Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted amount overall reasonable | |
| 2 | L2₹36.9 L+₹40,741 (1.12%)Rejected-AOC | L2 | Rejected-AOC 2nd lowest hence rejected | |
| 3 | L3₹37.3 L+₹80,155 (2.19%)Rejected-AOC | L3 | Rejected-AOC 3rd lowest hence rejected | |
| 4 | L4₹37.5 L+₹96,811 (2.65%)Rejected-AOC | L4 | Rejected-AOC 4th lowest hence rejected | |
| 5 | L5₹37.7 L+₹1.2 L (3.16%)Rejected-AOC | L5 | Rejected-AOC 5th lowest hence rejected |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
5 Apr 2021, 6:00 pmClosed
Garrison Engineer Belgaum
Garrison Engineer Belgaum Laxmi Tek Camp Belgaum 590009 Karnataka
SPECIAL REPAIRS TO BLDG No. E5 AT HARDING LINES OF JL WING, SPECIAL REPAIRS TO BLDG No. P193 CH DH OF THE MLIRC AND PROVISION OF CERTAIN OTHER WORKS UNDER GE BELGAUM
2021_MES_430816_1
GE/ BEL/ OF 2020-2021
Open Tender
Civil Works
Item Rate
270 days
Belgaum
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Belgaum
₹98,000
Yes
26 Apr 2021
15 Mar 2021
7 Apr 2021
16 Mar 2021
5 Apr 2021
16 Mar 2021
Amount
Demolition of plain cement concrete in ground floors and pavings n. exc. 15cm thick, below or above GL all as specified and directed.
Demolition of plain cement concrete of any description and size and in any position not otherwise specifically provided for all as specified and directed.
Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) n exc 15cm thick unreinforced below or above GL all as specified and directed.
Dismantling timber scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section all as specified and directed.
Dismantling timber scantlings 40 sq.cm and over in section, in any position, in un-framed work all as specified and directed.
Dismantling boarding of any description fixed in any position with nails all as specified and directed.
Taking down chowkhat with shutters (without taking off shutters from the frame) area n exc 1.5 Sqm each all as specified and directed.
Taking down chowkhat with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n exc 4 Sqm each all as specified and directed.
Taking down shutters of any description n exc 1sqm each all as specified and directed.
Dismantling wrought iron or mild steel work of any description and in any position all as specified and directed.
Dismantling of single layer Mangalore pattern or similar tile in roofing all as specified and directed.
Dismantling of plain or corrugated steel sheets of any gauge and thickness, in roof coverings, valleys, gutters, etc. all as specified and as directed.
Dismantling wall or ceiling boards or insulation boards/ slabs of any thickness including cover fillets all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing, rubbish off the premises all as specified and directed.
Taking down cement plaster on brick or stone wall or ceiling concrete etc. including racking out joints hacking for key scrubbing down with water etc., all as specified and directed.
Taking up or down 15mm steel tubing and connections including cleaning for refixing or removal to store all as specified and directed.
Surface excavation n. exc. 30 cm deep and averaging 15cm deep and getting out in hard/ dense soil all as specified and directed.
Excavation in trenches n. exc. 1.5 m wide and n. exc. 1.5 m depth for foundation, etc. and getting out in soft/ loose soil all as specified and directed.
Excavation in post holes n.exc 0.5 cum in hard/ dense soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm watering and removing surplus soil to a distance n.exc 50 m and making good surface all as specified
Returning filling in with approved excavated soil including spreading levelling, watering and well ramming in layers n. exc. 25 cm thick all as specified and directed.
Removing excavated soil n.exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point in soil all as specified and directed.
M&L for hard core with broken stone or boulders of gauge n.exc 63mm, deposited, spread ,levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces all as specified and directed.
M&L for plain cement concrete type D2 1:4:8 using 40mm graded stone aggregate as in foundation and mass concrete all as specified and directed.
M&L for pre-cast cement concrete solid block masonry, exc 10 cm width, blocks cast in PCC 1:3:6, type C0, using 12.5 mm graded stone aggregate and setting in CM 1:6 including demolition of existing masonry of any description and making good disturbed surfaces all as specified and directed.
M&L plain cement concrete 1:2:4, type B1, using 20mm graded stone aggregate as in surface channels and drains all as specified and directed
M&L for extra for forming fair finished drain or channel of 30cm inner girth in cement concrete using extra cement including forms moulds mitred / stopped end etc. all as specified and directed.
M&L plain cement concrete 1:3:6, type C1, using 20mm graded stone aggregate as in coping, bed blocks, eves filling between wall and tile/ sheet roofing including necessary form work all as specified and directed
M&L for pre-cast plain cement concrete 1:2:4, type B1, using 20mm graded stone aggregate as in kerbs provided on edges of pathways including all necessary forms and moulds with plain fair faces and chamfered edges all as specified and directed
Supply only approved integral water proofing compound all as specified and as directed.
Cutting chases for concealed water tubing and making good in CM 1:3 cutting not exceeding cm girth in stone wall as specified and directed.
M&L for 2nd class hard wood in scantling, clean sawn fixed in unframed work all as specified and directed.
Fixing only serviceable timber scantling of any description obtained from dismantling in un-framed work all as specified and directed.
M&L for 2nd class hard wood plain fillets, square, rectangular or triangular in section, wrought, secured with nails or beads; sectional area exc 13 and n.exc 25 Sq.cm all as specified and directed.
Fixing only serviceable timber fillets, square, rectangular or triangular in section, secured with nails or beads; sectional area exc 13 and n.exc 25 Sq.cm all as specified and directed.
M&L for 2nd class hard wood chowkhat or frames, plain, solid, wrought, framed and rebated on the solid rounded or chamfered, put together with glue pinned at joints, fixed in position all as specified and directed.
M&L for 35 mm thick second class hard wood, Plain framed, panelled shutter (two panel) with lock rail and panel of 12mm thick plywood BWR 7 ply with commercial veneers on both faces with size of rails and stiles sizes of members of shutters as specified in SSR Part I, Section 8. Clause 8.24 (a) and fitted to chowkats all as specified and as directed.
M&L for 35mm thick 2nd class hard wood glazed/ gauged shutters, open rebated and prepared to receive glass, gauze, etc. (divided into square with plain, chamfered or rounded, mitred and rebated sash bars any numbers), edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (a) and fitted to chowkats all as specified and as directed.
M&L for aluminium sliding windows (Triple track), fabricated to required size with standard aluminium anodised sections, with bottom track of size 92 x 31.75 x 1.6mm, side and top frame of size 92 x 31.75 x 1.4mm, top and bottom shutter rail of size 39x17x1.4mm, outer style of size 39 x 17 x 1.4mm, interlock style of size 39 x 27 x 1.4mm, including provision of 4mm sheet glass ordinary quality for panels including provision of all hardware fittings such as handles, locking arrangements, rubber gaskets, rollers, spring catchers etc. complete all as specified and directed.
M&L for aluminium sliding windows (Triple track), fabricated to required size with standard aluminium anodised sections, with bottom track of size 92 x 31.75 x 1.6mm, side and top frame of size 92 x 31.75 x 1.4mm, top and bottom shutter rail of size 39x17x1.4mm, outer style of size 39 x 17 x 1.4mm, interlock style of size 39 x 27 x 1.4mm, including provision of 5mm sheet glass ordinary quality and stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm for panels including provision of all hardware fittings such as handles, locking arrangements, rubber gaskets, rollers, spring catchers etc. complete all as specified and directed. Note: Each window shall be provided with 2 glazed shutter & one wire mesh shutter
M&L for aluminium frame work as in doors, partitions, windows and ventilators using powder coated aluminium sections including provision of glazing clips, hinges, handles, etc including taking down existing aluminium joineries of any description all as specified and as directed. Notes: (i) All the aluminium sections provided under this item shall be measured and converted into weight for payment with the designated unit weight mentioned in the manufacturer's catalogue for the corresponding aluminium sections/ fittings. (ii) The rate quoted deemed to include necessary grouting/ embedding of the aluminium frames/ supports into floors/ walls and making good the disturbed surfaces to match with the existing surfaces and provision of necessary gaskets. (iii) Particle board/ glass panels/ wire mesh shall be measured and paid separately.
M&L for small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles exc 200 cucm nut n exc 500 cucm all as specified and as directed.
S&F MS butt hinges 100mm in size, medium weight, cold rolled all as specified and directed.
S&F aluminium anodised barrel tower bolt 150mm size all as specified and directed.
S&F 150 mm long extruded section aluminium alloy anodised handles fabricated type all as specified and directed.
S&F 300mm long aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clip of sheet cast or extruded section and fixing bolts plate type with bright bolt not less than 12mm dia all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40mm fixed in panel of joinery with stainless steel wire staples all as specified and directed.
S&F rolled mild steel angle sections as in purlins, distance pieces, cleats and similar works conforming to Fe-410-W Gde-E-250 quality-A all as specified and as directed.
S&F mild steel works in tubular trusses, rafters, purlins, etc. including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 all as specified and as directed.
M&L for mild steel flats as in wind ties for roof including securing bolts and necessary drilling, conforming to Fe-290 Gde E-165 all as specified and as directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, conforming to Fe-410-W Gde E-250, quality A, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging, fastening and fixing complete all as specified and as directed.
S&F mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe-290 Gde- E-165 all as specified and as directed.
M&L for pre-painted galvalume coated high tensile corrugated/ trapezoidal profile steel sheets, AZ-70 coating mass, 550 Mpa yield strength, 0.45mm thick (TCT), as in roofing/ cladding fixed with self drilling fasteners as per manufacturers instructions all as specified and as directed. Note: Measurement shall be taken flat as fixed without any allowance for laps, etc.
M&L for pre-painted galvalume coated high tensile plain profile steel sheets, AZ-70 coating mass, 550 Mpa yield strength, 0.45mm thick (TCT), as in ridges, valleys, hips, claddings, etc. fixed with self drilling fasteners as per manufacturers instructions all as specified and as directed. Note: Measurement shall be taken flat as fixed without any allowance for laps, etc.
M&L for 3mm thick Aluminium Composite Panel comprising of a core containing not less than 70% non combustible mineral filling sandwiched between two skins of 0.5mm thick aluminium alloy PERALUMAN-100 (AlMg1-NS41) complete with all necessary sub-structures, anchors, hardware and fittings to provide a total installation, fixed to existing wooden/ steel members all as per manufacturers instructions, fixed in repairs, all as specified and as directed. Note: Measurement shall be taken flat as fixed without any allowance for laps, etc. Make: Alstrong/ Aludecor/ Alucobond/ Eurobond
S&F 4mm thick High Pressure Steam Cured (HPSC) non asbestos fibre cement building board in false ceiling with aluminium anodized snap grids of 60x60cm with Tee section 35x25x1.25mm, angle section 25x25x1.25mm thick including 2mm dia GI hanging wire including all hanger fittings etc and applying three coats of white wash on ceiling all as specified and directed.
M&L for 75mm thick plain cement concrete 1:4:8 type D2 using 40mm graded aggregate as in sub base/ levelling course for flooring all as specified and directed.
M&L for 50mm thick plain cement concrete 1:4:8 type D2 using 40mm graded aggregate as in sub base/ levelling course for flooring all as specified and directed.
M&L for 100mm thick plain cement concrete 1:2:4 type B1 using 20mm graded aggregate as in flooring, finished even and smooth with using extra cement all as specified and directed.
M&L for coloured matt finished ceramic tiles, edge cut, 7 to 8mm thick area of each tile exc 0.18 Sqm but not exc 0.38 Sqm, in floors set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigments to match the shade of the tile laid over and including 15mm thick screed bed in cement mortar 1:4 all as specified and directed.
M&L for coloured matt finished ceramic tiles, edge cut, 7 to 8mm thick cut to size required on vertical surfaces such as skirting, dados etc. to match with flooring, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with surfaces including 10mm thick backing coat in CM 1:4 all as specified and directed.
M&L for coloured glazed ceramic tiles 300mm x 450mm x 7 to 8mm thick on vertical surfaces such as skirting, dados etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with surfaces including 10mm thick backing coat in CM 1:4 all as specified and directed.
M&L for machine cut granite slab, premium quality, any colour, 18 to 20mm thick, set and jointed with neat cement slurry laid over and including 15mm thick screed bed in cement mortar 1:4 and pointed in grey cement (1:2) mixed with colouring pigments to match with the shade of slab, as in floors, platforms, steps, cills, etc. including rubbing and polishing and dismantling of existing unserviceable stone slabs along with cement mortar bedding (but not backing) and removing rubbish of the premises complete all as specified and directed.
M&L for chequered cement concrete tiles 25cm x 25cm x 25mm thick, machine pressed, set, jointed and pointed in neat cement slurry, as in pathways, pavings, etc., laid over and including 15mm thick screed bed in cement mortar 1:6 all as specified and directed.
M&L for coloured, rubber coated, designer cement concrete tiles 25cm x 25cm x 25mm thick, machine pressed, set, jointed and pointed in neat cement slurry, as in pathways, pavings, etc., laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for grinding and polishing the existing old Kota stone flooring/ skirting with necessary white cement, marble powder, etc. complete all as specified and directed.
M&L for 55-60mm thick machine pressed precast concrete interlocking coloured paver blocks, M-35 grade, any shape and size with glossy finish on top confirming to IS 15658-2006 all as specified and directed.
M&L for crushed stone sand (M-sand/ Robo sand/ I-sand) as in cushioning for interlocking paver blocks including watering and consolidating complete all as specified and as directed.
M&L for plain cement concrete 1:3:6, type C2, (Using 40 mm graded stone aggregate), 75mm thick as in plinth protection, finishing the surface fair and even, in panels & filling joints with mortar, etc. all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or PCC block masonry or concrete surfaces finished even and smooth without using extra cement complete all as directed.
M&L for rendering 10mm thick in cement mortar 1:6 on other than fair faces of brick work or stone masonry surfaces finished even and smooth without using extra cement complete all as directed.
M&L for rendering 5mm thick in cement mortar 1: 4 mixed with water proofing compound over 10mm thick backing coat in cement mortar 1:4 on fair faces of brick work or PCC block masonry or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
M&L for rendering 5mm thick in cement mortar 1: 4 mixed with water proofing compound over 10mm thick backing coat in cement mortar 1:6 on stone masonry surfaces or other than fair faces of brick work, finished even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
M & L for 5mm thick sheet glass ordinary quality and glazing to aluminium joineries in square n. exc 0.5 sqm in each pane all as specified and directed.
M&L for one coat of oil bound distemper (Acrylic distemper washable), any colour, on old distempered walls, pillasters, cornices, etc., including necessary preparation of surfaces by washing, rubbing down and stopping all as specified and as directed.
M&L for two coats of oil bound distemper (Acrylic distemper washable), any colour, over a coat of primer over 1mm thick layer of wall care putty, on newly plastered walls, pilasters, cornices, etc., including necessary preparation of surfaces all as specified and as directed.
M&L for two coats of oil bound distemper (Acrylic distemper washable), any colour over a coat of primer over 1mm thick layer of wall care putty on walls, pilasters, cornices, etc., including complete removal of existing treatment and necessary preparation of surfaces all as specified and as directed.
M&L for two coats of cement based paint, any colour, on newly plastered surfaces of walls, pilasters, cornices, etc., including necessary preparation of surfaces all as specified and directed.
M&L for two coats of weather proof exterior emulsion paint over a coat of primer on newly plastered surfaces of walls, pillasters, roof projections, facias, drops, chajjas, etc., including complete removal of existing treatment and necessary preparation of surfaces all as specified and as directed.
M&L for preparing surface of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote oil all as specified and directed.
M&L for one coat of synthetic enamel paint on old painted wooden surfaces of any description over 10cm width or girth including necessary preparation of surfaces all as specified and as directed.
M&L for preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for preparation of new steel surfaces of any description n exc 10 cm width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
S&F 15mm bore galvanized iron tubes, medium grade, with all fittings, fixed complete to walls, ceilings or laid in floors all as specified and directed.
S&F in repairs concussive push button taps of cast copper alloy, screwed for iron pipe and fixed all as specified and as directed.
S&F in repairs 16 gauge thick stainless steel sink, long type, overall size not less than 1750mm long x 370mm wide x 300mm deep with 450mm high splash plate, bowl size not less than 1650mmx350mm at top and 1600mmx230mm at bottom, with 4 sets of plugs, washers and waste pipes & fittings, connecting union to pipe including fixing of the Sink to wall with suitable stainless steel bolts and nuts all as specified and as directed.
S&F in repairs vitreous China soap dish, white, approximate size 160x 160x90mm, any type, fixed to plugs with chromium plated brass screws all as specified and as directed.
S&F in repairs fancy type towel rod, brass CP, 600mm long, fixed to wall with plugs and chromium plated screws all as specified and as directed. Make: CAT No. CAN-CHR- 1111N of JAQUAR or equivalent model in JOHNSON/ ESS ESS/ CERA
S&F in repairs 75mm bore UPVC (SWR) pipes single socketed in any length with rubber ring joints/ solvent cement, fixed to walls/ laid in floors/ laid in trenches all as specified and directed.
S&F in repairs 110mm bore UPVC (SWR) pipes single socketed in any length with rubber ring joints/ solvent cement, fixed to walls/ laid in floors/ laid in trenches all as specified and directed.
S&F in 75mm bore PVC (SWR) bends any radius all as specified and directed.
S&F in 110mm bore PVC (SWR) bends any radius all as specified and directed.
S&F 110mm bore PVC (SWR) branch piece, single Y, equal or unequal with access door all as specified and directed.
S&F PVC (SWR) floor trap with stainless steel grating including jointing with solvent cement 75mm dia outlet all as specified and directed.
S&F for PVC (SWR) gully trap 125/110mm, setting & jointing with solvent cement all as specified and as directed
Taking down carefully existing point wiring of light/ fan/ bell/ 5 Amps socket/ 15 Amps socket/ 2 way light point, etc. complete of any description including fittings and fixtures such as switches, sockets, ceiling roses, pendants, holders, regulators, call bells, light fittings, etc. and making good the disturbed surfaces of walls, floors, etc. all as specified and directed.
M&L for Point wiring complete with 1.5 Sq mm single core PVC insulated FRLS unsheathed 1100 volt grade copper conductor multi-stranded cables drawn through and including ISI marked PVC casing capping of suitable size and all necessary fittings and provision of one run of PVC insulated FRLS unsheathed 1100 volt grade copper conductor multi-stranded single core cable of size 1.5 sqmm and connected to common earth dolly including 2nd class HW board fixed on wall with sunmica top for mounting switches/ sockets etc. for one light point controlled by one switch 1 way complete all as specified and directed.
All as described in item No. 98 but for one fan point controlled by one switch and regulator.
All as described in item No. 98 but for one 05 Amps socket outlet on independent board.
All as described in item No. 98 but for one 05 Amps socket outlet on the same board with other switches.
All as described in item No. 98 but wiring with 2.5 Sqmm single core PVC insulated FRLS unsheathed 1100 volt grade multi-stranded copper conductor cable and with one run of single core PVC insulated FRLS unsheathed 1100 volt grade multi-stranded copper conductor cable of size 2.5 Sqmm for earth continuity conductor and connecting to common earth dolly, complete for one 15 Amps power socket point on independent board all as specified and directed.
M&L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS unsheathed 1100 volt grade copper conductor multi-stranded cables drawn through and including ISI marked PVC casing capping/ PVC conduits of suitable size and all necessary fittings and provision of one run of PVC insulated FRLS unsheathed 1100 volt grade copper conductor multi-stranded single core cable of size 1.5 sqmm and connected to common earth dolly including 1/2 module GI flush mounted box with modular cover plate & frames for mounting switches/ sockets etc. for one light point controlled by one modular switch 1 way complete all as specified and directed.
All as described in item No. 103 but for one ceiling fan point controlled by one switch and regulator.
All as described in item No. 103 but for one exhaust fan point controlled by one switch
All as described in item No. 103 but for one 06 Amps socket outlet on independent board.
All as described in item No. 103 but for one 06 Amps socket outlet on the same board with other switches.
All as described in item No. 103 but wiring with 2.5 Sqmm single core PVC insulated FRLS unsheathed 1100 volt grade multi-stranded copper conductor cable and with one run of single core PVC insulated FRLS unsheathed 1100 volt grade multi-stranded copper conductor cable of size 2.5 Sqmm for earth continuity conductor and connecting to common earth dolly, complete for one 16 Amps power socket point on independent board all as specified and directed.
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 4 sqmm drawn through and 1100 volt grade including PVC casing and capping of suitable size with all necessary fittings and provision of one run of 4 sqmm PVC insulated FRLS unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, including taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces complete all as specified and directed. Note: Two runs of 4 sqmm cable, one run of 4 sqmm earth conductor cable and one run of PVC casing and caping shall be measured and paid together as one unit length.
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 6 sqmm drawn through and 1100 volt grade including PVC casing and capping of suitable size with all necessary fittings and provision of one run of 6 sqmm PVC insulated FRLS unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, including taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces complete all as specified and directed. Note: Two runs of 6 sqmm cable, one run of 6 sqmm earth conductor cable and one run of PVC casing and caping shall be measured and paid together as one unit length.
S&F switch, piano type, 5 Amps, flush button, 230 volts, AC, one way all as specified and directed.
S&F switch piano flush type 15 Amps 230 volts all as specified and directed.
S&F socket outlet 5 Amps 5 Amps 2 cum 3 pin flush type multipurpose all as specified and directed.
S&F socket outlet 15 Amps 3 pin 5 Amps cum 3 pin 15 Amps, flush type multipurpose all as specified and directed.
S&F PVC ceiling rose 3 terminal suitable for 230 volts AC supply all as specified and directed.
S&F fan regulator electronic step type suitable for 1200/1400 mm sweep ceiling fan all as specified and directed.
S&F modular switch, 1 module, 1 way, 6 Amps, 230 volts, AC, all as specified and directed.
S&F modular switch, 1 module, 1 way, 16 Amps 230 volts, AC, all as specified and directed.
S&F socket outlet, 2 module, 6 Amps 2 cum 3 pin multipurpose all as specified and directed.
S&F socket outlet, 2 module, 2 pin 6A/ 3 pin 16 Amps, multipurpose all as specified and directed.
S&F fan regulator electronic modular step type, 2 module, suitable for 1200mm sweep ceiling fan all as specified and directed.
S&F in repairs, MCCB DB VTPN 4 Way, vertical type, suitable for MCCB as incomer 415 volts rated bus bars double door type including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCCB DB on board complete all as specified and directed.
S&F in repairs, MCB DB TPN 4 Way, with 200 Amps rated bus bars double door type and including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCB DB on board complete all as specified and directed.
S&F in repairs, MCB DB SPN 12 Way with 100 Amps rated bus bars double door type and including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCB DB on board complete all as specified and directed.
S&F in repairs, MCB DB SPN 4 Way with 100 Amps rated bus bars double door type and including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCB DB on board complete all as specified and directed.
S&F MCCB TPN 125 Amps ,25KA, 415 Volts, AC supply, fixed thermal magnetic settings, all as specified and as directed.
S&F MCB TPN 63A 'C' series 50Hz AC supply all as specified and as directed.
S&F MCB DP 63A 10KA 'C' series 50Hz AC supply all as specified and as directed.
S&F MCB DP 40A 10KA 'C' series 50Hz AC supply all as specified and as directed.
S&F MCB SP 5-32A 10KA 'C' series 50Hz 240 Volts AC supply all as specified and as directed.
S&F surface mounting LED light fitting, 20W, 230V, wall/ ceiling mounted type, with extruded aluminium housing and polycarbonate diffuser, 20W LED strip, integrated driver and all accessories internally pre wired complete and connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block and provision of 2 Nos. of PVC square blocks all as specified and directed. Make: HAVELLS LUMILINE PLUS or equivalent in CG/ Philips/ Wipro
S&F surface mounting LED light fitting, 10W, 230V, wall/ ceiling mounted type, with extruded aluminium housing and polycarbonate diffuser, 10W LED strip, integrated driver and all accessories internally pre wired complete and connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block and provision of 2 Nos. of PVC square blocks all as specified and directed. Make: HAVELLS LUMILINE PLUS or equivalent in CG/ Philips/ Wipro
S&F in repairs 34 Watts LED glare free luminaire recess mounted in square profile 2ft x 2ft size with 34 W high brightness SMD LEDs including electronic driver etc. complete with all accessories internally pre wired connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block all as specified and directed. Make: HAVELLS VENUS NEO HE 2x2 or equivalent in CG/ Philips/ Wipro
S&F in repairs 42 Watts LED glare free luminaire surface mounted type in rectangular profile,4' x 1' with electronic driver, 42W LEDs etc. complete with all accessories internally pre wired including connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block all as specified and directed. Make: HAVELLS PLUTO PANEL (SURFACE) 4 x 1 or equivalent in CG/ Philips/ Wipro
S&F 15 Watts LED security light fitting, with pressure die cast aluminium housing and lens embedded PC cover having top opening separate driver compartment with IP66 protection, 15 Watts high power LEDs, electronic driver including all accessories internally pre wired complete and connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block including provision of bracket made out of GI pipe light grade of suitable size and length and bent to shape fixed to walls/ poles with suitable MS clamps, bolt, nuts etc. complete all as specified and directed. Make: ENDURA PEARL model of HAVELLS or equivalent in Crompton Greaves/ Philips/ Wipro
S&F 25 Watts LED security light fitting, with pressure die cast aluminium housing and lens embedded PC cover having top opening separate driver compartment with IP66 protection, 25 Watts high power LEDs, electronic driver including all accessories internally pre wired complete and connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block including provision of bracket made out of GI pipe light grade of suitable size and length and bent to shape fixed to walls/ poles with suitable MS clamps, bolt, nuts etc. complete all as specified and directed. Make: ENDURA PEARL model of HAVELLS or equivalent in Crompton Greaves/ Philips/ Wipro
Taking down existing light fittings of any description and type and refixing the same back to its original or at other locations as directed by Engineer-in-charge including provision of required size new copper conductor from ceiling rose to connector block of light fitting all as specified and as directed.
S&F in repairs exhaust fan, 300mm sweep, 230/240 Volts, 900 RPM, heavy duty, single phase, metallic body with louvres and fixing arrangements with fixing bolts and provision of 3 core flexible copper conductor cable of size 1.5sqmm size from ceiling rose to connector of exhaust fan and testing including making circular hole of suitable in brick masonry wall and making good disturbed surfaces to match with existing surfaces all as specified as directed. Make: Havells Turbo Force SP model or equivalent model in Almonard/ Crompton Greaves
S&F ceiling fan, 230 volts, single phase, 1200mm sweep, 3 blades and provision of suitable size GI pipe down rod with all accessories complete including taking down existing unserviceable ceiling fan of any description and size and depositing to MES E/M store all as specified and as directed. Make: HAVELLS Model No. ES-50 or equivalent model in makes CG/ ORIENT
M&L for 50mm dia GI pipe medium grade cut to required length as per site requirement and fixed into walls in single piece without any joints as in supports for hanging of ceiling fans complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground vertically (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the earth plate at a depth not less than 1.5m below normal ground level connected to GI wire 4mm dia (7.5m long) by means of GI bolts nuts washers and GI wire protected by 15mm dia light grade GI pipe (7.5m long) and watering arrangements with 20mm dia GI pipe medium grade and GI funnel all as specified and shown in Electrical Plate No 3 of MES Schedule Part I including necessary excavation and earth work in any type of soil, charcoal, dust salt, PCC 1:2:4 type B1 in chamber, 40mm thick RCC 1:2:4 type B1 in cover slab with 8mm dia TMT bars at 100mm C/C both ways and with 8mm dia MS hook complete and testing all as specified and directed.
M&L for XLPE insulated, armoured, heavy duty electric LT UG cable with multi-stranded aluminium conductor, 1100 Volts grade, cross sectional area 16 Sqmm x 4 core, laid in trenches/ passing through pipe/ duct or fixed to wall including provision of necessary lugs/ thimbles/ ferrules, connecting up , testing and commissioning complete laid in repairs all as specified and as directed. Note: Excavation, earth work, cable cushioning, bricks/ GI pipe for protection shall be measured and paid separately under relevant items of this schedule.
M&L for approved riddled earth, spread dry in trenches as in cable cushioning at bottom and top including punning down all as specified and as directed. Note :- Punned thickness will be considered for payment.
M&L for burnt bricks, old size, sub class 'B' of designation 75, laid in trenches as in protection for UG cables all as specified and as directed.
M&L for GI tubes, light grade, 40mm bore, as in cable protection, fixed to poles/ walls with necessary MS clamps, bolts, nuts, washers or laid in trenches/ under roads/ crossing etc. all as specified and as directed.
M/s. KIRAN M CHOUGULE
SHRI.H.R.PATIL
ASHOK M RAJGOLKAR
M/s. N D KALING
M/s A N Kalbhavi
Vinod Enterprises
M/s. VIJAY ELECTRICALS
RAJENDRA KRISHNA SARAF
Manak landmarks
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .