| 1 | L1₹98.3 LAdmitted-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L1 | Admitted-Finance | |
| 2 | L2₹1.1 Cr+₹13.0 L (13.3%)Admitted-Finance WZ 831 NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Admitted-Finance | |
| 3 | L3₹1.2 Cr+₹18.4 L (18.7%)Admitted-Finance N A | NEW DELHI | DELHI | 110001 | L3 | Admitted-Finance | |
| 4 | Rejected-Technical 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | - | Rejected-Technical Due to sister concern is banned for handling further work load. | |
| 5 | Rejected-Technical A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | - | Rejected-Technical Bidder EMD not submitted. |
| Sl No | Description | Qty | Unit | M/S Rohit Enterprises L3 | Tushar engineers L2 | BRIJ MOHAN LAL AND CO. L1 |
|---|---|---|---|---|---|---|
| 1.00 | Conducting Geo-hydrological/Geo-physical ground water investigation survey at old VRC and Yogindar Vihar area, Delhi Cantt ,through Government local bodies like central water commisssion any authorised serveyer or any state/central Ground Water Boards for location of borewells with four alternative locations of various yields. The report from the concerned department shall be submitted to Engineer-in-Charge. Based on the report, the contractor shall give the proposal for appropriate location which shall be approved by the Garrison Engineer.
Note :- All expenses involved for getting done the Geo-hydrological/Geo-physical ground water investigation survey through local body including inspection fees, fee for submission of application and other incidental charges if any, as required by the local bodies at various stages are to be included in the quote rate of the same. | 1 | Each Job | 35,000 ₹35,000 | 48,900 ₹48,900 | 19,000 ₹19,000 Lowest |
| 2.00 | M&L for trial bore of 250 mm dia upto 200 meter depth below ground level in any kind of soil strata including hard stone/boulder including electric logging, MS cap, MS flat iron clamps, reducing socket etc complete all as specified and directed. | 320 | RM | 1,900 ₹6,08,000 | 1,516 ₹4,85,120 | 800 ₹2,56,000 Lowest |
| 3.00 | Development of trial bore by reaming up to 350 mm for 60 RM from ground level excluding casing pipe of 200mm dia and thickness 8mm and pea gravel as required. | 100 | RM | 1,900 ₹1,90,000 Lowest | 4,230 ₹4,23,000 | 1,900 ₹1,90,000 Lowest |
| 4.00 | -Ditto- all as per Ser Item No 3 here-in-before but reaming up to 350 mm from depth exceeding 60 metre to 200 meter excluding casing pipe of 200mm dia and thickness 8mm and pea gravel. | 220 | RM | 1,900 ₹4,18,000 Lowest | 2,677 ₹5,88,940 | 1,900 ₹4,18,000 Lowest |
| 5.00 | M&L for Development of tube well with compressed air and after with 25 % extra capacity pump by pumping muddy water complete all as specified and directed.
Note:- Development with compressed air by means of air compressor of suitable capacity not less than 500 PSI and over pumping using suitable capacity pump until sand free water is obtained. The compressor/pumping set/ equipment for testing as required shall be arranged by the contractor. Vertical test of tube well housing up to reducer position plumb and alignment immediately after lowering the house in pipe and before commencement for gravel packing by tripped and plumb complete. Chemical & bacteriological testing of water sample from approved laboratory to ensure portability of water. No extra payment will be done on this account. | 40 | Per Hr | 3,000 ₹1,20,000 | 2,999 ₹1,19,960 | 2,000 ₹80,000 Lowest |
| 6.00 | Supply & hanging in bore of ERW MS Pipes Heavy grade of 200 mm dia with thickness 8mm with all fittings as required at site confirming to IS-3589 including necessary welding work as required complete all as specified and directed | 150 | RM | 5,500 ₹8,25,000 | 2,830 ₹4,24,500 | 2,700 ₹4,05,000 Lowest |
| 7.00 | Additional cost for slotted pipe of 200 mm dia in lieu of casing pipe of 200 mm dia. | 48 | RM | 1,000 ₹48,000 Lowest | 1,677 ₹80,496 | 1,200 ₹57,600 |
| 8.00 | M&L for Yeild test for the bore well by continuously pumping for 16 hours to determine safe pumping yield. | 2 | Each Job | 5,000 ₹10,000 Lowest | 49,900 ₹99,800 | 32,000 ₹64,000 |
| 9.00 | Supply and fixing of column pipe, made out of GI pipe, heavy grade, 80mm nominal bore, each 3 Mtr length including flange duly welded with web complete all as specified and directed. | 130 | RM | 1,500 ₹1,95,000 | 999 ₹1,29,870 | 700 ₹91,000 Lowest |
| 10.00 | Supply and laying ductile Iron pipe, S/S including specials, Class “K-7” ,100 mm (4”) dia complete all as specified and directed. | 855 | RM | 1,250 ₹10,68,750 | 1,199 ₹10,25,145 Lowest | 1,200 ₹10,26,000 |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
26 Aug 2026, 6:00 pmClosed
HQ CWE (U) Delhi Cantt-110010
HQ CWE (U) Delhi Cantt-110010
PROVN OF WATER SUPPLY TO INTEGRATED TECHNICAL DIRECTORATE BUILDING (ITDB) FOR DRDO AT SHANKAR VIHAR UNDER GE (U) WATER SUPPLY DELHI CANTT-10
2026_MES_780492_1
CWE(U)/D-12/2026-27
Open Tender
Civil Works
Works
270 days
HQ CWE (U) Delhi Cantt-110010
As per tender documents
9 documents required · 9 mandatory
₹1,000
GE (U) Water Supply
₹2.0 L
Yes
5 Oct 2026
24 Jul 2026
2 Sept 2026
24 Jul 2026
26 Aug 2026
14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Conducting Geo-hydrological/Geo-physical ground water investigation survey at old VRC and Yogindar Vihar area, Delhi Cantt ,through Government local bodies like central water commisssion any authorised serveyer or any state/central Ground Water Boards for location of borewells with four alternative locations of various yields. The report from the concerned department shall be submitted to Engineer-in-Charge. Based on the report, the contractor shall give the proposal for appropriate location which shall be approved by the Garrison Engineer.
Note :- All expenses involved for getting done the Geo-hydrological/Geo-physical ground water investigation survey through local body including inspection fees, fee for submission of application and other incidental charges if any, as required by the local bodies at various stages are to be included in the quote rate of the same. | 1 | Each Job | - | - |
| 2 | M&L for trial bore of 250 mm dia upto 200 meter depth below ground level in any kind of soil strata including hard stone/boulder including electric logging, MS cap, MS flat iron clamps, reducing socket etc complete all as specified and directed. | 320 | RM | - | - |
| 3 | Development of trial bore by reaming up to 350 mm for 60 RM from ground level excluding casing pipe of 200mm dia and thickness 8mm and pea gravel as required. | 100 | RM | - | - |
| 4 | -Ditto- all as per Ser Item No 3 here-in-before but reaming up to 350 mm from depth exceeding 60 metre to 200 meter excluding casing pipe of 200mm dia and thickness 8mm and pea gravel. | 220 | RM | - | - |
| 5 | M&L for Development of tube well with compressed air and after with 25 % extra capacity pump by pumping muddy water complete all as specified and directed.
Note:- Development with compressed air by means of air compressor of suitable capacity not less than 500 PSI and over pumping using suitable capacity pump until sand free water is obtained. The compressor/pumping set/ equipment for testing as required shall be arranged by the contractor. Vertical test of tube well housing up to reducer position plumb and alignment immediately after lowering the house in pipe and before commencement for gravel packing by tripped and plumb complete. Chemical & bacteriological testing of water sample from approved laboratory to ensure portability of water. No extra payment will be done on this account. | 40 | Per Hr | - | - |
| 6 | Supply & hanging in bore of ERW MS Pipes Heavy grade of 200 mm dia with thickness 8mm with all fittings as required at site confirming to IS-3589 including necessary welding work as required complete all as specified and directed | 150 | RM | - | - |
| 7 | Additional cost for slotted pipe of 200 mm dia in lieu of casing pipe of 200 mm dia. | 48 | RM | - | - |
| 8 | M&L for Yeild test for the bore well by continuously pumping for 16 hours to determine safe pumping yield. | 2 | Each Job | - | - |
| 9 | Supply and fixing of column pipe, made out of GI pipe, heavy grade, 80mm nominal bore, each 3 Mtr length including flange duly welded with web complete all as specified and directed. | 130 | RM | - | - |
| 10 | Supply and laying ductile Iron pipe, S/S including specials, Class “K-7” ,100 mm (4”) dia complete all as specified and directed. | 855 | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
BOQ_874281.xls
BOQ • 0.66 MB
TPD12.pdf
Tender Documents • 1.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .