Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 CrAdmitted-Finance | ₹4.3 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical BEHIND WATER WORKS ST NO 4 JAIN NAGRI ROAD ABOHAR | - | - | Rejected-Technical Non Responsive |
| Sl No | Description | Qty | Unit | GURINDER PAL SINGH CONTRACTORS L1 |
|---|---|---|---|---|
| 1.00 | Design, Drawing, fabrication, supply, erection,testing and commissioning of Vertical lift slidingtype gate with frame consisting of skin plate,sealing frame, stiffeners, horizontal and vertical girders, guide, stainless steel flat/Brass flat, rivets,wedges, lifting rods etc., with all accessories as per relevant IS code including frame & gate complete set for Canal Cross, Escape, Head regulator /Tank head regulator including cost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, seal fixing, tools and tackles
etc., applying two coat of zinc rich epoxy primer to give dry film thickness of 70+/-5 microns and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150+/-5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., complete as per specifications and approved drawings with all lead and lifts, including packing & forwarding,
transportation charges for structural steel components and other materials. | 28.06 | tonnes | 2,10,000 ₹58,92,600 Lowest |
| 2.00 | Design, Drawing, fabrication, supply, erection and commissioning of Trestle assy/Railing decking/Trash rack/Structural steel hoist bridge/ structural steel hoistsupporting structure for monorail / Catwalk bridge for connecting spillway piers for all type of sluice with embedded parts consisting of columns, beams, bracings, stiffeners, ties, chequered plate covering, hand railing, ladder etc., with all other accessories for operating gates, other structure including cost of all materials, machinery, labour, tools and tackles, cutting, aligning, anchoring, welding, finishing, cleaning, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings, including packing & forwarding, transportation charges for structural steel components and other materials. | 48.36 | tonnes | 1,60,000 ₹77,37,760 Lowest |
| 3.00 | Supply of water seal musical hollow knot type for canal gate having size 125x12x45 mm as per IS 11855 specification. | 65 | Per mtr | 3,000 ₹1,95,000 Lowest |
| 4.00 | Supply of water seal Flat type for canal gate having size 100x12 mm as per IS 11855 specification. | 134 | Per mtr | 2,700 ₹3,61,800 Lowest |
| 5.00 | Supply of cast steal roller for canal gate of grade 200- 400N as per IS 1030 specification, having size 200 mm Dia and 60 mm Thick including brass bush and 2nos brass spacer of 10mmick & single piece stainless steel monolithic pin complete set as per drawing and specification. | 80 | Each | 18,000 ₹14,40,000 Lowest |
| 6.00 | Supply and fixing of stainless steel plate grade 304 having size 75x8 MM | 70 | Per mtr | 1,500 ₹1,05,000 Lowest |
| 7.00 | Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity manually operated rope drum hoist according to relevant IS code, consisting of hoist platform bridge, rope drums, connecting shaft, gear system unit, pulleys, wire rope, Gate position indicator, manual operation system, etc. complete, with all accessories for operating gates including cost of all materials, machinery, labour, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oil filling, tools and tackles, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings, including packing & forwarding, transportation charges for all materials. | 67.2 | Per tonne capacity | 80,000 ₹53,76,000 Lowest |
| 8.00 | Jungle clearance, ordinary including cutting bushes, shrubs and plants etc. for original earth work. | 1,783.74 | Per sqm | 0.5 ₹891.87 Lowest |
| 9.00 | De-watering by pumping water to maintain desired level including cost of POL/ power consumption etc. complete. 10 to 19 HP | 83 | Per Hr | 25 ₹2,075 Lowest |
| 10.00 | Labour charges for making Coffer Dam/ Ring Bundhs with earth filled EC bags including stitching along with transportation and placement at required locations in water including all leads and lifts complete excluding the cost of EC bag but including the cost of sutli. | 5,760 | Per Nos | 10 ₹57,600 Lowest |
Tender Value
₹3.5 Cr
EMD Value
₹7.1 L
Closing Date
14 Mar 2023, 6:00 pmClosed
Project Director PMU (RWSRPD) and Chief Engineer
Office of the Project Director PMU(RWSRPD) and Chief Engineer Water Resources(North) Hanumangarh
Repair and renovation of Escape (RD 629.000) of IGF, Repairing of cross regulator at RD 69 of IGMN (Package 339)
2023_WRDAS_321311_5
PMU_NIB_05_2022-23
Open Tender
Civil Works
Item Rate
450 days
Hanumangarh Distt
As per bid documents
3 documents required · 3 mandatory
₹10,000
Executive Engineer BSR Division
₹7.1 L
Yes
Hanumangarh
24 Mar 2023
23 Feb 2023
15 Mar 2023
23 Feb 2023
14 Mar 2023
23 Feb 2023
23 Feb 2023 - 2 Mar 2023
2 Mar 2023
Amount
Design, Drawing, fabrication, supply, erection,testing and commissioning of Vertical lift slidingtype gate with frame consisting of skin plate,sealing frame, stiffeners, horizontal and vertical girders, guide, stainless steel flat/Brass flat, rivets,wedges, lifting rods etc., with all accessories as per relevant IS code including frame & gate complete set for Canal Cross, Escape, Head regulator /Tank head regulator including cost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, seal fixing, tools and tackles etc., applying two coat of zinc rich epoxy primer to give dry film thickness of 70+/-5 microns and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150+/-5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., complete as per specifications and approved drawings with all lead and lifts, including packing & forwarding, transportation charges for structural steel components and other materials.
Design, Drawing, fabrication, supply, erection and commissioning of Trestle assy/Railing decking/Trash rack/Structural steel hoist bridge/ structural steel hoistsupporting structure for monorail / Catwalk bridge for connecting spillway piers for all type of sluice with embedded parts consisting of columns, beams, bracings, stiffeners, ties, chequered plate covering, hand railing, ladder etc., with all other accessories for operating gates, other structure including cost of all materials, machinery, labour, tools and tackles, cutting, aligning, anchoring, welding, finishing, cleaning, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings, including packing & forwarding, transportation charges for structural steel components and other materials.
Supply of water seal musical hollow knot type for canal gate having size 125x12x45 mm as per IS 11855 specification.
Supply of water seal Flat type for canal gate having size 100x12 mm as per IS 11855 specification.
Supply of cast steal roller for canal gate of grade 200- 400N as per IS 1030 specification, having size 200 mm Dia and 60 mm Thick including brass bush and 2nos brass spacer of 10mmick & single piece stainless steel monolithic pin complete set as per drawing and specification.
Supply and fixing of stainless steel plate grade 304 having size 75x8 MM
Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity manually operated rope drum hoist according to relevant IS code, consisting of hoist platform bridge, rope drums, connecting shaft, gear system unit, pulleys, wire rope, Gate position indicator, manual operation system, etc. complete, with all accessories for operating gates including cost of all materials, machinery, labour, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oil filling, tools and tackles, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings, including packing & forwarding, transportation charges for all materials.
Jungle clearance, ordinary including cutting bushes, shrubs and plants etc. for original earth work.
De-watering by pumping water to maintain desired level including cost of POL/ power consumption etc. complete. 10 to 19 HP
Labour charges for making Coffer Dam/ Ring Bundhs with earth filled EC bags including stitching along with transportation and placement at required locations in water including all leads and lifts complete excluding the cost of EC bag but including the cost of sutli.
Earth work excavation in ordinary soil for main canal and branches having discharge 10 cumecs and above: Kassi work undressed.
Carriage of earth with all leads Carriage of Bats Ballast, Kankar, Sand, Bajri, Stone, Grit, Murram, Soling Stones For Road, Water, Good Earth.
Extra on earthwork for laying in 15 to 25 cms layers including Dressing & Watering as per specifications (Water to be made available by the department at one place of work site).
Ramming of earthwork in layers by wooden or iron rammers as per specifications to attain a density 90% of Maximum Dry Density.
Dressing of earthwork.
Add extra for earth taken from private land, land to be arranged by the contractor through private negotiations. Item applicable on certification by Ex. En. that no earth is available within canal boundary. For Command Area
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Brick on edge flooring with bricks of class designation 75 including cement slurry & pointing in CM (1 : 3) etc. complete laid on 20 mm thick bed of : Cement Sand Mortar 1 : 4
Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish : 20mm thick
Providing and laying granular sub-base material as per MoRTH specification table 400-1, having P.I. not more than 6 including spreading in layers not exceeding 150 mm compacted thickness and consolidation by 8-10 tonne power roller to required camber and grade including cost of water and hire charges of machinery including T&P with all lead (Compacted thickness to be measured) with CBR of material not less than 15 (For rural roads only) as per MoRTH specification clause 401 with all lead For Grading III Material
Labour charges for laying brick edging up to 23 cm deep and up to 11.5 cm. wide according to approved brick size (to be specified) including digging of trenches, fixing of bricks in position, refilling and disposal of surplus earth etc. complete.
Supply of well burnt pucca bricks at site size 23x11x7 Cms. Class designation 100
Labour charges for removing existing vertical lift canal gate and lowring of new / existing gate having weight 5 to 8 MT including, greasing oiling ,cutting/welding of accesoories as per direction of Engineer incharge as per specification and drawing of the department.RD 68.900 Cross Regulator
Labour charges for removing existing vertical lift canal gate and lowring of new / existing gate having weight 3 to 5 MT including, greasing oiling ,cutting/welding of accesoories as per direction of Engineer incharge as per specification and drawing of the department.SOG Branch Head Regulator
Removing of old water seal from canal gate including cutting of existing nut bolts etc, complete in all respect in sides
supply of Water seal angle sshaped Z type for canal gate having size 110x14x67 mm as per IS 11855 specificatiopn
Fixing of new water seal including punching hole and nut bolt complete in all respect
Labour charges for fixing roller and welding of lock plates minor repair of gates for making roller in alignment including drilling new hole of appropriate size
cardium lubrication compound (for steel wire rope having min. kinemetic viscosity 200 and penetrating lubrication type.(RD 68.900 Cross Regulator & SOG Branch Head Regulator)
Transportation charges with utility van and with four man(two helper- one welder and one fitter) with welding parts, cutting items and extra tools and tackles required for fitting/ repair work of gate parts and head etc. Upto 50 km
Painting with synthetic enemal paint of approved brand and manufacture to give an even shade one or more coats on old work
Painting of canal gate with 2-pack zinc chromate/phosphate primer in two coats. The dry thickness of each coat should be 35 microns and should not be less then 70 microns. And painting of 2 epoxy paint in three coats of approved color as per Engineer in charge, confirming to IS 104
Sand blasting of new steel surface. Confirming to IS 1477 class B
Add extra for old steel scaled surface in item 2
Supplying and fixing of chain link fencing with angle iron posts 50x50x6 placed at evry 3 Mtr. Apart 30 cm in ground embeded in cement concrete 1:3:6(30x30x45 cm) corner and evry tenth post to be strutted with (50x50x6 cm) angle iron provided and fixed and fitted with posts including erth work in excavation etc. complete with chain link size. 50mm x 50mm x 3.15mm
Pointing on brick work or brik flooring with cement mortar 1:3 ( 1 cement : 3 fine sand) flush/Ruled/Struck or weathered pointing.
Centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for:suspended floor, cantilivers, bands, coping bed plates, anchor blocks, sills, chajjas, lintel, beam, plinth beam etc.
Earth work excavation in ordinary soil for main canal and branches having discharge 10 cumecs and above; Earth work undressed with combined lead uptp 50 m.
Carriage of Bats Ballast, Kankar, Sand, Bajri, Stone, Grit, Murram, Soling Stones For Road, Water, Good Earth.
Dressing of side slops for preparetion of sub grade for lining including removal of irregulerities upto 7.5 cm depth.
Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately)For fixed portion.Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron) .
For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately)Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron) .
Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.)With float glass panes of 8 mm thickness
Filling the gap upto 5 mm depth and 5 mm width in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. With brass cover plate
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing sun control film, thickness of film 1 Mil Visible Light Transmittance 4-24% & Solar Energy Transmittance 42-51% & Total solar Energy rejection 37-43%of approved colour and shade , complete in all respect , at all level , as directed by engineer- in -charge.
Making the opening in masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground. For door/windows/clerestory windows
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scafolding old work(one or more coats) including scrapping surface and necessary repaires. Colour change
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scafolding old work(one or more coats)
Supply of well burnt pucca bricks at site size 23 x 11 x 7 Cms. Class designation 100.
Earth work in excavation including stacking and disposal of surplus earth with all lifts and lead upto 1000 m exclusive of compansations of earth(Morth specification clause 301 to 305) Machenicaly by power shovel including machenical loading and carriagr upto 1 Km by tipper and dumper
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:
Providing and fixing steel gate, grating , and grills made ofangles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification :
Supply and fixing of pole OEM fabricated hot dip glvenised M.S. overhang (48.3X3.25mm) with cap (400x88.9/114.3x3.25 mm)over the existing poles all as per pre approved by engineer in charege for additional tectnical perameter of products/work refer anexure "A" attatched with this BSR single arm overhang
Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSRHigh power LED flood light minimum lumen output 18650 lm .
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 6.0 Sq. 4 core
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 1.5 Sq. 2 core
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 6A to 32 A rating
Providing & Fixing of 1200 mm sweep BLDC technology power saving ceiling fan which can withstand on votage fluctuations from 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 220 CMM, speed minimum 330 RPM ( tolerance as per IS:374 2019 ) THD less then 10% and complete with down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe up to 80 cm , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .without remote.
Supply , Installation, Testing and Comissioning of Window type Air conditioners as per BEE star rating complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 230 V +/- 10% with low & high voltage cutoff and 50 Hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation R-32/R-410 Green Refrigerant with Scroll / rotary compressor complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1.5 TR ISEER not less then 3.0
Light vehicle i.e. Jeep, and cars etc. Inspection vehicle
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.41 MB
FinalbidP-339.pdf
Tender Documents • 4.06 MB
BOQ_569810.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .