Executive Engineer
SMDA, Mansar
Providing and Installation of floating Jetty including gangway of Size 140 Sqm including consultancy charges of preparing structural drawings, design as per specifications at Surinsar. CNO38
2021_Tourm_145764_1
E-NIT No 22 of 2021-22 Dated 29-10-2021
Open Tender
Miscellaneous Works
Item Rate
20 days
Surinsar
refer PQ terms and conditions
2 documents required · 2 mandatory
₹2,000
CEO SMDA Mansar JK Bank
Exempted
2 Dec 2021
30 Oct 2021
16 Nov 2021
30 Oct 2021
15 Nov 2021
30 Oct 2021
Amount
SITC (Floating Jetties HDPE with M.S Barring Railing superior quality and Gangway of 6 meter length
Floating Jetty Modules Should be made of High-Grade High-Density Polyethylene whose melt flow rate should be less than 3 g / 10 min @ 190 Degree C and 21.6 kg Load
Floating Jetty Module should be of L: 50 cm, B: 50 cm, H: 40 cm
Weight of the Boat Parking Module should be 8-9 kgs
Load carrying capacity should be Minimum 300 kgs/sqm
The shape of the Floating Jetty Module should be 3-Dimensional male-female interlocking such that the Floating Jetty Module can interlock by themselves
Each Floating Jetty Module should have a Separate Anti-Skid Top Cover of 14-15mm Thickness fitted in the cervix of the main module
The top surface should be fitted inside the side walls of the Floating Jetty Module and it should be bolted in such a way that there should be no leakage of water from the point in which bolt is fixed between top and below surface thus making the surface the best Anti-Skid surface available worldwide
There should be one more surface below the top surface with a gap in between top surface and surface below to enable expansion contraction of Floating Jetty Module which can also be used for passing of electric cables & water hoses if required
The lug thickness of the Floating Jetty Module should be 20-21 mm to ensure enough strength to the structure
For Boats parking on Floating Jetty, HDPE ‘U Shaped’ Floating Jetty male-female interlocking module of dimension L: 100 cm, B: 50 cm, H: 29 cm and weight 11-12 Kgs should be fixed for smooth parking. The quantity of these modules should be dependent on-site requirement and it should be such that they can be interchangeable with the main modules if required
HDPE Heavy Duty Long Fender of L: 150 cm with 3 lugs to be fixed on the Floating Jetty Modules at required places using Nuts & Boats of same material to protect Floating Jetty System from being hit directly by the Boats
Aluminum Side Bars with Rubber must be fixed in the lugs of the modules at required places on Floating Jetty System to protect Floating Jetty System from being hit directly by the Boats
Human Safety Railings of MS powdered coated Material should be provided for human safety along the perimeter with PVC/Teak wood covering
1 number of Gangway of Length: 6 meter and width 1 meter should be provided. It should be hinged at the shore side and should have rollers at another end with ralling at sides
TECHNICAL DETAILS FOR BARRIER RAILING & GANGWAY
Barrier Railing of G.I powdered coated should be provided as per periphery of the Floating Jetty.
Gangway (1 No) L: 600 cm and B: 100 cm should be provided. It should be hinged at the shore side and should have rollers at another end.
TECHNICAL DETAILS FOR SOLAR FLOAT ( 2 Nos ) WALKWAY FLOATS ( 20 Nos)
Floating Solar Float Modules Should be made of High-Grade High-Density Polyethylene whose melt flow rate should be less than 3 g / 10 min @ 190 Degree C and 21.6 kg Load
Floating Solar Float Modules should be of L: 120 cm, B: 85 cm, H: 20/40 cm (approx.), Horizontal Supporting/Walkway Float Modules should be of L: 85 cm, B: 40 cm, H: 20 cm (approx.) (6 Nos) & Vertical Supporting /walkway float Modules should be of L: 45 cm, B: 40 cm, H: 20 cm (approx.) (14 Nos).
The Floating Solar Float Module should have sliding groove on the top, the clamping unit should have clips which can be moved in the groove relative to the float body and to hold different heights of solar panels
TECHNICAL DETAILS FOR SOLAR PANEL (2 panels) WITH LIGHT ( 2 nos )
Solar Panel should have Minimum Power -200 W, Open Circuit Voltage- 30 V, Minimum Power Voltage – 24.6 V, Operating Temperature - -40 to 85 Degree Celsius
Minimum 400-W power is required for operation of 2 Units of Pole Lights for minimum 12 hours and so 2 Units of Solar Panel of Minimum 200 W should be provided along with 2 Units of Pole Lights of suitable height and capacity
Minimum 1 Kwh battery system should be provided
Supplying of Life Jackets (Superior Quality) as approved by Engineer Incharge
Life Jacket should have Unique Stowage Design
Life Jacket should have 2 Nos. Reflective Tape Front / Back
Life Jacket should have 3 Nos. Polyester Webbing Belt attached with quick release Strong Buckle and Clip Slider Webbing Holder Easy to adjust
Time Marina INC
Litmus Marine Innovation P Ltd
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .