| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.9 CrAccepted-AOC NH 6 RAKHAJUNGLE SADATPUR PASCHIM MEDINIPORE WEST BENGAL 721304 | MEDINIPUR WEST | WEST BENGAL | 721304 | ₹1.9 Cr Quoted ₹2.0 Cr | 1 | Accepted-AOC BEING L1 |
| 2 | 2₹2.0 Cr+₹5.4 L (2.75%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹2.0 Cr+₹5.4 L (2.75%) | 2 | Rejected-Finance BEING L2 |
| 3 | 3₹2.2 Cr+₹23.0 L (11.7%)Rejected-Finance B XI 746 STREET NO 6 BHARAT NAGAR BARNALA 148101 | BARNALA | BARNALA | PUNJAB | 148101 | ₹2.2 Cr+₹23.0 L (11.7%) | 3 | Rejected-Finance BEING L3 |
| 4 | 4₹2.2 Cr+₹23.9 L (12.2%)Rejected-Finance | ₹2.2 Cr+₹23.9 L (12.2%) | 4 | Rejected-Finance BEING L4 |
| 5 | 5₹2.2 Cr+₹26.2 L (13.4%)Rejected-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | ₹2.2 Cr+₹26.2 L (13.4%) | 5 | Rejected-Finance BEING L5 |
Tender Value
Refer Docs
EMD Value
₹3.2 L
Closing Date
9 Aug 2023, 6:00 pmClosed
CWE PATIALA
HQ COMMANDER WORKS ENGINEER BLDG No 26 NEW LALBAGH PATIALA 147001 Contact 01712200082
SPECIAL REPAIR ADDITION ALTERATION OF KENDRIYA VIDHYALAYA NO 1 PATIALA CANTT BUILDING AT PATIALA MILITARY STATION UNDER GE NORTH PATIALA
2023_MES_609914_1
CWE/PAT/T-23/2023-24
Open Tender
Civil Works
Works
545 days
PATIALA
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
GE NORTH PATIALA
₹3.2 L
24 Aug 2023
20 Jul 2023
11 Aug 2023
20 Jul 2023
9 Aug 2023
3 Aug 2023
20 Jul 2023 - 2 Aug 2023
Amount
Taking down cement plaster on brick Walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Rendering 15mm thick i in cement mortar 1:4 including mixing of liquid water proofing compound of approved make as per manufacturer's instructions on fair faces of brick work or concrete surfaces or in chajjas / parapet walls etc finished even and fair without using extra cement complete all as specified and as directed. Note : WPC will be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed
10mm thick cement plastering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
5mm thick cement plastering in CM 1:3 on fair faces of concrete ceiling surfaces finished even & smooth wihtout using extra cement complete all as specified and directed.
Material & Labour for preparation of newly plastered or unplastered surfaces of wall applying two coat of distemper oil emulsion white/tinted with 1mm thick wall care putty finished surface complete all as specified and directed by Engr -in - charge.
Material & Labour for preparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed by Engr -in - charge.
Roughening surfaces of old concrete floor/wall by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engr -in - charge.
Material and Labour for 20mm thick screed bed in CM 1:6 for laying floor finish all complete all as specified and as directed.
Material and Labour for 25mm thick, PCC 1:2:4, type B-0 (using 12.5mm graded stone aggregate), as in floor, sub base finished fair & even without using extra cement complete all as specified and directed .
Material and Labour for full body, vitrified, stain & scratch resistant, joint free, premium quality coloured tiles 600 X 600 mm and 8-10 mm thick, as in floors/skirting etc. in any pattern of light & dark tiles as approved, set and jointed with adhesive of Sika (Ceram Grey) @ 5 Kg/sq.m or equivalent as approved by GE and pointed in white or coloured cement to match, in floors etc. complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding, removing serviceable tile to store and rubbish off the premises complete all as specified and directed.
Material and Labour for Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles, complete all as specified as directed by Engr-in- Charge
Material and Labour for Virified Ceramic tiles 8-10 mm thick dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with pigment to match the colour of tiles complete all as specified.
Material and Labour for Virified Ceramic tiles light shade 8-10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colour of cement to match the coloured of tiles complete all as specified.
Material and Labour for Vitrified ceramic coloured (colour & shade as approved ) tile of size 600x100x10 mm thick as on vertical surfaces such as skirting/ dado etc length of each tile not less than 600 mm , set and jointed in cement slurry over and including 10 mm thick rendering in cement mortar(1:4) and pointed in white/ coloured cement with pigment to match the colour of tiles complete all as specified.
Material and Labour for Glazed ceramic tiles (coloured tiles) in vertical surface 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick rendering in CM 1:4 on other than fair face of brick work all as specified and directed.
Dismantling loose/disintegrated portion of RCC Chajjas, bands, shelves, beams, column or slab and similar work including support if required and stitching of cracks with MS U clamps of 8mm dia @ 150mm c/c with inserting concrete block strengthed with cement mortar 1:3 mixed with adhesive chemical (polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with 10mm thick plastering in CM 1:4 finished even & smooth without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed.
Taking down chowkhats or frames of any description exc 1.5 Sqm but n. exc. 4 sqm each (without taking off shutters from the frame) including cutting hole to size for receive fresh PCC of hold fast and making good the disturbed surface complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frame) not exc 1.5 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified.
Supply & Fix Solid PVC Double door frame of size 50mm x 95mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. tube, suppling & fixing in opening as per specification complete all as specified.
Supply & Fix Factory made Solid PVC Moulded Door Shutter, with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Wood grain laminated & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification all as specified and directed
Material and Labour for Powder coated (Minimum thickness of powder coating 50 micron) Anodised aluminium frame, shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engr-in-Charge.
Supply & Fix 12 mm thick high density fibre board pre-laminated in both sides (water proof) below & above middle/lock rail in powder coated aluminium doors and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc aluminium beads 20mm size with and complete all as specified and directed by Engr-in-Charge.
Supply & Fix 4mm thick tinted glass fixing in aluminium door/ window including rubber gasket & beading complete all as specified and directed.
Supply & Fix 125 mm long butt hinges, medium weight, cold rolled, mild steel and fixed all as specified
Supply & Fix 150 mm long Aluminium handles cast type anodised all as specified
Supply & Fix 200 mm long Aluminium anodised barrel tower bolts of extruded section and fixed all as specified
Supply & Fix Mild steel sliding door bolt 300 mm long plate type stove enamelled black with bright bolt not less than 12mm dia with & including a minimun of 6 bolt nuts four on bolt plate and two on staple plate fixed complete all as specified & directed by Engineer-in-Charge.
Supply & Fix floor door stopper of aluminium body overall length of cover plate 40mm fixed all as specified & directed
Material and Labour for taking down Shutter of any description exc 1.0 sqm but nexc 2.0 Sqm each all as specified
Supply & Fix Pressed steel frames made of MS sheet of 1.20mm thickness of size 105 x 60 mm for doors with single or double rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts etc complete all as specified. (Note :- Distrubed portion of existing floor/ wall/ tile/ plaster etc during fixing of chowkhats shall be repaired to match with exisitng finish. Cost of the same will be included in this items).
Material and Labour for PCC 1:3:6 type C-0 using 12.5 mm graded stone aggregates as in padding over roof/hold fast filling inside frame & hold fasts etc complete all as specified
Material and Labour for preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified.
Supply & Fix Flush shutters 30mm thick, solid core construction, with particle board core and plywood face panels, commercial type on both sides all as specified & directed.
Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed all as specified & directed.
Demolition of Cement Concrete as in ground floor & paving n. exc. 15cm thick (above or below G.L.) all as specified & directed.
Plain cement concrete 1:7:12 mix, type E-2 (using 40mm graded Brick aggregate) as in filling of sunken portion complete all as specified and directed.
Rendering 15 mm thick in cement mortar 1:3 , mixed with water proofing compound, on brick or concrete surfaces of wall of sunken portion , trowelled to even and fair finish with WPC paid and measered seprately complete all as specified.
Providing 40 mm dia GI pipe medium grade spouts 60 cm long complete all as specified and directed.
Supply & Fix stainless steel tubing of 25 mm dia chromium plated mininum 1.0 mm wall thickness as in curtain rod complete including Supply & Fix 02 Nos stainless steel brackets/finials fancy type, stops fixed with stainless screws etc all as specified & directed as in repair . Note : For the purpose of measurement and payment running length of curtain rod only shall be considered.
Supply & Fix Vitreous china squatting pan, 'Orissa' pattern, size 580x440 mm white, with integral foot rests, CI 'P' or 'S' traps 100mm & PVC flush pipes 32mm dia including connecting to trap and to flushing pipe, anti-syphonage pipe etc including all joints and making good to floor all as specified
Supply & Fix vitreous china premium/1st quality wash down water closet wall hung EWC P trap white/ivory/off white including connection to drain (or out going pipe) and to flushing pipe, anti syphonagee pipe etc.with flushing pipe PVC 32mm dia and including plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc. and including all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing including 100mm dia cast iron sanitary connections, short connections pipe of length upto 600 mm and Cutting holes in or through walls, packing with PCC 1 : 2 :4 complete and taking down existing of any description/size complete in all respect all as specified.
Supply & Fix in repair PVC 10 litre capacity valve less syphonic action type, flushing cistern, low level, white/coloured with inlet ball valve, float, PVC bend and handle including brackets, etc. complete all as specified by Engineer in Charge.
Supply & Fix Vitreous China Urinal, half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including flat back ,white (min) with grating and union for discharge pipe including waste pipe etc. complete all as specified and directed
Supplying and fixing in repairs 15mm dia chromium plated brass, auto closing urinal valve complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs Vitreous china urinal partition white of size 310x700mm, complete all as specified and directed by Engineer-in-Charge
Supply & Fix vitreous china premium/1st quality wash basin (counter top), white/ivory/off white, size 580x430 mm including Supply & Fix all accessories as recommended by manufacturer incl. CP bottle trap 32 mm with inlet and outlet screwed for pipe or connections incl all necessary accessories for fixing, packing, union and incl 32mm brass CP waste coupling and complete fixed in position in all respect as per manufacturer's instructions and taking down existing WHB of any description/size all as specified. Note : The items for counter will be measured and paid separately.
Formwork to soffits of suspended slabs such as roof slabs,floor slabs,landings and similar work, not exceeding 200 mm thick all as specified
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as specified and directed
Material & Labour for nominal mix 1:2:4 type B0 using 12.5mm stone aggregate for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
Supply & Fix in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engineer in Charge.
Supply & Fix sinks with drainage board made of stainless steel 0.80 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm all as specified.
Supply & Fix in repair white ceramic laboratory sink of size 600x450x250mm including waste fittings and all accessories as specified and directed by Engineer-in-Charge
Dismantling old unserviceable cement concrete/PVC water tanks of capacity exc 500 ltrs & n.exc 1000 Ltrs including supplying & fixing of PVC water storage tank 1000 ltr capacity HDPE triple layered ,white colour cylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20 mm GI Pipe connection incl locking arrangement, including supplying & fixing of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia and (Minimum weight 20 mm - 210 gms ) fixed as in repairs. Note : (i) Inlet, outlet & wash out pipe will be measured paid for separately.
Supply & Fix stainless steel plate rack of size 900x750x250mm made out of 1.0mm thick stainless steel sheet of first quality fixed in wall using stainless screws complete all as specified and directed by Engr-in-charge
Supply & Fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Supply & Fix Roof trusses (framed),(Fe 410-W (Gde-E-250 quality -A) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.all as specified.
Preparation of new surface of steel and applying two coats of synthetic enamel paint over a coat of red oxide on surfaces of any description, over 10 cm in width or girth not otherwise described as in truss complete all as specified and as directed.
Material & Labour for preparation old painted steel surface any description over 10cm width or girth not otherwise described and applying one coats of synthetic enamel paint complete all as specified.
Material & Labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:4 all as specified
Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified.
Demolition of mud phuska on roof any thickness incl plastering and leeping all as specified and directed.
Material & Labour for wire brushing, cleaning top surface ,Scarping surfaces of roof by wire brushing and removing all loose dust and cleaning and washing down the surfaces with water complete all as directed.
Providing and laying 3mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 3.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including on a coat of bitumen primer @ 0.40 ltr/sq.m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps Over the coat, 3mm thick 5 layered APP membrane shall be laid using butane torch and sealing all joints etc after the surface complete as per standard practice as per manufacturers instructions. The vital physical and chemical parameters of the membrane shall be as under - (i) Joint strength in longitudinal and transverse direction at 23 degree C as 650/450N/5cms (ii) Tear strength in longitudinal and transverse direction as 300 / 250 N. Softening point of membrane not less than 150 degree C Cold flexibility upto 20 degree C when tested in accordance with ASTM (D05147)
Material & Labour for 15 mm thick screed bed in CM 1:4 for laying floor finishes with WPC (paid and measered sepretaly) complete all as specified and directed by Engr-in-Charge.
Supply & Fix factory made, un-reinforced precast cement concrete tiles of area exe 0.06 but not exc 0.09 sqm each, 22mm thick with grey cement and no pigment of machine pressed, as on roof surface, confirming to IS 1237-1980, incl set, jointed and pointed with grey cement and no pigment slurry complete all as specified and directed.
Material & Labour for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregates) as in roof kerbs, benches and water troughs etc. including necessary moulding complete all as specified & directed.
Taking up or down 15mm dia GI Tubing and connection or removal to store complete all as specified..
Taking up or down 20mm dia GI Tubing and connection or removal to store complete all as specified..
Supply & Fix 15mm bore GI tubing medium grade with all fittings fixed to walls or laid in floors complete all as specified.
Supply & Fix 20mm bore GI tubing medium grade with all fittings fixed to walls or laid in floors complete all as specified.
Supply & Fix 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed as specified
Supply & Fix 15mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed as specified & directed
Supply & Fix in repair 15mm angle cock/ stop cock with flange cast copper alloy, chorminium plated, fancy type, screwed both ends for iron pipe or for union complete all as specified and directed by Engineer in Charge.
Supply & Fix in repair 15mm bib taps, fancy type cast copper alloy CP with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified by Engineer in Charge.
Supply and fix WHB Mixer valve for mixing hot and cold water of Brass Chromium Plated screwed down for 15mm dia iron pipe including taking down complete all as specified and directd by Engineer-in-Charge. Note: The quoted rate shall include the long braided hoses 450mm long for connection to mixer complete.
Dismantling CI/PVC pipe alongwith fittings of 75/100mm dia,below or above GL, laid in floors or fixed to walls jointed in cement mortar and taking out complete all as specified
Supply & Fix 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors as specified and directed
Supply & Fix PVC (SWR) bend any radius 110 mm bore as specified and directed
Supply & Fix 100mm dia cast iron soil, sand cast pipes, waste and vent pipe, in any length with or without ears with cement joints laid in trenches, in floors or fixed to walls as specified and directed
All as per Item No 81 here in before but 75mm bore pipe complete all as specified.
Supply & Fix in 100 dia CI bends, diminishing pieces or tapers all as specified
All as per Item No 83 here in before but 75mm dia all as specified.
Supply & Fix in repairs CI Floor trap long neck 75 mm dia, with stainless steel grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) etc fixed in repairs.as specified and directed
Supply & Fix branch pieces, 100mm dia, single (equal or unequal), ordinary of inverted (spigot or socket type) or with parallel branches as specified and directed
Supply & Fix branch pieces, 75mm dia, single (equal or unequal), ordinary of inverted (spigot or socket type) or with parallel branches as specified and directed
Supply & Fix 75mm cast iron vent cowls as specified and directed
Supply & Fix in repairs CI Floor trap long neck 100 mm dia, with stainless steel grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) etc fixed in repairs.as specified and directed
Supply & Fix 6mm thick looking mirror with smooth finish bevelled edges/sides fixed to wall with stainless steel brackets/plugs/connecter/spacers/ screws etc. chrome finish with PVC back 5mm thick complete fixed in position all as specified and directed.
Supply & Fix in repair Towel Rail 450mm long of CP fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms) as specified and directed
Supply & Fix gypsum board 8-10mm thick in ceiling fixed with screws as per manufacturer instructions plain/ colour fixed with steel snap grid (powder coated bottom side) with T and L (25mm*30mm*1mm thick) section of size 600mmx600mm placed in ceiling L section fixed with wall with PVC rawal plugs and steel screws @600mm centre to centre and suspended/provided 5mm dia galvanised bar @1 sqm hanging arrangement and levels incl adjustable clips, complete all as specified in clause 10.38 of schedule part-1 complete all as specified (Note- if any minor electrifical and fixtures distributed there in will be match and fixed as existing) as specified and directed
Supply & Fix false ceiling of 12.5mm thick gypsum board over and including concealed grid system complete fixed in all respect and all as per manufacturer's instructions in one/two/three levels and making recess for light fittings as per pattern/design approved by Accepting Officer and including supply and fixing of items all as specified as below :- (a) Suspended Plain Ceiling includes Perimeter Channel {Material-GI(IS513),YS-260Mpa,Finish- Galvanised 150GSM(IS27 )} is fixed along the perimeter of existing wall/ partition with the help of HILTI HPS - 1 (6x40) impact anchor, at 600mm centres. (b) Ceiling Angle {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is suspended by fixing it to the Gyproc® soffit cleat {GI(IS513)YS-260Mpa,Finish-Galvanised 150GSM(IS277) }. Soffit Cleat and Gyproc® Rawl Plug- Ø8x45mm {Material-IS 513 CR2 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} creating 1220mm x 1220mm grid. (c) Intermediate channel {Material-GI(IS513),YS-260Mpa, Finish-Galvanised 150GSM(IS277) } is fixed to the Ceiling Angle with M6 x 12mm Hex Bolt & Hex Nut arrangement {Material–As per EN 10083 Finish – Zinc Plating} or with 2 Nos of Ø4.2x13 Gyproc® metal to metal screw {Material-Carbon steel EN-ISO 7049/50 Finish- Zinc Coating Thickness- 4.14micron.} (d) Ceiling Section {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is then fixed to the Intermediate Channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} with the help of Gyproc® Connecting Clip {Material-High carbon spring steel wire(BS970Gr.En42)-46-48HRC,Finish- Zinc plating 4-6 micron} and in direction perpendicular to the Intermediate channel at 457mm c/c. (e) Single layer of 12.5mm tapered edge Plain (conforming to IS 2095-Part 1:2011, ISI Certified board) is then screw fixed to ceiling section with 25mm drywall screws {Material-Carbon steel EN-ISO 7049/50,Finish-Case hardened Grey Phosphating} at 230mm centres on ceiling section & 150mm at periphery of ceiling. (f) Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Pro-Fill Jointing compound (Conforms to ASTM C475), Gyproc® Joint Paper tape and applying 02 coats of interior emulsion over a coat of wall care putty including a coat of primer all as specified. Note : The complete item shall be got executed through the authorised applicator of manufacturer only all as specified and directed.
Supply & Fix PVC hollow Wall panelling of section sizes 150x10 mm (colour/pattern as approved by Accepting Officer) complete fixed in position in all respect including supply and fixing of all accessories like fasteners/screws/solvent etc all as recommended by manufacturer all as specified.
Material & Labour for Granite 16-18 mm thick work (of any type) (table rubbed and polished) in cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including nosing edges and chamfered complete all as specified
Excavation over areas, n exc 1.5 m deep and getting out all as specified & directed
Excavation in trenches, n exc 1.5 m wide depth & getting out all as specified & directed
PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundations all as specified & directed
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter all as specified & directed
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for Rough finished for concrete surfaces all as specified & directed
Mild steel (TMT bars) bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips alla as specified & directed
Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed
Material & Labour for nominal mix 1:2:4 type B0 using 12.5mm stone aggregate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified & directed
Material & Labour for nominal mix 1:2:4 type B0 using 12.5mm stone aggregate for Columns, pillars, piers, posts and struts all as specified and directed
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of floor or the side of waist slab with suitable arrangement including name of any size of board all as specified & directed
Material & Labour for 20 mm thick Marble, white colour machine cut, in skirting, riser of stair in screed bedded jointed and pointed with white cement slurry including cutting and polishing, types all as specified & directed
Material & Labour for 16-18mm thick Dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone size exceeding 0.5 sqm area fixed in vertical wall or column with and including one number SS clamps (grade - 202) of flat-30mm X 2mm, 150mm long made to shape in each slab, making V groove at top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment all as specified and directed
Material & Labour for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and ornamental type (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing completeFe 410W (Gde- E- 250) quality-A Fe- all as specified & directed.
Material & Labour for ACP sheet of 4 mm thickness of approved plain colour/ shade for chajjas/ sunshades/ cladding and the like works etc. fixed to frame work of MS/ Aluminium/ Hollow sections of any size description including finishing all the joints with silicon or as per manufacturers instructions complete in all respect and complete fixed in position incl scaffolding/ ladders etc as required and also making the joint between all as specified and directed. Note : Frame work shall be measured and paid separately
Material & Labour for 4 mm thick exc 0.05 sqm in each pane Sheet glass , ordinary quality and glazing with oil putty in square fixed in repairs all as specified & directed
Complete removal of existing treatment of any type/ description such as distempering work, internal surfaces of old walls & ceiling with mechanical means/ dust free grinder complete all specified and directed
Applying 02 coats of interior emulsion paint (white shade) @10 sq.m/litre/2coats by using roller to wall surfaces over & including a coat of interior wall primer @10 sq.m/litre/1 coats as recommended for under coat by manufacturer of interior emulsion including acrylic thick wall care putty 1.5 to 2.5 mm thick complete all as specified and directed.
Applying 02 coats of interior emulsion paint (white shade) @10 sq.m/litre/2coats to ceiling surfaces over & including a coat of interior wall primer @10 sq.m/litre/1 coats as recommended for under coat by manufacturer of interior emulsion by using including acrylic thick wall care putty 1.5 to 2.5 mm thick complete all as specified and directed.
Material & Labour for 18 mm thick with minimum density 600 Kg/cu.m LEAD FREE PVC Celuka ply of both side plain white colour fixed with screws, solvent cement/ adhesive to make kitchen/bed rooms cabinet sides top and bottom and shelves inside the cabinets complete as per manufacturer’s specifications complete all as specified and directed.
18 mm thick with minimum density 600 Kg/cu.m LEAD FREE PVC Celuka ply of single rigid laminated of approved colour and other side plain white colour fixed with screws and solvent cement/ adhesive to make kitchen cabinet shutter and shelves complete as per manufacturer’s specifications complete all as specified and as directed.
Material & Labour for piano/ contineous hinge of size 19 mm stainless steel bright finish complete in all respect and fixed in position all as specified.
Material & Labour for D-type cabinet handles premium quality, stainless steel 304/ gloss chrome/ SN finished 200mm long matt finished complete fixed in position all as specified.
Material & Labour for coloured chequred cement concrete tiles 30 cm x 30 cm x 20mm thick, made of grey cement set and jointed in neat cement slurry with grey cement and pigments as in floors to match the shade over screed bed or bedding layer or mortar 15mm thick in cement mortar 1:4 for laying floor finished, complete all as spcified and directed. .
Material & Labour for washed stone grit plaster on exterior walls in two layers, under layer 12mm thick in cement plaster 1:4 (1 cement: 4 coarse sand) over and including binding of chicken wire mesh with existing reinforcement after furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3Kg of cement plaster 1:1/2:2(1 cement : 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chipping including taking down existing cement plaster complete all as specified and directed.
Taking down carefully existing points wiring on surface conduit/concealed conduit for light/ fan/ socket/ power/ bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion of all floor, ceiling etc all as specified and directed.
Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green etc colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Galvanised iron sunken terminal box (Min 1.6mm thick sheet, Min 60mm deep, suitable size) concealed in wall, including 3mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches, socket shall be measured and paid separately under appropriate item of BOQ/Sch 'A') (Wiring shall be done as per colour code in IS for phase, neutral and earth) (In case of Modular switches: Modular cover plate and metal flush boxes included in Point wiring)
All as Ser Item No 121 here-in-before but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed cable 1100 volt grade and 1.5 sqmm PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
All as Ser Item No 121 here-in-before but one 5Amp socket point on independent board but with other switches complete all as specified and directed.
All as Ser Item No 121 here-in-before but one 5Amp socket point on independent board but with other switches complete all as specified and directed..
Material & Labour for modular switch 1 way 6 A, 1 module complete all as specified and directed.
Material & Labour for modular socket, 6A-2/3 pin combined, 2 module.complete all as specified and directed.
Material & Labour for modular switch 16 Amps, 1 module with indicator complete all as specified and directed.
Material & Labour for modular socket 16 Amps, 6 pin, 2 module complete all as specified and directed.
Material & Labour for fan regulator electronic type 5 speed modular type 2 module complete all as specified and directed. complete all as specified.
Supply and fixing ceiling rose (ISI marked) surface type polycarbonate isolated body two to three terminal, topline series 20x50mm, 6 Amp, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 40x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting with old bracket any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing recessed LED ceiling mounted with wide light window for maximised glare free output suitable for 600x600mm and ceiling cutout 595x595mm modular grid/POP ceiling finishes complete fitting with separate electronic driver and high brightness LED 36 Watt, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from connector/ceiling rose to light fitting, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP20. (g) CCT : 6500K (h) CRI : Minimum 80 (j) CRCA pre coated housing. (k) LED Driver of the make as of the luminaire. (l) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Surge protection minimum 3 kV. (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED batten fitting complete tube polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear LED lighting fixture with CRCA housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with coloured plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply & Fix MCCB DB TPN 4 Way vertical type bus bar capacity 125 Amp factory made 415 volts IP 43 protection class metal double door with Shrouded Neutral Bar & Pan assembly with connecting link complete including one MCCB upto 125A after dismantling old one complete all as specified and directed.
Supply & Fix MCCB DB TPN 4 Way vertical type bus bar capacity 200 Amp factory made IP 54 protection class metal double door with Shrouded Neutral Bar & Pan assembly with connecting link complete including one MCCB upto 125A 415 volts after dismantling old one complete all as specified and directed.
Supply & Fix MCCB 63 Amp 16 KA 4 pole or fixing in DB complete all as specified and directed.
Supply & Fix MCCB 125 Amp 25 KA 4 pole for fixing in DB complete all as specified and directed.
Supply & Fix Single pole & neutral 8 way door closer DB with 200 amps rated bus bar.compelete all as specified and as directed.
Supply & Fix MCBs 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB. (DB will be measured and paid separately under respective items of BOQ):- (a) MCB SPN 40 Amps.
(b) MCB SP 6 to 32 Amps
(c) MCB SP 40 to 63 Amps
Supply and fixing for sub main wiring Four single core PVC insulated and unsheathed FRLSH cable with 10 Sqmm multi -strand copper conductor drawing in PVC concealed conduit of suitable size with 10 Sqmm 2 single core PVC copper conductor cable as in earth wire system, including taking out old wiring complete all as directed. Note 1: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost 2. All copper wires must be connected to DB's WITH PROPER SIZE COPPER THIMBLES.
Supply and fixing for sub main wiring with two single core 6 Sqmm PVC insulated and unsheathed FRLSH,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia incl 6.0 Sqmm PVC insulated unsheathed FR stranded copper conductor cable as earth wire all as specified and directed. Note 1: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost. 2. All copper wires must connected to DB's WITH PROPER SIZE COPPER THIMBLES.
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed FRLSH cable with 4 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 4 Sqmm PVC copper conductor cable as in earth wire system, including taking out old wiring complete all as directed. Note 1: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost. 2. All copper wires must connected to DB's WITH PROPER SIZE COPPER THIMBLES.
Supply and fixing earth metal plug and socket single pole and neutral with a two pin and earth plug and socket alongwith one single pole MCB of 20 Amp concealed in wall all as directed by Engineer-in-charge.
Supply and fixing Earth continuity conductor 4 mm dia main lead fixing to wall on batten or recced or chase or buited in ground or drawing in coduit/pipe or fixed to poles or any other indicated situations for loop earthing complete all as specified and directed.
Taking down ceiling fan and refixing after neccery cleaning complete all as specified and directed.
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V, min air delivery 220 CFM), with 5 star service value, single phase, minimum 30W (± 10%), Temperature rise 40 degree maximum, with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Taking down Exhaust fan and refixing after neccassery cleaning complete all as specified and directed.
Supply and fixing Ceiling fan down rod 3/4 feet of suitable dia compelete all as specified and as directed.
Taking down LED tube light fitting 18/20watt and refixing after neccassery cleaning complete all as specified and directed.
Dismantling/taking down window type AC 1.5/2 Ton from site, opening and reinstalling AC in the same Location after repair work complete all as specified and as directed.
Dismantling/ taking down Split type AC 1.5/2 Ton from site, opening, cleaning and reinstalling AC in the same location including gas charging fitting with suitable size copper pipe line and flair nuts of same size both unit outdoor/indoor unit complete and testing on full load etc after repair work complete all as specified and as directed.
Supply & Fix Prestressed concrete pole, 11.0 metres long, 152mm x 152mm at top and 152mm x 260mm at bottom class 9 for making two pole structure complying with requirement of relevant IS and including marking alternate RED and BLACK strips 30 cm high each , total of 8 Nos , commencing from the top of PCC coping with two coats of synthetic enamel paint over a coat of primer and writing pole Nos (letters and figures) (Block, Roman, Italic or Indian) of size as directed with synthetic enamel paint complete all as specified and directed. Note:Earth work, PCC, GOD, MS work etc shall be measured and paid seperately under relevant items.
Plain Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 and applying two coats of white wash to the portion of PCC muffs above ground level complete all as specified.
Plain Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar applying two coats of white wash to the portion of PCC muffs above ground level complete all as specified.
Plain Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar applying two coats of white wash to the portion of PCC muffs above ground level complete all as specified.
Supply and replace switch gang operated, triple pole with drop out fuses, mechanically operated, mounted on fifteen (15) insulators and steel frame with operating mechanism and operating rod of GI tubing 25 mm bore medium grade with necessary clamps, to be operated from ground level 11000 volts grade working pressure and current rating up to 200 amps complete all as specified and directed.
Material & Labour for Cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections incl nuts, bolts, washers, welding, bending cold or hot,, drilling holes for bolts in any shape or size as indicated or directed and inclusive or one primer coat, one under coat and one finishing coat of super enamel paint complete all as specified and directed.
Supply and fix lightning arrestor 11 KV(rms) having discharge capacity 65 KA, “POLYMERIC HOUSING” including necessary connections with HT over head lines complete all as specified and directed.
Supply , installing, testing and commissioning of outdoor type step down transformer 11000/433 volts (at no load), AC, 3 phase 50 Hz, copper wound type complete with standard fittings, 11 KV 3 phase , LT 433 volts, 3 phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS: 1180 (with latest amendments) of capactiy 400 KVA, core type copper wound, oil immersed, naturally cooled, oil nature, air nature (ONAN) with external cooling tubes/ fins delta connected on primary side (HV) and star connected on secondary side(LV) in accordance with vector symbol DYN-11(Vector group) with neutral brought out on secondary side (LV side ) and having tapping at ±5%HV side to be changed by means of hand operated off load tap changer gear. The maximum temparature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temparature of 40 degree celsius. The transformer shall be IS 1180 marked energy efficient level 2 and shall comprise of the following :- (a) 3 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV complete with bushing,copper rods, nut and washers. (b) One cable box on LT side (secondary side ) consisting of 04 No of porcelain bushing with copper rod, complete with nuts and washers with two numbers cable glands suitable for reception /taking out of XLPE insulated heavy duty armoured cable including glands, joints and jointing material complete. (c) Oil conservator with filter type drain valve and oil level gauge (d) Dehydrating breather with first fills dehydrating agents (silica gel) (e) Explosive vent (f) Thermometer pocket on tank cover (g) One number 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsious wth metal guard having max perimeter reading tempreture indicator with resisting device for transformer (h) Two earthing terminal on tank cover to facilitate fixing of 32x6 mm GI earth strip for earhting of neutral and body
(j) Rating plate and terminal marking plate (k) Oil level gauge (l) Oil drain filter valve (m) Lifting lugs (n) Oil filling holes with cap/ plug with connecting plate complete (o) Air release plug (p) Four plain solid cast steel detachable rollers (q) Extra bushing for neutral, outside LT cable box for proving independent earthig for neutral (r) First filling new and unused transformer oil IS-335/93 (forth version) marked (make -HP/power oil or equivalent as approved by GE) filtered and tested dielectric strength at 2.5 mm air gap between testing electrode asper IS 335. Note: Certification of di electric strength shall be submitted by the cotractor after filling the oil. The transformer shall be got tested from SEI before commissioning. the cost of all tghe above provisions is deemed to be included in the unit rate quoted by the contractor.
Supply and laying or fixing or laid in trenches/ ducts / under roads/ hard standing /along poles and testing HT cable XLPE, insulated and PVC sheathed screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 11000 (E) volt grade with stranded aluminium conductor having cross sectional area 95 Sqmm 3 core conforming to IS-7098 (Part-II -2011) with upto date Amendments complete all as specified and as directed. Note ;- Excavation and earth work, sand cushioning, Protection cover & protection pipe shall be measured and paid separately under respective item of BOQ.
Material and Labour for fixing Steel tubular swaged poles type 410 SP-31 (9.00mtr long) complete with cast iron base plate, finial, taper plug, bolts nuts & screws complete all as specified including internal surface of steel tubular pole through out and external surface up to planting depth shall be painted with bituminous paint and remaining external surface shall be treated with two coats of aluminium paint over a coat of red oxide zinc chromate primer complete and painting upto 1.5 mtr with alternate layer of yellow & black including marking Sr No of the poles all as specified. Note:- Necessary earthwork and cement concrete work shall be measured and paid seperately in BOQ items.
Supply and fixing energy efficient LED street light fitting of 60W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x4 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, including electric connection, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting any type with old bracket complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : Minimum IP65. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily).
Supply & Fix PVC insulated and sheated copper conductor of size 1.5 Sqmm 3 core from junction box to street light fittings complete all as specified and directed.
Supply & Fix Cable jointing kit for 11 KV (Earthed) grade cable for OUTdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70- 120 sqmm complete all as specified.
Material & Labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.30mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 32X6 mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3.5:6 type c1 with PCC cover and, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as directed.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI medium grade pipe upto test point or upto electric equipment, fixing with 02 Nos nuts and bolts. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) including taking out/dismantling old unserviceable earthing system complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing of GI tubing light grade of 80 mm dia for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc all as specified and directed.
Supply and fixing of GI tubing light grade of 50 mm dia for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc all as specified and directed.
Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 300 Sq mm 3.5 Core complete all as directed.
Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 240 Sq mm 3.5 Core complete all as directed.
Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 150Sq mm 3.5 Core complete all as directed.
Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70Sq mm 3.5 Core complete all as directed.
Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 50Sq mm 3.5 Core complete all as directed.
Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sq mm 4 Core complete all as directed.
Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sq mm 4 Core complete all as directed.
Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 Sq mm 2 Core complete all as directed.
Supply and fixing gun metal test point terninal block of size 75 x 75 x 25 mm drilled and screwed inlcuding 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and directed.
Material & Labour for taking out concrete poles/struts, any size and taking safe custody of MES store yard complete all as specified & directed by Engr-in-charge.
Material & Labour for taking out concrete poles/struts, any size including taking down of OLD/US LED street light from the PCC poles and taking safe custody of MES store yard complete all as specified & directed by Engr-in-charge.
Dismantling/Taking down old ACSR conductor from LT pole by opening all connections complete all as specified & directed by Engr-in-charge
Material & Labour for taking out concrete TWO pole structure of GOD system, any size including taking down of all insulators and switching system from the PCC poles and taking safe custody of MES store yard complete all as specified & directed by Engr-in-charge.
Supply & Fix 120 watt LED Flood light luminaire of epoxy powder coated CRCA MS housing with epoxy powder coated aluminium heat sink with system wattage, with 120 degree view angle,>100 lumen/watt,luman maintenance>90% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,reverse polarity protection,high voltage protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.The LED used in fitting is of same manufacturer.
Excavation in trenches soft/loose soil n.exe 1.5 mtr wide and not exc 1.5 mtr deep for laying of cables including taking down complete all as specefied and directed.
Returning filling in of layers including spreading, leveling complete all as specefied and directed.
Removing surplus spoil to a distance not exceeding 50 m and depositing where it is directed complete all as specefied and directed.
Material and labour for precast concrete cable covers class class HV, type 1 with peak, size 300mm x 180mm x 40mm laid dry in trenches for cable protection all as specified and directed by Engineer in Charge.
Material and labour for precast concrete cable covers class class LV, type 1 with peak, size 250mm x 150mm x 40mm laid dry in trenches for cable protection all as specified and directed by Engineer in Charge.
Material and labour for sand cushioning, with dry and clean fine river sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. (Note:- Punned thickness shall be considered for payment purpose)
Boring of horizontal holes by manually without disturbing the top surface (trenchless) under road, pavement, hardstanding suitable for inserting GI pipe any dia upto 80mm including removal of surplus soil and making good disturbed surface complete all as specified and as directed. NOTE:- Pipe for inserting as required shall be measured and paid for separately.
Material & Labour for providing platform for placing of Transformer size of 3.0 x 2.5 mtr with height of 900mm above GL and 300mm below GL with PCC 1:2:4 type B1 using 20mm stone aggregate as in foundation and platform including necessary flat angle iron 40x6 mm and XPM for fencing around the transformer for safety.all as specified and directed by Engineer in Charge.
Supply, Install, testing and commissioning LT feeder pillar BUS BAR BOX of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board IP 54, insulated with PVC sleaves and coloured with (red, yellow, blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use fitted on angle iron 25x25x6 mm frame of the panel board, thimbling and cable entry boxes with cable gland and the copper bus bar should be 400AMP Capacity all as specified and directed by Engineer in Charge.
Supply and Fix Standalone All -in-One LED Solar Street Light Fittings 36 Watt, high efficacy LEDs 120 lm/watt, Silicon encapulated high efficiency MPPT Charge controller with dusk down sensor, uniquely designed extruded aluminium housing with IP-66 protection for better heat dissipation & strategically placed perforations allowing natural air passive circulation within & into the housing for improved thermal management of internal components, including mounting brackets for fixing complete all as specified and directed comprising :- (a) Mono Crystalline SPV Module 150 Wp. (b) VRLA, Solar Gel tubular Battery 12 v, 150 AH (13.6V - 14.4V) with 03 days backup and 05 years warranty.(Li Ion battery 150 mh) (c) Hot dipped GI tubular pole single arm with base plate, polished finish surface, 6 mtr long above ground, 80 mm dia with wall thickness 3 to 4 mm complete as per manufacturer's instructions and design by OEM. Note : (i) Excavation and earth work shall be measured and paid separately.
Supply and fixing cable route indicator made out cast iron and embedded LT Cable on the plate of size 80 mm dia 5 mm thick and grouting lugg of suitable size including gouted in PCC foundation of suitable size complete all as directed.
Supply and fix PVC Sintex box having aluminium bus bar 4 pole suitable for street light connections including single pole MCB of rating 6 Amps, 2.5 sqmm copper comductor for connection and fixing arrangement to pole all as specified and directed by Engineer-in charge
Supply and fixing of GI tubing light grade of 100 mm dia for cable protection on pole/wall/floor/or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the distrubed surface of wall, floor or roof etc all as specified and directed.
R D Bansal
M/S RAJ KUMAR GUPTA
M/s Amit Associates
Jawandha Enterprises
Vipin Kumar and Brother
Standard Const. Co.
M/S Mukesh Kumar Gupta
HG construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .