints with riveted or welded seams including bending or turning up mitred angles etc as requried all as directed.
M & L for applying two coat of synthetic enamel paint on new steel surfaces over 10 cm width or girth including preparation surfaces of any description not otherwise described including red oxide as a prime coat complete all as specified and as directed.
M & L for applying one coat of synthetic enamel paint on old steel surfaces over 10 cm width or girth including preparation surfaces of any description not otherwise described including red oxide as a prime coat complete all as specified and as directed.
Demolition of brick/stone masonry walls built in cement mortar including all quoins, arches, pillars, retaining walls etc. complete all as specified and as directed .
M & L for brick work fly ash brick with old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Dismantling of asbestos cement sheets any corrugation including ridge as in roof covering complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Cleaning of open drain of any typeand of anygirth of by removing dirt,mudcutting vegetable growth by excavationon orby any means and removing to a distance 50 Meter complete all as specified and as directed.
S&F for Expanded metal, n exc 4Kg per Sqm cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and directed.
M & L for oblitering old writing of any description n. exc 0.10sqm with synthetic enamel paint to match existing work complete all as specified and directed.
M & L for writing letters of figures (Black Roman, Italic or Indian) n. exc 30cm height complete all as specified and directed.
Taking down existing water proofing treatment complete of any description from RCC roof slab and porches by scraping by means of MS scrapper patty or by any suitable tools until the concrete surface of the slab visible and removal of rubbish off the premises as directed to a distance not exc 100 mtr all as specified and as directed. Note : Rate for removal and re-fixing existing lightning conductors/ strips / assembly is deemed to be included under quoted rate of this item.
Taking down Pressed cement concrete tiles incl 15mm thick bedding mortar in CM 1:4 complete all as specified and as directed.
M&L for 25mm thick (average thickness) PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregates) laid on roof slab finished even and fair complete all as specified and as directed.
M&L for Brushing neat cement slurry with 3.0 kg of cement per sq. Metre complete all as specified and as directed.
M&L rendering 10mm thick on concrete surface on roof top in cement mortar 1:4 with using water proofing compund & finishing the surface even & smooth without using extra cement complete all as specified and as directed. ( Note- Water proofing compound shall be measured and paid seperatly )
M&L for Atactic propylene modified prefabricated membrane (3 mm thick with non-woven polyester mat) minimum weighing 3.5 kg/sqm with side laps of minimum 100 mm and end laps of minimum 150 mm laid and including vertical surfaces upto required height and tucking into grooves and sealing complete with thermofusion, torch application over compatible bitumen primer at 0.40 ltr/sqm including cleaning surfaces all as instructed as per manufacturer and directed by Engineer-in-charge over roof slab and porches complete all as specified and as directed.
S & F Hydraulically pressed cement concrete tiles 250x250x22-25mm as decided, machine pressed laid over 15mm thick bedding mortar in CM 1:4 having joint of tiles 2-3 mm wide set jointed and pointed with chemical like Tile-grout or equivalent as approved by GE complete as specified and directed.
All as per item No 56.00 but fixing only
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for rolled sections of Fe-410 W (Gde-E-250) quality B as in main and cross beams, hips, and jack rafters; purlins where connected to common rafter and running rails and guides for sliding doors; fixed with angle cleats or other connecting pates complete all as specified and directed.
Dismantling wooden scantling of any size and at any position and at any height un-framed work, in cladding, purlins, rafters etc including cutting, drilling, bolting etc complete all as specified and as directed.
SHUBHAM SALES
M/s Prakash Agencies
SHREE SIDDHIVINAYAK TRADERS
M/s VILAS RATAN MENDHE
M/s MM TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
SHREE CONSTRUCTIONS
M/S Maa Durga Constructions,Pulgaon
M/S DEV ENTERPRISES
Bidder Name
SHREE CONSTRUCTIONS
SHREE SIDDHIVINAYAK TRADERS
M/s VILAS RATAN MENDHE
M/S DEV ENTERPRISES
M/s Dara Constructions, Pulgaon
M/S Maa Durga Constructions,Pulgaon
M/s Prakash Agencies
M/s MM TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
SHUBHAM SALES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .