Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 CrAccepted-AOC | ₹13.1 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹13.9 CrRejected-Finance | ₹13.9 Cr | L2 | Rejected-Finance Since not L1 |
| 3 | L3₹14.1 CrRejected-Finance | ₹14.1 Cr | L3 | Rejected-Finance Since not L1 |
| 4 | L4₹14.7 CrRejected-Finance NO 60 ELDAMS ROAD TEYNAMPET CHENNAI TAMIL NADU 600 018 | CHENNAI | CHENNAI | TAMIL NADU | 600018 | ₹14.7 Cr | L4 | Rejected-Finance Since not L1 |
| 5 | L5₹14.8 CrRejected-Finance | ₹14.8 Cr | L5 | Rejected-Finance Since not L1 |
Tender Value
₹10.2 Cr
EMD Value
₹8.3 L
Closing Date
12 Nov 2022, 6:00 pmClosed
CHIEF ENGINEER COAST GUARD VISAKHAPATNAM
Office of HQ CE CG Visakhapatnam-530007
PROVISION OF DEF MD ACCOMMODATION TYPE IV (SPL) AND TYPE V AT NEW CGRA NEAR CAMP UNDER ICGS MANDAPAM
2022_MES_538331_1
CE (CG) /VIZ/MDP/TOKEN 08 OF 2022-23
Open Tender
Civil Works
610 days
Manndapam
As per tender documents
8 documents required · 8 mandatory
₹3,000
Garrison Engineer I CG CHENNAI
₹8.3 L
Yes
21 Dec 2022
15 Jul 2022
14 Nov 2022
15 Jul 2022
12 Nov 2022
25 Oct 2022
Amount
Schedule "A" Part – I to Schedule "A" Part – XIII: NOTE: Schedule "A" Part – I to Part – XII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lump Sum price worked out by the contractor for "BUILDINGS & STRUCTURES", for the lumpsum price of Rs. 6,63,69,000.00 inserted by MES as listed in Schedule 'A' Part - I on Serial Page No. 32 (R) (R)
Price worked out by the contractor for "EARTH WORK, SITE CLEARANCE AND AREA DEVELOPMENT ", against the price of Rs. 68,62,185.49 inserted by MES as listed in Schedule 'A' Part - II on Serial Page No. 33 (R) (R)
Price worked out by the contractor for "INTERNAL WATER SUPPLY", against the price of Rs. 4,69,892.90 inserted by MES as listed in Schedule 'A' Part - III on Serial Page No. 35( R)(R)
Price worked out by the contractor for "INTERNAL ELECTRIC SUPPLY", against the price of Rs. 6,42,032.13 inserted by MES as listed in Schedule 'A' Part - IV on Serial Page No. 38 (R) (R)
Price worked out by the contractor for "EXTERNAL WATER SUPPLY", against the price of Rs. 9,18,317.33 inserted by MES as listed in Schedule 'A' Part - V on Serial Page No. 39(R )(R)
Price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY", against the price of Rs. 7,88,049.23 inserted by MES as listed in Schedule 'A' Part - VI on Serial Page No. 41( R)( R)
Price worked out by the contractor for "AREA DRAINAGE", against the price of Rs. 57,41,061.54 inserted by MES as listed in Schedule 'A' Part - VII on Serial Page No. 42( R)( R)
Price worked out by the contractor for "SEWAGE DISPOSAL", against the price of Rs. 35,00,175.32 inserted by MES as listed in Schedule 'A' Part - VIII on Serial Page No. 45(R)( R)
Price worked out by the contractor for "ROAD/PATH/HARDSTANDING/CULVERT WORK", against the price of Rs. 50,25,962.50 inserted by MES as listed in Schedule 'A' Part - IX on Serial Page No. 47 (R )(R )
Price worked out by the contractor for "FENCING COMPOUND WALL AND GATE", against the price of Rs. 86,29,048.03 inserted by MES as listed in Schedule 'A' Part - X on Serial Page No. 51( R)( R)
Price worked out by the contractor for "LIGHTENING PROTECTION AND OBSTRUCTION LIGHT WORK", against the price of Rs. 73,640.00 inserted by MES as listed in Schedule 'A' Part - XI on Serial Page No. 52(R)( R)
Price worked out by the contractor for "FIRE FIGHTING AND FIRE ALARM SYSTEM", against the price of Rs. 2,32,737.55 inserted by MES as listed in Schedule 'A' Part - XII on Serial Page No. 55(R)(R )
Schedule "A" Part - XIII [Miscellaneous Items]
INTERNAL WATER SUPPLY
Item No 1 : S&F two way bib cock with wall flange quarter turn (Low-flow) 16 mm dia. complete all as specified and directed by Engineer-in-Charge Make - Jaquar Model No KUP-35041PMGE or equivalent in Crab Tree/Kohler brand
Item No 2 : S & F Hand shower (Health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back flow preventer) complete all as specified and directed by Engineer-in-Charge Make - Jaquar Model No ALD-579 or equivalent in Crab Tree/Kohler brand
Item No 3 : S & F Angular Stop Cock 15 mm bore of pipe (16 mm outer dia) with Wall Flange chromium plated Stop valves complete all as specified and directed. Make - Jaquar Model No KUP-35053PM or equivalent
Item No 4 : S & F Wall Mixer with Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flanges complete all as specified and directed. Make - Jaquar Model No FUS-29273UPR or equivalent
Item No 5 : S & F Toilet paper holder of stainless steel recessed type fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. Make - Jaquar Model No FUS-29273UPR or equivalent
INTERNAL ELECTRIFICATION
(a) One light point/security light/ceiling/exhaust/wall mounted fan controlled by one switch
(b) One 3 pin socket outlet , 5 Amps on an same board controlled by one switch
(c) One 3 pin socket outlet , 5 Amps on an independent board controlled by one switch .
(d) One light point controlled by two way switch
(e) One bell point controlled by one switch
Item No 7 : M & L for One 3 pin socket, 25/32 Amps confirming to IS 1293:2005 complete all as specified in IS 732: 2019 and directed by the Engineer-in-Charge.
Item No 7A: M & L for point wiring using 1.1 kV grade single core FR-LSH flexible cable 2.5 sqmm, conforming to IS 694: 2010, having multi-drawn thin strands of electrolytic copper conductors and insulation for phase, neutral, and earth continuity conductor connecting to earth dolly, colour-coded as per IS 11353: 1985, drawn in medium grade UPVC surface / recessed conduits, conforming to IS 9537 (Part- 3): 1983, of size not less than 20 mm NB, including cutting chases, factory made not less than 1.2 mm thick sunken, modular flush sheet galvanized metal enclosure having zinc coating not less than 120 GSM, , conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover-plates and making good of disturbed surfaces of wall / ceiling / floor, etc. complete all as specified in IS 732: 2019 and directed by the Engineer-in-Charge.
Item No 8 : M & L for point wiring using 1.1 kV grade single core FR-LSH flexible cable 4.0 sqmm, conforming to IS 694: 2010, having multi-drawn thin strands of electrolytic copper conductors and insulation for phase, neutral, and earth continuity conductor connecting to earth dolly, colour-coded as per IS 11353: 1985, drawn in medium grade UPVC surface / recessed conduits, conforming to IS 9537 (Part- 3): 1983, of size not less than 20 mm NB, including cutting chases, factory made not less than 1.2 mm thick sunken, modular flush sheet galvanized metal enclosure having zinc coating not less than 120 GSM, , conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover-plates and making good of disturbed surfaces of wall / ceiling / floor, etc. complete all as specified in IS 732: 2019 and directed by the Engineer-in-Charge.
Item No 9 : S & F modular type 25/32 A SP MCB, conforming to IS 60898- 1: 2002 complete all as specified in IS 732: 2019 and as directed by Engineer-in-Charge.
Item No 10 : MCB for AC applications and others 6- 32 A, 230 V, 50 Hz, SP MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. as specified in IS 732: 2019 all as directed.
Item No 10A : MCB SPN 240 volts, 32A, C series, breaking capacity 10kA complete all as specified and as directed., sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. as specified in IS 732: 2019 all as directed.
Item No 11 : MCB for AC applications 6- 32 A, 230 V, 50 Hz, DP MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. as specified in IS 732: 2019 all as directed.
Item No 16 : M&L LT Panel Board and Supply Fabricate, install, connect, test and commission Outdoor type dust & Vermin proof LT electrical panel board, 1100 volts, 50 Hz AC supply, fully compartmentalized for cable chamber and bus bar chambers with adequate space made out of 3.15 mm thick CRCA sheet steel for load bearing like all over body, front and back cover with hinges and aldrops with DC locks and one seven lever Navtal lock etc complete with 1 mm thick FRP coated all over the external surfaces and 2.0 mm thick MS Sheet for non-load bearing and portions, complete with one coat of red oxide primer , two coats of powder coating including suitable angle iron/ flat iron frame work/ supports bottom 50x50x6 mm MS channel as base and chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminum strip/ rods insulated and FRLS copper conductor complete mounted on PCC pillars foundation, cable connection using new lugs complete with danger notice all as specified and comprising of the followings:-Note: (i) Existing cables which removed from old panel board will be fixed with new lugs during fixing in new panel board (ii) Getting of approval for Panel board drawing from Engr-in-Charge is necessary before fabrication. (iii) All swith gears should be fixed with 06 mm thick Fiber sheet (LT Panel 1Near Existing Power House) a) LED/Neon indicator bulb in RYB Colour - 1 Set. b) 4 No Bus bar 400 amps with chamber c) Digital Voltmeter 0-500 volts, and Digital Ammeter 0-500 Amps of suitable size - 01 Set d) 3 phase over current and Earth fault relay range (250-400 Amps) with RS 485, Make : L&T, Cat No : 17K726QF4M -01 No
INCOMING e) MCCB 4 Pole, 415 V, Microprocessor release, Adjustable overload type, 400 A with breaking capacity 36 KA, Make : L&T, Type : DN3-400D Cat No : CM93003003OOOOX1- 01 Nos OUTGOING f) MCCB 4 Pole, 415 V, Thermal Magnetic release, Adjustable type, 160 A with breaking capacity 25 KA, Make : L&T, Type : DN2-250D, Cat No : CM92009OOP1OG- 03 Nos g) MCCB 4 Pole, 415 V, Thermal Magnetic release Adjustable type, 100 A with breaking capacity 25 KA, Make : L&T, Type : DN0-100C, Cat No : CM91712OOKOOG- 01 Nos
Item No 16A : Supply, installation, testing and commissioning of factory made, type tested by CPRI / ERDA for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, outdoor cubical compartmental type MAIN LT Panel of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 53 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed on wall / in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by Engineer-in-Charge :- The MAIN LT Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 200 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection
[B] INCOMING [i] 63 A, 415 V, 50 Hz 4 Pole MCCB conforming to IS/IEC 60947-2, having Icu = 100% Ics = 25 kA, thermal magnetic (TM) release, trip alarm contact, shunt release, under voltage release, rotary operating mechanism (direct / extended), spreader terminals, key lock, 01 Set (3L + N) of copper busbar of suitable rating, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING [i]40 A, 30 mA, 415 V, 50 Hz, FP RCBO, key lock, 01 Set (3L ) of copper busbar of suitable rating, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 04 Nos. [ii] LED phase indicators (Red, Yellow, Blue)- 03 Set [iii] Supplying and fixing smart three phase3x440 V,10-60 A,Accuracy Class 1.0 As per IS 16444 part -I,smart energy meter Prepaid or Postpaid with 4G/GPRS based Communication meters for remote reading complete all as specified and directed-04 Nos.
Item No 17 : S & F surface / wall mounted LED batten capable of delivering 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and as directed. Make: Philips Cat-Part No. BN 021C LED20S- PSU CW GR S2 or equivalent model of Havells Cat-Part No. LHEXAPP7IN1W020 or Wipro Cat-Part No. LL20-281-XXX-65AL1
Item No 18 : S & F 3-star (EEL) T-shape lamp capable delivering 1000 lumen having luminous efficacy of > 100 lm/W, starting time < 0.5 s, CRI > 80, CCT 6500K, PF >0.9, input voltage range 140- 270 V, input frequency 50- 60 Hz and B22 socket complete all as specified and directed by the Engineer-in-Charge. Make: Philips Cat-Part No. T- Bulb CW 10W B22 or equivalent model of Havells Cat-Part No. LHEXACP7FN1W010 or Wipro Cat-Part No. LL20-111-XXX-65-NE
Item No 19 : S & F LED Bathroom light suitable for wall mounting & 220- 240 V, 50 Hz mains voltage with built-in LED & driver, power rating ≤ 8 W, including IP 20 protection as well as electrical connection with 3 core 1.0 mm² PVC insulated copper conductor unarmoured cable to the fixture complete all as specified and directed by the Engineer-in-Charge. Make: Philips Cat-Part No. 34034/14/86 or equivalent model of Havells Cat-Part No. LHLDEUECNL8R009
Item No 20 : S & F LED Mirror light suitable for wall mounting & 220- 240 V, 50 Hz mains voltage with built-in LED & driver, power rating ≤ 8 W, including IP 20 protection as well as electrical connection with 3 core 1.0 mm² PVC insulated copper conductor unarmoured cable to the fixture complete all as specified and directed by the Engineer-in-Charge.
Item No 21 : S & F LED light fixtures 10/12 watt round LED ceiling mounted polycarbonate environmental friendly ,Energy efficient not less than BEE 4-star rated fixed on ceiling & connecting upto ceiling rose/point wiring with three core PVC insulated 1.5 Sqmm PVC copper conductor cable with earthing complete all as specified and as directed.
Item No 22 : S & F LED light fixtures 20 watt round LED ceiling mounted polycarbonate environmental friendly ,Energy efficient not less than BEE 4-star rated fixed on ceiling & connecting upto ceiling rose/point wiring with three core PVC insulated 1.5 Sqmm PVC copper conductor cable with earthing complete all as specified and directed by the Engineer-in-Charge.
Item No 22A : Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete, 4 feet and luminous efficacy more than 120 lm/W with integrated sleek extruded polycarbonate Endura LED Channel available with 6500 K CDL with white acrylic cover and mounting accessories, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from ceiling rose to fitting etc, Energy efficency not less than BEE 4 Star rating, complete all as specified and as directed.
Item No 23: Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete, 2 feet and luminous efficacy more than 120 lm/W with integrated sleek extruded polycarbonate Endura LED Channel available with 6500 K CDL with white acrylic cover and mounting accessories,complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from ceiling rose to fitting etc, Energy efficency not less than BEE 4 Star rating, complete all as specified and as directed.
Item No 24 : S & F 25 W street light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 2600 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high efficacy polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, pole mounting with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Item No 25: Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engineer-in-Charge.
Item No 26 : Supply and fix Wall mounting fan BLDC32 watt 400 mm sweep confirming to Energy Efficient Bee 5- star rated including connecting to point wiring complete all as specified and directed by Engineer-in-Charge.
Item No 27 : Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed by Engineer-in-Charge.
Item No 28 : Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed by Engineer-in-Charge.
Item No 29 : (i) Implementation of cloud based meter data acquisition system through server including required soft ware, data base defining mapping of consumers and running the vending system for each meter ( Up to 50 nos of Meters) complete all as specified and directed by Engineer-in-Charge. Note: 12 Nos os smart meters is to be installed which has been catered in the building panels under respective item. (ii) Recurring charges for maintaing cloud software and data on yearly basic. (After completion of building work for the 2 years during the DLP. (iii) Recurring charges for maintaing sim cards charges for 12 meters on yearly basic. (After completion of building work for the 2 years during the DLP. Note: (a.) SIM card should be IPV6 based & with static IP (.b): 12 Nos os smart meters is to be installed which has been catered in the building panels under respective item.
Item No 30 : Supply and fix PVC insulated telephone copper cable 4P for indoor applications confirming to TEC specification G/WIR06/02, unarmoured 0.5mm ATC etc complete all as specified and as directed at site by the Engr-in-charge.
Item No 31 : Supply and fix PVC insulated co-axial cable for indoor applications for TV complete all as specified and as directed at site by the Engr-in-charge.
Item No 32 : Supply and fix RJ 11 modular telephone socket complete all as specified and as directed at site by the Engr-in-charge.
Item No 33 : Supply and fix TV socket, co-axial socket 1 module complete all as specified and as directed at site by the Engr-in-charge.
Item No 34 : Supply and fix rosette junction box complete all as specified and as directed at site by the Engr-in-charge.
Item No 35 : Supply and fix Cast Iron/pressed steel terminal boxes 100x100mm and 60 mm deep for mounting, switches, sockets, fan regulator, etc. with 3mm thick plastic laminated sheet cover. complete all as specified and as directed at site by the Engr-in-charge.
ROAD/ PATH/ CULVERT
Item No 36 : Road stud (Cat Eye) globe with solar system with battery/cell with abs plastic body and glass reflector elements complete all as per manufacturer's specifications.
Item No 37 : Material and labour for painting lines, dashes, arrows, letters etc on roads, pavements and the like exc 10cm width by applying hot applied thermoplastic road marking paint (white/yellow) conforming to BS-3262-1989 inclusive type I reflectorising glass beads as per table 800-3, 800-4 of MORT&H applied in uniform thickness of at least 2.00mm and 10cm wide and spread uniformly with reflectorising glass beads type I & II as per Clause 803.4.3 of MORT&H specifications with a road marking machine as per IRC: 35 ,with traffic diversion arrangements if required, complete as per MORT&H specification clause 803.4, complete all as specified and directed.
HOT WATER APPLIANCES
Item No 38 : Supply, installing & Testing of Water heater(Geyser) storage type of capacity 25 liters, BEE 5 Star rated , 2KW capacity, glass lined coated inner tank, suitably installed with grouting of Nuts, Bolts and washers of suitable size, including 2 KW heating element, cable of suitable size as recommended by manufacturer, with 3 pin plug Top of suitable capacity, etc complete all as specified and as directed at site by the Engr-in-charge. Make: V-Guard Model No Steamer Plus EC or equivalent in the makes detailed in list of makes in Particular Specifications.
Item No 39 : S & F PVC connection for Cold/Hot Water 15mm with CP nuts and bolts and washers of length 300mm complete all as specifed and as directed at site.
AVIATION OBSTRUCTION LIGHT
Item No 40 : Supply and fix solid state electronic type aviation obstruction light fitting 300 Nos LED with cast aluminium poly carbonate red colour, with control switch and connecting & testing complete on top of Buildings all as directed.
Item No 41 : Supply and fix MCB DB SPN 2 way including provision of 01 MCB SP 6 for ON/OFF of light complete all as directed.
EXTERNAL ELECTRIFICATION
Item No 43 : Material and labour for cutting the existing bituminuous road /cement concrete surface of 150 mm thick to the width not exceeding 0.50 metre for laying of GI pipe lines and making good the disturbed area with PCC 1:3:6 Type C-1 using 20 mm graded aggregate including necessary form work complete all as specified and as directed .
Item No 44 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 3.5 core, 240 sqmm cross-sectional area, complete all as specified and as directed.
Item No 45 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 3.5 core, 70 sqmm cross-sectional area, complete all as specified and as directed.
Item No 46 : Supplying & laying XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 3.5 core, 35 sqmm cross-sectional area, complete all as specified and as directed.
Item No 47 : Supplying & laying XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 4 core, 25 sqmm cross-sectional area, complete all as specified and as directed.
Item No 48 : Supplying & laying XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 4 core, 16 sqmm cross-sectional area, for street light complete all as specified and as directed.
Item No 49 : Supplying & laying XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 2 core, 10 sqmm cross-sectional area, for street light complete all as specified and as directed. (For Garden lights)
Item No 50 : Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core stranded conductor 6 sq. mm nominal cross section in service connections complete all as specified and as directed.
Item No 51 : Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core stranded conductor 4 sq. mm nominal cross section in service connections from junction box to street light fitting complete all as specified and as directed.
Item No 52 : S&F LED Street light fittings of 60 Watts LED made up of die cast housing with toughned glass and individual LEDs with secondary optics and IP66 with 4KV in built surge Protection and having efficiency 110 lumen/watt protection including connection with street light feeder, testing complete all as specified and as directed by Engineer-in-Charge.Philips cat Part No : BRP 060 LED 58 CW RMS1 PSU or equivalent specified make given in Particular specification
Item No 53 : S&F Cable junction box of size (205 x225 x 112) mm, IP 66, halogen free and weather proof for outdoor installation of street lights, complete with terminals suitable for cable size 25 sqmm 4 core after dismantling, existing unserviceable street light junction boxes any sizes & type, disconnection of existing cable connection/re-connection of cables etc For street Lights complete including supply & fixing of M.S flat iron clamps of suitable size all as specified and as directed by Engineer-in-Charge. (Make : Hensel Cat No. KF 2525G or equivalent as approved by GE ) (For Street light)
Item No 54 : S&F Timer box of size 35x25x15 CM made out of 2mm thick sheet Powder coated suitable for fixing at Pole including two set of clamps comprising with the following :- i) MCB TP 40 Amps 10 KA ii) Astronomical Time Switch Suitable for 24 hours operation of street light iii) Contactor Three Pole 40 Amps 415 VOLT COIL OPERATING VOLTAGE 230 VOLT( ML 3) complete including internal connection done by using suitable size of copper wire complete all as specified and as directed by Engineer-in-Charge. (Make : Indoasian, Cat Ref : TL040AS0 or equivalent as approved by GE) (For Street lights)
Item No 55 : S&F Integral decorative LED bollard with opal acrylic and IP65 Protection 9 watts including earth and masonary works like suitable size platorm for fixing bollard light with bolts, nuts and PVC junction box all as directed by Engr-in Charge Make: C&S Model: MUCA/9W or equivalent in Philips,Crompton approved by GE. (For Garden lights)
Item No 57 : Supply, installation, commissioning and testing of Main LT Panel board 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 300 Amps capacity Aluminium bus bar for the 3 phase and neutral, out door type of suitable size both side opening along with locking arrangement, rainguard canopy system, with ventilations, fabricated out of steel sections i.e panel body made of 3.15 mm thick CRCA sheet . The panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. The panel shall be mounted on 4 nos supporting Legs of size 60mm x 60 mm and 6 mm thick and 60 cm long fixing with 1:2:4 PCC , Digital multi function meters with necessary CTs complete with cable duct. Panel bottom to ground clearance shall not be less than 45 cm with following accessories complete all as specified and as directed :- a) LED/Neon indicator bulb in RYB Colour - 1 Set. b) Digital Voltmeter 0-500 volts, and Digital Ammeter 0-500 Amps of suitable size - 01 Set c) 3 phase over current and Earth fault relay range (250-400 Apms) with RS 485, Make : L&T, Cat No : 17K726QF4M -01 No d) 4 No Bus bar 300 amps with chamber INCOMING :- a) MCCB 4 Pole, 415 V, Microprocessor release, Adjustable overload type, 160 A with breaking capacity 36 KA OUTGOING a) MCCB 4 Pole, 63 Amp,with Thermal release, ,415 V, 25 KA -03 Nos ( for type IV DB 1,DB2-02 Nos& Type V -01 No b) MCCB 4 Pole, 100 Amp,with Thermal release, ,415 V, 25 KA -02Nos (for DG set-01 and Spare -01 c) MCB TPN 16A-01(for servant qtr) Note :- LT Panel board shall be manufactured by a firm having its sample panel tested and certified by CPRI.
Item No 58 : Supply, installation, commissioning and testing of Essential Panel board 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 200 Amps capacity Aluminium bus bar for the 3 phase and neutral, out door type of suitable size both side opening along with locking arrangement,rainguard canopy system, with ventillations, fabricated (i.e panel body made of) of 3.15 mm thick CRCA sheet . The panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. The panel shall be mounted on 4 nos supporting Legs of size 60mm x 60 mm and 6 mm thick and 60 cm long fixing with 1:2:4 PCC, Digital multifunction meters with necessaty CTs . Panel bottom to ground clearance shall not be less than 45 cm complete with following accessories complete all as specified and as directed :- a) LED/Neon indicator bulb in RYB Colour - 1 Set. b) Digital Voltmeter 0-500 volts, and Digital Ammeter 0-500 Amps of suitable size - 01 Set c) 4 No Bus bar 200 amps with chamber INCOMING :- a) MCCB 4 Pole, 160 Amp,with Thermal release,415 volt 16 KA -01 Nos OUTGOING a) MCCB 4 Pole, 63 Amp,with Thermal release, 415 volt, 16 KA -04 No ( for lifts-01,for pump house-01, for terrace pump-01, Spare -01 No) b) MCCB 4 Pole, 100 Amp,with Thermal release, 415 Volt , 25 KA -02Nos (for DG set-01 and Spare -01 c) MCB TPN, 10 Amp,415 volt, 10 KA -02 No( for Street lights) Note :- LT Panel board shall be manufactured by a firm having its sample panel tested and certified by CPRI.
Item No 60 : M&l for bracket made out of GI pipe 40mm dia medium grade,1.2 mtr long bent to shape with welded MS flat 25 x 4 mm for mounting of fitting & MS flat iron clamps made out of 25mmX 4mm thick FI nuts, bolts complete all as directed by Engr-in-charge.
FIREFIGHTING
Item No 61 : Supply ,connecting, testing and commissioning Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz, 36m head, 900 LPM discharge , pressure of 3.5kg/sqcm at terrace level of the building including the starter panel.
Item No 62 : Supply ,connecting, testing and commissioning automatic air release valve 50 mm dia main inlet made from Gunmetal and fixing on the Top of MS wet riser of 100 mm dia complete alongwith adequate capacity of air vessel all as directed.
Item No 63 : S & F Fire Alarm sounder / sirens electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output Variation of +5 db 500m range.
Item No 66 : Supply ,connecting, testing and commissioning Gun metal fire brigade inlet connection (suction collecting head) consisting of Four Nos 63mm dia instantaneous type male coupling with built in check valves and 100mm dia sluice valve (one number 100mm dia NRV) and 100mm dia flanged outlet complete with all accessories and as directed..
Item No 68 : S & F 4 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and as directed. Make: Kanex, Minimax, Aim-EX, Safeguard, coffco, Variex NOTES: [i] Operating temperature : -30 Degree C to + 55 Degree C [ii] Locking pin and wire seal should be provided to indicate that the extinguisher has not been use. [iii] Every Extinguisher should be supplied with an operating manual.
Item No 69 : S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and as directed. Make: Kanex, Minimax, Aim-EX, Safeguard, coffco, Variex
Item No 70 : S & F of 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and as directed. Make: Kanex, Minimax, Aim-EX, Safeguard, coffco, Variex NOTES: [i] Operating pressure:10 to 15 bars [ii] Operating temperature : -30 Degree C to + 55 Degree C [iii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters [iv] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars for 2.5 minutes and with stand a burst pressure of 55 bar
Item No 71 : S & F of 4.5 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and as directed. Make: Kanex, Minimax, Aim-EX, Safeguard, coffco, Variex NOTES: [i] Operating pressure:10 to 15 bars [ii] Operating temperature : -30 Degree C to + 55 Degree C [iii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters [iv] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars for 2.5 minutes and with stand a burst pressure of 55 bar
Item No 72 : S & F of 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and as directed. Make: Kanex, Minimax, Aim-EX, Safeguard, coffco, Variex
Item No 73 : Supply and fix 9 litres capacity fire extinguisher, ISI marked, confirming to IS:10204, containing 540 ml AFF liquid confirming to IS:4989 Part II and a polyurethane coated CO2 gas catridge, confirming to IS:4947 complete with gunmetal union cap, nylon hose with plastic foam making branch and wall mounting bracket completed all as specified and as directed.
Item No 74 : Supply and install MS rectangular fire bucket stand with canopy to accommodate 4 Nos fire buckets duly painted in red colour (including buckets for sand and water of capacity 9 Litre duly painted in red colour) all as specified.
Item No 75 : Supply, installation, testing and commissioning of UL listed all purpose 10 W ceiling speaker having crush and rust resistant design and fully ABS plastic & ABS grille with tap-setting range upto 4 W, rated (RMS) voltage 70.7 V, sound pressure level at 1 W (1 m & 1 kHz) 80 ± 4 dB, frequency response 125 Hz- 16 kHz, (-10 dB with reference to 1 kHz), complete with transparent FR PVC insulated, twin core copper conductor flexible industrial Speaker cable shielded for interference rejection, unarmoured PVC sheathed 1.1 kV grade in conductor size 2 X 1.0 sqmm including laying, termination and ferruling complete as directed by Engr-in-Charge.
Item No 76 : Supply and fix 100 watt amplifier. Supply, installation, testing and commissioning of UL listed Digital Audio Amplifier capable of accessing and processing one of up to eight audio channels on the DVC audio loop, amplifying the signal and distributing it via eight Class B (speaker line) outputs having two wire digital audio ports to connect to wire DAL (digital audio loop) segments, Firefighter telephone riser supporting 7 active firefighter telephones, 250 W total output at 70 V (RMS) complete as directed by Engr-in-Charge.
Item No 77 : Supply, installation, testing & commissioning of digital Microphone set having 300 mm flexible goose neck, with integrated broadband loudspeaker for monitoring, 12 freely programmable buttons, which can be individually labeled, 13 integrated & 12 freely programmable LED display elements including a combined operations & error display, digital transmission of control signals, audio signals to and from the digital microphone, with option of fiber optic connections complete as directed by Engr-in-Charge.
Item No 78 : Supply , installation and testing commissioning of Control Console complete as directed by Engr-in-Charge.
Item No 79 : Supply, install and commissioning analogue addressable type Fire alarm control panel along with network interface card and with Lead acid battery back up for 08 hours normal operation and 15 minutes alarm operation. (The control panel, battery charger, etc shall be UL listed) complying with BS EN 54 Single loop panel with 99 detectors & 99 modules & upto 200 detectors and modules (per each loop) complete all as specified.
Item No 80 : Supply and install Alarm Repeater panel with display of fire and fault control compatible with the main control panel all as specified and as directed.
DG SET
Item No 81 : Supply, installation, testing and commissioning of silent, Diesel engine driven factory assembled, floor mounted generating set alongwith retrofit emission console device as per CPCB norms, of capacity 62.5 KVA/50 KW at 0.8 power factor or nearest higher size, 3 phase, 4 wire, 50 Hz, 1500 RPM as per IS 10001/10002 to take 10% over load complete with safety control and metering equipments mounted on & including common base frame with acoustic enclosure (canopy), weather proof as per CPCB norms, powder coated all as per manufacturer's instructions manual and all as specified and comprising of the items/ accessories listed hereinafter:- (A) Prime Mover : Directly coupled diesel engine, water cooled suitably de-rated of matching BHP for driving 62.5 KVA capacity, alternator electric start, four stroke confirming to latest IS-10001/10002 for continuous running and capable for taking 10% over load for 01 hour complete with following accessories:- (i) Fly wheel to suit flexible coupling. (ii) Flexible coupling with guards. (iii) Air cleaner with filters. (iv) Lubricating oil filter (v) Heavy duty radiator assembly with fan. (vi) Anti-vibration pad as recommended by manufacturers. (vii) PT pump with electronic gevernor of suitable capacity. (viii) Self starter 12 volts DC. (ix) Necessary arrangement for charging battery. (x) Maintenance free battery 12 volts , duly charged -01 Nos, capacity as supplied by manufacturer and as recommended by manufacturer alongwith flexible copper battery lead and connector. Make :- EXIDE/ AMCO/STANDARD or as approved by GE.
(xi) Battery rack made out of MS angle iron 40 mm x 40 mm x 5 mm & 150 mm height - 01 No. (xii) Standard safety device. (xiii) Daily services fuel tank for full running capacity of DG set for min 12 hours enclosed within the canopy all as per CPCB with lever indicator inlet, fuel outlet drain plug, air vent and locking arrangements etc including fuel pipe connections with connected GI pipe medium grade from fuel tank to DG set and over flow from the DG set to fuel tank complete with gate valve. (xiv) Exhaust system shall be provided with retrofit emission control device as per CPCB norms shall be provided with thermal insulation by using fire retardant/ non igniting foam conforming to BS-4735 to prevent excess heat radiation on the engine and safety of operator. (xv) Mechanical panel having following accessories :- (aa) Digital Lubrication oil temperature guage - 01 No. (ab) Digital Lubrication oil pressure guage - 01 No. (ac) Digital Water temperature guage - 01 No. (ad) Starting switch with key - 01 No. (ae) Battery voltmeter. (af) Indicator lamp etc. (ag) Digital Ammetar DC-01 No. (ah) Digital RPM meter-01 No. (aj) Safety measures : (i) Low lubricant oil pressure trip. (ii) High coolant temp trip. (iii) Engine over speed trip. (iv) Battery charging alternator. (v) Emergency stop pressed.
(B) Alternator : 62.5 KVA at 0.8 power factor, self regulated 3 phase with neutral 415 volts 50 Hz 1500 RPM as per IS : 13364 complete with automatic voltage regulator and foot mounted including making cable connection. The salient feature of alternator are as under :- (i) Voltage regulation under static condition + 1.5%. (ii) Class 'F' insulation. (iii) Permanently lubricating bearing. (iv) Capable to take 10% over load for one hour for every 12 hours. (C) Control AMF Panel : AMF control panel inside the floor mounted acoustic enclosure. Suitable for 62.5 KVA DG set with by pass assessment including all necessary operating and control device (to meet the requirement of above capacity plus 25% over load) such as contactors, MCCBs, CT's, volts meter, Ammeter, indicating lamp, frequency meter, energy meter with protection fuses for panel instrument battery charging ststem with indicator and cut off relays low and high oil pressure, high speed over load and earth fault protection, reverse current protection duly wired copper conductor cable and cable connection with lugs/thimbles complete as recommended by manufacturers and as directed.
(D) Repair tools and 2 years maintenance spare parts as per following:- Repair Tools :- (i) Ring spanner set of 10-01 set. (ii) Screw driver 6”, 8”, 12”, 14” & 24”-02 each (iii) Spanner set of 01-01 set. (iv) Adjustable spanner 12” – 04 Nos. (v) Cutting pliers – 01 No. (vi) Techo meter- 01 No. (vii) Tools kit box (only box) – 01 N (viii) 2 Years Spare :- (a) Fan belt set complete - 01 No (b) Lub oil filter - 01 Set (c) Fuel filter - 01 Set (d) Service manual and spare part catalogue with guarantee card (e ) Shock treatment chart dully framed - 01 Set (f) First Aid Box - 01 set (g) Fire extinguisher foam - 01 set (h) Fire extinguisher (electricity ) - 01 set Make - Engine and Alternator :- Refer to PS.
(E) OEM MADE ACCOUSTIC ENCLOSURE :- Acoustic enclosure (canopy) suitable for 62.5 KVA DG with the following provisions/ specifications :- (i) The enclosure fabricated out of CRCA sheet of 14 SWG suitable to accommodate the DG Set properly. (ii) The sheet metal components are hot dip seven tank pretreated. (iii) It is pure polyester based powder coated (inside as wall as outside). All nuts/bolts/hardwares are zinc coated with salt spray test as per ASTMB- 117. (iv) Battery is accommodated in a tray in the enclosure. (v) The doors are fitted with gasket with high quality EPON gasket to avoid leakage of sound. (vi) Sound proofing of enclosure is done with high quality rock wool/mineral wool conforming to IS 8131 of 50 mm thickness and density of 96 kg/cum. (vii) The wool is further covered with fiber glass cloth and perforated powder coated sheet, insulation level conforming to UL 94 HF1 class flammability. (viii) A special residential silencer is provided within the enclosure to control exhaust noise. (ix) Specially designed alternators are provided to control sound at air entry to the container and exhaust from the container. (x) Adequate ventilation is provided to meet requirement for combustion and heat removal. If required a blower is used to meet total air requirement and air changes. (xi) Temperature of enclosure does not exceed beyond 50 degree C of ambient temperature. (xii) The enclosure is provided with “high enclosure temperature” safety device. (xiii) There should be provision of emergency shutdown from out side the enclosure. (xiv) There should be arrangement for proper illumination inside the canopy. (xv) Noise level should be 75 DB (A) at 1 mtr distance. (xvi) The accoustic enclosure should be as Approved by CPCB.
(F) CPCB NORMS :- DG Set should be as per CPCB-II norms emission limit (g/KWH) standards as follows:- (i) Oxides of Nitrogen + Hydrocarbon (NOx + HC < 4.7) (ii) Carbon Mono Oxide (CO < 3.5) . (iii) Particulate Matter (PM < 0.3) . (v) Smoke limit (Light Absorption Coefficient, per m ) < 0.7
Item No 82 : Design supply, install, testing and commissioning of 08 (544Kg) passengers , speed 1.5 metre/sec, with single speed motor suitable for 415 Volts, 3 phase, 50 Hz AC supply operation, conforming to IS-14665, suitable to serve Four upper floors (G+4) i.e. with 05 stops and 05 landings (Travel/rise 17 M approx) with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescuer device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Guard Room & near Ground floor landing door), complete all as specified and directed. Note :- 1) Contractor should keep the lift functional by repairing/replacing as decided by GE the components during the defects liability periods. 2) .Including all civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following :- :- Make :- OTIS/MITSUBISHI/KONE/THYSSONKRUPP/JOHNSON
(A) TECHNICAL SPECIFICATION (a) Type & capacity : passenger elevator for 08 persons (544 Kg) (b) Type of drive : variable voltage and variable frequency drive with microprocessor based controller ± 5 mm landing accuracy with speed encoder. (c) Speed : 1.5 meter per second (d) Travel : Suitable for passenger travel of 17 meter (approx) (opening on same side). (e) Required well size : As per requirement. (f) Power supply : 415/440 volts, three phase 50Hz AC (should withstand variation of + 5% of Voltage) . (g) Inner size : 1300mm x 1100mm deep (Approx) (k) Car enclosure : Car size shall be in conformity with IS 3534-1976 , body to be stainless steel 16 gauge moonrock finish , SS false ceiling (hairline finish) with stainless steel hand rail 38mm hairline finish and mirror of 4mm thickness of suitable size. (l) Flooring : Polished granite flooring. (k) Electric light : LED light fitting (Minimum 04 Nos). (l) Fan : Pressure air fan 380 mm sweep – 01 No. (m) Car entrance : Automatic, centre opening, sliding doors (n) Clear opening : As per IS14665(Part-I) Standards. (o) Operation door : Automatic operation (p) Control : Simplex full collective with and without attendant. (q) Indicators : Hall position indicators for car & landing. Direction and position indicator with stainless steel fixtures at all floors.
(B) STANDARD FEATURES (i) Anti nuisance car call protection (ii) Automatic car return device (home landing) (iii) Specification plate with complete details (iv) Overloading Device. (v) Nudging (buzzer if door is held open for more than 30 Sec). (vi) Emergency fireman’s service (vii) Audible Car Call button (viii) Emergency Car light unit (ix) High performance contact free infrared curtain door protection (x) Door time protection (xi) Emergency alarm Buttom (xii) Extra door time of lobby & parking (xiii) Door open close button (xiv) Manual rescue operation (xv) Battery operated emergency light (LED ceiling fitting) alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeble arrangement for battery.
(xvi) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. (xvii) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. (xviii) Steel wire rope of adequate size as per relevant IS and as per manufacturer's specifications. (xix) Other standard fixtures and fittings like guide rails, sheaves, counter weights and guards, buffers, gear unit brakes control. (C) ADDITIONAL FEATURES (a) Automatic rescue device during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load.
(D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with 16 – segment digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) (iii) Door open/ door closed on car operating panel. (v) Monochrome LED digital position indicator display. (vi) Over load and floor announcement audio and visual arrangement. (vii) Fireman’s switch at main lobby (viii) Manual rescue operation (ix) Call register indicator in all landings (x) Attendent operation system in car panel
Item No 83 : Design supply, install, testing and commissioning of 884Kg/13 passengers, speed 1.5 metre/sec, with single speed motor suitable for 415 Volts, 3 phase, 50 Hz AC supply operation, conforming to IS-14665, suitable to serve Four upper floors (G+4) i.e. with 05 stops and 05 landings (Travel/rise 17 M approx) with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescuer device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Guard Room & near Ground floor landing door), complete all as specified and directed. Note :- 1) Contractor should keep the lift functional by repairing/replacing as decided by GE the components during the defects liability periods. 2) .Including all civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following :- :- Make :- OTIS/MITSUBISHI/KONE/THYSSONKRUPP/JOHNSON
(A) TECHNICAL SPECIFICATION (a) Type & capacity : 884Kg/13 passengers . (b) Type of drive : variable voltage and variable frequency drive with microprocessor based controller ± 5 mm landing accuracy with speed encoder. (c) Speed : 1.5 meter per second (d) Travel : Suitable for passenger travel of 17 meter (approx) (opening on same side). (e) Required well size : As per requirement. (f) Power supply : 415/440 volts, three phase 50Hz AC (should withstand variation of + 5% of Voltage) . (g) Inner size : 2000mm x 1100mm deep (Approx) (k) Car enclosure : Car size shall be in conformity with IS 3534-1976 , body to be stainless steel 16 gauge moonrock finish , SS false ceiling (hairline finish) with stainless steel hand rail 38mm hairline finish and mirror of 4mm thickness of suitable size. (l) Flooring : Polished granite flooring. (k) Electric light : LED light fitting (Minimum 04 Nos). (l) Fan : Pressure air fan 380 mm sweep – 01 No. (m) Car entrance : Automatic, centre opening, sliding doors (n) Clear opening : As per IS14665(Part-I) Standards. (o) Operation door : Automatic operation (p) Control : Simplex full collective with and without attendant. (q) Indicators : Hall position indicators for car & landing. Direction and position indicator with stainless steel fixtures at all floors.
(B) STANDARD FEATURES (i) Anti nuisance car call protection (ii) Automatic car return device (home landing) (iii) Specification plate with complete details (iv) Overloading Device. (v) Nudging (buzzer if door is held open for more than 30 Sec). (vi) Emergency fireman’s service (vii) Audible Car Call button (viii) Emergency Car light unit (ix) High performance contact free infrared curtain door protection (x) Door time protection (xi) Emergency alarm Buttom (xii) Extra door time of lobby & parking (xiii) Door open close button (xiv) Manual rescue operation (xv) Battery operated emergency light (LED ceiling fitting) alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeble arrangement for battery.
(xvi) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. (xvii) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. (xviii) Steel wire rope of adequate size as per relevant IS and as per manufacturer's specifications. (xix) Other standard fixtures and fittings like guide rails, sheaves, counter weights and guards, buffers, gear unit brakes control. (C) ADDITIONAL FEATURES (a) Automatic rescue device during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load.
(D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with 16 – segment digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) (iii) Door open/ door closed on car operating panel. (v) Monochrome LED digital position indicator display. (vi) Over load and floor announcement audio and visual arrangement. (vii) Fireman’s switch at main lobby (viii) Manual rescue operation (ix) Call register indicator in all landings (x) Attendent operation system in car panel
EXTERNAL WATER SUPPLY
Item No 84 : Cutting the any size/type of pipe line and inserting Tee and other specials as required for PPR pipe tapping from the existing pipe line, complete all as specified and directed.
Item No 85 : Construction of Valve Chamber of size 600 X 600 X 600 mm internal size suitable for Sluice Valve, with PCC 1:3:6, Type C2, using 40mm graded aggregate for foundation, 75 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:4, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 5 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as directed.
EARTHINGS
Item No 86 : Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 25x4mm GI earth Strip [Earth Lead] and GI pipe 32 mm bore, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
Item No 87 : Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
Item No 87A : Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm dia GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC pit with 1:2:4 type B1 concrete and RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
EARTH WORK FILLING
Item No 88 : Supply and filling Moorum/red bajri, good earth (from outside MoD land) and bringing to the site filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering. complete all as specified. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Item No 88A : Supply and fixing 150 mm ID x175 mm OD double wall corrugated polyethylene pipe including fittings as per IS 16098 PS 2013 . SN4
STP (SEWAGE TREATMENT PLANT)
Item No 89 : Design (hydraulically, structurally & aesthetically) engineering, procurement, construction, testing and commissioning of Sewage Treatment Plant based on Moving Bed Bio Reactor Technology (MBBR) with tertiary treatment having capacity of 75 KLD each located at ICGS & CGRA as shown in the site plan. It comprises of Inlet chamber, fine bar screen chamber, oil and grease chamber, Air grid, Sewage pump, Air blower, equalization tank, anoxic chamber , anoxic pump, MBBR Tanks, Lamellar settling tank, sludge pump, Chlorine contact cum feeder tank, chlorine dosing system, feed pumps, multigrade filter, activated carbon filter, sludge drying beds, treated water tank, clear water pumps, cables, pipe, earthing, testing equipment ,foundation for all E/M equipment, pump house associated piping works with required valves, gates, drains, pathways , electrical control panels with interconnecting cables including spare parts required to keep STPs functional till defect liability period of 2 years of operation etc. complete as turnkey job including hydraulic testing with all involved civil, electrical, digital, mechanical works . The detailed specifications for civil, electrical & mechanical components are mentioned in Particular specification for guidance only. The scope of works shall also include Manning & Operation of STP for a period of two years up to Defect liability period .The cost for Manning & operation shall be quoted separately.The maintaince of the plant shall be the responsiblity of the contractor during defect liablity period (DLP) Make: ION EXCHANGE INDIA LTD. THERMAX LTD., M/S OPTIMUS ENVIIROPRO PVT LTD AND ALL OEM APPROVED BY E-IN C BRANCH. Notes1: - (a) Complete scheme shall be designed by the contractor based on Design parameters i.e. Raw sewage characteristics and treated sewage characteristics after tertiary treatment. The scheme shall be prepared by the contractor and vetted by IITs/NITs. /Govt. University for further approval from the accepting officer. The detailed design shall commence only after approval of the scheme. (b) The structural drawings shall be developed based on the final approved scheme duly vetted by IITs/NITs. The final approved scheme and drawings duly signed by the contractor’s authorized representative shall submit to the accepting officer for approval in six A1 hard copies and softcopy (CD).
(c) The items mentioned above are indicative only. Any items required over and above for completion and efficient functioning of the plant are deemed to be included in the rate quoted by the contractor. (d) The treated water shall be tested quartely up to DLPby the contractor from NABL accredited Lab and the test should conform to the parameters of treated water within limits as mentioned in Particular Specification. Nothing extra shall be payable for the same. (e) All the finalized drawings shall form part of the tender and all clauses for design of RCC structural elements mentioned in the tender shall be applicable thereto. (f) Preparation and submission of architectural drawings and structural drawing & design by using design software like STAAD/ETABS with load chart for entire structural components, viz, walls, columns, beams, slabs, staircases, tanks etc., along with structural drawings and complete design folder containing structural analysis and design calculations duly vetted by any IIT/NIT.
(g) For design purpose, expected life of building to be considered as minimum 50 years. The design shall be sound, economical and as per best engineering practices suitable for the region. Design shall be compliant of provisions of all relevant IS codes and statutory rules of Govt of India/concerned state Govt. (h) Design and detailing shall be as per requirements applicable to the Mandapam area in respect of seismic forces as per IS code 1893, wind forces as per IS code 875 part 3, dead loads as per IS code 875 part 1, live loads as per IS code 875 part 2. (i) Structural design of foundation shall be based on a detailed soil investigation report to be supplied to the consultant (Appendix). The structural designer should analyse the soil investigation report completely and merely depending on the recommendation part. If any inconsistent data is found part of the soil investigation report, clarifications shall be obtained from GE (I) Chennai under intimation to E2 (Des) section of HQ CE (CG) Visakhapatnam. (j) Structural design of RCC structure shall be as per IS 456, IS 1893 & IS 13920 and detailing shall be as per IS 456, SP 34 and IS 13920. (k) For detailing and design ‘severe’ environmental exposure conditions and 2 hrs. fire rating shall be considered.(l) Contractor shall consider existing invert levels for design of STP in consultation with GE.
TESTING: Testing and commissioning of STP will include testing of all electro-mechanical equipments, treated effluent parameters for treatment of the sewage, etc starting from collection chamber to outlet of tertiary treatment plant. (i) The plant shall be run continuously for minimum 72 hours. Test will be carried out in the presence of GE and Engineer-in-Charge, Contractor/rep of contractor and Rep of OEM. Contractor shall deploy adequate technical staff to operate the plant continuously for 72 hours and he shall be liable to carry out all the maintenance / rectification required during this period . (ii) The contractor shall afford all facilities and make all necessary arrangements for these tests at his own cost. All arrangements including various instruments required to facilitate testing shall be arranged by contractor. (iii) If the test results are not acceptable, all repairs and replacement and extra work of removal and relaying or refixing shall be carried out by the contractor at his own expense and the STP plant will be retested, until test results indicate compliance with the prescribed requirement. (iv) The installation shall be taken over by MES after the plant has been successfully commissioned and tested . (v) Quarterly test report of the treated efflent will be submiited by the contractor during the period of DLP.TEST EQUIPMENT: The contractor will submit the following test eqipments (minimum) deemed to be included in the contract. pH Meter Digital- 01 Nos TDS Meter Digital Tester-01 Nos Chlorine Testing Kits-03 Nos (vi) any other equipments required for testing shall also be provided by the contractor, no extra cost will be paid on this regard. NOTES2:- (i) Defect liability period of Two year. (Repair / replacement/spares of various plant components, including labour for such work covered under performance Guarantee) (ii) The items given above are indicative only. Any items required over and above items, for complete and efficient functioning of the plant is deemed to be included in the rates quoted by the tenderer. (iv) Rates of Minor civil work for foundation of machinery etc deemed to be included in the work. (v) All works shall be carried out by skilled technicians of relevant trade under supervision of rep of OEM. (vi) The routing of cables/pipes/drains etc , shall have proper protection. The workmanship, finish, general appearance & layout of the plant shall be technically correct and aesthetic; all as directed by Engineer in Charge. (vii) Tenderer’s offered rate shall be deemed to include training and operation for 1 month after completion of the plant.
Item No 90 : DG SETS: Supply,install ,test and commission silent Diesel Engine Driven Outdoor Type Generating set of 25 KVA capacity ,415 Volts, 3 phase, 4 wire engine ,Prime Mover ,1500 RPM ,radiator cooled as per IS-10001/10002 and alternator ,25 KVA/20 KW as per IS-13364 complete with Relay Panel and change over switch gears for automatic starting on Main Failure including necessary cableing for connecting with AMF panel having meter and sound proof canopy as per CPCB norms with the following items :- (i) Diesel Engine – The engine shall be vertical multi cylinder 1500 RPM radiator cooled with water pump assembly battery charging alternator of suitable instrument panel, electronic governor starting battery heavy duty with leads (as recommended by the manufacturer) suitable size and length of exhaust pipe with necessary cladding materials, exhaust coupling inside acoustic enclosure/canopy, silencer and exhaust pipe above canopy all as specified by OEM and all other standard fitting fixtures all as per OEM specification complete as per BS 5514 & suitable BHP for generator. (ii) AC Alternator :- The AC alternator (Generator) shall be designed for an out put of 25 KVA /20 KW, 50Hz Brushless at full load for continuous rating & 10 % for over load for one hour suitable for any power factor of load upto unity conforming to BS-5000 part 99/IS 4722 including self excited and self regulating screen protected, standard panel with all accessories cable terminal box suitable size of glands earth terminal etc complete all as per OEM specifications.
(iii) Fuel (Services) Tank :- The fuel tank shall be built in type and shall include fuel level indicator fuel piping internally with the necessary piping as recommended by manufacturer from tank to engine and for over flow etc, and supplying semi rotary pump hand driven manually operated suitable to pump diesel up to 10 feet height ft complete. (iv) AMF Panel and Control Panel :- AMF panel with relay for Auto Change over switch, readings for Current in Ampre, reading for Voltage in Volts, KWH reading, Hours run reading, Fuel level readings, RPM Meter, Engine oil pressure indicator, Battery voltage reading, Coolant temperature reading etc . (v) Safety Controls:- Panel should have safety cut off for Engine low lube oil pressure, High coolant temperature, Engine over speed, Unbalance load in each phase etc. (vi) Unit rate quoted shall deemed include the Control cable of suitable rating/capacity from DG set to AMF panel, DIESEL OIL, LUB OIL, COOLANT FOR RADIATOR ctc for smooth functioning of DG SET commissioning and testing at site complete testing including cost of filling of fuel in phase test testing, topping of LUB OIL, COOLANT FOR RADIATOR etc required for commissioning and testing of DG set. Inverter 100 W capacity of reputed make and Two lights as recommended by the manufacturer with all accessories with necessary connections and wiring from DG set Battery inside the acoustic enclosure. (vii) Provn of CPCB approved Acoustic enclosure composites type for Generator set. (viii) DG Set should be as per CPCB-II Norms emission limit (g/KWH) standard as followsL:- (a) Oxides of Nitrogen +Hydrocarbon (NOx+HC<4.7 (b) Carbon Monoxide (CO<3.5) (c) Particulate Matter (PM<0.3) (d) Smoke limit (Light absorption) Coefficient m-1<0.7. (ix) insulating mat of size 1 mtr x 2mtr 16mm thick. (x) Operation and Maintenance manual and test certificate for Engine, alternator and acoustic proof enclosure.
Item No 91 : M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width not exceeding 60 cm in depth for passing of HT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed.
Item No 92 : M & L for angle stop valve of size 15mm cast copper alloy chroium plated of high pressure screwed for iron pipe and fixed, complete all as specified and directed .
Item No 93 : S&F 20 Watt LED building Security light fitting 230 V AC out door type die cast aluminium housing with heat resistant glass IP 65/66 environmental friendely, energy efficient not less than BEE 4- star rated with electronic driver including GI bracket made out of suitable dia GI pipe light grade 1.2 mtr. length bend to shape fixed to wall and connecting to ceiling rosewith three core flexible rose 1.5 Sqmm PVC copper conductor, complete all as specified and directed.
Item No 94 : M & L for Cutting the existing pipe line of 50 mm to 100 mm including insertion of T section for PPR Pipeline tapping, complete all as specified and directed by the Engineer in charge.
Item No 95 : 200 mm dia double wall corrugated pipe PVC (SN4) laid in trenches and jointed incl coupler with rubber rings complete all as directed. Make: ASTRAL or eqivalent
M & O FOR STP
Item No 96:Manning of Sewage Treatment Plant of 75 KLD - 1 Nos at CGRA Mandapam by providing one semi skilled operator for One Nos pump houses in two shifts per day during DLP period including operating of chlorine dosing system, operation of valves in each shift of 8 hours each including Sundays and Holidays by providing one operator per shift ,the shift timings are :- Ist shift ( 06:00 Hrs to 14:00 Hrs) IInd Shift (14:00 Hrs to 22:00 Hrs)
(a) During 1st year of DLP
(b) During 2nd year of DLP
Item No 97:Manning of Sewage Treatment Plant of 75 KLD - 1 Nos at ICGS Mandapam by providing one semi skilled operator for One Nos pump houses in two shifts per day during DLP period including operating of chlorine dosing system, operation of valves in each shift of 8 hours each including Sundays and Holidays by providing one operator per shift ,the shift timings are :- Ist shift ( 06:00 Hrs to 14:00 Hrs) IInd Shift (14:00 Hrs to 22:00 Hrs)
(a) During 1st year of DLP
(b) During 2nd year of DLP
Note for item 96 & 97: The scope of work includes : (i) Clearing of vegitation/bushes in and around the installations. (ii) Maintening of log sheets for operation and maintenance done. (iii) Periodically clearing of sludge drying bed.
Item No 98 : Supply only of sodium hypochloride solution (During 2 years maintaince period).
K S MUTHU CONSTRUCTTIONS
G R M CONSTRUCTIONS
DANUSH INTERIORS AND CONTRACTORS
SUNDER BUILDERS
CREATIVE BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid