REPAIR AND MAINT OF DEFECTIVE , BURNOUT AC, PUMPS, MOTORS AND OTHER RELATED ACCESSORIES AND OTHER MAINT WORKS AT MANKHURD, MAHUL SEWRI UNDER GE (NW) MANKHURD.
2026_MES_779650_2
8607/E8
Open Tender
Civil Works
Item Rate
270 days
Mankhurd
As per tender document
8 documents required · 8 mandatory
₹500
GE (NW) Mankhurd
₹93,000
Yes
3 Sept 2026
3 Sept 2026
19 Sept 2026
3 Sept 2026
17 Sept 2026
10 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply only compressor oil as per requirement, complete all as specified and directed, Make :Servo, HP, BP, Sheetal N-68, Freezol 36 | 200 | Ltr | - | - |
| 2 | Supply only refrigerant (R-22) gas as per requirement, complete all as specified and directed. Make : MAFRON/FLORON/ REFRON/ FREON NOTE FOR ITEM NOS. 1 TO 2: The quantity of the above items shall only be operated to the extent required for topping-up as specified in the relevant other connected items of BOQ. | 200 | Kg | - | - |
| 3 | Supply and fix in repairs automatic capacity control pilot solenoid valve suitable for the liquid line of AC Plants of various capacity complete all as specified and directed, Make :- Rotex, Avcon, SPORLAN, DANFOSS. | 12 | Each Job | - | - |
| 4 | M & L for thermal insulation of 150mm bore chiller water piping with 50mm thick fibre glass wool, crown 150 and of density 24 Kg/Cum, the glass wool shall be covered with and including 24 SWG aluminium sheet cladding, complete all as specified and directed, Make: Lloyd's / TWIGA/ FGP Ltd. | 65 | RM | - | - |
| 5 | -Dittio- all as per item No. 04 above but of 80mm bore chiller water piping | 60 | RM | - | - |
| 6 | -Dittio- all as per item No. 04 above but of 50mm bore chiller water piping | 60 | RM | - | - |
| 7 | Pumping down the existing refrigerant from the plant of 75/80 TR capacity, carrying out the leakage testing of plant with the pressure of Nitrogen gas and monitoring for 24hrs to assess leakages, rectification of leakage by brazing & replacement of necessary gaskets wherever required, vacumizing of the plant by vaccum pump and keep-it upto 24 hours for testing and rectification of leakages if any, finally recharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure etc complete including testing of the plant for smooth functioning complete all as specified & directed.
Location : Missare Mine, TS Mahul | 4 | Each Job | - | - |
| 8 | Supply and fix in repairs hi wall split units indoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality including taking down old u/s indoor AC unit of capacity 2 Ton electric driven single phase 230 Volt complete all as specified and directed. | 6 | Each | - | - |
| 9 | -ditto- all as per item No 8 above but for 1.5 Ton capacity complete all as specified and directed. | 7 | Each | - | - |
| 10 | Supply and fix in repairs hi wall split units outdoor (Condener unit) of capacity 2 Ton including filling of refrigerant including taking down old u/s outdoor AC unit complete all as specified and directed. | 6 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
BOQ_882849.xls
BOQ • 1.09 MB
8607General.pdf
Tender Documents • 0.85 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .