Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹26.0 L+₹4.5 L (21.0%)Rejected-Finance | L2 | Rejected-Finance NOT BEINGI LOWEST. | |
| 3 | Rejected-Technical 00 BAJRANG CHOK MAHOBA MAHOBA UTTAR PRADESH 210427 | MAHOBA | UTTAR PRADESH | 210427 | - | Rejected-Technical Criteria Not fullfill in accordance with NIT Details | |
| 4 | Rejected-Technical | - | Rejected-Technical Criteria Not fullfill in accordance with NIT Details |
Tender Value
₹23.3 L
EMD Value
₹46,560
Closing Date
21 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF)BKT
GE(AF)BKT LUCKNOW
REPAIR/MAINTENANCE OF CENTRAL AND PACKAGE TYPE AC PLANT AND SUMMER COOLING APPLIANCES WITH ALLIED WORKS AT AF STN BKT
2020_MES_349821_2
8414/BKT/E8
Open Tender
Civil Works
Item Rate
270 days
GE(AF)BKT LUCKNOW
7 documents required · 7 mandatory
₹500
GE(AF)BKT LUCKNOW
₹46,560
Yes
4 Sept 2020
4 Jul 2020
23 Jul 2020
4 Jul 2020
21 Jul 2020
9 Jul 2020
60 days
Amount
Material and labour for de-scaling and cleaning of chocked pipe water circulating lines including service valves, condenser (heat Exchanger) to cooling tower, circulating concentrated descaling solution (concentrated hydrochloric acid) mixed with water in suitable proportion till the complete deposits/scale is removed as ordered, circulating through pump, servicing of valves, cooling tower, water spray assembly, cleaning with suitable size of drill rod, wire brush including dismantling and connecting all dismantled components in proper position after servicing/overhauling/greasing etc replacement of packing gasket 3mm thick, nuts, bolts with washer, testing of water line for leakage, complete all as specified and directed by Engineer-in-Charge for 3 x 11TR capacity package plant.
Ditto same as item No 1 here in before but Central AC Plant of capacity 2X 11 TR complete all as specified and directed
Ditto same as item No 1 here in before but Central AC Plant of capacity 3X 37 TR complete all as specified and directed
Ditto same as item No 1 here in before but Central AC Plant of capacity 3X 25 TR complete all as specified and directed
M&L for servicing /maintenance /repair, testing and commission of open type reciprocating compressor 25 ton capacity including dismantling and disconnecting suction and discharge refrigerant lines, other controls and accessories, replacement /renewal of minor items but essentially required for completion of the job e.g gasket kits, cut washers, valve springs, castle nuts, suction rid, discharge rid,Lubricant oil, strainer,loading unloading setting,Shaft seal assembly etc and re-assembling in its position, complete all as specified and directed.
M&L for grinding, facing and polishing of cylinder head including supply only main and big end bearing of size to match with the crank shaft with connecting rod bush, piston lock, piston pin, complete all as specified and directed by Engineer-In-Charge. for compressor 25 Ton capacity.
Supply & fix oil stainer assembly for item no 5 here in before complete testing complete all as specified and aproved by engr-in-charge
M&L for reparing of oil pump including replacement of wornout parts i.e. Neoprene `O` ring, coupling with pin and lock, bushes etc except gears for compressor 25 Ton capacity complete all as specified and directed.
M&L for replacement of compressor oil for 3X25 TR AC Plant complete all as specified and directed.
Disconnecting and taking out existing defective compressor of any description and in any position and supplying and fixing new Refrigeration scroll compressor 5.5 TR capacity, three phase, 415 volt capacity including brazing to suction & discharge line, vacuum testing with and including charging of regrigerant gas (R-22) & testing complete all as specified and directed . (Make- Model ZR72KC-TFD-522 of make Copeland or equivalent make and model of KCL/Emersion/Danfoss
M&L for charging of refrigerant gas (R-22) in AC plants with provision of all T&P as required at site complete all as specified and directed by Engineer-in-Charge.
M&L for charging of refrigerant gas (R407 ) in AC plants with provision of all T&P as required at site complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of V fan belt A-28 Make : Fenner / Hilton/DUNLOP or equivalent complete all as specified and approved by Engineer-in-Charge.
M&L for replacement of V fan belt A-32 Make : Fenner / Hilton/DUNLOP or equivalent complete all as specified and approved by Engineer-in-Charge.
M&L for replacement of V fan belt B-84 Make : Fenner / Hilton/DUNLOP or equivalent complete all as specified and approved by Engineer-in-Charge.
Dismantling and taking out existing unserviceable pressure gauge of any description and in any position and Supplying and fixing Freon gas pressure gauge of range 0 - 150 PSI, 100 mm dia complete all as specified & approved by Engineer-in-Charge. Make : Fibig / ACCEL / WAAREE / WIKA / MAHAVEER
Dismantling and taking out existing unserviceable pressure gauge of any description and in any position and Supplying and fixing Freon gas pressure gauge of range 0 - 300 PSI, 100 mm dia complete all as specified & approved by Engineer-in-Charge. Make : Fibig / ACCEL / WAAREE / WIKA / MAHAVEER
Disconnecting and removing existing unserviceable interconnecting wiring and connections of electric control panels of any description and in any position after through checking and inspections at site and material & labour for repairs of electric control panel & its complete interlocking system with using PVC insulated and unsheathed stranded copper conductor cable, single core,1.5 Sqmm size, 1100 Volts grade cable for making functional controls of the compressor, chilled water pump, condenser water pump, Air handling unit, cooling tower fan, LP/HP/Differential oil, pressure switch, solenoid valve, capacity control valve, thermostat, humidistat, heater, auxiliary contactor, push buttons, indicator, amps meter, volt meter complete as required at site for functioning of central AC plant, DX type / chilled water type, all as specified and directed by Engineer-in-Charge. (Note : (ii) The complete panel shall be checked and tested on full load after necessary repairs and replacement of unserviceable parts. for its smooth functioning and proper interlocking including tripping on single phasing (iii) Disconnecting, Taking down and replacement of defective/unserviceable parts/spares/ accessories with new one & its connection shall be measured and paid for separately under appropriate item of Schedule `A' here-in-after.
M&L for replacement of micro processing device (MPD) suitable for 11 TR package type AC plant 230V 7-20Amps rating and testing complete all as specified & directed. Make- Softhard automation. Model No. - PMNMPD.
M&L for repairs to water pump 5 HP capacity by replacement of bearing, impeller and rewinding of motor with super enamelled copper wire of existing gauge complete installation and testing complete all as specified and directed.
M&L for repairs to water pump 2 HP capacity by replacement of bearing, impeller and rewinding of motor with super enamelled copper wire of existing gauge complete installation and testing complete all as specified and directed
M&L for repairs to water pump 7.5 HP capacity by replacement of bearing, impeller and rewinding of motor with super enamelled copper wire of existing gauge complete installation and testing complete all as specified and directed
M&L for repairs to Compressor motor 25 HP capacity by replacement of bearing, impeller and rewinding of motor with super enamelled copper wire of existing gauge complete installation and testing complete all as specified and directed
M&L for repairs of UNSV Cooling tower motor assembly totally inclosed flange type including weather proof with extended saft specially designed for cooling Tower by replacement of bearing, impeller and rewinding of motor with super enamelled copper wire of existing gauge complete installation and testing complete all as specified and directed
M&L for repairs to AHU blower motor 5 HP capacity by replacement of bearing, impeller and rewinding of motor with super enamelled copper wire of existing gauge including repair of shaft complete installation and testing complete all as specified and directed
Supply and fixing differential oil failure switch type MP-55 complete all as specified and directed by Engineer-in-Charge. (Make : Indofoss / Renco / Pean)
Supply and fixing LP control switch MP-15 complete all as specified and directed by Engineer-in-Charge. (Make : Indofoss / Renco / Pean )
Disconnecting and taking out old unserviceable contactor and Supply, fixing & testing new contactor of MNX 12 type, three pole power contactor with 01 NO + 01 NC auxiliary contacts for AC Circuit with AC coil voltage 220 grade, 50 Hz having current rating (AC3) of 12 Amps, 50 Cycle complete all as specified & approved by Engineer-in-Charge . Make : L&T or equivalent of Siemens / Control & switch gear.
--ditto-- all as per item No 87 here in before type but MNX-18 with auxiliary contacts 1NO + 1NC having current rating (AC3) 18 Amps Make : L&T or equivalent of Siemens / Control & switch gear.
--ditto-- all as per item No 87 here in before type but ML1.5 with auxiliary contacts 2NO + 2NC having current rating (AC3) 25 Amps Make : L&T or equivalent of Siemens / Control & switch gear.
--ditto-- all as per item No 87 here in before type but ML2 with auxiliary contacts 2NO + 2NC having current rating (AC3) 32 Amps Make : L&T or equivalent of Siemens / Control & switch gear.
--ditto-- all as per item No 87 here in before type but ML3 with auxiliary contacts 2NO + 2NC having current rating (AC3) 40 Amps Make : L&T or equivalent of Siemens / Control & switch gear.
M & L for replacement of unserviceable thermal over load relay of various ranges as per existing make and model starting from 9 Amps to 42 Amps complete all as specified & approved by Engineer-in-Charge.Make : L&T / BCH or equivalent.
M & L for replacement of unserviceable single phase preventer, auxiliary volts 415 volts, complete all as specified and approved by Engineer-in-Charge.
M & L for replacement of unserviceable tongle switch complete all as specified & approved by Engineer-in-Charge.
S&F Electronic timer suitable for capacity range 12 Amps to 40 amps for star delta startercomplete all as specified and approved by Engineer-in-Charge. Make : L&T / Havells or equivalent
Disconnecting and taking out existing unserviceable solenoid valve and supply & fix new solenoid valve ¼ “ with strainer 3 way. Cat part No. S 180 with Drier of Make : SPORLON. or equivalent make as approved by the GE complete all as specified & directed.
Disconnecting and taking out of existing unserviceable thermostatic expansion valve (R-22) of any description and in any position and supply and fixing and testing of new expansion valve conforming Make SPORLON ,equivalent complete all as specified and approved by engr-in-charge
Disconnecting & Taking out old existing unserviceable MCCB and supply, fixing & testing MCCB, 160 Amps, 4 Pole, 415 Volts having breaking capacity Icu = ICS 100% = 25KA with adjustable thermal setting alongwith SS enclosure including mounting arrangement on wall or panel complete all as specified & directed. Make :Legrand /L&T/Control & Switch gear
Disconnecting & Taking out old existing unserviceable MCCB and supply, fixing & testing MCCB, 100 Amps, 4 Pole, 415 Volts having breaking capacity Icu = ICS 100% = 25KA with adjustable thermal setting alongwith SS enclosure including mounting arrangement on wall or panel complete all as specified & directed. Make :Legrand /L&T/Control & Switch gear
Disconnecting & Taking out old existing unserviceable MCCB and supply, fixing & testing MCCB, 63 Amps, 4 Pole, 415 Volts having breaking capacity Icu = ICS 100% = 16KA with adjustable thermal setting alongwith SS enclosure including mounting arrangement on wall or panel complete all as specified & directed. Make :Legrand /L&T/Control & Switch gear
Disconnecting & Taking out old existing unserviceable MCB and supply, fixing & testing MCB, 32 Amps, 3 Pole, 415 Volts 50 HZ, 10 KA breaking capacity complete all as directed.Make :Legrand /L&T/Control & Switch gear
Supply, fixing & testing Amp meter 0-40 / 50 / 60 /100 Amps, 96mm x 96mm, digital type complete all as specified & directed . Make : AE/ Rishab/Meco/Enercon.
Dismantling and taking out existing unserviceable Temperature gauge (Thermometer) of any description and in any position and supplying & fixing new temperature gauge (Thermometer) suitable for condensing water circulating line, measuring range 0 - 50 oC complete all as specified & directed. Make : Japsine or superior make as approved by GE
Dismantling and taking out existing unserviceable pressure gauge of any description and in any position and supplying & fixing new water pressure gauge of range 0 – 100 PSI, 100mm dia, complete all as specified & directed. Make : Fiebig / ACCEL/Guru/Jupiter or superior make as approved by GE
Supply and Fixing Push Button Red/Green complete all as specified and approved by Engineer-in-Charge.
Supply and Fixing Lamp holder Red/Green complete all as specified and approved by Engineer-in-Charge.
M&L for Preparation of the existing decorated steel surfaces of existing panels of any description & in any position & applying two coats of synthetic enameled paint of approved shade complete including writing details & information on its panels with paints in the pattern & style to match with the words of existing panel complete all as specified & directed by Engineer-in-Charge.
M&L for Disconnecting, dismantling & Taking out existing old unserviceable temperature thermostat switch of any description & in any position including supply & fixing new differential temperature thermostat switch AC 230 Volts grade having range of 5 0C to 25 0C with sense capillary. complete all as specified and approved by Engineer-in-Charge Make : Renco / Pan / Honey well.
M&L for Taking up or down cast iron butterfly valve of any description and supplying, fixing and testing new butterfly valve of 80 mm bore in existing pipe line after necessary cleaning etc. complete all as specified and directed :-( Make:- Castle/Zoloto/ Sant/Venus as approved by GE )
Taking up or down cast iron butterfly valve of any description and supplying, fixing and testing new butterfly valve of 50 mm bore in existing pipe line after necessary cleaning etc. complete all as specified and directed :-( Make:- Castle/Zoloto/ Sant/Venus as approved by GE )
Taking up or down cast iron butterfly valve of any description and supplying, fixing and testing new butterfly valve of 25 mm bore in existing pipe line after necessary cleaning etc. complete all as specified and directed :-( Make:- Castle/Zoloto/ Sant/Venus as approved by GE )
M&L for replacement of PVC filling blocks of size 600mmx300mmx150mm complete all as specified and directed Make: - MIHIR/SUVIDHA/ AVIRATS
M&L for Disconnecting and taking out existing unserviceable strip heater of any description and in any position and Supply, fixing and connecting strip heater of 2 KW/3 KW, 230 volts fin type complete all as specified and directed Make : Daspas or equivalent make as approved by the GE.
S&F glow sign board of central AC plantsize 3000x800x150 mm weather proof made of MS angle 50x50x6mmwith white acrylic sheet 2 mmthick and writing with arial black font with suitable size not exceeding 150 mm and maximum size 100 mm and provision of 04 nos of tubelight 1x36 watt with electronic ballast and other accessories and grouting on floor/roof with suitable primary and secondary support complete all as specified and directed by Engr-in -charge.
M&L for Preparing old painted steel and metal based surfaces such as Compressor, AHU’s refrigerant water piping base plates, motors, AHU’s cable duct, MS channel, make up water tank, cooling tower, condensors, condensor pipe lines, etc of any shape, size and description, removing oil, dust & rust by using sand paper or any method on all types of surfaces, filling cavities if any and applying one coat spray painting with synthetic enameled paint of approved quality (All as per E-in-C’s colour code) with and including writing E/M & MES Nos, marking arrows / feeders name neatly on each machine complete of AC Plant of size 2 X 11 TR complete all as specified and directed by Engineer-in-Charge
M&L for Preparing old painted steel and metal based surfaces such as Compressor, AHU’s refrigerant water piping base plates, motors, AHU’s cable duct, MS channel, make up water tank, cooling tower, condensors, condensor pipe lines, etc of any shape, size and description, removing oil, dust & rust by using sand paper or any method on all types of surfaces, filling cavities if any and applying one coat spray painting with synthetic enameled paint of approved quality (All as per E-in-C’s colour code) with and including writing E/M & MES Nos, marking arrows / feeders name neatly on each machine complete of AC Plant of size 3 X 25 TR complete all as specified and directed by Engineer-in-Charge
M&L for Preparing old painted steel and metal based surfaces of Package type AC of capacity 3 X 11 TR including Package units, motors, pumps,cable duct, MS channel, make up water tank, cooling tower, condensors, condensor pipe lines, etc of any shape, size and description, removing oil, dust & rust by using sand paper or any method on all types of surfaces, filling cavities if any and applying one coat spray painting with synthetic enameled paint of approved quality (All as per E-in-C’s colour code) with and including writing E/M & MES Nos, marking arrows / feeders name neatly on each machine complete all as specified and directed by Engineer-in-Charge.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of window type Air conditioner 1.5 Ton capacity any make & model and supply and fixing company new compressor of same make as existing for window type air condition 1.5 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed by the Engr-in-Charge
Disconnecting, cutting and taking out unserviceable sealed unit compressor of split type Air conditioner 1.5 Ton capacity any make & model and supply and fixing company new compressor of same make as existing for split type air condition 1.5 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed by the Engr-in-Charge
Disconnecting, cutting and taking out unserviceable sealed unit compressor of split type Air conditioner 2 Ton capacity any make & model and supply and fixing company new compressor of same make as existing for split type air condition 2 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed by the Engr-in-Charge
Disconnecting, cutting and taking out unserviceable sealed unit compressor of water cooler storage type 40 - 80 Ltrs/ 60-120 Ltrs capacity any make & model and supply and fixing compressor of same make for water cooler storage type 40 - 80 Ltrs/ 60-120 Ltrs capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections and water connection, installations of water cooler at site and testing on load complete all as specified and directed by the Engr-in-Charge
Disconnecting, cutting and taking out unserviceable sealed unit compressor of water cooler storage type 120/150 Ltrs capacity any make & model and supply and fixing compressor of same make for water cooler storage type 120/150 Ltrs capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections and water connection, installations of water cooler at site and testing on load complete all as specified and directed by the Engr-in-Charge
Disconnecting, cutting and taking out unserviceable sealed unit compressor of Refrigerator upto 195Ltrs capacity any make & model and supply and fixing company repaired compressor of same make for Refrigerator upto 195 Ltrs capacity soldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load complete all as specified and directed by the Engr-in-Charge
Disconnecting, cutting and taking out unserviceable sealed unit compressor of Refrigerator above 195 Ltrs capacity any make & model and supply and fixing company repaired compressor of same make for Refrigerator above 195 Ltrs capacity soldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load complete all as specified and directed by the Engr-in-Charge
Note for Item No 1 to 7 :- (i) Unit rate include transportation to site of work & back as applicable (ii) Cost of refrigeration gas & oil deemed to be included in the unit rates quoted by the contractor
S&f Indoor blower motor of Split type AC 1.5 Ton capacity any make with supper enameled copper winding fixing and testing on load complete all as specified and directed by Engineer-in-Charge
S&f indoor blower motor of Split type AC 2Ton capacity any make with supper enameled copper winding fixing and testing on load complete all as specified and directed by Engineer-in-Charge
S&f blower motor of Water Cooler any capacity any make with supper enameled copper winding fixing and testing on load complete all as specified and directed by Engineer-in-Charge
Re-winding of blower motor of desert cooler any capacity any make with supper enameled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including replacement GM bushes/bearing, fixing and testing on load complete all as specified and directed by Engineer-in-Charge
Starting capacitor 80-100 mfd for window/Split type room air conditioner 1.5/2 Ton capacity including taking out the old unserviceable capacitor complete all as specified and directed by Engineer-in-Charge Make : Epcos/Havells /Usha/ Tipcon
Starting capacitor 100-120 mfd for window/Split type room air conditioner 1.5 /2 Ton capacity including taking out the old unserviceable capacitor complete all as specified and directed by Engineer-in-Charge Make : Epcos/Havells /Usha/ Tipcon
All as per Item No 13 here-in-before but 4 mfd
All as per Item No 13 here-in-before but 6 mfd
Running capacitor 10 mfd for water cooler including taking out the old unserviceable capacitor complete all as specified and didfrected by Engineer-in-Charge Make : Epcos/Havells /Usha/ Tipcon
All as per Item No 16 here-in-before but 20 mfd
All as per Item No 16 here-in-before but 36 mfd
All as per Item No 16 here-in-before but 45 mfd
All as per Item No 16 here-in-before but 50+6 mfd
All as per Item No 16 here-in-before but 55+6 mfd
Starting relay for 1.5 Ton window type AC including taking out the old unserviceable relay complete all as specified and directed by Engineer-in-Charge Make : Renutrol/indfoss
All as per Item No 22 here-in-before but for split type AC
All as per Item No 22 here-in-before but for water cooler
All as per Item No 22 here-in-before but for Refrigerator
Thermostatic switches for any capacity for window/split type AC including taking out the old unserviceable switches complete all as specified and directed by Engineer-in-Charge Make : Renutrol/Indfoss
Thermostatic switches for any capacity for Water cooler including taking out the old unserviceable switches complete all as specified and directed by Engineer-in-Charge Make : Renutrol/Indfoss
Thermostatic switches for any capacity for Refrigerator including taking out the old unserviceable switches complete all as specified and directed by Engineer-in-Charge Make : Renutrol/Indfoss
MS front bottom panel of water cooler duly spray painted to match with the existing water cooler including dismantling/taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge
Chromium plated drip tray assembly of water cooler complete with elbow including dismantling/taking out the old unserviceable drip tray complete all as specified and directed by Engineer-in-Charge
Hose pipe 20 mm dia synthetic PVC rubber corrugated of standard length for wadter cooler complete with two clamps (worm gear type) one on each side including dismantling the old unserviceable hose pipe complete all as specified and directed by Engineer-in-Charge
20 mm dia PVC pipe cotton bralded for water cooler connection complete all as specified and directed by Engineer-in-Charge
15 mm dia PVC (heavy duty) pipe for desert cooler complete all as specified and directed by Engineer-in-Charge
20 mm dia MS clamp (worm gear type) for PVC pipe including dismantling the old unserviceable clamp complete all as specified and directed by Engineer-in-Charge
Blower motor 230 Volts, AC 50 Hz single phase complete with blower fan for window type room air conditioner 1.5 Ton capacity of existing make and size including taking out the old unserviceable motor complete all as specified and directed by Engineer-in-Charge Make : AUE/Universal/Khatain/Bajaj
All as per Item No 35 above here-in-before but out door unit split type AC
All as per Item No 35 above here-in-before but Water cooler
All as per Item No 35 above here-in-before but Desert cooler 3 speed
Replace/in repair Circuit board PCB of Split Type AC complete for 1.5/2.0 TR Split type A/C and complete testing as per directed
Repair and maintenance of Circuit board PCB complete for 1.5/2.0 TR Split type A/C and complete testing as per directed
S&F Indoor unit of split type AC capacity 1.5 TR including evaporator coil ,blower ,blower motor,controling circuit of AC complete all as specified and directed by Engr-in Charge. Make- LG,Carrier ,Daikin ,Samsung
All as per Item No 41 here-in-before but for Capacity 2.0 TR
Blower fan blade complete for desert cooler all as specified and directed by Engineer-in-Charge Make : AUE/Universal/Khaitan/Bajaj
Cable PVC insulated sheathed 3 core copper conductor size 40/0.0076 mm including taking out the old unservidceable conductor complete all as specified and directed by Engineer-in-Charge
Push cock press push type MS chromium plated suitable for 15 mm bore pipe for water cooler including dismantling the old unserviceable push cock complete all as specified and directed by Engineer-in-Charge
Maintenance, servicing cleaning of window type room air conditioner 1.5 Ton capacity at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switches condensor motor, blower/condensor fan rectification of fault, connecting and testing on load. Replacement of spare or gas shall be measured and paid separely under respective item
Maintenance, servicing cleaning of split type air conditioner 1.5/2 Ton capacity at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switches condensor motor, blower/condensor fan rectification of fault, connecting and testing on load. Replacement of spare or gas shall be measured and paid separely under respective item
Regulating knobs of window type room air conditioner including dismantling the old unserviceable knobs complete all as specified and directed by Engineer-in-Charge
Maintenance, servicing & repair of refrigerator 170/195 ltrs capacity any make model cleaning the various components and replacement i. e Chill tray, Shelves, Freezer door, Door Gasket, Door Lock, Blub Holder & bulb and Food tray complete all as specified and directed by Engineer-in-Charge
Maintenance, servicing & repair of refrigerator 310/345 ltrs capacity any make model cleaning the various components and replacement i. e Chill tray, Shelves, Freezer door, Door Gasket, Door Lock, Blub Holder & bulb and Food tray complete all as specified and directed by Engineer-in-Charge
Defrost timer for domestic refrigerator including dismantling the old unserviceable timer all as sample and directed by Engineer-in-Charge Make : Samsung/Godrej/Whirpool
All as per Item No 50 here-in-before but Bimetal relay
All as per Item No 50 here-in-before but Defrost heater
All as per Item No 50 here-in-before but Fan motor assy alongwith fan blade
All as per Item No 50 here-in-before but over load proection for refrigerator
All as per Item No 50 here-in-before but PTC relay
Condenser line filter for window/split AC complete all as specified and directed by Engineer-in-Charge
Condenser line filter for Refrigerator complete all as specified and directed by Engineer-in-Charge
Condenser line filter for Water cooler complete all as specified and directed by Engineer-in-Charge
Maintenance & servicing of water cooler 40/80 ltrs,60/120 & 120/150 Ltrs at site cleaning the equipment, checking wiring , running and starting capacitor, thermostatic switch condensor motor, blower fan, rectification of fault replacement of spare and charging of gas as on required basis, connecting & testing on load for performance all as directed by Engineer-In-Charge Note : Spare and gas shall be measured and paid separately
Spray painting to water cooler 40/80 Ltrs & 120/150 Ltrs with one coat of synthetic enamel paint (colour as per original shade) including writing of SM No over the body with white/black paint all as per specified and directed by Engineer-in-Charge
Taking out the existing rusted/worn out base plate of water cooler 40/80 ltrs & 120/150 Ltrs capacity by disconnecting the compressor, condenser motor, providing new MS base plate including welding work and straightening of base plate & re-fixing the compressor, condensor & condenser motor making all connection, charging gas and testing on load all as specified and directed by Engineer-in-Charge
Grill of window type room air conditioner 1.5 ton capacity suitable for any make & model as existing at site including dismantling old grill complete all as specified and directed by Engineer-in-Charge
Servicing and painting of desert cooler installed at site, cleaning the equipment with air blower fan and wiping , dry and wet cleaning of body and louver, preparations surface with soft wire brush and painting the cooler with one coat of synthetic enamel paint checking the control wiring, fan & motor, tullu pump and replacement of the following plastic part of tullu pump and cooler body and oiling the pump & motor complete (a) Wiper (b) Plastic impeller of tullu pump with enclosure (c) Distributor
Cutting, disconnecting & taking out the condensing unit of split type room air conditioner 1.5 Ton capacity and providing the new condensing unit of exsting size model in place including welding, brazing etc and tdesting on load all as specified and directed by Engineer-in-Charge
All as per item No 65 here-in-before but evaporator coil
All as per item No 65 here-in-before but water cooler
Spray painting of window type AC 1.5 Ton capacity including preparation of old surfaces and applying one coat of synthetic enamel paint (colour as per original shade ) including writing of SM No over the body with white/black paint all as directed by the Engineer-in-Charge
Replace air filter suitable for window type AC 1.5 Ton capacity all as per sample and directed by Engineer-in-Charge
All as per Item No 69 here-in-before but for split type AC
Supply only Submersible pump for desert cooler (in replacement) for lifting water upto 1.2 meter head. Make : Champian/Crompton Graves/Meghdoot/Usha.
Wood wool pad set suitable for desert cooler heavyy duty including dismantling the old unserviceable wood wool pad set all as directed by Engineer-in-Charge
Re-winding of main transformer of voltage stabilizer capacity 5 KVA with super enameled copper winding wire of suitable gauge including making connection by soldering and testing complefte all as directed by Engineer-in-Charge
All as per Item No 73 here-in-before but 4 KVA
Relay for voltage stabilizer 240 volts all as per sample and required at site including dismantling the old unserviceable relay
Volt meter 0-300 volts fixed as in repair
Amps meter 0-30 Amp fixed in repair
Timer circuit for voltage stabilizer including dismantling the old unserviceable timer circuit all as per sample and required at site complete all as specified and directed by Engineer-in-Charge
Connector porcelain type for voltage stabilizer including dismantling the old unserviceable porcelain complete all as specified and directed by Engineer-in-Charge
Float valve with PVC float ball brass stem & fly nut complete with screwed for iron pipe 15 mm bore fixed in repairs complete all as specified and directed by Engineer-in-Charge
Gun metal gate valve with iron wheel head screwed both ends for iron pipe 15 mm dia fixed in repairs complete all as specified and directed by Engineer-in-Charge Make : Neta/Leader/Bir
15 mm dia PVC connection to water coolers 450 mm long fixed in repair complete all as specified and directed by Engineer-in-Charge
Gi nipple 15 mm dia 150 mm long fixed in repair complete all as specified and directed by Engineer-in-Charge
15 mm bore GI tubing medium grade fixed in repair complete all as specified and directed by Engineer-in-Charge
GI Union 15 mm dia fixed in repairs
GI Socket 15 mm dia fixed in repairs
Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Mettalic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete fixed as in repairs complete all as specified and directed by Engineer-in-Charge Make Havells/MDS/Legrand
Taking down unserviceable split AC and re-fixed to its original position after repairing including welding and brazing of copper pipe complete all as specified and directed by Engineer-in-Charge Note : Filling of gas shall be measured be paid for separately
Supply and fixing of Copper Pipe size 5/8"( with sleeves)including welding brazing of copper pipe
Supply and fixing of Copper Pipe size 1/4"( with sleeves)including welding brazing of copper pipe
Supply and fixing of Copper Pipe size 1/2"( with sleeves)including welding brazing of copper pipe
Supply and fixing of Copper Pipe size 3/8"( with sleeves)including welding brazing of copper pipe
Ditto all as per item No 06 here in before but insulation for cooper tube of size 1/4" or 1/2" or 3/8" or 5/8" dia for cooling unit to condensing unit for split AC complete all as specified and directed by Engr-In-Charge.
Supply and fixing of Blower assembly for split type AC any capacity
Supply and fixing of condenser fan suitable for Window type AC any capacity
Supply and fixing of condenser Fan Suitable for Split Type AC any capacity
Supply and fixing of Top Plug 3 pin 220 Volt 5 Amp Make :- Anchor/Plaza/Havells
Supply and fixing of Top Plug 3 pin 220 Volt 15 Amp Make :- Anchor/Plaza/Havells
S&F Industrial protected socket with cap and chain 3 pin 240 volt 20 Amp Make :-Anchor/Plaza/Havells
S&F Industrial protected plug top 3 pin 240 volt 20 Amp Make :-Anchor/Plaza/Havells
Supply and fix blower for split AC 1.5 Ton capacity for indoor unit
Supply and fix blower for split AC 2 Ton capacity for indoor unit
M&L for repair to remote circuit complete with remote device for 1.5/2 TR window/split type AC and complete testing as per directed
S&F in repair MCB protected socket combination including MCB of capacity 25 amps withsteel sheet/plastic enclosure with plug topAC 230 V complete all as specified and directed
S&F in repair MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.
Cable PVC insulated sheathed 3 core copper conductor size 70/0.0076 mm including taking out the old unservidceable conductor complete all as specified and directed by Engineer-in-Charge
Cable PVC insulated sheathed 3 core copper conductor size 110/0.0076mm including taking out the old unservidceable conductor complete all as specified and directed by Engineer-in-Charge
M&L for charging of refrigerant gas (R-22 /32/ 134 (a) / 410 c ) in split/window type AC after detecting leakage test with CO2 gas with provision of all T&P as required at site complete all as specified and directed by Engineer-in-Charge.
All as per item no. 109 here in before but for water cooler
All as per item no. 109 here in before but for refrigerator
M/s Wadaihra Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .