Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.6 L+₹98,060 (5.55%)Rejected-Finance GROUND BALURGHAT COMPOUND NEAR TRIPURA ROAD KHANAPARA ROAD GUWAHATI KAMRUP METROPOLITAN ASSAM 781029 | KAMRUP METRO | ASSAM | 781029 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹19.0 L+₹1.3 L (7.33%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L3 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
12 Apr 2021, 6:00 pmClosed
GE (N) Bikaner
GE (N) Bikaner
OUTSOURCING SERVICES FOR OPERATION OF STP AND OTHER CONNECTED WORKS AT DRDO UNIT UNDER GE (N) BIKANER.
2021_MES_430592_1
GE (N) BKN-Token/75/2020-21
Open Tender
Miscellaneous Works
Item Rate
330 days
GE (N) Bikaner
Class D Category d(v)
9 documents required · 9 mandatory
₹500
GE (N) Bikaner
₹50,000
Yes
21 Jul 2021
15 Mar 2021
14 Apr 2021
15 Mar 2021
12 Apr 2021
29 Mar 2021
Amount
(Note for Sl item No. 1 to 2 : The rate quoted shall not be less than minimum wages as notified by Government/Local body whichever is higher (for 'B' area) . In Case the rates quoted are less than the minimum wages as notified by the Government of India/State Government/Local body whichever is higher, his tender will be treated as NON BONAFIDE and willl not be considered for acceptance. In such case, the lowest tender shall be determind by the lowest amount amongst valid/bonofied bids only). Outsourcing of services for 250 KLD STP at Umrao Complex (DRDO Unit) with 01 FGM (Semi skilledd) in each shift for 3 shifts round the clock will be employed by the contractor (each shift for 08 hours) and one helper (Un skilled) for one shift only all as directed by Engineer-in-Charge. Note Applicable for srl item No. 1 to 2 (i) Daily, weekly, mothly, quarterly, halfyearly and annual maint to be carried out and keeping records thereof. (ii) Daily log sheet attendance register for persons employed by the contractor to be maintained. (iii) All types of T&P reuired for day to day maintenance shall be provided by the contractor. (iv) All types of transportation if reqd for handling materials/eqpts etc shall be provided by the contractor. (v) All types of fire eqpts provided in all the installations shall be maintained and operated properly. (vi) All electrial fitting and fixures installed at STP installation to be maintained and contractor shall be responsible for any damage. (vii) All types of water tanks shall be maintined. (viii) All installations to be kept neat and clean all the time. (ix) In case of any damage, misuse, mishandling of Govt property, contractor will be held responsible for the same. (x) Chlorination of sewage water are to be carriedout and record to be maintainted. (xi) Medical needs to be provided by the contractor to the employees as and when required. (xii) First Aid Box with basic madicines to be kept in installation by the contractor. (xiii) Misuse of electricity and water to be penalised and effective recovery will be made by the department. (xiv) Outsourcing of services shall start immediately after acceptance of work. (xv) All garden, lawns, trees etc being planted in all the installations shall be maintained regularly and to be developed further as directed. (xvi) FGM should be ITI qualified or 02 years expereince in the perticular field. (xvii) Entire area inside and out side of STPs shall be cleaned properly by the contractor and cost shall be deemed included in the quoted rate. (xvii) Entire area inside and out side of STPs shall be cleaned properly by the contractor and cost shall be deemed included in the quoted rate. (xix) Treated water to be tested periodically as per Appx 'A' and record to be maintained. (xx) The contractor shall install biometric attendance machine at installation and attendance record be maintained. All the payment to be released to the contractor as per biometric record . All payments wil be paid through e-payment/digital payment.
Outsourcing of services for 180 KLD STP at Umrao Complex (DRDO Unit) with 01 FGM (Semi skilled) in each shift for 3 shifts round the clock will be employed by the contractor (each shift for 08 hours) and one helper (un skilled) for one shift only all as directed by Engineer-in-Charge.
Dismantling, transporting and reassembling of submersible motor after rewinding & replacement of worn out parts mentioned below incl rewinding of submersible motor 7.5 HP of 03 Phase, 415 volts with PVC insulated solid copper conductor (wire) superior quality of approved make , size & number of wire as per existing specification complete all as specified and as directed by Engr-in-Charge.
Supply & fix in replacement of the following unserviceable spare parts of submersible motor as per existing make and size against item No 3 above :- (a) GM Bearing Bush
(b) Rotor sleeve
(c) Water seal (KSB only)
(d) Cable seal
Dismantling of existing defective induction motor of 7.5 HP capacity, 03 phase, 415 volts 50 HZ and make from the foundation, disconnecting the electric connecting coupling pulley, and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor ( winding wire)as existing size and gauge complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed by Engineer-in-Charge.
(a) Ball bearing for 7.5 HP Make- SKF/NBC
Same as per item No. 5 above but capacity 2 HP 03 phase 415 Volts 50 Hz
(a) Ball bearing for 2 HP Make- SKF/NBC
Same as per item No. 5 above but capacity 1.5 HP 03 phase 415 Volts 50 Hz
(a) Ball bearing for 1.5 HP Make- SKF/NBC
Supply & fix in replacement MCCB 100 Amp capacity Four pole breaking capacity 25 KA at 415 volts including making connections by using suitable size copper lugs/thimbles and crimping tool complete all as specified and directed by Engr in charge. Make: - L&T/Havells/Crompton greaves
Taking out/dismantling of unserviceable compressor cap 7.5 HP including replacement of wornout components such as bearing as per existing size, compressor oil, rubber seal, repair to pump including reassembling installation, connecting and testing etc complete all as specified and directed by Engineer-in-Charge.
(a) Supply and fixing in replacement. Ball Bearing No. 3307 of Make :SKF/NBC
(b) Supply and fixing in replacement. Ball Bearing No 6306 of make : SKF/NBC
(c ) Supply and fixing in replacement. Rubber Seal for 7.5 HP compressor
(d) Supply and fixing inreplacement fan belt for air blower, induction motor suitable for 7.5 HP motor as per sample all as specified and directed by Engr-in-Charge.
(e) Engine Oil 20W40
Supply and fixing in replacement of butter fly valve of size 100 mm bore. Make : BIR/Advance/Leader/Sant
Supply and fixing in replacement of butter fly valve of size 150 mm bore. Make : BIR/Advance/Leader/Sant
Supply and fixing in replacement of butter fly valve of size 80 mm bore. Make : BIR/Advance/Leader/Sant
Supply and fixing in replacement of butter fly valve of size 50 mm bore. Make : BIR/Advance/Leader/Sant
Supply and fixing in replacement of butter fly valve of size 40 mm bore. Make : BIR/Advance/Leader/Sant
S&F in replacement MCB single pole, 240 volts of rating 6-32 Amps, breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge Make :- Schneider/ HPL/Legrand/ GE/ Seimens/L&T/Indo sian/C&S/Havells/BCH/ABB
S&F in replacement MCB suitable for 6 to 32 Amps, 240 Volt AC supply single pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ GE/ Seimens/L&T/Indo Asian/C&S/ABB/BCH
S&F in replacement MCB suitable for 32 Amps, 415 Volt AC supply triple pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ GE/ Seimens/L&T/Indo Asian/C&S/ABB/BCH
M&L in replacement air pressure gauge round type 0-150 Kg/cm2 make : Guru/ equivenlant
Supply only liquid chlorine (Sodium Hypochlorite at 12% to 16% ) all as directed by Engineer-in-Charge. Make- Chloromax/Shree Rayalaseema Hi-Strength Hypo Ltd Note :- (i) Sealed packed liquid chlorine container shall be supplied by the contractor on requirement basis at STP. (ii) Transportation incl labour charge will deemed in the item. (iii) The contractor ensure that liquid chlorine shall be kept for one month in advance at STP.
M&L in replacement of GI Pipe medium grade in trenches complete with fittings all as specified and directed by Engr-in-charge. Make : Jindal/TATA/Surya. (a) 150mm bore
(b) 100mm bore
(c) 80mm bore
(d) 50mm bore
(e) 40mm bore
( f) 25mm bore
(g) 20 mm bore
Supply and fixing in replacement gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for iron pipe complete all as specified (a) of size 80mm
(b) of size 50mm
(c) of size 40mm
(d) of size 25mm
(e) of size 20 mm
S&F detachable joint complete with rubber ring and necessary nut,bolts and washers suitable for CI/GI pipe line complete all as specified and directed by Engr-in-charge (a) 150mm bore
(b) 100mm bore
Supply and fixing in replacement of the following spare parts of panels contactor MNX 09 Amp (Make : L&T/C&F/Legrand)
Supply and fixing in replacement of the following spare parts of panels contactor MNX 18 - 25 Amp (Make : L&T/C&F/Legrand)
Supply and fixing in replacement of the following spare parts of panels contactor MNX 50 Amp (Make : L&T/C&F/Legrand)
Supply and fixing in replacement of Relay MN-2 as per sample
Taking out of UNSV analogue Amp meter and supply and fix new digital ebrit panel mounted AC ammeter (0-300A) of size 96 X 96 sqmm flush mounted case three phase, calss 0.5 item code PAMEBRITA 32. Make:-AE/HPL
Taking down UNSV phase indicator lamp supply and fix new phase indicator lamp (red, yellow & blue)
Taking out of UNSV analogue volt meter and supply and fix new digital ebrit panel mounted AC volt meter (0-500A) of size 96 X 96 sqmm flush mounted case three phase, calss 0.5 item code PAMEBRITA 32. Make:-AE/HPL
S&F electronic type single phasing preventer in existing panel boards (max 600v min 380v) three phase 415volts variation voltage 4% tripping time 2-5 sec max type VSP-1 complete all as directed by Engr in charge. Make:- L&T/Minilac/Siemens.
Supply and fix in replacement star delta timer range 0-30 second Make : C&S/L&T /Schiender
Supply and fixing in replacement of connector as per sample
Supply and fixing in replacement of Panel Lock as per sample
Labour only for taking out as directed and filling new sand, graavels, and otthrer filter media from dry sludge bed of sewage treatment plants complete all as specified and directed. (Note- Complete set of 4 beds)
Pumping out and removing of sewage water / mud from the aeration tank, and maturation tank and wet well using suitable dewatering pump / non clog sewage pump or manually and disposed off out side the MD land by means of closed portable tanks etc complete all as directed by the Engineer-in-charge
Cleaning of treated water tank by de-sludging,scraping the bottom wall with the help of scrapper/wire iron brush removing all scales, craked earth, dirt, mud/slit algi, fungus and other foreign deposited materials and dewatering the left over water and taking them out complete and painting of one coat by liquid bleaching powder complete all as specified and directed Engineer-in-Charge. (Note:- Periodicity of cleaining 6 months)
Cleaning of filter media chambers (02 Nos) by removing deposited material inside the chamber including lifting the material from the chamber and getting out from the chamber without any damage to the chamber including cleaning of filter media all as specified and directed by Engineer-in-Charge.
Dismantling opening and reassembling after repair/replacement of U/S spare parts of mono block pumping set capacity 7.5 HP spare parts required shall be measured and paid separately. Job includes disconnection from base foundation frame disconnecting electrically, reconnection, re-fixing in position transportation to work shop & back make of pump- Kirloskar
Supply only the following spare parts of mono block pump of 7.5 HP capacity (a) Gland Bush
(b) Gasket set manifold
Description all as per item No. 33 but of acpacity 5.5 HP spare parts shall be measured and paid separately.
Supply only the following spare parts of mono block pump of 5.5 HP capacity (a) Gland Bush
(b) Gasket set manifold
Description all as per item No. 33 but of acpacity 3 HP spare parts shall be measured and paid separately.
Supply only the following spare parts of mono block pump of 3 HP capacity (a) Gland Bush
(b) Gasket set manifold
Description all as per item No. 33 but of acpacity 1 HP spare parts shall be measured and paid separately.
Drilling /Boring (horizantally) suitable for following dia by pneumatic tools under existing road ( maximum 10 mtr width ) suitable for passing GI tubing complete all as specified
Cutting of road /hard standing for layng of pipe lines and making good the damaged surfaces to match with the existing surface (PCC or damaged road ) not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in deep and getting out complete all as specified and directed
Supply only the following spare parts of mono block pump of 1 HP capacity (a) Gland Bush
(b) Gasket set manifold
M/S SHREE SHYAM TRADERS
BIDAWAT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .