Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹10.5 L+₹62,675 (6.38%)Rejected-Finance B 150 GROUND FLOOR BACK SIDE PANDAV NAGAR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance OTHER THAN LOWEST. |
Tender Value
Refer Docs
EMD Value
₹24,500
Closing Date
1 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bihta
GE (AF) Bihta PIN 801103
Provn of POL store for TRU and certain B/R Work in Officer Mess at AFS Darbhanga under GE (AF) Bihta.
2021_MES_465134_1
8168/BHT/DBG/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Darbhanga
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Bihta
₹24,500
Yes
8 Sept 2021
4 Aug 2021
3 Sept 2021
4 Aug 2021
1 Sept 2021
16 Aug 2021
60 days
Amount
Demolition of cement concrete (unreinforced) in ground floors & paving n.exc 15cm thick (below or above GL) complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
Taking down plastering on lathing (other than wire netting) without removing lathing in cement lime or cement mortor (one side measured in case where both side plastered) complete all as specified and directed
Taking up or down steel tubing and connections including cleaning for re fixing bore of pipe 15 mm complete all as specified and directed
Taking up or down steel tubing and connections including cleaning for re fixing bore of pipe 20 mm complete all as specified and directed
Taking up or down steel tubing and connections including cleaning for refixing old steel tubing 25/32 mm bore and refixing in new or old position (Walls, ceiling, floors, etc) complete all as specified and directed
M & L for 50mm thick cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) in sub-floors, sub-bases, floors and paving etc complete all as specified and directed
M&L for 15mm thick screedbed or bedding layer in CM 1:6 on brick work or concrete surfaces for laying of tiles as in floor complete all as specified and directed
M & L for vetrified light shade tiles (1st quality) 10 mm thick (sqaure/rectangular) polished, area of each tile exceedings 0.36 sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
M&L for rendering 10 mm thick on brick wall or concrete surface in CM 1:4 to receive tiles complete all as specified and directed.
M&L for Glazed ceramic coloured tiles (1st quality) as in vertical surfaces 450x350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for brick work with sub class B bricks (old size bricks) straight or curved on plan to any mean radius in half brick thick built in cement mortar 1:6 complete all as specified and directed
M & L for Rendering 15mm thick on other than fair faces of brick masonary or concrete surfaces in cm 1:6 finished fair and even complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or concret surfaces in cm 1:4 finished fair and even complete all as specified and directed.
Prepration of newly plastered surface of walls and applying two coat of cement base paint over a coat of chalk whiting complete all as specified and directed .
M&L for Prepration of newly plastered surface of walls and applying two coat of oil bound distemper over a coat of alkali resistant priming paint complete all as specified and directed
S&F 15mm bore tube medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
All as per serial item no 17 here-in-before above but 20mm bore.
S&F in repair Bib taps, cast copper alloy with crutch or butterfly handle chromium plated fancy type screwed down, screwed for iron pipe 15 mm bore dia complete all as specified and directed.
M&L for PVC (SWR) floor trap, plain dia of outlet 75 mmwith grating including jointing with solvent cement complete all as specified and directed.
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S & F PVC (SWR) 75 mm bore pipes single socketed, in any length with rubber ring joint anf fixing adhessive fixed to walls complete all as specified and directed..
S&F PVC (SWR) 110 mm bore pipe single socketed in any length with rubber ring joints, laid in tranches or in floors or fixed to walls complete all as specified and directed.
S & F PVC (SWR) 110 mm bore bends any radius complete all as specified and directed..
All as per serial item No 24 here-in-before but 75mm bore.
S & F PVC (SWR) 110 mm bore bends provided with access door complete all as specified and directed.
S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
Surface excavation n exc 30cm deep and averaging 15cm and getting out in Soft/ loose soil complete all as specified and directed.
Excavation in trenches for foundation, laying of cable etc n exc 1.50m wide and n exc 1.50m deep and getting out in soft/ loose soil complete all as specified and directed.
M & L for cement concrete type D-2 1:4:8 (using 40mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and directed
M&L for brick work with sub class B bricks (old size bricks) straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for MS TMT bars 8mm dia and over cut to length, bent to shape required, including cranking, bending,spirally for hooping for columns, hooking end and binding with and including mild steel wire (anneal) not less than 0.9mm dia, complete all as specified and directed.
All as per serial item No 32 here-in-before but 5mm dia and over upto and including 10mm dia as in stirrups, spaces and binders.
M & L for plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed aggregate) mixed with water proofing compound @ 3% by wt of cement or as per manufacturers instructions as in DPC course complete all as specified and directed . Note:- WPC shall be measured & paid separately.
Supply only Liquid water proofing compound.
M&L for reinforced cement concrete (Nominal Mix) 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed.
Use and waste of formwork to sides and soffits of beams bressummers, lintels etc for, rough finished surface of concrete complete all as specified and directed.
M&L for reinforced concrete (Nominal mix) type B-1 1:2:4 (using 20 mm graded stone aggregates as in slab supported on columns, beams, walls, landing and in shelves and like complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping), for fair finish surface complete all as specified and directed.
Use and waste of formwork to edges of concrete flats, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide veritical or battered for fair finished surface of concrete complete all as specified and directed
M&L 20mm thick rendering on fair faces of brick wall or concret surfaces in cm 1:4 finished fair and even complete all as specified and directed.
M & L for rendering 15mm thick on other than fair faces of brick wall or concrete surfaces in cm 1:6 finished fair & even complete all as specified and directed.
M & L for prepration of newly plastered surface of walls and applying two coat of cement base paint over a coat of chalk whiting complete all as specified and directed..
M&L for prepration of newly plastered surface of walls and applying two coat of oil bound distemper over a coat of alkali resistant priming paint complete as specified and directed.
Returning, filling in, including spreading, levelling, waterning and well ramming in layers not exceeding 25cm thick complete as specified and directed
Removing excavated material n,exc 50 m and depositing where directed at a level n, exc 1.5m above the starting point complete as specified and directed
M&L for steel work in tubular trusses /posts including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161 -1979 graded SI 240, complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour as directed by Engineer-in-Charge having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour as directed by Engineer-in-Charge having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S&F for MS frame work such as grill, gratings, etc with ends of bars shoulders and/or riveted, or forged into spikes and for portion framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc confirming to Fe 290 Gde E-165 complete all as specified and directed.
M&L for MS window guard bars, plain let in and fixed independently in wooden/steel frames with welded L or T section support for shelves etc., and similar articles conforming to Fe 290 Gde-165 complete as specified and directed
M & L for hard core of broken bricks of gauze n exc 63mm deposited, spread in layers n exc 15cm thick, watered and rammed to a true surface complete as specified and directed
M & L for 150mm thick cement concrete type B-2 1:2:7 (using 40mm graded stone aggregates) as in sub-floor, sub-bases,floors and paving etc complete as specified and directed
Forming contraction (dummy) joints 50mm deep x 10mm wide filled with sealing compound grade 'B'. Complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection and surface, finished even & smooth without using extra cement including necessary form work all as specified and directed. Note:- 10mm wide and 75mm deep joints shall be made at 3 mtr intervel and at each corner and the same shall be filled with using bitumen 85/25 and sand in the ratio 1:3. Cost of this is deemed to be included in the quoted unit rate by the Contractor.
M & L for preparation of new steel surfaces of any description over 10 cm width or girth and applying 2 coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete as specified and directed
M & L for Machine pressed precast concrete interlocking paver block with grey cement and no pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete as specified and directed
Material and labour for point wiring for with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, ISI marked, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, ISI marked, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed . (a) One light or fan point controlled by one way switch
S & F Switch Piano, flish button, single pole one way, 5 Amp,230 Volts complete all as specified and directed. Make:- Havells/Sudhir/Bajaj/Baliga/Surakshia
S & F Switch Piano, flish button, single pole one way, 5 Amp,230 Volts complete all as specified and directed. Make:- Havells/L & T/Legrand/ABB/Cona/SSK
S&F ceiling rose surface bakellite two to three terminals complete all as specified and directed Make:- Havells/L & T/Legrand/ABB/Cona/SSK
S & F sheet metal enclosre for MCB DB SPN 4 way double door 240 Volts with 200 Amps rated bus bars complete all as specified and directed. Make:- Havells/L & T/Legrand/ABB/Cona/SSK
S & F MCB SPN 63 Amp convient to 'C' Curve breaking capacity 10 KA complete in repair. Make:-Havells/Legrand/L&T/Scheinder/Standard
S & F MCB Single pole 240 Volts 6-32 Amp convienent to 'C' Curve breaking capacity 10KA complete. Make:-Havells/Legrand/L&T/Scheinder/Standard
Supply laying & testing cable XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 25 Sq mm 2 core including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. Make:- Nicco/Plaza/Gloster/Havells/polycab/Grandly/RR Kable
M&L for laying in trenches sub-class 'B' bricks (old size) laid flat perpendicular to the direction of cable for protection of cable complete all as specified & directed.
M&L for sand cushioning for cable in trenches filling 8 cm sand before laying of cable and 15 cm after laying cable and punned to provide required cover/cushion to cable all as specifed and directed. Note:- Only punned depth shall be measured for payment.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed by Engineer-in-Charge. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item
S & F LED building security Light fitting complete 70 Watt with high power energy saving pressure die cast aluminium IP 66 roadway luminiarys heat resistant toughened glass with frame better optics for uniform distribution with high power LED as Ligh source with the help of GI pipe(medium grade) and bracket all as specified and as directed. Make - CG Cat Pat No LSTP-70-CDL or equivelent make and model of PHILIPS/Havells/Syska/Bajaj
Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 4.0 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade, ISI marked complete with and including all PVC conduit accessories concealed into wall by cutting chases in wall and making good the disturbed surfaces to match the existing surface complete all as specified & directed. Make:- NICCO/ICL/Polycab/Finolex/Plaza
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed. Make:- Scheinder Havells/Bajaj/Bliga/Suraksha
S&F stepped typed electronic fan regulator flush type on existing phenolic laminated sheet complete all as specified & directed Make:- Havells/CG/Orient/Bajaj
Supply and fixing Ceiling fan of 1200 mm sweep,230V,350-370 RPM,with air delivery of 215 cmm or more with BEE 5 star rated including provn of fan hook made of MS of required size and shape,hanging with the help of down rod upto 04 feet and connecting with provn of 3 core copper cable of size 1.5 sqmm from ceiling rose to fan complete all as directe dwith all aceesories all as specified and directed. Make:- Havells/Bajaj/Orient/CG
PAPPU ROY CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .