Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹37.7 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹37.9 L+₹20,871.50 (0.55%)Rejected-Finance | ₹37.9 L+₹20,871.50 (0.55%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹38.0 L+₹29,428 (0.78%)Rejected-Finance | ₹38.0 L+₹29,428 (0.78%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹40.3 L+₹2.6 L (7.00%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹40.3 L+₹2.6 L (7.00%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹40.8 L+₹3.1 L (8.26%)Rejected-Finance | ₹40.8 L+₹3.1 L (8.26%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹42.9 L
EMD Value
₹85,800
Closing Date
24 Dec 2019, 6:00 pmClosed
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
PROVISION OF GAS STORE WITH FIRE FIGHTING ARRANGEMENT PATHWAY FALSE CEILING PARTITION TILING AND OTHER ALLIED WORKS AT MO PBR UNDER GE HADDO PORT BLAIR
2019_MES_301354_1
8410/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blari
D a i b i
9 documents required · 9 mandatory
₹500
GE Haddo
₹85,800
Yes
24 Jan 2020
27 Nov 2019
26 Dec 2019
27 Nov 2019
24 Dec 2019
10 Dec 2019
27 Nov 2019 - 30 Nov 2019
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation etc., or for shafts, wells, cess pits, manholes, pier holes etc not exc. 10 Sqm on plan and n.exc. 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 Cum and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:4) complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs including weathering, slightly rounded or chamfered angles and throating including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed.
M&L for pre-cast cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in cover slabs of manholes and setting in cement mortar (1:4) complete all as specified and as directed.
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for hardcore using broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base of floors complete all as specified and as directed.
M&L for 75mm thick PCC (1:2:4) type B2 (using 40mm graded stone aggregate) as in floor base complete all as specified and as directed.
M&L for 25mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in floor base complete all as specified and as directed.
M&L for rendering 15mm thick in two coats 5mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement over 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete, surfaces finished even and smooth (without using extra cement) complete all as specified and as directed.
Supply only integral water proofing compound.
M&L for structural steel grade E-250 (Fe-410W Quality A) conforming to IS:2062 as in compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc., complete all as specified and as directed.
M&L for mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde E-250) Quality 'B' complete all as specified and as directed.
M&L for mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc., conforming to Fe-410-W (Gde E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W (Gde-E-250) Quality 'A' complete all as specified and as directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 15 cm but not exceeding 22.50 cm and dia of neck 16 to 20 mm complete all as specified and as directed.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/valley gutters, fixed with self tapping screws complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
S&F aluminum flat iron wind ties of any size and thickness fixed with self tapping screws for fixing roofing sheets including drilling holes complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers.
Supply only aluminium expanded metal fly proof mesh, cut to size and shape required, with 0.45mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
Supply only 6.0 mm thick sheet glass, ordinary quality and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only 12mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side with balancing white lamination complete all as specified and as directed.
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening etc., conforming to Fe-410-W (Gde E-250) Quality 'A' complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of anti-fungal exterior emulsion over a coat of primer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls of any description over 10cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
M&L for anodised aluminium snap grid frame work for false ceiling with size of grid 605mm x 605mm all as specified in SSR Part-I 2009, hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat iron 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including cutting, drilling, jointing etc., 4mm thick E-boards (Classic) fixed or laid/ inserted to aluminium frame work with screws and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
Dismantling floor, hearth or wall tiling in patches not exceeding 3.0 Sqm each (width not exceeding 0.6 m and of any length) including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick (square/ rectangular) of approved shade, area of each tile not exceeding 0.36 Sqm as in floors etc., laid over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick (square/ rectangular) of approved shade, area of each tile exceeding 0.42 Sqm but not exceeding 1.00 Sqm as in floors etc., laid over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Demolition of PCC block masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar
M&L for 16 to 18mm thick granite slab (of approved shade), machine cut, as in floors, vertical surfaces, steps (treads/risers) and the like laid over cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 20mm thick screed bed in CM (1:4) complete all as specified and as directed.
M&L for sand (river sand) filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block, glossy finished, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 grade, made of grey cement and pigments, laid in floors, set and jointed in neat cement slurry and pointed in white/coloured cement to match with colour of tiles complete all as specified and as directed.
Demolition of cement concrete (un reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for mild steel angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for 6mm thick x 150mm wide non-asbestos decorative planks (Shera planks) fixed to steel members with suitable screws/fasteners/nuts, bolts & washers and applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L for stainless steel hollow sections circular/square/rectangular in shape and any size and thickness, grade AISI-316 type (Austenitic anti-corrosive in nature) as in railings/grills/designer work including post top cap, bottom plate, cutting, bending, seamless welding and fixed in any location complete all as specified and as directed.
M&L for aluminium partition, window and door/ventilator with frame and shutters and grill fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed. NOTES: (i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh will be measured and paid separately under relevant items of this BOQ. (ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc. (iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose.
M&L for seamless gypsum board false ceiling 12 mm thick including for any sunk or raised moulding with 25mm long self drilling/tapping screws having Philips head with joining compound and 48 mm wide fibre tape to provide seam less finish and including GI frame work of seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flange of 20mm and 30 mm, web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm c/c / intermediate channel 0.9 mm thick having two equal flanges of 15 mm suspended from soffit at approx 900 mm c/c with GI cleats and steel expansion fasteners with and including ceiling section (not exceeding 1.2 m length) of 0.55 mm thick having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting across the intermediate channel at 457 mm c/c including hangers 6 mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size, 60 mm long & expansion hold fasteners 12.5 mm dia, 40 mm long and finally applying two coats of oil bound distemper with roller finish over a coat of primer complete all as specified and as directed.
M&L for Point wiring flame proof complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, HRFR cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic stove enamelled steel conduit (ISI marked) and conduit accessories suitable for flame proof wiring concealed in walls/ceilings/roofs/steel sections etc., including provision of PVC insulated 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, HRFR cable, 1100 volts grade, multistranded copper conductor green in colour for earth continuity connected to common earth dolly and flame proof switches etc., all as specified and as directed for one light/ fan point controlled by one flame proof switch, SP, 5 Amps. (For Gas store)
S&F switch flame proof, rotary type with cable termination box in LM6, 6A, single pole, 250V complete all as specified and as directed. MAKE: SUDHIR SWITCH GEAR Cat part No. RI/M/1010-2A or equivalent in SHYAAM/BALIGA (For Gas store)
S&F exhaust fan, flame proof, 380mm (15") sweep, 0.25 HP motor, 1440 RPM speed, 2350 CFM, single pole, 250 V fixed at a height of 4.0 m above floor complete all as specified and as directed. MAKE: SUDHIR SWITCH GEAR Cat part No. EF/140 or equivalent in SHYAAM/BALIGA (For Gas store)
S&F light fitting, flame proof, with LED lamp, 4' (120cm) length, single pole, 250 V complete all as specified and as directed. MAKE: SUDHIR SWITCH GEAR Cat part No. FF/OA/1271 or equivalent in SHYAAM/BALIGA (For Gas store)
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE LIGHT/FAN point controlled by one, one way 6 Amps modular switch.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for TWO LIGHT points controlled by one, one way 6 Amps modular switch.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on independent board.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on same board with other switches.
M&L for Point wiring complete with 4.0 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps modular switch on independent board.
S&F modular switch, one way, one module, single pole, 6 Amps complete all as specified and as directed.
S&F modular socket, multipurpose, 2/3 pin combined, 2 module, single pole, 6 Amps complete all as specified and as directed.
S&F modular socket, multipurpose, 2/3 pin, 6/16 Amps combined, 2 module, single pole, complete all as specified and as directed.
S&F modular switch, one way, one module, single pole, 16 Amps complete all as specified and as directed.
S&F MCCB DB, TPN, 4-way, vertical type, double door, 415 Volts with 200 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed.
S&F MCB DB, SPN, 8-way, vertical type, double door, 240 Volts with 200 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed.
S&F MCB DB, SPN, 4-way, vertical type, double door, 240 Volts with 200 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed.
S&F MCCB, 4 pole, 100 Amps, 16KA rupturing capacity, 415 Volts with thermal and magnetic release complete all as specified and as directed.
S&F MCB, TPN, "C" series, 415 volts, 63 Amps, 10 KA rupturing capacity complete all as specified and as directed.
S&F MCB, DP, "C" series, 230 volts, 40 Amps, 10 KA rupturing capacity complete all as specified and as directed.
S&F MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed.
S&F wall mounting type oscillating air circulating fan, 400mm (16") sweep, working on 230 volts, 50 Hz, single phase, AC supply, heavy duty, aluminium alloy blades with double ball bearings, sturdy closed mesh guard protection complete with all accessories including provision of 3 core twisted copper conductor cable of suitable gauge with plug top from socket outlet to connector of fan complete all as specified and as directed. MAKE: HAVELLS, Model: Accelero HS or equivalent in CROMPTON/USHA/ ALMONARD
S&F LED light fitting 600x600mm size, new generation ceiling fitting, high efficiency, PMMA diffuser covers, recess mounted downlighter with system, 50 watts, 230 volts, IP-20 Class 1 with 4100 Lumens colour, temperature 5700K, CRCA, with built-in electronic driver, connector block etc., and all accessories pre-wired, and connecting up with and including twin core twisted flexible copper conductor of suitable size complete all as specified and as directed. MAKE:CROMPTON Cat Part No. LCTLRN-50-FO-CDL or equivalent in HAVELLS/BAJAJ
M&L for Sub main wiring complete with four runs (3P+1N) of 10.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor and two runs of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Four runs of 10.0 Sqm copper conductor, Two runs of 6.0 Sqmm copper conductor and one run of PVC casing and capping shall be measured as one unit length.
M&L for Sub main wiring complete with three runs (1P+1N+1E) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including suitable size of rigid non-metallic PVC conduit ISI marked, medium grade (not less than 25mm dia) and conduit accessories concealed in wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Three runs of copper conductor and one run of conduit shall be measured as one unit length.
S&F LED security light fitting, 1x25 watts, 230 volts, 50Hz Ac supply, with high power and high efficiency long life LEDs with built-in electronic driver, unique peanut lens to ensure uniform distribution completely housed including suitable down rod and fixed on walls including MS clamps (02Nos) made up of 40mmx5mm MS flat, nuts, bolts and washers and provision of 3 core, 1.5 Sqmm copper cable from ceiling rose to connector of fitting complete all as specified and as directed. MAKE:CROMPTON Cat Part No. LSTS-25-CDL-M or its equivalent in HAVELLS/BAJAJ
M&L for mild steel framed brackets fabricated made out of angles or tees for fixing exhaust fan of any sweep with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., weight of each bracket not exceeding 10 kg and conforming to Fe-290 Gde E-165 including fabrication and fixing complete all as specified and as directed.
S&F MCB DB, SPN, 12-way, double door, 240 Volts with 200 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 2.0 core, 16 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
M&L for 50mm outer diameter Double wall corrugated (DWC) HDPE pipes with necessary fittings and fixtures laid in trenches/on poles etc., for cable protection complete all as specified and as directed
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 32x6mm GI earth strip as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel including test point 75mm x 75mm x 25mm - 01 No. all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
M/S VISHAL CONSTRUCTION
NAWAZ CONSTRUCTIONS
Sree Tirumala Enterprises
BN Engineering Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .