Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC C O OPPOSITE BDO OFFICE MANDA AKHNOOR DISTT JAMMU PIN 181201 | JAMMU | JAMMU AND KASHMIR | 181201 | L1 | Accepted-AOC Accepted being lowest. Allotted new Number GE FRD-27/2021-22 | |
| 2 | L2₹30.0 L+₹34,927.55 (1.18%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹32.3 L+₹2.7 L (9.15%)Rejected-Finance | L3 | Rejected-Finance Rejected |
Tender Value
₹25.4 L
EMD Value
₹50,900
Closing Date
9 Jun 2021, 6:00 pmClosed
GE Faridkot
Garrison Engineer, Faridkot-151203 Punjab 01639-264982
Balance work for Special repairs to OTM Accn Bldg No. P-21, Provn of sewage line between T-30 and T-53 near MES complex, Spl repair to sewage line and Provn of toilet block near Bldg No. T-14 under AGE B/R (M) at Faridkot Mil Stn
2021_MES_425073_3
GE FRD-78/2020-21
Open Tender
Civil Works
Item Rate
180 days
Faridkot Mil Stn
Class D Category a i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹50,900
Yes
18 Jun 2021
19 May 2021
11 Jun 2021
19 May 2021
9 Jun 2021
26 May 2021
Amount
Demolition of brick work or stone boulder masonary, built in cement mortar including all quoins, arches, pillars etc in any position and stacking them and disposing off the unserviceable material and rubbish but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed by Engineer in Charge.
Demolition of cement concrete (unreinforced) as in manhole foundation and bedding of sewer lines etc below ground level and disposal off rubbish to a distance exceeding 1 Km and 1.5 Km and not exceeding 1.5 Km complete all as specified and directed by Engineer in Charge.
Demolition and breaking up drain pipe (Salt glazed stoneware, AC or Reinforced concrete) 150 mm dia set in cement mortar including demolition of haunching concrete complete all as specified & directed by Engineer in Charge.
Demolition and breaking up drain pipe (AC or Reinforced concrete) 200 mm dia set in cement mortar including demolition of haunching concrete complete all as specified & directed by Engineer in Charge.
Demolition and breaking up drain pipe (AC or Reinforced concrete) 300 mm dia set in cement mortar including demolition of haunching concrete complete all as specified & directed by Engineer in Charge.
Excavation in trenches not exc. 1.5 meter wide and not exc. 1.5 meter in depth in foul condition for foundation etc and getting out in soft/loose soil complete all as specified and directed by Engineer in Charge. Note : Necessary dewatering of water shall be included in the unit rate of item
All as per item No 06 here-in-before but exc.1.5 m and not exc. 3 m in depth complete all as specified and directed by Engineer in Charge.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in soft /loose soil complete all as specified and directed by Engineer in Charge.
Removing excavated material or surplus soil not exc 50 meter and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer in Charge.
M & L for salt glazed stoneware drain pipe 150 mm dia grade 'A' laid in trenches making joints and testing complete all as specified and directed by Engineer in Charge.
S&F Reinforced concrete pipes class NP-2 laid, jointed and tested complete with collar of size 150mm (internal dia) all as specified and directed by Engineer in Charge.
M & L for reinforced concrete pipes class NP-2 laid and jointed complete with collar of size 200mm (internal dia) all as specified and directed by Engineer in Charge.
S&F Reinforced concrete pipes class NP-2 laid, jointed and tested complete with collar of size 300mm (internal dia) complete all as specified and directed by Engineer in Charge.
M&L for Concrete bed to drain pipes using PCC 1:3:6 type C-2 40mm graded stone aggregate including packing under haunching against the sides of pipe after laid & tested for 150mm bore of pipes complete all as specified and direced by Engineer in Charge.
M&L for Concrete bed to drain pipes using PCC 1:3:6 type C-2 40mm graded stone aggregate including packing under haunching against the sides of pipe after laid & tested for 200mm bore of pipes complete all as specified and direced by Engineer in Charge.
M&L for Concrete bed to drain pipes using PCC 1:3:6 type C-2 using 40mm graded stone aggregate including forming cradles for 300mm dia of pipes complete all as specified and directed by Engineer in Charge.
M&L extra for forming forming fair fineshed drain or channel exceeding 15cm in width or girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed by Engineer in Charge.
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling /mass concrete finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for brick work with fly ash brick, old size, straight or covered or plan exc 6m mean radius built in CM 1:4 complete all as specified and directed by Engineer in Charge.
All as per item No 19 here-in-before but except bricks complete all as specified and directed by Engineer in Charge
M&L PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in benching for manholes, bands, coping, bed plates including slightly rounded or chamfered angles including necessary formwork complete all as specified and directed by Engineer in Charge
M&L rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement including Water proofing compound (for both internal & external finish) complete all as specified and directed by Engineer in Charge. Note : WPC shall be measured and paid separately.
Supply only Liquid water proofing compound complete all as specified and directed by Engineer in Charge.
Dismantling CI/PVC 75mm/100mm /110mm bore pipes including fittings jointed in cement mortar and taking out from below or above GL or laid in floos or fixed to walls complete all as specified & directed by Engineer-in- charge.
S&F 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvant and fixed to walls Cutting holes in brick wall built in cement mortar for inserting holdfasts, depth of embedded portion not exceeding half brick (measured from the face of jamb into the wall) and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified and directed by Engineer-in- charge.
S&F 75 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvant and fixed to walls Cutting holes in brick wall built in cement mortar for inserting holdfasts, depth of embedded portion not exceeding half brick (measured from the face of jamb into the wall) and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified and directed by Engineer-in- charge.
S&F 110mm bore PVC(SWR) bends (any radius), diminishing pieces or tapers ( larger bore measured) laid in trenches or fixed in floors/walls complete all as specified and directed by Engineer-in-charge .
S&F 75mm bore PVC (SWR) vent cowl fixed complete all as specified and directed by Engineer-in-charge .
S&F 110mm bore PVC(SWR) branch pieces single equal ordinary spigot laid in trenches or fixed in floors/walls complete all as specified and directed by Engineer-in- charge.
S&F 110mm bore PVC(SWR) reducer complete all as specified and directed by Engineer-in- charge.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement with outlet pipes and PCC 1:2:4 type B1 filling around trap and 25 mm thick cover slab complete all as specified and directed by Engineer-in- Charge.
S&F 100mm bore cast iron sand cast soil, waste and spun pipe in any length with or without ears laid in trenches or in floors/walls with cement joints and provision of required number flat iron clamps of required size complete all as specified and directed by Engineer-in-charge.
S&F 100mm bore cast iron bends (any radius), diminishing pieces or tapers ( larger bore measured) with access door,with(ordinary or inverted) spigot with parallel branches with single (Y) laid in trenches or fixed to walls complete all as specified and directed by Engineer-in-charge .
S&F 75mm bore cast iron bends (any radius), diminishing pieces or tapers ( larger bore measured) with access door,with(ordinary or inverted) spigot with parallel branches with single (Y) laid in trenches or fixed to walls complete all as specified and directed by Engineer-in-charge .
De-sludging / cleaning by removing semi solid sludge from the sump well/ septic tank of any capacity of any depth of sewage pump installation/septic tank manually or machanically in foul condition including all necessary T & P required for removal of sludge and solid contents to any place outside defence land at a distance exceeding 1.5Km but not exceeding 5 Km all as specified and directed by Engineer in Charge.
S & F Factory made SFRC (Steel fiber Reinforcement Concrete ) Manhole cover (without frame) medium duty 900mmx450mm x70mm thickness including 2mm thick flat iron frame all round complete all as specified and directed by Engineer in Charge.
S & F Factory made SFRC (Steel fiber Reinforcement Concrete ) Manhole cover (without frame) medium duty 600mmx600mm x70mm thickness including 2mm thick flat iron frame all round complete all as specified and directed by Engineer in Charge.
M&L for Cutting into existing manholes for connecting new drains,making good to pipe and rendering,cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and directed by Engineer in Charge.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep in soft/ loose soil and getting out including cutting of grass roots, bushes if any and filling of lower portion with soil obtained from cutting or dressing complete all as specified and directed by Engineer-in-Charge.
M&L for providing Reinforced cement concrete M-25 (nominal mix), using 20mm graded stone aggregate as in rafts, footings, foundations beams; plinth beams, bases for column etc; basement slabls, under-reamed piles complete all as specified and directed by Engineer-in-Charge.
M&L for providing Reinforced cement concrete M-25 (nominal mix), using 20mm graded stone aggregate as in column, pillars, piers, posts and sturtscomplete all as specified and directed by Engineer-in-Charg
Material and labour for reinforced cement concrete M-25 (nominal mix) using 20mm graded stone aggregate as in beams, lintels upto 1.5 metre clear span, cills, steps, seismic and other similar bands, beams, parapets upto 60cm height and the like including weathering, slightly rounded or chamfered angles and throatings etc. complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for reinforced cement concrete M-25 (nominal mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
M&L Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams,and similar work; vertical or to batter for rought finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
M&L Form work to sides of pillars,posts, struts, piers, columns and stanchions finished fair complete all as specified and directed by Engineer-in-Charge.
M&L for use and waste of form work to soffits of suspended slabs such as floor or roof slab, landing and similar work not exceeding 200mm thick (Horizontal or slopping) for rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for use and waste of form work to side and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc, also splays between floors and beams,etc for rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
M & L mild steel TMT bars 10 mm dia and over, cut to lenth bent to shape required, including cranking bending spirally for hooping for columns hooking end and binding with and including mild steel wire(annealed) not less than 0.9mm dia complete all as specified and directed by Engineer in Charge.
M & L mild steel bars 6 to 8 mm dia and over, cut to lenth bent to shape required, including cranking bending spirally for hooping for columns hooking end and binding with and including mild steel wire(annealed) not less than 0.9mm dia or sequring with clips quality confarming to TMT bars complete all as specified and directed by Engineer in Charge.
M&L for Brick work with fly ash bricks sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per item No 50 here-in-before but except bricks complete all as specified and directed by Engineer in Charge
M&L for Brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 15 mm thick cement plaster in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished fair and even without using extra cement complete including preparation of new surfaces plastered or unplastered and applying two coats of colour wash on wall over one coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 5 mm thick cement plaster on ceiling surfaces in cement mortar 1:3 finished fair and even without using extra cement complete including preparation of new surfaces plastered or unplastered and applying two coats of white wash on ceiling over one coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L rendering 10mm thick in cement plaster on roof in cement mortar 1:4 with WPC finished even and smooth without using extra cement and preparation of newly plastered or unplastered surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed by Engineer in Charge. (WPC shall be measured and paid separately)
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 furrowing the under with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement Plaster 1:1/2:2 (1 Cement : 1/2 Coarse sand : 2 Stone chipping 10mm nominal size) in panels with grooves all round as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed by Engineer-in-Charge.
M&L for forming grooves of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using removal of wooden battens, nailed to the under layer repair to the edges of panels and finishing the grooves complete all as specified and directed by Engineer-in-Charge.
Supply only inttegral water proofing compound complete all as specified and directed by Engineer in Charge.
S&F solid PVC door frame WOOD GRAIN PRINTED of size 50x47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube in opening as per schedule complete all as specified & directed by Engineer-in-Charge.
S&F Factory made solid PVC door shutter 30mm thick (style) WOOD GRAIN PRINTED consisting of frame made out of MS tube for top and bottom rail MS frame shall be covered with heat moulded plain / coloured PVC "C"channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the style & rail with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and directed by Engineer-in-Charge.
Supply only Mild Steel medium weight colled rolled (ISI marked) butt hinges 100 mm long complete all as specified & directed by Engineer-in-Charge.
S&F 150mm long dia aluminium anodized tower bolts extruded section, fixed with steel screws complete as specified & directed by Engineer-in-charg
S&F 125 mm long dia "D" aluminium anodized handles cast type, fixed with steel screws complete as specified & directed by Engineer-in-charg
S&F box type mild steel ventilator with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and directed by Engineer-in-Charge.
S&F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture not more than 1.18 mm and fixed with rails/wooden beading/steel staple complete all as specified and directed by Engineer-in-Charge.
S&F for 3mm thick sheet glass obscured or frosted on one side as in glazing with oil putty or with wooden beads(supplied along with shutters) in square n.exc 0.5 sqm in each pane complete all as specified and directed by Engineer in Charge.
M&L for preparation of new primed steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coat of synthetic enamel paint complete all as specified and directed by Engineer in Charge.
M & L for 25mm thick cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate finished rough to receive glazed tiles complete all as specified and directed by Engineer-in-Charge.
S & F non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.06sqm but n.exc 0.11 sqm, as in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer in Charge.
S&F coloured Glazed ceramic tiles (light colour as approved) in vertical surface such as skirting/dados 450x 350x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement with pigment ot match over and including rendering of 10mm thick rendering in cement mortar 1:3 on brick or concrete surface complete all as specified and directed by Engineer in Charge.
S&F in repair wash hand basin flat back 550X400mm vitreous chine (white) with cantilever brackets embedded in concrete block including the following and fixed in repairs complete all as specified and directed (a)Brass chromium plated waste coupling 32 mm bore size (b) Waste pipe PVC 32 mm bore (c) Angle iron/cost iron brackets (d) CP Fancy type pillar cock 15mm.
S&F 15mm dia fancy type chromium plated angle valve with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe or for unions fixed complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm dia fancy type chromium plated angle valve with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe or for unions fixed complete all as specified & directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tank (cylindrical vertical triple layered white colour with closed top) hoisted and fixed in position of capacity 500 litres including PTMT ball valve high pressure with polythene float and fly nut suitable for 20 mm bore GI pipe, 25mm bore GI washout pipe 15 cm long fitted with check nut, 20mm bore over flow pipe 1.50 metre long fitted with brass anti-mosquito nest coupling at the end of over flow pipe & 15mm bore GI air vent pipe 1.30 metre long fitted with tee at the end of air vent pipe (all GI pipes shall be medium grade) complete all as specified and directed by Engineer-in-Charge.
S&F in repair rotational moulded polyethylene water storage tank (cylindrical vertical triple layered white colour with closed top) hoisted and fixed in position of capacity 1000 litres including PTMT ball valve high pressure with polythene float and fly nut suitable for 20 mm bore GI pipe, 25mm bore GI washout pipe 15 cm long fitted with check nut, 20mm bore over flow pipe 1.50 metre long fitted with brass anti-mosquito nest coupling at the end of over flow pipe & 15mm bore GI air vent pipe 1.30 metre long fitted with tee at the end of air vent pipe (all GI pipes shall be medium grade) complete all as specified and directed by Engineer-in-Charge.
S & F Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed 20 mm dia of pipe complete all as specified and directed by Engineer in Charge.
Supply and fixing vitreous China squatting pan Orissa pattern, size 580 x 440mm white / coloured with integral foot rest including flush pipe and connection to 100 mm dia "P" trap and to flushing pipe, anti syphonage pipe with WC including necessary lime concrete including 10 ltr PVC valveless syphonic action type, flushing cistern low level, white with inlet ball valve, float and handle including brackets etc complete.all as specified and directed.
Taking up or down existing galvanised steel water tubing (GI pipe) 15 mm bore including fitting/connection from wall/ceiling/floor etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20 mm bore including fitting/connection from wall/ceiling/floor etc. complete all as specified and as directed by Engineer-in-charge.
S&F mild steel water tubes of size 15mm bore (medium grade) galvanised with all fittings and fixed concealed in walls and ceiling or laid in floors complete all as specified & directed by Engineer-in-charge.
All as per item No 81 here-in-before but except mild steel tubes complete all as specified and directed by Engineer in Charge
S&F mild steel water tubes of size 20mm bore (medium grade) galvanised with all fittings and fixed concealed in walls and ceiling or laid in floors complete all as specified & directed by Engineer-in-charge.
All as per item No 83 here-in-before but except mild steel tubes complete all as specified and directed by Engineer in Charge
S&F 15mm bore bib tap, cast copper alloy, chromium plated with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F in repair 15mm bore bib tap, cast copper alloy, chromium plated with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
Supply & fixing vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling and 32mm dia waste pipe and pointing around urinal back in cement mortar, including Urinal spreader of PTMT suitable for fixing with 15 mm dia pipe and including Push tap high pressure of PTMT screwed for iron pipe 15mm bore (Minimum weight 47gms) complete all as specified & directed by Engineer-in-charge.
Taking down wooden/steel chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.50 Sqm each including cutting holes of appropriate size in brick walls/ concrete surfaces for insertion of PCC block of hold fasts complete all as specified & directed by Engineer-in- charge.
Taking down shutters of any description wooden/aluminium exc 1 sqm and n. exc 2 sqm each and refixing in the same opening after easing, adjusting and replacement of minor nails etc complete all as specified and directed by Engineer in Charge.
M&L for pressed steel frames(1.25mm thick) for door of size 105mm x 60mm with one or more rebates including necessary fixing arrangement such as lugs, hinges, lock strike plate etc complete all as specified and directed by Engineer-in-Charge. Note : Hinges will be measured & paid separately under relevant item.
M&L for pressed steel frames(1.25mm thick sheet) for door with one or more rebates including necessary fixing arrangement such as lugs, hinges, lock strike plate etc size of frame 125 mm x 60 mm incl one shop coated of red oxide primer complete all as specified and directed by Engineer-in-Charge. Note : Hinges will be measured & paid separately under relevant item.
M&L for framed work such as grills,gratings, cooler stand, ladders etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; shouldered with steel windows / ventilators frame; railings; framework of water tanks and similar work conforming to (Fe.290.Gde-E-165) complete all as specified and directed by Engineer-in-Charge.
S&F 35mm thick, factory made plain framed panelled (any number of panels) shutters of 2nd class hard wood with lock rail and panel inserts of 9mm thick BWP commercial ply or 12mm thick veneered particle board flat pressed three layered conforming to IS-3097 exterior grade-I type- I duly ISI marked general purpose commercial veneered on both side bonded with (BWR) type phenol formaldeyde synthetic resin-adhesive, the size of rails and styles as per IS-1003 Part-I, Kiln seasoned and chemically pressure treated complete all as specified & directed by Engineer-in-Charge. Note :- The species of timber shall be Hollock/Bonsum
S&F 35mm thick, glazed and skeleton shutter of 2nd class hard wood open rebated and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8.24 (a) and fitted to chowkhats complete all as specified and directed by Engineer-in-Charge. Note :- The species of timber shall be Hollock/Bonsom.
S&F factory made steel window with side hung shutters including box type hinges with steel handle and 2 Nos 150mm long mild steel tower bolt,fixing lugs etc complete with glazing bars dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
S&F factory made steel window with side hung shutters including box type hinges with steel handle and 2 Nos 150mm long mild steel tower bolt,fixing lugs etc complete without glazing bars dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty or with wooden beads(supplied along with shutters) in square n.exc 0.5 sqm in each pane complete all as specified and directed by Engineer in Charge.
S&F figured glass 3.0mm thick pin head type at wooden/aluminium/steel window/door glazed and glazing with oil putty in squares not exceeding 0.50 sqm in each pane complete all as specified & directed by Engineer-in-charge
S&F 150 mm long dia aluminium anodized cast type door handles , fixed with steel screws complete as specified & directed by Engineer-in-charg
S&F 150 mm long dia aluminium anodized tower bolts , fixed with steel screws complete as specified & directed by Engineer-in-charg
S&F 125mm long dia aluminium anodized tower bolts , fixed with steel screws complete as specified & directed by Engineer-in-charg
S&F 250 mm long aluminum alloy, anodised, sliding door bolt with hasp, staple (bolt type) not less than 12 mm dia and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified & directed by Engineer-in- charge.
S&F 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed by Engineer-in-charge.
S&F 140 mm long cover plate floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed by Engineer-in-Charge.
Supply & fix 75 mm long butt hinges mild steel medium weight cold rolled complete all as specified & directed by Engineer-in-charge .
M&L for preparation of new wooden or wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink wood primer complete all as specified and directed by Engineer-in-Charge.
S&F in repair Mild steel powder coated colour decorative type drapery curtain rod 20mm dia approved pattern & design, including brackets and pair of decorated end knobs, stop roller and fixed with powder coated mild steel flat iron brackets in the steel screws & PVC rawl plugs / grips etc complete all as specified & directed by Engineer-in- charge.
M & L for PCC 1:3:6 type C-0 using 12.5mm graded stone agg a in back filling of pressed steel frames, bed blocks, coping, fixing of hold fast blocks etc including necessary form work complete all as specified and directed by Engineer-in-Charge.
Demolition of un-reinforced cement concrete (unreinforced) of any description in ground floor & paving (not exceeding 15cm below/above ground level) and removing from site complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and directed.
M&L for Roughening surfaces of old concrete roof/floor for removing old bitumen coat/any other type of treatment etc.by picking, sweeping clean and washing down with water to remove dirt/dust, etc. complete all as specified and directed by Engineer-in-Charge.
S & F non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.11sqm but n.exc 0.18 sqm, as in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer in Charge.
All as per srl item No. 112 here-in-before but as in vertical surfaces such as skirting, dados & risers to steps etc complete all as specified and directed by Engineer in Charge.
S&F coloured Glazed ceramic tiles (light colour as approved) in vertical surface such as skirting/dados 450x 350x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement with pigment ot match over and including rendering of 15mm thick rendering in cement mortar 1:4 on brick or concrete surface complete all as specified and directed by Engineer in Charge.
M&L for 20-25 mm thick machine cut Kota stone slab of size 55cm x 55cm (minimum) as in floors/treads laid over cement mortar screed base, jointed with grey cement slurry mixed with pigment to match the shade of slab over and including 15mm thick screed bed in CM 1:4 including rubbing and mirror polishing complete all as specified and directed by Engineer-in-Charge.
M&L for 18mm to 20mm thick machine cut kota stone slab of length not less than 50cm as in vertical surfaces such as risers of steps, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 10mm thick rendering in CM 1:3 including rubbing, mirror polishing also moulding edges complete all as specified and directed by Engineer-in-Charge.
M&L Granite (of any type) 20mm thick machine cut, on cooking platform and like in cement mortar 1:4 including pointed with white cement 1:2 using marble dust with admixure of pigment to match the shade of granite stone including cutting & polishing complete all as specified and directed by Engineer in Charge.
M & L for 50mm thick plain cement concrete (1:3:6) type C-2 using 20mm graded stone aggregate as in plinth protection etc finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for taking down of cement plaster and rendering 15 mm thick in cement mortar 1:6 on fair faces of brick or concrete surface finished even and fair without using extra cement complete all as specified and directed by Engineer in Charge.
M&L for taking down of cement plaster and rendering 15 mm thick in cement mortar 1:4 on fair faces of brick or concrete surface finished even and fair without using extra cement complete all as specified and directed by Engineer in Charge.
M&L for taking down of cement plaster and rendering 10 mm thick cement plaster on ceiling surfaces in cement mortar (1:3) on fair faces of brick or concrete surfaces without using extra cement complete all as specified & directed by Engineer-in-Charge.
M & L preparation of newly plastered or unplastered surfaces of wall by mechanical method i.e. Electric grinder and applying two coats of distemper oil emulsion white/ tinted with a wall care putty finished surface with a wall care putty finished surface over one coat of primer by mechanical roller / hand roller complete all as specified and directed by Engineer in Charge.
Providing & applying rising damp-proof coating system with single component ready to use damp-proof coating Roff Hydamp: 1. Surface Preparation : Thoroughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, brid droppings, etc. All large voids or hollow portions must be removed and re-plastered. Non-moving cracks having width upto 5mm must be filled with Polymer based crack filler. 2. APPLICATION : Apply the first coat of Roff Hydamp with a paintbrush directly on the prepared surfaces. Allow to dry for a minimum 2-3 hrs. Apply one part of Roff Hydamp and 2 parts of OPC cement and make the putty, apply putty on the entire surface area. Allow it to dry for at least 3-4 hours. Apply the final coat of Roff Hydamp on the entire surface. Make : Dr Fixit Note : Complete application will be carried out by authorised distributor & Applicator : Dr Fixit Project division
M & L for complete removal of existing treatment of old decorated surfaces of ceiling by brooming down and scrapping down smoke soot, moulds, moss and efflorescence salt and treating oil and greasy spots and applying two coats of distemper oil emulsion white/ tinted with a wall care putty finished surface over one coat of primer complete all as specified and directed by Engineer in Charge.
M&L for preparation of new plastered surfaces of wall and applying two coats of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered or pointed surfaces of walls,soffits/fecia etc and applying two coats of cement based paint complete all as specified and directed by Engineer-in-Charge.
M & L for complete removal of existing treatment such as white wash, colour wash, synthetic enamel paint etc of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescence salt and treating oil and greasy spots and applying two coats of cement base paint over one coat of primer complete all as specified and directed by Engineer in Charge. Note : Curing of surface will be carried out as per Para 15.15.3 of SSR Part-I.
M & L preparation of newly plastered or unplastered surfaces of ceiling and applying two coats of distemper oil emulsion white/ tinted with a wall care putty finished surface with a wall care putty finished surface over one coat of primer complete all as specified and directed by Engineer in Charge.
M&L for preparation of old decorated surfaces of ceiling and applying two coats of white wash complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins,arches & pillars etc of any description and in any position complete all as specified and directed by Engineer-in-Charge.
S&F in repair CP brass wall mixer, for mixing hot & cold water screwed for 15mm bore of iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair vitreous china wash down water closet pan (pedestel pattern/EWC/longpan) white in colour including connection pipe to union of flushing cistern, inlet and overflow pipes,connecting only to flushing cistern anti-syphonage pipe with PVC flush pipe of 32mm dia and plastic seat cover with mild steel chromoum plated hinging and 'P' or 'S' trap device complete all as specified and directed by Engineer-in-Charge.
S&F PVC Connections 15 mm size with PTMT nuts of length 450 mm long complete all as specified & directed by Engineer-in-charge.
S&F shelf of PTMT fixed with and including chromium plated brass screw and plastic cleat (Minimum weight 300 gms) complete all as specified and directed by Engineer in Charge.
S&F PTMT cabinet with mirror of size 450x300mm complete all as specified & directed by Engineer-in-Charge. Make : Prayag Cat No. 555 /polytuf / Pearl/ Shakti as approved by GE
S&F in repair brass chromium plated shower rose 125mm size with or without swivel joints including fixing to steel pipe of 15mm bore complete all as specified and directed by Engineer in Charge.
S&F Towel rail, 450mm long of PTMT fixed with and including chromium plated brass screws and wooden and plastic cleats ( minimum weight 170gms ) complete all as specified & directed by Engineer-in-Charge.
S&F cast iron or mild steel peg set 175mm to 250mm with hooks fixed to wall complete all as specified and directed by Engineer-in-Charge.
M&L in repairs CI Floor trap long neck 75 mm dia, with stainless steel grating including jointing to waste pipe fixed in cement concrete type B1, 1:2:4 complete all as specified and directed by Engineer in Charge.
S&F in repair PVC (SWR) 100/110mm bore 'P' trap complete all as specified and directed by Engineer in Charge.
S&F 100mm bore cast iron branch pieces single equal ordinary spigot laid in trenches or fixed in floors/walls complete all as specified and directed by Engineer-in- charge.
S&F 75mm bore cast iron branch pieces single equal ordinary spigot laid in trenches or fixed in floors/walls complete all as specified and directed by Engineer-in- charge.
S&F cast iron vent cowl 75mm dia suitable for 75 mm bore pipe complete all as specified and directed by Engineer in Charge.
M&L for Water proofing treatment to RCC sunken slab (not exceeding 45cm depth of sunken) as specified below and as directed by Engineer-in-Charge:-(a) Applying 15 mm thick plaster in CM 1:3 with WPC on raised verticle surface. (b) Cleaning the surface with wire brush/coir brush, removing lose material like dust particles, dirt etc.(c) Creating fillet covering of 50mmx50 mm with polymer modified mortar on the junction of slab and walls. (d) Apply first coat of two component modified polymer coating on the horizontal and verticle surface. (e) Provision of glass fiber mesh of 2 x 2 mm immediately on above coating.(f) Apply second coat of two component modified polymer coating after 72 hrs. (g) Laying Cement concrete 1:4:8 over the coating as per requirment. (h) Joining the saintary pipes with the water proofing tape having bridging ability of more than 1.5 mm. (j) Filling the gap between the wall opening and saintary pipe with non shrink cementatious grout complete as specified Manufacturer.(k) The treatment to be carried out by authorised applicator of Water Proofing Manufacture. Make:- Dr. Fixit/Fosroc/BASF/STP Limited. Note: (i) The treatment shall be carried out by approved authorised applicator as per the manufacturers instructions and as directed by the Engineer in charge. (ii) The Plan area of floor shall be considered for payment and provn of PCC in filling. (iii) WPC will be measured separately under relevant item of BOQ.
Demolition of cement concrete (un-reinforced) in roof any thickness including plastering and leaping (whether full thickness removed or only part thereof) complete all as specified and directed by Engineer-in-Charge.
M&L rendering 10mm thick in cement plaster on roof in cement mortar 1:3 with WPC finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge. (WPC shall be measured and paid separately)
M&L for applying evenly a tack coat of industrial bitumen 85/25 @ 1.20 Kg/Sqm including preparation of roof surfaces complete all as specified and directed.
M&L Polythene film 300 micron thick laid on roof over a coat of bitumen primer, @ 0.30 to 0.50 Kg per sqm conforming to IS specification with lap joints 100mm complete all as specified and directed.
M&L lime concrete 80mm thick 1:2:5 (Lime : Surkhi : Brick balast 40mm) terracing on roof (excluding bitumen tack coat) complete all as specified and directed by Enigneer-in-Charge.
M&L for 40mm thick brick tiles laid on mud mortar & joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska complete all as specified and directed by Engineer-in-Charge.
All as per item No 150 here-in-before but except brick tiles complete all as specified and directed by Engineer in Charge
M&L for broken brick hard core of gauge not exceeding 63mm deposited, spread and leveled in layers not exc 15cm thick, watered and rolled/rammed to a true surfaces complete all as specified and directed by Engineer-in-Charge
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M&L for Coloured Machine pressed precast concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 60mm thickness M-35 Grade, with grey cement and no pigment complete all as specified and directed by Engineer-in-Charge. Note : Paver block shall be approved by GE in writing before incorporation in work.
M & L for (factory casted, rubber moulded) pre-cast cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in kerb stone of any size or any thickness with plain fair faces, smooth finish, including chamfering, weathering, throating etc set in cement mortar 1:4, including necessary form work and excavation & earth work for embedding kerb stone at a depth as directed & temping around kerb stone and removal of surplus soil to a distance n.exc 50 metre & depositing where directed complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new concrete surfaces of any description, over 10 cm width or girth and applying two coats of plastic emulsion paint over a coat of cement primer complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including fittings such as switches, ceiling roses, pendent holders, light fittings any type, sockets, regulators etc and making good disturbed surfaces of walls and floors etc to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge
Taking down carefully old distribution boards with MCB's single phase by unscrewing from boards complete all as specified and directed by Engineer-in-Charge.
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core including PVC rigid concealed conduit medium grade of suitable size (not less than 20mm dia) with all accessories such as bend reducers /MS hooks, MS junction boxes 2mm thick galvanized steel pressed sunken terminal boxes of suitable sizes for mounting of switches sockets, fan regulators etc covered with 2.8mm thick plastic laminate (Hylem/Anchor) top cover including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated stranded (Green colour) connected to common earth point dolly for One light point/call bell point/fan point to be controlled by one number one way PT switch complete all as specified and directed by Engineer in Charge.
All as per Srl item No. 159 here-in-before but Switch socket combination (multi purpose) 5 Pin 5 Amps 230 volts point to be controlled by one switch and wiring with 1.5Sqmm PVC unsheathed copper conductor cable 1.5 Sqmm PVC insulated earth wire on independent board.
All as per Srl item No. 159 here-in-before but on same board.
All as per Srl item No. 159 here-in-before Switch socket combination (multi purpose) 6 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5Sqmm PVC unsheathed copper conductor cable 2.5 Sqmm PVC insulated earth wire on Same board/independent board.complete all as specified and directed by Engineer in Charge.
S&F in replacement of switch Piano type single pole one way 5 Amp, 230 VAC supply complete all as specified and directed by Engineer in Charge.
S&F in replacement of socket two in one, 3 Pin 5 Amps 230 VAC supply, complete all as specified and directed by Engineer in Charge.
S&F in replacement of switch piano flush type single pole one way 15 Amps, 230 volts on laminated sheet top cover complete all as specified and directed by Engineer-in-Charge.(Note:-Sheet top cover included in point wiring)
S&F in replacement of socket piano flush type 6 pin 16 Amps, 230 volts complete all as specified & directed by Engineer-in- charge.
S&F in replacement of ceiling rose three terminals with bakalite 20mm back plate complete all as specified and directed by Engineer-in-Charge.
S&F in repair/ replacement 5 speed electonic regulator suitable for ceiling fan 1200mm/ 1400mm sweep, electronic type 230 Watt complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC Lamp holder suitable for and including batten fittings ,LED Lamp 9 watts with bakalite 20mm back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of complete set of tube light fitting, 1x18 watt LED (4 feet long) 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, decorative bipin holder, LED tube internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer in Charge. Make: Bajaj cat No.BCLSB 18W LED or Havells/Phillips
S&F in replacement of 1X9 watt LED retrofit type bulk head fitting luminaries die cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket, lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper coductor cable with suitable size of 230 volt,50 HZ complete all as specified and directed by Engineer-in-Charge. Make :Bajaj cat part no. BIBWP 10W LED or equivalent cat part of Philips / Havells
S&F in replacement of MCB distribution board double door of sheet metal single pole and neutral 8 way with 200 amps rated bus bar 240 volts complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCB ,SPN 240 volt 32 Amp complete all as specified and directed by Engineer-in-Charge. Make-Havells/Siemens/Legrand /Indo Asian.
S&F in replacement of MCB ,SPN 240 volt 63 Amp complete all as specified and directed by Engineer-in-Charge. Make-Havells/Siemens/Legrand /Indo Asian.
S&F in replacement of MCB single Pole 240 Volts 6 to 32 Amp complete all as specified and directed by Engineer in Charge. Make-Havells/Siemens/Legrand /Indo Asian.
S&F in replacement of MCB DB double door of sheet metal TPN 4 way with 415 Volts complete with and including MCCB 63 Amps with fixed thermal magnetic setting with breaking capacity not less than 16 KA complete all as specified & directed by Engineer-in-Charge.
Taking down old unserviceable sub main wiring of any size from wall and coduit etc complete all as specified and directed by Engineer-in-Charge..
S&F sub main wiring with two runs of single core PVC FRLS sheathed insulated copper cable of 10 sqmm size, multi stranded 1100 volts grade with PVC insulated FRLS copper wire 10sqmm for continous earth wire drawn into existing concealed conduit complete all as specified and directed by Engineer-in-Charge. Note ;- Two runs of 10 Sqmm copper cable and one run of 10 sqmm copper wire earth continuty conductor in existing conduit with accessories shall be measured as one length)
Supplying laying and fixing in replacement of XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with standard aluminium conductor 1100 volts grade confirming to IS-1554 cross sectional area 16 Sqmm 4 core including thimbles/lugs complete and passing through pipes or laid under floor or through walls etc including taking down old defective cable all as specified and directed. (Note : Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately)
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable complete all as specified and directed by Engineer in Charge.
M & L for sand cushioning with river washed and screened dry fine sand to under ground cable 23cm thick, 15 cm below the cable and 8 cm after laying the cable complete all as specified and directed by Engineer-in-Charge. NOTE;- Thickness after punning shall be considered for payment.
S&F Steel tubes 40mm bore light grade galvanised for cable protection fixed to poles/laid under floor/under road crossing with all fittings complete all as specified and directed by Engineer in Charge.complete all as specified and directed by Engineer-in-Charge.
M&L for MS clamp fabricated from MS flat of size 40mmx3mm including nuts, bolts, washers, bending cold or hot drilling holes for bolts in any shape or size for holding GI pipe with pole and wall complete all as specified and directed by Engineer in Charge.
S&F in replacement of LED Street light 25 watts Luminaries comprising of epoxy powder coated housing enclosed with glass cover incl 32mm bore (Light Grade) GI bracket, cable 1.5 Sqmm and fixing arrangement etc. complete all as specified and as directed by Engineer-in-Charge. Make : Bajaj Cat Part No. 16982 BCLST 25W LED or equivelant in Havells/ Philips
M & L Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) for watering and including funnel, wire mesh, RCC cover & frame, PCC (1:3:6) type C2 using 20mm graded crushed stone aggregate) as in earthing pit including necessary excavation and earth work, returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion complete all as specified and directed by Engineer in Charge. Note : The unit rate including earthing lead & protection pipe upto 7.5 meter from top to earth plate.
S&f Gun Metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed 25mm dia of pipe complete all as specified and directed .
S & F exhaust fan 300mm sweep, 380 RPM trans air (4 blade) 70 Watt, with louver shutter suitable for operation on 220/230 volts, single phase , AC and complete all as specified & directed by Engr-in-charge. Make : Crompton, Khaitan, Usha, Bajaj, Havells Note :- A Sum of Rs. 36,985.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 35 & 36 (Schedule of credit) of Tender Documents.
M/S BSS AND SONS
msgurjantconstructioncompany
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .