Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹19.7 L+₹3.7 L (23.4%)Rejected-AOC | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹19.8 L+₹3.8 L (23.8%)Rejected-AOC H NO 28 FIRST FLOOR E BLOCK KARMPURA WEST DELHI 110015 | WEST DELHI | DELHI | 110015 | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | L4₹19.8 L+₹3.8 L (24.1%)Rejected-AOC | L4 | Rejected-AOC NOT BEING L1 | |
| 5 | L5₹22.5 L+₹6.5 L (40.9%)Rejected-AOC | L5 | Rejected-AOC NOT BEING L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
16 Feb 2024, 6:00 pmClosed
GE EM RR HOSPITAL DELHI CANTT- 10
GE EM RR HOSPITAL DELHI CANTT- 10
REPAIR REPLACEMENT OF INTERNAL ELECTRIFICATION SUCH AS WIRING, SUBMAIN, MCBS DBS AT AHRR UNDER GE EM RR HOSPITAL DELHI CANTT- 10
2024_MES_639065_1
GE/H-47/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DELHI CANTT 10
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE EM RR HOSPITAL
₹50,000
Yes
30 Mar 2024
25 Jan 2024
19 Feb 2024
25 Jan 2024
16 Feb 2024
9 Feb 2024
Amount
Taking down copper/aluminium point wiring (light, fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition separately) and making good disturbed surfaces of wall, floor etc. complete all as specified.
M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point/exhaust point controlled by one, one way switch 06 Amps complete all as specified. Note - All accessories likes modular top cover plate/ hylum sheet cover plate with frame, Modular type Metal flush box, screws as applicable will be included in quoted rates.
All as per srl item No. 02 here in before but point wiring for one socket outet point 3 pin 5 amps on the same board.
All as per srl item No. 02 here in before but point wiring for one socket outet point 3 pin 5 amps on the independent board.
All as per srl item no. 02 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 3/5 pin 15 Amp power point on Independent board.
Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in & including PVC surface casing and caping including 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including modular MS sunken box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point/exhaust point controlled by one, one way switch 06 Amps complete all as specified. Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws, as applicable will be included in quoted rates.
All as per srl item No. 06 here in before but point wiring for one socket outet point 3 pin 5 amps on the same board.
All as per srl item No. 06 here in before but point wiring for one socket outet point 3 pin 5 amps on the independent board.
All as per srl item No. 06 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 3/5 pin 15 Amp power point.
Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in existing conduit including 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including modular MS sunken box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point/exhaust point controlled by one, one way switch 06 Amps complete all as specified. Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws, as applicable will be included in quoted rates.
All as per srl item No. 10 here in before but point wiring for one socket outet point 3 pin 5 amps on the same board.
All as per srl item No. 10 here in before but point wiring for one socket outet point 3 pin 5 amps on the independent board.
All as per srl item no. 10 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 3/5 pin 15 Amp power point on Independent board.
Material and labour in replacement of Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including cutting and chasing,and also PVC conduit suitable dia as per SSR part-I with medium grade including 4.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified and directed by Engr-in Charge. Note : 1. The two run of 4.0 Sqmm wire, one run of 4.0 Sqmm wire and 1 run of PVC conduit will be measured as one unit.
All as per srl item no. 14 here-in-before but with 2 run of 6.0 sq mm FRLS copper wire with 6.0 Sqmm FRLS copper cable as earth wire.
All as per srl item no. 14 here-in-before but with 2 run of 10.0 sq mm FRLS copper wire with 10.0 Sqmm FRLS copper cable as earth wire.
All as per srl item no. 14 here-in-before but with 4 run of 6.0 sq mm FRLS copper wire with 6.0 Sqmm FRLS copper cable as earth wire. Note:- 1. The Four run of 6.0 Sqmm wire, one run of 6.0 Sqmm wire and 1 run of PVC conduit will be measured as one unit.
All as per srl item no. 14 here-in-before but with 4 run of 10.0 sq mm FRLS copper wire with 10.0 Sqmm FRLS copper cable as earth wire. Note:- 1. The Four run of 10.0 Sqmm wire, one run of 10.0 Sqmm wire and 1 run of PVC conduit will be measured as one unit.
Supply & fixing in repair Modular switch 6 Amp, 1 way, 1 module size complete all as specified and directed.
Supply and fixing in repair Modular switch 16 Amp, 1 way, 1 module size complete all as specified and directed.
Supply and fixing in repair Modular socket 6 Amp, 3 pin, 2 module size complete all as specified and directed.
Supply and fixing in repair Modular socket 6/16 Amp, 3 pin, 2 module size complete all as specified and directed.
Supply and fixing in repair Modular Fan regulator step type, 100 watts, 1 Module size complete all as specified and directed.
Supply and fixing in repair Modular Bell push switch 6A with indicator lamp, 1 Module size complete all as specified and directed.
Supply and fixing of Ceiling rose, PVC polycarbonate body isolated body, 3 terminal, 240 volts, 5 Amps complete all as specified and directed.
Supply and fixing in replacement of electric bell of DINGDONG type, 240 volts, single pole and making all necessary connections complete all as specified and directed by Engr-in Charge.
Supply and fixing in replacement of MCB protected modular AC/Geyser box 3 module complete with and including 6 pin socket 25 amps, plug top, modular cover plate, mini MCB SP 25 Amp capacity and PVC gang box etc, complete all as specified and directed by Engr-in Charge.
S&F in repair sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete for 12 way.
All as per srl item No. 28 here in before but 8 Way
All as per srl item No. 28 here in before but 4 Way
All as per srl item No. 28 here in before but 415 V 4 Way TPN all as directed.
All as per srl item No. 28 here in before but 415 V 8 Way TPN all as directed.
All as per srl item No. 28 here in before but 415 V 12 Way TPN all as directed.
All as per srl item No. 28 here in before but 415 V 4 Way VTPN all as directed.
All as per srl item No. 28 here in before but 415 V 8 Way VTPN all as directed.
All as per srl item No. 28 here in before but 415 V 12 Way VTPN all as directed.
S&F in repair MCB SPN, AC, 240 volts of 40-63 Amps capacity "B" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete.
S&F in repair MCB, SP, AC, 240 volts of 6 to 32 Amps capacity "B" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fixing in replacement of MCB TPN 63 Amps, 10 kA with over load and short circuit protection complete all as specified.
S&F in repairs MCCB 4 pole thermal magnetic type 125 Amps, 25 kA including all electric connection and testing commissioning all as directed
Refixing of serviceable and good condition MCBs , any types 6 amps to 63 amps received from old DBs complete all as specified and directed by Engr-in Charge.
S&F in replacement LED tube light fitting 20 watt (CW), 4 feet long in polycarbonate batten with high efficient LEDs available in milky diffuser and PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed by Engr-in-Charge.
S&F in replacement tube light fitting 10 watt (CW), 2 feet long in polycarbonate batten with high efficient LEDs available in clear & milky diffuser and PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed by Engr-in-Charge.
S&F in replacement of recessed mounting LED light fitting (flat panel) 2'x2' with high efficeint LEDs and Glare free and opal diffuser of 36 watt (CW) including fixing accessories likes strip clips, wedge brackets etc, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of surface mounting LED light fitting (flat panel) 2'x2' with high efficeint LEDs and Glare free and opal diffuser of 36 watt (CW) including fixing accessories likes strip clips, wedge brackets etc, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement comfort bed light fitting for patient bed for Hospitals in extruded aluminium housing with PMMA diffuser having system Wattage of 31 Watts having three lights and having personalised bidirectional up & down light for pleasant and smoothing light experience including 03 Nos switches for each light complete all as specified.
S&F in repairs Building security light with high efficient high power LED street light 30 watt with lens with pressure die cast aluminium housing and enclosed with toghened glass, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified.
Supply and fix in replacement of service bracket for mounting on wall of the bldg using 32mm bore light grade GI pipe with fixing accessories likes as clamps, fastener, nuts, bolts etc complete all as specified and directed by Engr-in Charge.
S&F in repairs energy efficient wall/ceiling mounted LED bulk head light fitting 10 watt, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified.
Supply and fix in replacement of fresh air fan PVC body single phase, 240 volts, upto 1200 RPM of 200mm sweep, copper winding complete all as specified and directed by Engr-in-Charge.
All as per sl item No. 50 but 250 mm Sweep.
All as per sl item No. 50 but 300 mm Sweep.
Supply and fix in repair Switch socket combination 6 amps, 2-in-1 with PVC box, 240 volts, 50 Hz all as specified and directed.
Supply and fix in repair Switch socket combination 20 A & 10 A amps,shutter type with PVC box, 240 volts, 50 Hz all as specified and directed.
S&F in replacement of recessed mounting LED light fitting (flat panel) 1'X1' with high efficeint LEDs and Glare free and opal diffuser of 18 watt (CW) including fixing accessories likes strip clips etc, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of surface mounting LED light fitting (flat panel) 1'X1' with high efficeint LEDs and Glare free and opal diffuser of 18 watt (CW) including fixing accessories likes strip clips etc, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement recess/surface mounted LED light fitting 18 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips and PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement recess mounted LED light fitting 15 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips and PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement surface mounted LED light fitting 15 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips and PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement recessed mounted LED light fitting 6 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips and PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement recess/surface mounted LED light fitting (flat panel) 1' x 4' in size of 36 watt(CW) with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips, wedge brackets etc, PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 6 sqmm area, complete all as specified and directed by Engr-in-Charge.
S&F in repair Electronic energy meter, current rating 10-40 amps, 240 Volt, AC, single phase, 2 Wire, accuracy Class 1.0, 50 Hz with LCD display incl/ fitted with temper proof meter box, weather proof, transparent, made out of FR polycarbonate, dust proof, good mechanical strength conforming to IS: 14772/2000,IP-65 complete all as specified. Note:- Taking down of old meter is to be done carefully and to be deposited in MES store yard.
Electronic energy meter, current rating 10-60 amps, 440 Volt, AC, three phase, 4 Wire, accuracy Class 1.0, with LCD display incl/ fitted with temper proof meter box, weather proof, transparent, made out of FR polycarbonate, dust proof, good mechanical strength conforming to IS: 14772/2000,IP-65. complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable Geysers of any capacaity/type/make from various locations by disconnecting the electrical connection and Overhauling the geysers for necessary repair work comprising opening, descaling, brushing and cleaning of storage tank and examining of water tightness of storage tank after cleaning and descaling, checking & connecting earth continuity of electric items, adjusting of pressure release valves, checking of dead weight, cleaning of vent hole, including replacements of all defective parts of the geysers after repair, applying one coat of synthetic enemal paint (white colour) after prepration of old surfaces, marks MES Nos & AGE E/M RRH using black colour and testing complete all as specified and directed by Engr-in-Charge. Note- 1. Any parts other than indicated in item shall be measured and paid seperately under respective items here-in-after as supply only, however labour charges for taking down and fixing of these parts (except parts catered as M&L or S&F) are deemed to be included in quoted rates.
Supply only heating element 2 KW capacity ISI Marked suitable for geyser of any type / Make and capacity complete all as specified and directed.
Supply only of thermostat ISI Marked suitable for geyser of any type and capacity including making necessary electric connection and testing the geyser complete all as specified and directed.
Supply only of inner shell of suitable size made of stainless steel, suitable for geyser 25 litres capacity with and including all suitable fixing accessories complete all as specified and directed.
All as per Srl No items No 68 here-in-before but 50 ltrs capacity.
Supply only of outer shell of suitable size made of steel sheet for geyser of any type/Make and 25 litres capacity complete with two coats of synthetic enamel paint over one coat of primer by spray gun with all suitable accessories, complete all as specified and directed.
All as per Srl No items No 70 here-in-before but 50 ltrs capacity.
Supply only of indicator lamp set of Red &Green colour, suitable for geyser of any type / Make and capacity ISI marked including making necessary electric connection complete all as specified and directed.
Supply only appratus plate assembly 6 hole/9 hole complete with inlet / outlet, thermostat pipes with drain plug and screw including clamps for holding the elements, nuts, bolt etc, for geyser of any type/Make and 10 ltrs to 50 litres capacity complete all as specified and directed.
Supply only bottom cover plate (2 valves) with matching colour of geysers of any type and capacity complete all as specified and directed.
Supply only non return valve in position ISI marked made out of cast copper alloy, internally screwed on one end and externally screwed on other end suitable for iron pipe of size 15 mm, suitable for geysers of any type/Make and capacity complete all as specified and directed.
Supply only 15mm bore 450 mm long flexi connection braided pipe of best quality ISI marked suitable heavy duty for cold and hot water and complete connection with geyser including all accessories complete all as specified and directed.
Supply only 15mm bore 600 mm long flexi connection braided pipe of best quality ISI marked suitable heavy duty for cold and hot water and complete connection with geyser including all accessories complete all as specified and directed.
Supply only of new insulating material made of PUF / glass wool of superior quality of 16 Kg / Cum density in geyser of any Type/Make of 25 ltrs to 50 litres capacity complete all as specified and directed.
S&F in repair GI fastner 10 mm dia x 100 mm long duly threaded with GI nut and washer etc for holding geyser (set of 04 Nos) including fixing arrangement by making necessary holes and using cement mortar(1:2) or PCC 1:2:4 and making good the disturbed surface as per existing complete all as specified and directed. (Note: 04 Nos fasteners shall be measured as one job)
Supply only vaccum release valve complete all as specified and directed.
Supply only Pressure release valve complete all as specified and directed.
boon construction company
GE WORLD
yameen enterprises
Vijeta Solutions
PARADISE INFRA POWER COMPANY
ACR ENTERPRISES
Shrikanth Solutions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .