Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.5 L+₹1.3 L (6.01%)Rejected-Finance INDEX NO D 1478 CE SC PUNE PLOT NO 44 11 KACHNAYAKANHALLI VILLAGE JIGANI HOBLI ANEKAL TALUK BANGALORE PIN 560 106 KARNATAKA STATE | 560106 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹23.5 L+₹2.3 L (10.9%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹23.9 L+₹2.7 L (12.7%)Rejected-Finance KOTHAR MAJALI SADASHIVGAD KARWAR UTTARA KANNADA 581360 | KARWAR | UTTARA KANNADA | KARNATAKA | 581360 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹24.6 L+₹3.4 L (15.9%)Rejected-Finance H NO 374 1 BUILDING I AQUEM PLAZA TF F4 OPP DEVKI STEEL AQUEM BAXIO MARGAO GOA 403707 | MARGAO | SOUTH GOA | GOA | 403707 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
26 Sept 2024, 6:00 pmClosed
GE (SB) KARWAR
GE (SB) KARWAR
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION, FITTINGS AND FIXTURES, FLAME PROOF FITTINGS/DBs INCLUDING EARTHING OF OTM AT SITE E UNDER GE(SB) KARWAR.
2024_MES_671132_1
8231/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (SB) KARWAR
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (SB) KARWAR
₹70,000
Yes
25 Nov 2024
3 Sept 2024
28 Sept 2024
3 Sept 2024
26 Sept 2024
19 Sept 2024
3 Sept 2024 - 17 Sept 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in existing conduit and making good disturbed surfaces to match with the existing surface complete all as specified and directed by Engr-in-Charge.
(a) One light/fan point controlled by one switch
(b) One 3/5 pin socket outlet 6 Amp on same board with other switches.
All as per item No.2 above but One 3 pin socket outlet 5 Amp on independent board.
All as per item No.2 above but with cables 2.5 Sqmm for one 3 pin socket outlet 15 Amps on independent board
All as per item No. 2 above but with cables 4 Sqmm for one 3 pin socket outlet 15 Amps on independent board
Supply & fix in repairs MCB TPN, 16 To 32 AMP, 415 Volts, 3 phase, 10 KA Capacity all as specified and directed. MAKE: Havells/ABB/Legrand/Schneider/L&T or as approved by GE.
Supply & fix in repairs MCB TPN, 40 To 100 Amps, 415 Volts, 3 phase, 10 KA Capacity all as specified and directed. MAKE: Havells/ABB/Legrand/Schneider/L&T or as approved by GE.
Supply & fix in repairs MCB SPN, 32 Amps, 'C Series ,230 Volts, Single phase, 10 KA Capacity all as specified and directed. MAKE: Havells/ABB/Legrand/Schneider/L&T or as approved by GE.
Supply & fix in repairs MCB SP, 6 to 32 Amps, 'C' Series, 230 Volts, Single phase, 10 KA Capacity all as specified and directed. MAKE: Havells/ABB/Legrand/Schneider/L&T or as approved by GE.
Taking down ceiling fan/exhaust fan of any sweep, dismantling, replacing defective part, overhauling, cleaning, greasing, rewinding, etc and hanging up/fixing back in the original position, connecting up and testing complete all as directed. NOTE: 1. The unit rate quoted shall be deemed to include for minor items viz nuts,bolts split pin and rubber wheel, however capacitor & bearing shall be measured sperately under respective items. 2. Rewinding of fan will be measured and paid for separately under respective items.
Supply and fix ceiling fan regulator electronic step type 230 Volts single phase all as specified and directed. MAKE: Anchor/Bajaj/Havells/Crompton or as approved by GE
Supply and fix capacitor of 2.5 mfd for ceiling fan/exhaust fan complete all as specified and directed.
Supply and fix bearing No.6201/6202/6203 for ceiling fan/exhaust fan complete all as directed.
M & L for rewinding ceiling fan 1200/1400 mm sweep with super enamalled copper wire of exisiting gauge including insulation material varnishing and drying all as directed.
M&L for Painting of ceiling fans complete, in situ/lying in store with synthetic enamel paint (white colour) by spraying including filling cavities with filler, one coat after cleaning all dust etc
S&F in replacement cup made of plastic complete with nut bolt for fixing in position suitable for ceiling fan 1200mm/1400mm sweep
S&F in replacement blade suitable for 1200mm sweep Ceiling fan complete all as directed.
S&F in replacement blade suitable for 1400mm sweep Ceiling fan complete all as directed.
S&F in replacement of ceiling fan downrods of length 1-2 ft suitable for 1200/1400mm ceiling fans. The quoted rate should also include for the clamps necessary for the proper fixing of the ceiling fan.
All as per item No 14.00 above but exhaust fan of 300 mm sweep.
All as per item No.14.00 above but exhaust fan of 450 mm sweep, 3 phase 415 Volt.
M & L for rewinding Heavy duty ventilation fans of various sizes ranging from 1500 to 3400 cmh, 6000 cmh ,14000 cmh 3 phase 415 Volt with super enamalled copper wire of exisiting gauge including insulation material varnishing and drying all as directed.
Taking down submain wiring cable any number of runs alongwith earth wire from the existing concealed or surfacae conduit and offering credit as per schedule of credit all as directed.
M&L for Wiring circuit/submain wiring alongwith earth wire with 2x6.0 sq. mm +1x4.0 sq. mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/recessed as required In existing steel/conduit, casing/caping, surface/ recessed complete all as specified and directed by Engr-in-Charge.
M&L for Wiring circuit/submain wiring alongwith earth wire with 2x6.0 sq. mm +1x4.0 sq. mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/recessed as required In casing/caping complete all as specified and directed by Engr-in-Charge.
M&L for Wiring circuit/submain wiring alongwith earth wire with 2x4.0 sq. mm +1x2.5 sq. mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/recessed as required In casing/caping complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs switch Piano 6 Amps one way flush type, matching with existing make, ISI marked, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs decorative modular switch 6 Amps single pole flush type, matching with existing all as specified and as directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs socket outlet 3/5 pin 6 Amps flush type, matching with existing make ISI marked, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs switch Piano 15/16/20 Amps one way flush type, matching with existing make ISI marked, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs socket outlet 3/5 pin 15/16 Amps flush type multi purpose, matching with existing make ISI marked, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs switch socket combination 5 pin 16 Amps flush type multi purpose, matching with existing make ISI marked, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs Flame proof Switch rotary type with termination box in LM6, 16A, single pole 250V all as specified and as directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth all as specified and as directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs Flame proof Switch flame proof rotary type with termination box in LM6, 16A, double pole 250V all as specified and as directed. MAKE: Havells/Anchor/Legrand/Phillips.
Material and labour for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply & Fxing in repiar 20 W LED batten including tube rod of length 4 feet, 230 Volts, complete with all connected accessories including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells/Bajaj/Philips/ Wipro/ C&S or as approved by GE.
S&F in repair T8 LED tube rod 18/20 W, 4 feet length, 6000K complete with all accessories as specified and as directed. Make : Havells/Bajaj/Philips/Wipro/C&S.
S&F in repair 10 watt LED light fittings 2 feet including making necessary connection complete all as specified and directed. Make : Havells/Philips/C&S/Bajaj.
Supply and fix in repairs 2ft x 2ft LED luminaire mounted on ceiling 24W complete with all aceessories including making necessary connection all as specified and directed by Engr-in-Charge. Make : Havells/Philips/C&S/Bajaj.
Supply and fix in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB single pole 20 Amps 240 Volts all as specified and directed. MAKE: Havells/ABB/Legrand/Schneider/L&T or as approved by GE.
S & F in repairs MCB DB TPN 415 Volt 4 way & single door and factory made complete with bus bar and din channel complete all as directed. MAKE: Havells/ABB/Legrand/Schneider/L&T or as approved by GE.
S&F in repairs MCB DB SPN, 8 way, 240 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed. MAKE: Havells/ABB/Legrand/Schneider/L&T or as approved by GE.
S& Fix in repairs flame proof MCB distribution board TPN Color -Smoke Gray, Material LM6 20 kg Approx size and IP 66 protection complete all as specified and directed.
Material and labour for paintng of existing DBs/Panel Boards (SPN/TPN or any other DB,Panel boards etc). The work should include proper cleaning of the DBs, applying one coat of rustproof primer along with two coats of spray enamel painting and ensuring that the doors, nobs and other movable parts of the panels/DBs are adjusted properly and fitted in place. Note:The unit rate quoted shall be deemed to be included the elements of labour only for painting and fitting of movable parts properly. If replacement of parts/items is required to make the fittings functional, the cost for labour and material for the same will be measured and paid for under relevant items of this schedule hereinafter and in such cases the above items will not be measured and paid for.
Supply and fix in repairs Electric Panel Door Handles Lock Knob type and door locks made with backelite material necessary for proper closing and opening of the Panel doors complte all as specified and directed.
Supply and fixing LED light fitting 1x40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size
M&L for testing of resistence of earthpits of transformer, panels , buildings etc after testing report will be furnished to Engr-in Charge in standard format approved by Engr-in Charge.
M & L for earthing complete with galvanized steel earth electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead by means of nuts, bolts, checknuts and washers of galvanized iron or steel as shown in electrical plate No 3 connected to earthing test point including testing on completion all as specified and directed. NOTE: The unit rate quoted shall be deemed to include for necessary excavation and earth work in any type of soil, PCC 1:3:6 type CI chamber, funnel with GI medium grade watering pipe 15 mm bore, RCC 1:2:4 type B1 in cover slabs 50 mm thick with 8 mm dia TMT bars @ 140 mm c/c both ways etc complete.
Taking down carefully existing building security light/ Industrial work shop high /mid bay luminaires of any type,in any height rectifing the defects by repairs /replacement of Capacitor/ballast/igntor/lamp and tightening the loose connection etc & refixing in position complete all as directed. Note : Rates are deemed to include changing of spares "Supply only in repairs" under relevant items of this schedule hereinafter and the Ladder/sceisor lift/T&P for rectifying the defects at the ceiling of mid bay/high bay height as well as security light.
S&F in repair LED 60W edge series bldg security light fitting pressure die -cast housing with toughned glass and including LEDs with secondary optics and IP 66 protection complete all as specified and directed.
S& F in repairs LED 80 watt industrial high bay luminaire iP65 protected LED midbay with PDC housing suitable for ceiling (surface/suspended) mount all as specified and directed. Make: Bajaj/Havells/Crompton or as approved by GE.
Supply and fixing flameproof LED highbay lights of 90 Watt capacity in replacement of old unserviceable HPSV lights of capacity 150/125 Watt. The LED Highbay ligts should be made with Aluminiunm die cast housing for efficient thermal management along with suitable driver and flicker free illumintion. The quoted rate should include taking down of existing highbay lights present at a height of 10-15 meters and fixing the LED lights at the same place. Make: Bajaj/Havells/Crompton or as approved by GE.
Supply and fixing flameproof LED highbay lights of 120 Watt capacity in replacement of old unserviceable HPSV lights of capacity 200/250 Watt. The LED Highbay ligts should be made with Aluminiunm die cast housing for efficient thermal management along with suitable driver and flicker free illumintion. The quoted rate should include taking down of existing highbay lights present at a height of 10-15 meters and fixing the LED lights at the same place. Make: Bajaj/Havells/Crompton or as approved by GE.
Supply and fixing flameproof LED highbay lights of 150 Watt capacity in replacement of old unserviceable HPSV lights of capacity 400 Watt. The LED Highbay ligts should be made with Aluminiunm die cast housing for efficient thermal management along with suitable driver and flicker free illumintion. The quoted rate should include taking down of existing highbay lights present at a height of 10-15 meters and fixing the LED lights at the same place. Make: Bajaj/Havells/Crompton or as approved by GE.
S&F in repairs ignitor for HPMV light fitting suitable for 125/150/ 250/400 watt
S&F in repairs capacitor 18-25 mfd suitable for HPMV light fitting suitable for 400 watt
S&F in repairs capacitor 10-20 mfd suitable for HPMV light fitting suitable for 250 watt.
S&F in repairs capacitor 10-20 mfd suitable for HPMV light fitting suitable for 150 watt.
S&F in repairs capacitor 10-20 mfd suitable for HPMV light fitting suitable for 125 watt.
S&F in repairs open construction heavy duty VPIT copper wound ballast for 400 watts.HPMV lamp
S&F in repairs open construction heavy duty VPIT copper wound ballast for 250 watts.HPMV lamp
S&F in repairs open construction heavy duty VPIT copper wound ballast for 150 watts.HPMV lamp
S&F in repairs open construction heavy duty VPIT copper wound ballast for 125 watts.HPMV lamp
S&F in repairs Tubular bulb/lamp suitable for 400 watts HPMV light fitting ,including taking down existing bulb all as directed
S&F in repairs lamp suitable for 250 watts HPMV light fitting ,including taking down existing bulb all as directed
S&F in repairs Tubular bulb/lamp suitable for 150 watts HPMV light fitting ,including taking down existing bulb all as directed
S&F in repairs Tubular bulb/lamp suitable for 125 watts HPMV light fitting ,including taking down existing bulb all as directed
BRO TECH ELECTRICAL & ENGINEERING SOLUTION (BID ID -3114295)
HARSHITA MARINE SERVICES (BID ID -3112060)
PEGASOS ENGINEER TRADERS (BID ID -3105915)
N P ENGINEERINGS (BID ID -3114876)
M/S. NAVEEN ENGINEERING & CO (BID ID -3107576)
JAI SHREE GOPAL ELECTRICALS (BID ID -3111702)
M/S VERNEKAR AGENCIES (BID ID -3116115)
SIRI SALES AND SERVICES (BID ID -3114701)
SHRI MALLIKARJUN BATTERY AND ELECTRICAL WORKS (BID ID -3114885)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .