Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 CrAdmitted-Finance 1 20 ASAF ALI ROAD NEW DELHI 110002 | CENTRAL | DELHI | 110002 | ₹11.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹11.9 CrAdmitted-Finance | ₹11.9 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical 2ND FLOOR PADMA TOWER 1 5 RAJENDRA PLACE NEW DELHI DELHI 110008 | WEST DELHI | DELHI | 110008 | - | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | HPL Electric and Power Ltd L1 | AXIOM EXIM PRIVATE LIMITED L2 |
|---|---|---|---|---|---|
| 1.00Supply of Materials for Street Lighting with Single Arm(130 W LED LAMP WITH FIXTURE) | |||||
| 2.00 | Supply of 8.0 M hot dip galvanised octagonal pole with 1500 mm long decorative single arm bracket including foundation bolts. Each pole shall have a weather proof looping/termination box clamped at 550 mm shall be provided with a suitable earth terminal. Bakelite sheet shall be provided if the cable termination is inside pole with 2 nos. 6A SP MCB and other accessories as required. | 1,140 | Nos. | - | - |
| 3.00 | Supply outdoor type Feeder Pillar comprising of suitable FP MCCB 16 KA (Short circuit rating) as incomer and outgoing as TPN MCB 10 KA (short circuit rating) of suitable rating along with single dial timer & FP AC-1 wide band contactor of suitable rating along with GPRS based automatic ON/OFF controller as per technical specification. Proper ground clearance and foundation shall be provided. Other accessories if required will be in bidder's scope. | 38 | Nos. | - | - |
| 4.00 | Supply & Installation of Feeder Pillar Interface unit with Central server having web based SCADA software as per technical specification | 1 | No | - | - |
| 5.00Supply of armoured cable of 1.1 KV grade including excavation of trench/DWCHDP/GI pipe & backfilling with soft soil. | |||||
| 6.00 | a) 4 Core 25 sq mm. AYFY | 38,000 | m | - | - |
| 7.00 | b) 3.5 Core 35 sq mm. AYFY | 1,900 | m | - | - |
| 8.00 | c) 2 core copper 2.5 sqmm multi stranded flexible cable FR PVC insulated | 22,800 | m | - | - |
| 9.00 | Supply of 120/130 W LED Lamp with FIXTURE | 1,140 | Nos. | - | - |
| 10.00Supply of earthing | |||||
Tender Value
₹12.3 Cr
EMD Value
₹24.6 L
Closing Date
9 Oct 2020, 4:00 pmClosed
Manging Director, MSPDCL
Secure Office Building, 3rd Floor, North AOC, Imphal West, Manipur - 795001.
Supply, Installation and Commissioning of 1,140 Nos of Street Light on 8m long G.I. Octagonal Pole along with decorated Single Arm LED Lamp.
2020_MSPDC_1079_1
2/196(Street Light)/2020-MSPDCL-TECH/
Open Tender
Electrical Works
120 days
As per NIT
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Managing Director, MSPDCL
₹24.6 L
16 Oct 2020
26 Sept 2020
12 Oct 2020
26 Sept 2020
9 Oct 2020
28 Sept 2020
Supply of Materials for Street Lighting with Single Arm(130 W LED LAMP WITH FIXTURE)
Supply of 8.0 M hot dip galvanised octagonal pole with 1500 mm long decorative single arm bracket including foundation bolts. Each pole shall have a weather proof looping/termination box clamped at 550 mm shall be provided with a suitable earth terminal. Bakelite sheet shall be provided if the cable termination is inside pole with 2 nos. 6A SP MCB and other accessories as required.
Supply outdoor type Feeder Pillar comprising of suitable FP MCCB 16 KA (Short circuit rating) as incomer and outgoing as TPN MCB 10 KA (short circuit rating) of suitable rating along with single dial timer & FP AC-1 wide band contactor of suitable rating along with GPRS based automatic ON/OFF controller as per technical specification. Proper ground clearance and foundation shall be provided. Other accessories if required will be in bidder's scope.
Supply & Installation of Feeder Pillar Interface unit with Central server having web based SCADA software as per technical specification
Supply of armoured cable of 1.1 KV grade including excavation of trench/DWCHDP/GI pipe & backfilling with soft soil.
a) 4 Core 25 sq mm. AYFY
b) 3.5 Core 35 sq mm. AYFY
c) 2 core copper 2.5 sqmm multi stranded flexible cable FR PVC insulated
Supply of 120/130 W LED Lamp with FIXTURE
Supply of earthing
a) Each Street Light pole shall be provided with double coil earthing using 8 SWG GI wire wound to 50 mm diameter earth electrode and shall be connected to earthing stud of pole. The earth electrode shall be buried up to a depth of 1 M below the ground level.
b) Each distribution box shall be provided with 2 nos. 25* 3 GI Flat connected to 2.5 M long 40 mm dia GI pipe earthing at two place. Charcoal, salt and other accessories shall be as per IS
Supply of GI pipe for road crossings/ medians.
a) 80mm dia. GI pipe
b) 100mm dia. GI pipe
Supply of DWC HDPE pipe for cable laying between pole to pole.
a) 46-50 mm ID DWC HDPE
b) Cable connection and laying from source to distribution box.
Pole mounted 25 KVA Sub station materials
a) Supply of 25 KVA Distribution Transformer (level-ii)
b) Supply of 9 m Steel Tubular poles 410 SP-31
c) Supply of Pole mounted Distribution Sub station materials i.e, Channel for supporting Transformer, D.P. X-arm, for supporting HG fuse unit & A.B switch, for switch main channel X-arm, for supporting H.G. fuse main channel X-arm, Transformer belting angle & support, Clamp for transformer base channel for M.S. flat, Clamp for A.B. switch bracing, A.B. Switch, Horn gap fuse unit/D.O. fuse, 3 –Ph, D.B.box with complete accessories with Kit-Kat, cable, D.B.box cross arm, Sub-Station Earthing (Set of 3), Danger board, 11 KV lightening arrestor, Bolts,Nuts,clamps etc.
Description of Work / Item(s)
Erection of Materials for Street Lighting with Single Arm(130 W LED LAMP WITH FIXTURE)
Erectionof 8.0 M hot dip galvanized octagonal pole with 1500 mm long decorative single arm bracket including foundation bolts. Each pole shall have a weather proof looping/termination box clamped at 550 mm shall be provided with a suitable earth terminal. Bakelite sheet shall be provided if the cable termination is inside pole with 2 nos. 6A SP MCB and other accessories as required.
Construction of civil foundation for 8.0 M hot dip galvanized octagonal pole considering SBC as 10Ton/Sqmtr at a depth of 2Mtr from ground level. Foundation drawing has to be approved by the employer before commencement of work.
Erection outdoor type Feeder Pillar comprising of suitable FP MCCB 16 KA (Short circuit rating) as incomer and outgoing as TPN MCB 10 KA (short circuit rating) of suitable rating along with single dial timer & FP AC-1 wide band contactor of suitable rating along with GPRS based automatic ON/OFF controller as per technical specification. Proper ground clearance and foundation shall be provided. Other accessories if required will be in bidder's scope
Installation of Feeder pillar Interface unit with Central server having web based SCADA software as per technical specification
Erection of armoured cable of 1.1 KV grade including excavation of trench/DWCHDP/GI pipe & backfilling with soft soil
a) 4 Core 25 sq. mm. AYFY
b) 3.5 Core 35 sq. mm. AYFY
c) 2 core copper 2.5 sqmm multi stranded flexible cable FR PVC insulated
Erection of 120/130 W LED Lamp with FIXTURE
Erection of Earthing
a) Each Street Light pole shall be provided with double coil Earthing using 8 SWG GI wire wound to 50 mm diameter earth electrode and shall be connected to Earthing stud of pole. The earth electrode shall be buried up to a depth of 1 M below the ground level
b)Each distribution box shall be provided with 2 nos. 25* 3 GI Flat connected to 2.5 M long 40 mm dia GI pipe Earthing at two place. Charcoal salt and other accessories shall be as per IS
Erection of GI pipe for road crossings/ medians
80mm dia. GI pipe for median
100mm dia. GI pipe for road crossing trench size should be 1250 mm Depth and 500 mm Width
Laying of DWC HDPE pipe for cable laying between pole to pole
a) 46-50 mm ID DWC HDPE, trench size should be 600 mm depth and 300 mm width
b) Cable connection and laying from source to distribution box.
Pole mounted 25 KVA Distribution Sub station
a) Erection of Double Pole with 9 m Steel Tubular poles 410 SP-31
b) Erection of Pole mounted 25 KVA Sub station and its associated materials i.e, Channel for supporting Transformer, D.P. X-arm, for supporting, for HG fuse unit & A.B switch, for switch main channel X-arm, for supporting H.G. fuse main channel X-arm, Transformer belting angle & support, Clamp for transformer base channel for M.S. flat, Clamp for A.B. switch bracing, A.B. Switch, Horn gap fuse unit/D.O. fuse, 3 –Ph, D.B.box with complete accessories with Kit-Kat, cable, D.B.box cross arm, Sub-Station Earthing (Set of 3), Danger board, 11 KV lightening arrestor, Bolts,Nuts,clamps etc.
HPL Electric and Power Ltd
AXIOM EXIM PRIVATE LIMITED
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid