Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC AOC | |
| 2 | L2₹47.0 L+₹2.2 L (4.89%)Rejected-Finance SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹47.1 L+₹2.3 L (5.03%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹47.3 L+₹2.5 L (5.61%)Rejected-Finance FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | L4 | Rejected-Finance Not L1 | |
| 5 | Rejected-Technical ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | - | Rejected-Technical Present residual work in hand is more than Five times tendering limit as per existing policy in vogue. Hence not recommended please. |
| Sl No | Description | Qty | Unit | SHRI SAI ENTERPRISES L3 | ENJOY L2 | Shree Ayyappa Engineering L1 | M/S SOMANATH ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply only compressor oil as per requirement, complete all as specified and directed, Make :Servo, HP, BP, Sheetal N-68, Freezol 36 | 200 | Ltr | 400 ₹80,000 | 500 ₹1,00,000 | 280 ₹56,000 | 200 ₹40,000 Lowest |
| 2.00 | Supply only refrigerant (R-22) gas as per requirement, complete all as specified and directed. Make : MAFRON/FLORON/ REFRON/ FREON NOTE FOR ITEM NOS. 1 TO 2: The quantity of the above items shall only be operated to the extent required for topping-up as specified in the relevant other connected items of BOQ. | 200 | Kg | 2,100 ₹4,20,000 | 1,500 ₹3,00,000 | 999 ₹1,99,800 Lowest | 2,100 ₹4,20,000 |
| 3.00 | Supply and fix in repairs automatic capacity control pilot solenoid valve suitable for the liquid line of AC Plants of various capacity complete all as specified and directed, Make :- Rotex, Avcon, SPORLAN, DANFOSS. | 12 | Each Job | 8,000 ₹96,000 | 8,000 ₹96,000 | 6,070 ₹72,840 Lowest | 9,000 ₹1,08,000 |
| 4.00 | M & L for thermal insulation of 150mm bore chiller water piping with 50mm thick fibre glass wool, crown 150 and of density 24 Kg/Cum, the glass wool shall be covered with and including 24 SWG aluminium sheet cladding, complete all as specified and directed, Make: Lloyd's / TWIGA/ FGP Ltd. | 65 | RM | 900 ₹58,500 | 850 ₹55,250 Lowest | 1,010 ₹65,650 | 1,000 ₹65,000 |
| 5.00 | -Dittio- all as per item No. 04 above but of 80mm bore chiller water piping | 60 | RM | 600 ₹36,000 | 550 ₹33,000 Lowest | 561 ₹33,660 | 650 ₹39,000 |
| 6.00 | -Dittio- all as per item No. 04 above but of 50mm bore chiller water piping | 60 | RM | 600 ₹36,000 | 550 ₹33,000 Lowest | 561 ₹33,660 | 650 ₹39,000 |
| 7.00 | Pumping down the existing refrigerant from the plant of 75/80 TR capacity, carrying out the leakage testing of plant with the pressure of Nitrogen gas and monitoring for 24hrs to assess leakages, rectification of leakage by brazing & replacement of necessary gaskets wherever required, vacumizing of the plant by vaccum pump and keep-it upto 24 hours for testing and rectification of leakages if any, finally recharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure etc complete including testing of the plant for smooth functioning complete all as specified & directed.
Location : Missare Mine, TS Mahul | 4 | Each Job | 7,900 ₹31,600 | 6,000 ₹24,000 Lowest | 7,040 ₹28,160 | 9,000 ₹36,000 |
| 8.00 | Supply and fix in repairs hi wall split units indoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality including taking down old u/s indoor AC unit of capacity 2 Ton electric driven single phase 230 Volt complete all as specified and directed. | 6 | Each | 25,000 ₹1,50,000 | 21,000 ₹1,26,000 | 20,010 ₹1,20,060 Lowest | 25,000 ₹1,50,000 |
| 9.00 | -ditto- all as per item No 8 above but for 1.5 Ton capacity complete all as specified and directed. | 7 | Each | 19,000 ₹1,33,000 | 17,000 ₹1,19,000 Lowest | 19,000 ₹1,33,000 | 19,000 ₹1,33,000 |
| 10.00 | Supply and fix in repairs hi wall split units outdoor (Condener unit) of capacity 2 Ton including filling of refrigerant including taking down old u/s outdoor AC unit complete all as specified and directed. | 6 | Each | 46,000 ₹2,76,000 Lowest | 46,000 ₹2,76,000 Lowest | 55,500 ₹3,33,000 | 46,000 ₹2,76,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹93,000
Closing Date
24 Sept 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) Mankhurd
GE (NW) Mankhurd
REPAIR AND MAINT OF DEFECTIVE , BURNOUT AC, PUMPS, MOTORS AND OTHER RELATED ACCESSORIES AND OTHER MAINT WORKS AT MANKHURD, MAHUL SEWRI UNDER GE (NW) MANKHURD.
2026_MES_779650_2
8607/E8
Open Tender
Civil Works
Item Rate
270 days
Mankhurd
As per tender document
8 documents required · 8 mandatory
₹500
GE (NW) Mankhurd
₹93,000
Yes
29 Oct 2026
3 Sept 2026
26 Sept 2026
3 Sept 2026
24 Sept 2026
10 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply only compressor oil as per requirement, complete all as specified and directed, Make :Servo, HP, BP, Sheetal N-68, Freezol 36 | 200 | Ltr | - | - |
| 2 | Supply only refrigerant (R-22) gas as per requirement, complete all as specified and directed. Make : MAFRON/FLORON/ REFRON/ FREON NOTE FOR ITEM NOS. 1 TO 2: The quantity of the above items shall only be operated to the extent required for topping-up as specified in the relevant other connected items of BOQ. | 200 | Kg | - | - |
| 3 | Supply and fix in repairs automatic capacity control pilot solenoid valve suitable for the liquid line of AC Plants of various capacity complete all as specified and directed, Make :- Rotex, Avcon, SPORLAN, DANFOSS. | 12 | Each Job | - | - |
| 4 | M & L for thermal insulation of 150mm bore chiller water piping with 50mm thick fibre glass wool, crown 150 and of density 24 Kg/Cum, the glass wool shall be covered with and including 24 SWG aluminium sheet cladding, complete all as specified and directed, Make: Lloyd's / TWIGA/ FGP Ltd. | 65 | RM | - | - |
| 5 | -Dittio- all as per item No. 04 above but of 80mm bore chiller water piping | 60 | RM | - | - |
| 6 | -Dittio- all as per item No. 04 above but of 50mm bore chiller water piping | 60 | RM | - | - |
| 7 | Pumping down the existing refrigerant from the plant of 75/80 TR capacity, carrying out the leakage testing of plant with the pressure of Nitrogen gas and monitoring for 24hrs to assess leakages, rectification of leakage by brazing & replacement of necessary gaskets wherever required, vacumizing of the plant by vaccum pump and keep-it upto 24 hours for testing and rectification of leakages if any, finally recharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure etc complete including testing of the plant for smooth functioning complete all as specified & directed.
Location : Missare Mine, TS Mahul | 4 | Each Job | - | - |
| 8 | Supply and fix in repairs hi wall split units indoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality including taking down old u/s indoor AC unit of capacity 2 Ton electric driven single phase 230 Volt complete all as specified and directed. | 6 | Each | - | - |
| 9 | -ditto- all as per item No 8 above but for 1.5 Ton capacity complete all as specified and directed. | 7 | Each | - | - |
| 10 | Supply and fix in repairs hi wall split units outdoor (Condener unit) of capacity 2 Ton including filling of refrigerant including taking down old u/s outdoor AC unit complete all as specified and directed. | 6 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
BOQ_882849.xls
BOQ • 1.09 MB
8607General.pdf
Tender Documents • 0.85 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .