Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.5 LAccepted-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-Finance OK | |
| 2 | L2₹49.9 L+₹2.4 L (5.01%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹52.7 L+₹5.2 L (11.0%)Accepted-Finance | L3 | Accepted-Finance OK |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
6 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Utility Secunderabad
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIRS/ REPLACEMENT AND MAINTENANCE OF WOODEN ENERGY METER BOXES WORN OUT FUSE LINKS AT VARIOUS LOCATIONS UNDER AGE E/M NO I OF GE (UTILITY) SECUNDERABAD
2023_MES_633628_2
GE(U)/SEC/TOKEN/61 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹92,000
Yes
28 Mar 2024
9 Feb 2024
13 Mar 2024
9 Feb 2024
6 Mar 2024
23 Feb 2024
Amount
Taking down carefully old deteroirated wooden/MS boxes/DB/HRC fuse links including MCB SPN, TPN, SP MCBs of any size and pattern complete with all enclosures including making good to the disturbed surfaces complete all as specifed.
Taking down of existing energy meters of any capacity of 1-ph/3-ph energy meters complete all as directed by engineer in charge .
Refixing of existing single phase/3-ph energy meters of any capacity as directed by Engineer-In-Charge.
S&F Sheet metal board of suitable size made of 2mm thick CRCA sheet front openable door with necessary locking arrangement suitable for acommodating , 01 No of 1 phase/ 3 phase energy meter, MCCB 4 pole 100 to 125 Amps and two nos of SPN Isoator as out going including painting with two coats of synthetic enamel paint over a coat of red oxide primer after taking down old boxes with fuse links and fixing new sheet metal board flush to wall with cement work complete all as specified and directed. [Note : Supply and fixing of MCCB and refixing of energy meters paid separately.]
S&F Sheet metal board of suitable size made of 2mm thick CRCA sheet front openable door with necessary locking arrangement suitable for acommodating , 02 No of 1 phase/ 3 phase energy meter, MCCB 4 pole 63 to 100 Amps and 4 Nos of SPN Isolators including painting with two coats of synthetic enamel paint over a coat of red oxide primer after taking down old boxes with fuse lins sheet metal enclosure flush to wall and match the existing surface including periodica complete all as specified and directed. [Note : Supply and fixing of MCCB and refixing of energy meters paid separately.]
S&F MCCB 4 pole, 100 Amps with fixed thermal magnetic release up to breaking capacity 16 KA frame N2, 415 volts conforming to IS : 13947-2 and IEC : 6047-2 complete all as specified and directed..
S&F MCCB 4 pole, 63 Amps with fixed thermal magnetic release up to breaking capacity 16 KA frame N2, 415 volts conforming to IS : 13947-2 and IEC : 6047-2 complete all as specified and directed..
S&F Isolator 40 Amps Double pole single phase 240 Volts operating capacity complete all as specified and directed..
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down shall be measured for payment.
Supply and Lay reinforced precast concrete cable cover LV, Type I,flat, size 250x150x40 mm complete all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20mm graded aggregate set in cement mortar 1:4 as in coping/pedestals of poles including necessary form work complete and applying two coats of white wash to exposed surface of coping/platform complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded aggregate as in foundation, filling and mass concrete for pole / stay / post etc complete all as specified and directed.
M&L for sub main wiring with two runs of single core 1100 volts grade, FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size, 6.0 sqmm, drawn through and including non-metalic rigid PVC conduit 20 mm dia and conduit accessories including provision of one run of FRLS PVC insulated 6 sqmm multistranded copper earth continuity conductor in concealed wiring including taking down old sub main wiring complete all as speciifed and directed. Note :- 2 runs of 6.0 sqmm cable, 1 run of 6 sqmm cable and 1 run of PVC conduit shall be measured as one unit length.
Supply and lay PVC Insulated , PVC sheathed industrial HV round multicore flexible cable with copper conductor 3 core 1.5 sqmm including PVC conduit 20 mm dia medium grade and necessary bends, fittings and fixtures as required for connection of light fittings.
M&L cutting of road/hard standing upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable/protection pipe line making good the disturbed portion so as to match existing finishing with PCC 1:2:4 type B1/cement mortar in CM (1:2) complete all as specified and directed
Supply & lay Galvanised Iron tubing 50mm bore, light grade in protection of cable at road crossing/hard standing/pole protection fixed with MS clamps of size 40 X 4 mm, nut bolts and washer as per site requirement complete all as specified and directed.
Submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required 2 Runs of 2.5 sqmm + 1 Run of 1.5 sqmm earth wire
All as per set item No 21 above but using 2 runs of 4 sqmm + 1 runs of 2.5 sqmm earth wire
M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised earth lead wire 4 mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- The cost of 7.5m long galvanised earth lead wire 4 mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
GI or Steel wire Earth continuti conductor or main earth lead fixed to wall on batten or ressess or chasess or burries in ground or drawn in conduit /pipe to loop earthing as 4 sq mm
M Shyam Sunder
Sri Balaji Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .