| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹30.7 L+₹75,148 (2.51%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹36.9 L+₹6.9 L (23.1%)Rejected-Finance MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance Third lowest amount quoted | |
| 4 | L4₹38.3 L+₹8.3 L (27.8%)Rejected-Finance | L4 | Rejected-Finance Highest amount quoted |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
7 Sept 2021, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2021_MES_465736_1
8337/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
Garrison Engineer (East) Jabalpur
D a(ii)
9 documents required · 9 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹88,000
Yes
30 Sept 2021
6 Aug 2021
9 Sept 2021
6 Aug 2021
7 Sept 2021
23 Aug 2021
6 Aug 2021 - 18 Aug 2021
Amount
Excavation in trenches in soft / loose soil not exceeding 1.5m wide and not exceeding 1.5m deep and getting out complete all as specified and directed.
Returning, filling in including spreading, leveling and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated material n.exc. 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point.
M&L for repair- of leakages GI pipe of size 20 mm by replacing the Tees, bends, sockets unions etc complete including all acessories with necessary exacavation and earth work; returning filling & removal for that job, all as specified and directed by Engineer-in-Cahrge.
All as per item srl no 4 here in before but size 25mm bore.
All as per item srl no 4 here in before but size 40mm bore.
All as per item srl no 4 here in before but size 50mm bore.
All as per item srl no 4 here in before but size 80mm bore.
M&L repairing of leakages of CI/DI pipes of size 80 mm by replacing the Tees, bends, sockets and providing the other materials required at site such as lead joint, to complete the job including excavation and other earth work returning filling and removal. Note :- CI/DI bends, sockets,Y juction,cross,collars,cap,lead joint/tighten joint and connected items will be measured and paid separately
All as per item srl no 9 here in before but size 100mm bore.
All as per item srl no 9 here in before but size 150mm bore.
All as per item srl no 9 here in before but size 200mm bore.
Material and labour for ISI marked CI/DI pipe fittings up to size 80 to 300 mm dia such as bends, Tapers tail pieces, Tee pieces , caps and plug set including rubber ring push on joints complete as specified and directed.
Taking up or down existing 20mm GI pipe lines for relaying /refixing at site existing/connected all as directed .Note excavation and earthwork can be measured sepratly.
All as per item srl no 14 here in before but size 25mm bore.
All as per item srl no 14 here in before but size 40mm bore.
All as per item srl no 14 here in before but size 50mm bore.
All as per item srl no 14 here in before but size 80mm bore.
S & F of GI tubing , medium grade, galvanised, with all fittings, laid in trenches of size 20mm bore complete all as specified and directed.
All as per item srl no 19 here in before but size 25mm bore.
All as per item srl no 19 here in before but size 40mm bore.
All as per item srl no 19 here in before but size 50mm bore.
All as per item srl no 19 here in before but size 80mm bore.
Cleaning of retrieved 20mm bore GI pipe lines and laying in trences the same after cleaning internally (by cleaning brush) and externally (by scrapping and washing) including replacing GI fittings all as directed .
All as per item srl no 24 here in before but size 25mm bore.
All as per item srl no 24 here in before but size 40mm bore.
All as per item srl no 24 here in before but size 50mm bore.
All as per item srl no 24 here in before but size 80mm bore.
S&F in replacement of gun metal/globe or gate valves of 20mm dia with iron wheel head, ISI marked confirming to IS-780, screwed both ends for iron pipe and fixed complete all as specified.
All as per item srl no 29 here in before but size 25mm bore.
All as per item srl no 29 here in before but size 40mm bore.
All as per item srl no 29 here in before but size 50mm bore.
Dismentling old unserviceable valve pits and M & L for constructing of brick masonary pits (as per drawing No CEJZ/TD/819/91 dated 16/04/91) of internal dimensions 1mtr x1mtr x1.2 mtrs ( bottom PCC floor of the pit should be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space) , bottom floor of the pit be constructed in PCC (1:4:8) type D-2 in foundation 15 cms thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 MM thick. 150mm thick copping on top in PCC (1:3:6), type C-1 .The sluice valve and other fittings should be housed in center of the pit. the vertices of the pit should in right angle and champhered .The top cover of the pit will be made out of MS sheet min 3mm thick witth angle iron frame made out of MS angle 50mm x50 mmx 6 mm with galvanised steel hindges two nos ,and locking arrangements duly painted with two coats of water resistant synthetic enamelled paint over one coat of red oxide and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing.
All as per item srl no 33 here in before but size 900X900X900 mm.
All as per item srl no 33 here in before but size 600x600x600 mm.
Taking out existing 80 mm bore CI/DI pipe lines and stacking at site for disposal or reuse all as directed . Note : Excavation/Earthwork shall be measured and paid separately
All as per item srl no 36 here in before but size 100mm bore.
All as per item srl no 36 here in before but size 150mm bore.
All as per item srl no 36 here in before but size 200mm bore.
M&L for DI pipes K-7 size 80mm bore with spogot and socket ends all as directed .
All as per item srl no 40 here in before but size 100mm bore.
All as per item srl no 40 here in before but size 150mm bore.
All as per item srl no 40 here in before but size 200mm bore.
Supply and fix in replacement of CI sluice valve with forged brass stem class PN- 1.6 ISI marked with stainless steel spindal and flanged both ends of size 80 mm dia bore with hand wheel confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm complete all as specified and directed. Make : Kirloskar/L&T/ Upadhyayal as directed.
All as per item srl no 44 here in before but size 100mm bore.
All as per item srl no 44 here in before but size 150mm bore.
All as per item srl no 44 here in before but size 200mm bore.
M&L run lead joint 80 mm dia complete all as specified and directed by engr-in - Charge.
M&L run lead joint 100 mm dia complete all as specified and directed by engr-in - Charge.
M&L run lead joint 150 mm dia complete all as specified and directed by engr-in - Charge.
M&L run lead joint 200 mm dia complete all as specified and directed by engr-in - Charge.
S&F in replacement Hydrant valve 63 mm dia, made out of gun metal heavy duty with female coupling outlet complete with blank cap chain as per IS-5290 and ISI mark complete all as specified and directed by engr-in - Charge. Make : Kirloskar/L&T/Upadhyay
S&F in replacement Hydrant valve lugs of gun metal for above type of valve complete all as specified and directed by engr-in - Charge. Make : Kirloskar/L&T/Upadhyay.
S&F in replacement Hydrant valve wheel cost iron type complete all as specified and directed by engr-in - Charge. Make : Kirloskar/L&T/Upadhyay
S&F in replacement Hydrant cap with chain for hydrant valve 63mm dia complete all as specified and directed by engr-in - Charge.
S&F in replacement FLX/RRL canvas hose ( 15 m length ) with end fittings, male & female extra coted with outer special elastomeric coting circularly wove jacket manufactured by 100% high density synthetic yarn inset again milded anti rot lined with special compound synthetic rubber with bursting pressor of 40 Kg per cm sq bearing ISI mark under IS No. 636-1988 type 'A' binded with heavy duty male & female coupling.
S&F Hose box made of 18 gauge MS sheet 800mm x 600mm x250mm with double door with 4 mm thick glasses and door frame made of gauge MS sheet painted fire red outside and brilliant white inside depot with PCC foundation complete all as specified and directed by engr-in - Charge.
S&F in replacement of MCCB 3 pole, 250Amp, 415V in to the existing panel board with new one of same size and capacity complete. Make : L&T/Havels/Legrand/Schnieder
Supply & fix spare parts kit for 3 pole power contractor 45Amps, 440 volts, with coil rating 230/440 volts complete of type ML-3. Make : L&T/Legrand/Schnieder
Supply & fix spare parts kit for 3 pole power contractor 70Amps, 440 volts, with coil rating 230/440 volts complete of type ML-4. Make : L&T/Legrand/Schnieder
S&F 3 pole power contractor 110 Amps, 440 volts, with coil rating 230/440 volts complete of type ML-6. Make : L&T/ Legrand/Schnieder
S&F 3 pole power contractor 70Amps, 440 volts, with coil rating 230/440 volts complete of type ML-4. Make : L&T /Legrand/Schnieder
S&F 3 pole power contractor 45Amps, 440 volts, with coil rating 230/440 volts complete of type ML-3. Make : L&T/Legrand/Schnieder
Supply & fix spare parts kit for 3 pole power contractor 110Amps, 440 volts, with coil rating 230/440 volts complete of type ML-6. Make : L&T/Legrand/Schnieder
S&F Bimetalic Overload relays suitable for Power Contactor 40Amps, 440 volts, with coil rating 230/440 volts complete of type ML-3. Make : L&T/Legrand/Schnieder
S&F Bimetalic Overload relays suitable for Power Contactor 70Amps, 440 volts, with coil rating 230/440 volts complete of type ML-4. Make : L&T/Legrand/Schnieder
S&F Bimetalic Overload relays suitable for Power Contactor 110Amps, 440 volts, with coil rating 230/440 volts complete of type ML-6. Make : L&T/Legrand/Schnieder
S&F Pressed leather gasket for CI for foot valve 200 mm. Make : Expart/existing make as approved by GE.
S&F Pressure gauge range 0 - 21 Kg cm Sqr, Make : Expart/existing make as approved by GE.
S&F Presser switch range 01 to 10 bar type RT-116, Code No. 17-5203, Make :Indofoss
S&F CI Foot valve 150 mm dia confirming to IS-4038-1986, Make : Expart/existing make as approved by GE.
M&L for road cutting, including excavation returning filling in spreading leveling, well ramming in layers, swelling with broken boudders/stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix, carpetting 25 mm thick using ready mix patch mate material, rolled & compacted for rpad patch repair work coomplete all as specified and directed.
Manning, operation and routine maintenance of water supply installation (pump house) with deputing of one skilled FGM operator of proper trade with ITI qualified having minimum 04 years of experience for round the clock of three shift of 08 hours each shift (for 24 hours daily including Sunday and holidays) for operation of pump sets, chloronome plant/BP Dozer for proper pumping from new map pump house near 4 tank to CMM (all OHTs ie , 1,00,000 GLN-1 NO, 20,000 -GLN 1 NO ,50,000 GLN-4 NOS) including operation of all valves, maintaining all equipment of pump house in perfect condition and keep it up always in inspection condition, cleaning of all water supply installation and surrounding area all specified and directed by Engr-in-charge. The installation comprises the following :- (i) Centrifugal pump sets 7.5 HP - 02 Nos , (ii) dosing plant - 01 No, (v) DG sets 30 KVA- 01No , (vi) control panel boards of centrifugal pump sets and operating delivery valve,distribution of water supply. Note : If quoted rate are less than min fare wages including GST the bid shall be treated as non bonafide and shall be rejected
Manning, operation and routine maintenance of water supply installation (pump house) with deputing of one skilled FGM operator of proper trade with ITI qualified having minimum 04 years of experience for three shift of 8hrs (for 24 hrs daily including Sunday and holidays) for operation of pump sets, chloronome plant/BP Dozer for proper pumping in new map pump house near 506 ABW (all OHTs) including operation of all valves, maintaining all equipment of pump house in perfect condition and keep it up always in inspection condition, cleaning of all water supply installation and surrounding area all specified and directed by Engr-in-charge. The installation comprises the following :- (i) Centrifugal pump sets 7.5 HP - 02 Nos ,(ii) submersible pump sets 12.5 HP - 02 Nos , (ii) dosing plant - 01 No, (v) DG sets 50 KVA- 01No , (vi) control panel boards of centrifugal pump sets and operating delivery valve,distribution of water supply to complete area Note : If quoted rate are less than min fare wages including GST the bid shall be treated as non bonafide and shall be rejected.
Notes for item Nos – 73, 74 as follows:- To maintain log sheet and log books for all installations and monthly duty roaster for duty staff.
POL chlorine gas or bleaching powder shall be arranged by the Engr-in-Charge as per requirement and issued to contractor under schedule B free of cost for bonafide Government use only & a pucca bound register shall be maintained showing day to day input/output only signed by JE/Engineer-in-charge/Contractor.
The unit per day means 24 hours. The contractor shall deployed one FGM per shift of 08 hours at installation viz 3 different FGM per day.
Pumping supply hrs shall be observed as mentioned in particular specification here in after or as directed.
One pumping set shall be work at a time.
Timing shall be decided by GE as per requirements.
It is the responsibility of the contractor that chlorine plant/BP dozer are to be operated at the time of supply of water.
The quoted rate shall be deemed to include for all surrounding premises cleaning such as in side the pump, outside, toilet including cutting of grass shrubs etc and always keep ready position whenever any visiting officer visits the site the pump houses should be cleaned and neat in all respect. In case any bad/adverse remark given by any visiting officer at any time the necessary recovery @ double the rate quoted per day shall be charged from the contractor as certified by Engineer-in-Charge and no claim whatsoever is admissible on the account, GE’s decision is final and binding on this account.
Testing water for residual chlorine and PH value and maintain directed level as directed and proper register to be maintained.
Gland packing, greasing and oiling of centrifugal pump sets shall be done monthly and proper register shall be maintained duly signed by the contractor, Engr-in-Charge & JE.
Trades men should be wear always Operators uniform and take preventive /safety measures and will use protective clothing as per code of IE rules safety code. Department will not responsible for any type of incident.
Contractor shall be made security pass for all operators and maintain proper register duly signed by all concerned.
T&P like spanners, screw drivers, pipe wrench, torch light, other items required for repair etc. will be provided by the contractor.
It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duly signed kept on record and payment of trade men for the Nos of days present will only be made, Engineer-in-Charge will be responsible for payment of trade men in his presence. Contractor shall provide proper dress to tradesmen as approved by Eng-in-Charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues.
In case the contractor does not operate the pumping set for a day or part thereof due to any reason whatsoever double of the quoted rate to each day will be recovered.
Leave of deployed person in inescapable cases shall be allowed on prior intimation but Contractor on demand of Engineer-in-Charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.
In no case wages of deployed persons shall be less than the Minimum wages fixed by Govt Competent Authority. It is mandatory requirement for Contractor that payment of deployed person shall be made through Cheque/RTGS/Acceptable Electronic Mode only. Proof of payment shall be submitted by Contractor to Engineer in Charge monthaly basis or during claiming on account of Advance (RAR)/FB.
The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952. shall be strictly adhered to by the Contractor. Social Security to workers i.e. EPF, ESIC, Personal Insurance(if applicable) on part of Employer shall be paid by Contractor and accordingly, Contractor/Bidder shall include all these factors in his quoted rate.
Statuatory levies/GST if applicable on part of contracts shall be paid by Contractor and accordingly, Contractor/Bidder shall include all these factors in his quoted rate.
Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting Officer for their attendence & obtain instructions. An attendence register shall be maintained by Contractor on site shall be certified by MES rep every day.
T&P - Working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by Contractor at his own cost.
Retrieved materials obtained from replacement by new items shall be deposited in MES store.
An uniform of blue shirt/jersy duly embossed "MES OUTSOURCING SERVICES" at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.
Water & electric supply shall be provided by MES free of cost for outsourcing services only.
Documentation - Attendance register & wages register,Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost.
Taking up Submersible Pump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 17.5HP/15 HP Pump Set .(i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3phase ,taking out burnt winding wire, with & including PVC insulated water proof copper wire with winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 17.5/15 HP submersible pump of any make including carrying out painting by two coats of synthetic enamelled paint over a coat of primer,assembling the pump and motor including testing complete all as specified and directed.
Note for item No 76 (i) Cost of disconnection of electric connection from LT control panel & starter of submersible pumping set & reconnecting with existing pipe and making electrical connection with panel board & starter shall be included in the quoted rate of these items. (ii) Cost of lowering of submersible pump set of any size after repairs and re-connecting with existing pipe shall be included in the quoted rate of these items. (iii) Cost of spare parts shall be included in the quoted rate of these items. (iv) The contractor shall be repair the submersible pump and motor within 72 hours after receiving the complaint failing which recovery/penalty shall be imposed @ Rs 500.00/day. The same shall be recovered from the RAR/FB.
M&L for Rewinding the motor with super enamelled copper winding wire with appropriate same gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations as directed by engr-in-charge.Make:Atlas/BWC/Swastik/Chetak
Taking down unservicable existing cable from motor/pannel to starter any size/capacity.
S & F PVC Insulated unsheathed cable 37/1.56 mm dia single core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Finolex/polycab/plaza
S & F PVC Insulated unsheathed cable 19/2.16 mm dia single core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Finolex/polycab/plaza
Cutting and threading of existing GI pipe 80 mm dia complete all as specifed and directed.
S&F GI long socket suitable for 80 mm dia and 100 mm long complete all as specifed and directed.
Schedule of credit amount of Rs. 2,45,620.00 to be deducted during AOC
Goodluck Enterprises
RAVINDRA ELECTRICAL
M/s Ajayshwar Singh Rana
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .