| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC 55 1 CHARAKDANGA NATUNPUKUR ROAD BARASAT KOLKATA 700124 | KOLKATA | KOLKATA | WEST BENGAL | 700124 | L1 | Accepted-AOC L1 | |
| 2 | L2₹37.2 L+₹27,527.38 (0.75%)Rejected-Finance GOALTULI CHARGHATA CHINSURAH DIST HOOGHLY WEST BENGAL PIN 712103 | CHINSURAH | HOOGHLY | WEST BENGAL | 712103 | L2 | Rejected-Finance Highest Amount Quoted | |
| 3 | L3₹39.6 L+₹2.6 L (7.12%)Rejected-Finance 14 HARE STREET GROUND FLOOR KOLKATA 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L3 | Rejected-Finance Highest Amount Quoted |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
19 Jul 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive_Engineer_PWD_Hooghly_Electrical_Division
Executive_Engineer_PWD_Hooghly_Electrical_Division
Electrical_Installation_works_incl_arrangement_of_alternative_power_back_up_for_proposed_PSA_Plant_at_Arambagh_SDH_and_SSH_in_the_District_of_Hooghly
2021_WBPWD_336473_1
WBPWD/EE/HED/SH/NIeQ-10/21-22
Open Tender
Electrical Work/ Equipment
Item Rate
15 days
HOOGHLY
Please refer Tender documents.
3 documents required · 3 mandatory
₹74,000
21 Sept 2021
14 Jul 2021
22 Jul 2021
14 Jul 2021
19 Jul 2021
14 Jul 2021
120 days
Amount
Supply , delivery at site on foundation of 250-KVA, 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-II approved Engine & Acoustic Enclosure having following specifications :-
ENGINE
Make: Cummins/Koel i-green(by Kirloskar)/Supernova Volvo/Greaves Power or other equivalent make as approved by E.I.C
Engine Type : 4 Stroke Diesel Engine
Rated Output : 306 BHP or Higher
Duty : PRIME
Cooling : Liquid Cooled
Cylinder : 6, In-line or higher
Aspiration : Turbo Charged, Charge air Cooled
Type of Governer : Electronic
Fuel Tank Capacity : Minimum capacity 450 Ltrs.
Fuel Consumption at 75% rated Load with Radiator or Fan : 46.7Ltr./ Hr. or Less
Fuel Consumption at 100% rated Load with Radiator or Fan : 58.3Ltr./ Hr. or Less
Overload Capacity : 10% overload for one hour for every 12 hours continious running at full load or better
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator
Exhaust Silencer : Residential Type
Starting system : 24V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning
Microprocessor based Controller with composite meter for digital display of following
Generator voltage/AC Mains voltage.
Generator Current in all phases
Frequency
Power Factor
Energy
Indication for alternator supply
Running time indications number of hours of operation and service intervals, service due indications, Low lubricating oil pressure, High water temperature, Start failure, and DG over load
ALTERNATOR
Make: Stamford/Kirloskar/Volvo/Greaves Power or other equivalent make as approved by E.I.C
Rating : 415 V., 3Ph. 50 Hz., 250 KVA, 1500 rpm
Type : Brushless, self excited and self regulated
Insulation : Class H
Protection : screen-protected drip proof with Min. IP-23 degree of protection
Voltage Regulation (max) : ±1%
Winding connection : Star with Neutral
Total Distortion factor : Less than 3%
Total Harmonic distortion in output waveform : No Load<1.5%, Non distorting balanced linear load<5%
AMF PANEL
Cubical type AMF panel outside DG canopy made from 14 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 250 KVA DG set having following specification/features.
i) 400A, 4P Power Contactor of 230V AC, AC1 Duty incl. Add on block for Power Contactor with 3NO+1NC - 2 Sets
ii) 415V AC Auxilary Contactor with 2NO+NC- 1 Set
iii) 230 V 6A SP MCB of 10KA- 1 No.
iv) 230 V 16A DP MCB of 10KA- 1 No.
v) 415V AC, 3 Phase Voltage Monitoring Relay incl. Auxilary Relay- 1 Set
vi) On -delay timer for load change over
vii) On-delay timer for engine shut off
viii) Engine On-Off switch (Push button type)
ix) Automatic Battery charger of I/P- 230V AC, O/P- 24V DC, 12 A. This will be in addition to the battery charging alternator fitted on the engine
x) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
ACOUSTIC ENCLOSURE
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustict enclosure must be certified as per CPCB-II norms.
BASE FRAME
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duty etc.
(ii) All materials, equipments & accessories must conform to relavent IS /IEC specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer.
(iii) Nacessary manufacturer's test certificate for Desiel Engin, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(iv) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competant Authority (As per CPCB-II).
(v) Circuit Diagram for AMF Panel must be submited from the Manufacturer/OEM.
(vi) The entire set must be warranted atleast 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier.
(vii) Necessary Control cable (12 Core 2.5 Sq.mm stranded armour copper cable) for connecting DG & AMF Panel - 5 mtrs. to be supplied on Free of cost
Extending the exhaust pipe with 150 mm. dia MS black pipe (Thickness 4 mm) including connection with the existing silencer attached with the flexible coupler and S&F flange, nuts, bolts & washers etc. & necessary fixing materials etc. as required from DG set upto 2.5 Mts high of the near higher installation with Asbestos rope / 2" glass wool insulation and chicken net and Aluminium fol covering, with end cap with suitable high temperature painting.
Making insulation by 2" glass wool including netting arrangement and covered with aluminium clading as per direction of the EIC.
a) 150 mm. dia exhaust pipe.
b) Residential type silenser pipe
S&F special type MS angle iron bracket support made of 40x40x6 mm. MS angle with flat iron clamp with nuts, bolts & washers etc. for (Vertical Run).
S&F rain protection canopy.
Filling of HSD oil for initial refill with transportation.
Supply and delivery of best quality oil hand pump with 1" dia PVC flexible pipe (10 mtr. approx.)
Supply and delivery of 200 ltr. Capacity heavy gauge MS barrel
Installation, Testing & Commissioning of 250 KVA Silent Diesel Generator Set with Acoustic Enclosure.
S& laying 120 sq. mm. single core multistrand PVC insulated flexible Cu cable in following manners from earth electrode to neutral earth busbar and from earth busbar to transformer neutral point as required (for transformer neutral earthing)
S& laying 2.5 sq. mm. 10core multi core multistrand PVC insulated flexible Cu cable in uPVC / GI pipe from DG to separate AMF panel.
Finishing the cable ends by crimping method incl. S&F copper socket, insulating tape and jointing materials etc. as required suitable for single core 120 sq. mm. copper wire.
Supplying and fixing of 415V, 415A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc as per GS [ Make- L&T/HPL/Havells as approved by EIC]. [3(a)/D-2]
Supplying and fixing 415V, 415A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [ Make- L&T/Siemens/Havells as approved by EIC]. [4(a)/D-3]
Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure suitable for following capacity with nuts bolts etc incl. powder coated painting.
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991)
4 bars of rating-415 V, 600 A with dimension of Cu bars [85mm long] :-(4 x (2x40x5mm)) ; Dimension of Sheet Metal Box:- 500x150mm. [ D-12/19(b)]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make- Nicco/Gloster/KEI/Havells as approved by EIC]
3.5 Core 185 Sq. mm
Laying of 2 cables in underground trench as per GS for the following numbers of Cables.
Above 35 and upto 185 Sq. mm [ 2(b)/ F- 2 ]
Laying of one cable of following size through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand as per GS.
above 150 sqmm and upto 300 sqmm [ 4(b)/ F-3 ]
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
Above 95 Sq. mm [ 5(iii)/ F- 3 ]
Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core as per GS. [3-a/F-1]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4/3.5)Core as per GS.
3.5Core 185 Sq. mm [ 7(d)/F4 & 8(b- xxi) /F5]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required as following size as per GS.
80 mm dia [11-f/F-6]
Distn. Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 19mm bore, 3mm thick polythene pipe complete with all accessories embedded in wall to light / Fan / Call bell point as per GS with with Modular type switch of black/grey clour (Legrand-Model Arteror/Myrius or equivalent model of Crabtree or Equivalent make as approved of E.I.C) following average run.
8 Mtr [1(iii) / E-20 ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with MODULAR type switch of black/grey colour (Make- Legrand Model- Arteror/Myrius or equivalent model of Crabtree/ Equivalent make as approved by E.I.C) as per GS.
On Board [ 3 (i) / E- 20 ]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
2+4 Way [Siemens Enclosure(8GB32102RC06) /L&T Enclosure-(LTSD06N) or equivalent model of Legrand/L&T] as approved by EIC. [ 13 / D- 9 & D-10 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC.]
Supply & Fixing Modular type 240 V, 16A, 3 pin plug socket with separate 16 A Modular type switch(Legrand-Model Arteror/Myrius or equivalent model of Crabtree) on sheet metal switch board embedded in wall as per GS. [ 9(b) / E-18]
Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube
Single fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3241 or equivalent model of Havells/CG / Bajaj / Wipro as approved by E.I.C] incl. 1 no. 18W Master LED Tube
Fixing only single/twin LED batten light fitting suspended from the ceiling fixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC [ 17/C-2 ]
Fixing only single/twin LED Batten light fitting complete with all accessories Directly on wall/ceiling as per GS.[ 14(d)/C-2 ]
Supply & fixing heavy duty Exhaust fan(Make-EPC) of followinng sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust incl. s&f louver shutter as per G.S. )
9"( 230mm ) Speed 1370 RPM
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS
S&F of 250V timer DB (equivalent to 8 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 20/25A DPMCB(C-curve 10ka) and 1 no 24 hr analog time switch and 1 no 18/25A power contactor complete with internal wiring with suitable size of copper wire including 1 no toggle switch and LED indicator and earthing attachment as per direction of EIC.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Extra for treatment of soil by using salt & charcoal or coke for plate electrode [3(b)/G-2]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [5(a)(i)/G-2]
No.-10 SWG [5(a)(iv)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 60 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as per GS. [4(c)/G-2]
Connecting the equipments body to earth busbar including S & F 50 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. as per GS. [5(e)/G-3]
Add GST @12% except item no. 6:- Rs.
Add LWC @1% except item no.- 1, 6, 7, 8, 17 & 30:- Rs
JANA AND COMPANY
Sohum Industrial Sales Corporation
stage.html
html • 0.05 MB
technical_641966.pdf
PDF • 0.61 MB
techsummary_641966.pdf
PDF • 0.76 MB
finance_641966.pdf
PDF • 0.50 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_641966.pdf
PDF • 0.48 MB
10.pdf
PDF • 0.10 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .