Loading…
Loading…
Tender Value
₹7.5 L
EMD Value
₹14,900
Closing Date
15 Jul 2026, 3:00 pm
Similar tender results from the same govt authority in the past 3 years.
Electrification work in connection with Baad- Developement of scrap Yard at Tank Wagon Depot Baad.
T-10-N-2026-27
T-10-N-2026-27
Open
8 Months
Uttara Kannada, Karnataka
₹0
₹14,900
19 Jun 2026
19 Jun 2026
1 Jul 2026
A-Electrification work in connection with Baad- Developement of scrap
Supply of material fixing and providing the Light/FTL/C.Fan/E.Fan concealed wiring point with 2.5 Sq.mm FRLSH/HFFR insulated and sheathed multistrand copper wire 1100 V grade, single core with 1.5sq.mm. PVC insulated copper conductor for continuous earthing in recessed 1 steel/PVC conduit pipe 25mm. 1.6mm.thick dia bend, junction box etc. with ceiling rose batten holder, flush type 5A. switches mounted on white laminated phenolic sheet 3mm. thick cover on front of MS box made of 18 S.W.G. MS sheet of suitable size complete with replastering of wall if required wiring to be done in separate circuit. (Concealed wiring to be done on walls and roof if RCC roof is already constructed surface through PVC casing caping good quality double lock type wiring may be done.)
Supply, erection, Testing & Commissioning of sub main consisting of 2x4 Sq. mm (P& 2 N) PVC insulated and sheathed copper wire multristanded single core 1.1KV grade alongwith 1.5 Sq.mm PVC insulated copper wire 1.1 KV grade for earthing. (Quantity 1 Mtr.Equal to 02 Nos., wire of 4Sq.mm of 01 Mtr.each. and 01 No. earth wire 1.5 Sq.mm. of 01 M) (No cable joint is permitted inside the MS conduit pipe cable should be jointed with cable connectors inside the switch board)
Supply, Erection, Testing and commissioning of MS/PVC conduit pipe 25mm dia 3 and1.6mm thick, recessed in the wall and through the wall by making hole and replastering the same in original condition complete with Tee, elbow, junction box, sadle & Other accessories for sub main wiring.
Supply, Erection, Testing & Commissioning of luminaire complete with all accessories, 4 18/20 watt, 04 feet LED tube light fitting & Tube with suitable current control driver circuit, suitable for surface mounting and connection with PVC copper flexible wire of 23/76 as per Rly. specification attached.
Excavation of cable trench:-This item shall be operated in conformity with IS:1255(latest version) i.e. code of practice for installation and maintenance of HT/LT cables.The price shall cover cost of excavation of cable trench inall type of soil for laying LTcables and back 5 filling thesame with sieved earth and finishing the surface in its original condition after providing sand, & bricks in cross position. For LT/HTcables the trench shall be 600mm wide x 1000mmdeep. In trench the cable shall be covered with riversand at a depth of 100mm below the cable and 100mm above the cable than placing well-burned bricks continuously in cross position through out the cable route inthe ground. The bottom ofthe trench should level freefrom stones and sharp edgeof rocks etc. At the termination a loop of 5 meter(approx) cable shall be keptas allowance and loops ringsbe formed as per the site condition, in the ground, The cost shall include the cost ofall materials i.e. sand, bricks,cable route markers (groutedin the earth firmly with cement concrete so that itcan not be uprooted by miscreants) etc at 25m.interval and each turn of the cable.
Laying/Cleating erection, Testing & Commissioning of HT/LT Cable 03/04 Core on wall with all accessories & refilling of cable trench (asper IE rule) after laying of cable (Cable will be supplied by Rly free of cost at Consignee Depot)
Supply, fixing, testing & commissioning of MCB DB single phase with RCBO, m.s. enclosure, I/C -DP RCBO of 40Amp - 1No, O/G: SP MCB of 6A - 32A - 8Nos, as per specifications. 30 mA
Horizontal boring of cableduct at 1.4 to 2.1 mtr.depth from the bottom of 8 sleeper/ground lable and laying of120 mm dia HDPE DWC pipesfor cable crossing under track/ road .The work shall bedone as per extant practiceand instruction of site engineer.It includes supply of DWC/HDPE pipes conforming to IS14930(Part:2:2001)
Supply, Erection, Testing and commissioning of Single earth electrode of 50mm dia 3000mm long GI Pipe class B conforming to IS: 1239 latest complete with earth box including connection from earth electrode to MDB/SDB/poles/With 8 SWGGI Wire
supply, erection, Testing & Commissioning of energy efficient LED street light fitting 10 60 Watt outdoor complete street light fitting pressure die cast aluminium (PDC) body with make embosed on PDC body and complete with all accessories/ components and connection with PVC copper wire 2.5sq.mm size multicore and fixing arrangement as per site requirement. The technical parameters will generally conform to relevant Railway specification attached Annexure-II
Supply, Erection, Testing and Commissioning of GI pipe 'B' class of minimum 50 mm. dia, suitable for cable protection or underground rail/road crossing with fixing clamp at least 03 Nos. for one pipe of MS flat of 50 x 6 mm. size clamp duly Aluminum painted
Supply, Erection, Testing and commissioning of hot dip galvanized octagonal pole 5 12 Mtr. long confirming to IS 2629/BSEN ISO 1461 or equivalent including casting, muffing with cement concrete foundation (1:2:4) painting, earthing etc. the pole shall be complete with holes, Anchor bolts, bottom plate etc. As per Tech. Specification/site requirement, IS/IE rules of Double Arm type with 1.5 feet to 2 feet long type
Supply, Erection, testing and Commissioning of LT control panel outdoor, cubical floor mounted Hut type dust and vermin proof multi layer construction, weather proof proper ventilation arrangement, outdoor type LT distribution board for operation on 3 phase 4-wire, 415V AC supply system recondition with 14 SWG MS sheet base MS angle 50x50x6 mm MS Channel 75x40x6 mm. It 13 shall be coated with 2 coats approved colour. The LT panel shall be of front operated with copper conductor cable, cable glands, earthing studs, feeder, name plate and danger board on front. The LT panel shall be erected on the floor. The panel shall comprises of 400 Amps copper bus bar with protection equipment, 01 Number incoming side 250A MCCB 50KA, 4X100 A MCCB 36KA, 2X63A MCCB 30KA and 05 Nos. 32A MCCB 3OKA. All MCCB should be 4-pole type voltmeter, Ammeter indicating lamps shall be fitted all incoming and outgoing side complete with locking arrangement and all other required accessories as per site""
Supply, Erection, Testing and commissioning of Termination kit of LT-XLPE cable of various size (One job means all 4 cores of cable)
Supply of material for fixing and providing 5 pin socket outlet point (3 pin + 2 pin) 5- A/230 V. with flush type 5 Amp. Socket combined type with switch in concealed wiring by 2.5 Sq. mm. PVC insulated multistranded copper wire single core 1100 V. Gr. in recessed steel conduit pipe 25 mm. dia & 1.6mm. thickness with 5 Amp. /230 V. flush type switch fixed on white phenolic laminated sheet 3mm. thick cover on front of MS box of suitable size complete including 1.5 Sq. mm. FRLSH/HFFR insulted copper conductors for earthing and replastering of wall.
Supply of material for fixing and providing of concealed wiring point of 6 pin (3 pin 15 Amp. + 3 pin 5 Amp.) power socket flush type 15 A/5 A - 230 V. comprising of switch 15 Amp. & 16 recessed MS conduit wiring or in casing caping PVC double lock type of good quality with suitable wooden board well polished by 4 sq. mm. FRLSH/HFFR insulated multistrand copper cable 1100 V. grade single core including 1.5 sq. mm. FRLSH/HFFR insulated copper conductor for earth wire, mounted on white phenolic laminated sheet 3mm. thick cover on front of MS box 1.6mm thickness complete with replastering of wall. (Separate circuit to be drawn from SDB.)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril202227-04-2022.pdf
ATTACHMENT
GCCACScorrectionslip1_compressed.pdf
ATTACHMENT
correctionslipNo.-02GCC13-12-22.pdf
ATTACHMENT
CorrectionslipNo.-03ofGCC-2022.pdf
ATTACHMENT
GCCCorrection07-08-2023SlipNo.4.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_5ACS-5.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_6ACS-6.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_7ACS-7.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-8.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-9.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-10.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_11_compressed.pdf gcccorrectionslip11
ATTACHMENT
AnnexureC.pdf
ATTACHMENT
AnnexureVA1Policy.pdf
ATTACHMENT
Letterofcredit.pdf
ATTACHMENT
Shramikkalyan.pdf
ATTACHMENT
T-10-N-2026-27TENDERDOCUMENTS.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_11_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid