Tender Value
₹15.4 L
EMD Value
₹30,900
Closing Date
20 Jan 2026, 1:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER
43 conditions · 7 needing a document upload
Valid copy of PAN and GSTIN needs to be furnished along with the documents.
Tenderer should fill up the Tender Form (First Sheet) as per 'Annexure-I' of GCC. Incomplete or partial fill up the Tender Form (First Sheet) by the Tenderer will be liable to reject.
For Sole Proprietorship firm a)Affidavit as per 'Annexure'. b)Special power of Attorney as per proforma given in 'Annexure' to be submitted by sole proprietor firm duly notarized.(Not required if tender documents are submitted by proprietor himself) (Mandatory)
For Partnership firm a)Self/Notary attested copies of Partnership deed. b)Special Power of Attorney as per proforma given in 'Annexure' to be submitted by Partnership firm. (Not required if one or more partners are authorized in Parternership deed to sign on behalf of the firm.)
For Limited Company a) Copy of Memorandum & Articles of Association of Company. b)Self /Notary attested copy of resolution passed by Board of Directors authorizing its Director/Employee to deal with tender on behalf of company. c) Attested copy of Notarized Special Power of Attorney including ratification clause duly signed by person authorized by the company.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer is advised to study the uploaded tender document in www.ireps.gov.in portal carefully
The Conditions of tender shall be read in conjunction with General Condition of Contract/2022 subject to modification, additions or supersessions by Special Condition of Contract and Specification if any.
The tenderers are required to observe the website to find out if any correction slips issued subsequent to uploading of the Tender. Railway reserves the right to make any additions/alterations to the tender uploaded and issue corrigendum to the same effect. In case the tenderer fails to take note of the above corrigendum, the additions and alterations entered/effected in the corrigendum shall be binding upon the tenderer and no claim whatsoever will be entertained by Railway.
No manual tenders sent by post/Fax/courier or in person shall be accepted.
At NBQ - Electrical works in connection with Renovation of Railway Senior Institute.
RNY-EL-T-22-2025-26~NFR
RNY-EL-T-22-2025-26
Open
Works - General
180 Days
Kamrup, Assam
₹0
₹30,900
20 Jan 2026
26 Dec 2025
6 Jan 2026
75 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 15,43,810.14 | ||
| — | 70.00 | — | — | ||
| Supply and surface wiring of light/FL point by PVC insulated & un-sheathed FRLSH multi strand copper single core 1.5 sq.mm cable through PVC casing & caping including ceiling rose. Cable connection to be done through 6 A flush type controlling switch installed in suitable size PVC board & connected by Cu flexible wire from ceiling rose to fittings as per direction of EIC at site. | — | — | — | 17,643.5 | |
| — | 25.00 | — | — | ||
| Supply and surface wiring of ceiling fan point by PVC insulated & un-sheathed FRLSH multi strand copper single core 1.5 sq.mm cable through PVC casing & caping including ceiling rose. Cable connection to be done through 6 A flush type controlling switch including 5 point electronic regulator installed in suitable size PVC board with earth continuity by 1.0 sq.mm multistrand copper cable & connected by Cu flexible wire from ceiling rose to fan as per direction of EIC at site. | — | — | — | 13,606.5 | |
| — | 10.00 | — | — | ||
| Supply and surface wiring of circulating fan point by PVC insulated & un-sheathed FRLSH multi strand copper single core 1.5 sq.mm cable through PVC casing & caping including 5A 5 pin socket & switch. Cable connection to be done through 6 A flush type controlling switch including 5A 5 pin socket & switch installed in suitable size PVC board with earth continuity by 1.0 sq.mm multistrand copper cable & connected by Cu flexible wire as per direction of EIC at site. | — | — | — | 5,734.2 | |
| — | 12.00 | — | — | ||
| Supply and surface wiring of exhaust fan point by PVC insulated & un-sheathed FRLSH multi strand copper single core 1.5 sq.mm cable through PVC casing caping including ceiling rose. Cable connection to be done through 6 A flush type controlling switch including suitable size PVC board with earth continuity by 1.0 sq.mm multistrand copper cable & connected by Cu flexible wire from ceiling rose to fan as per direction of EIC at site. | — | — | — | 3,128.04 | |
| — | 25.00 | — | — | ||
| Supply of of 1200mm sweep, BEE star rated - 5 star rated BLDC ISI marking ceiling fan with 450mm down rod, canopy and all accessories as per direction of EIC at site. | — | — | — | 1,21,533.25 | |
| — | 25.00 | — | — | ||
| Fixing and commissioning of ceiling fan 1200 mm sweep with suitable size GI pipe, MS hook, clamp, nut & bolts arrangements as required as per direction of EIC at site (Ceiling fan will be supplied by Railway) | — | — | — | 892.25 | |
| — | 12.00 | — | — | ||
| Supply, testing and fixing of 300 mm sweep exhaust fan complete by cutting wall, masonry work as required and fixing by suitable nuts and bolts arrangement as per direction of EIC at site. | — | — | — | 22,077.6 | |
| — | 30.00 | — | — | ||
| Supply and surface wiring of 6A 5 pin plug point by PVC insulated & un-sheathed FRLSH multi strand copper single core 2.5 sq.mm cable through PVC casing & caping, with earth continuity by single core 1.0 sq mm copper cable including suitable size PVC board. Cable connection to be done through 6 A flush type controlling switch, socket installed in PVC board hylum sheet on top and as per direction of EIC at site. | — | — | — | 10,440 | |
| — | 10.00 | — | — | ||
| Supply and surface wiring of 16 A, 6-pin Plug point by PVC insulated and un-sheathed FRLS multi stranded copper cable, single core 4.0 sq.mm with earth continuity by 1.0 sq.mm multistand copper cable through PVC casing & caping including suitable size PVC board. Cable connection to be done through 16 A flush type controlling switch, 16A socket installed in board and as per direction of EIC at site. | — | — | — | 6,010 | |
| — | 1000.00 | — | — | ||
| Supply & surface wiring of earth continuity through the Main line/ Submain line circuit by 1.0 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through PVC casing & caping as required as per direction of EIC at site. | — | — | — | 10,310 | |
| — | 2000.00 | — | — | ||
| Supply & surface wiring of the Sub-main line by 2.5 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through PVC casing & caping as required as per direction of EIC at site. | — | — | — | 50,180 | |
| — | 1600.00 | — | — | ||
| Supply & surface wiring of the Main line/Sub-main line by 4.0 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through PVC casing & caping as required as per direction of EIC at site. | — | — | — | 60,880 | |
| — | 800.00 | — | — | ||
| Supply & surface wiring of the Main line by 6.0 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through PVC casing & caping as required as per direction of EIC at site. | — | — | — | 45,424 | |
| — | 500.00 | — | — | ||
| Supply & fixing of PVC Casing & Caping 25x12 mm for drawing of Main line/ Submain line as required as per direction of EIC at site. | — | — | — | 25,465 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing & commissioning of TPN distribution board 16 way double door metal TPN DB consisting 100A, MCB TPN - 1 no, 40A, MCB TPN - 3 nos, 16A, MCB DP - 2 nos with enclosure and necessary fixing arrangements as per direction of EIC at site. | — | — | — | 82,628.79 | |
| — | 1.00 | — | — | ||
| Machine spray painting & repairing of existing control panel by replacing of defective switchgears as per direction of EIC at site. | — | — | — | 17,500 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing & commissioning of sound system board having (i) 16A plug point - 3 Nos, (ii) 5A plug point - 4 Nos and connection by 6 sq mm single core copper cable as per direction of EIC at site. | — | — | — | 91,231.5 | |
| — | 5.00 | — | — | ||
| Supply, installation, testing & commissioning of TPN distribution board 8 way double door metal TPN DB consisting 63A, MCB TPN - 1 no, 40A, MCB DP - 2 nos, 25A, MCB DP - 1 nos & 10A MCB SP - 2 nosand with enclosure and necessary fixing arrangements as per direction of EIC at site. | — | — | — | 53,568.85 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing & commissioning of SPN distribution board 8 way double door metal SPN DB consisting 40A, MCB DP - 1 no, 20A, MCB DP - 2 nos, 6A, MCB SP - 2 nos with enclosure and necessary fixing arrangements as per direction of EIC at site. | — | — | — | 30,713.16 | |
| — | 14.00 | — | — | ||
| Supply, installation, testing & commissioning of IP 65 45 watt street light fittings complete including all accessories as per direction of EIC at site. Lumens out put should be of 100 Lumens/watt, LED should be as per LM-80/IS: 16105. LED driver's efficiency should be minimum 90%, Power factor of complete fitting should be greater than 0.90, Input operating voltage: 140V to 277V AC and driver should be as per IEC: 62384/IS:16104. The LED fittings should be warranted for 5 years. | — | — | — | 74,990.02 | |
| — | 10.00 | — | — | ||
| Supply,testing, installation and commissioning of IP 66 high power LED flood light luminaries 120 watt LED with pressure die-cast aluminuium housing, complete with all accessories as per direction of EIC at site. Lumens out put should be of 120 Lumens/watt, LED should be as per LM-80/IS: 16105. LED driver's efficiency should be minimum 90%, Power factor of complete fitting should be greater than 0.90, Input operating voltage: 140V to 277V AC and driver should be as per IEC: 62384/IS:16104. The LED fittings should be warranted for 5 years. | — | — | — | 2,26,750.9 | |
| — | 50.00 | — | — | ||
| Supply, installation, testing & commissioning of 18/20W LED tube light fitting with polycarbonate housing with THD less than 20% and surge protection 1.5KV 6000K (4 ft) complete with driver circuit etc and all accessories as per direction of EIC at site. Lumens out put should be not less than 100 Lumens/watt, LED should be as per LM-80/IS: 16105. LED driver's efficiency should be minimum 90%, Power factor of complete fitting should be greater than 0.90, Input operating voltage: 140V to 277V AC and driver should be as per IEC: 62384/IS:16104. The LED fittings should be warranted for 5 years. | — | — | — | 16,455.5 | |
| — | 20.00 | — | — | ||
| Supply, installation, testing & commissioning of 15 watt LED round recess mounting down light including all accessories as per direction of EIC at site. | — | — | — | 33,712.2 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of 400 mm sweep, heavy duty wall fan complete as required and fixing by suitable nuts and bolts arrangement through switch as per direction of EIC at site. | — | — | — | 14,016.7 | |
| — | 10.00 | — | — | ||
| Supply , installation and commissioning of 450mm high speed industrial air circulating fan as per direction of EIC at site. | — | — | — | 94,380 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing & commissioning of Stage projecting light as per direction of EIC at site. | — | — | — | 23,394 | |
| — | 10.00 | — | — | ||
| Supply, fitting, fixing and commissioning of 08 Watt LED Bollard fitting complete with driver circuit, lamp etc and all accessories as per direction of EIC at site. | — | — | — | 52,764.3 | |
| — | 200.00 | — | — | ||
| Supply, wiring and commissioning of strip type LED tony light (Try colour) as per direction of EIC at site | — | — | — | 68,000 | |
| — | 6.00 | — | — | ||
| Supply and erection of earthing by made of B class GI pipe of 3000 mm length, 50 mm diameter & 3.6 mm thickness. The GI Strip ( should be welded with the earth pipe. The pipe is provided with a tapered casing at the lower end in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an effective earth value.The connecting conductor from earth electrode to the distribution panel board should not be thinner than 8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil. Where soil restivity is high, earth restivity enhancing material may be used, Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. As per Drg. No. DRG NO: PCEE/ELG/DRG/2024/1 dated 30.09.2024 & as per Technical circular no. EL/PS/2024/1 (EARTHING SYSTEM). | — | — | — | 8,493.6 | |
| — | 2.00 | — | — | ||
| Supply and erection of earthing by made of B class GI pipe of 3000 mm length, 80 mm diameter & 3.6 mm thickness. The GI Strip ( should be welded with the earth pipe. The pipe is provided with a tapered casing at the lower end in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an effective earth value.The connecting strip from earth electrode to the distribution panel board should not be thinner than 25mm GI strip to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil. Where soil restivity is high, earth restivity enhancing material may be used, Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. | — | — | — | 3,507.2 | |
| — | 1.00 | — | — | ||
| Shifting & erection of 4 arm 12 mtr height tubular pole at staff rest house DTX NBQ including man power & materials as per direction of EIC at site. | — | — | — | 15,000 | |
| — | 8.00 | — | — | ||
| Supply, carrying, loading & unloading of 5 mtr long with suitable size designer single bracket G I octagonal pole including base plate of size 200x12mm, PCD - 200mm, junction box and foundation bolt 4x16 Nos (Length 600mm) etc. and erection with execution of CC foundation work of size 45cmx45cm in ratio 1:2:4 by cement,sand and chips of size 19 mm and down upto full depth & 1ft above the GL as per direction of EIC at site & including 6A SP MCB. | — | — | — | 1,10,845.92 | |
| — | 1.00 | — | — | ||
| Design, fabrication, supply, installation, testing and commissioning of outdoor type Panel board comprising of following items and made of MS angle, channel by MS sheet of not less than 18 SWG duly welded and painted by 2 coats of primer, two coats of finishing paint (spray paint) Doco/Nerolac brand of approved colour both in interior and exterior as per direction of EIC at site - i) 100A,4P, 18KA, Ics = 100% Icu, conforms to IEC 60947-2 MCCB - 1 nos, ii) 63A, MCB TPN - 2 nos, iii) 40A, MCB DP - 1 nos & iv) 200A 4P copper bus bar - 1 set. as per direction of EIC at site. | — | — | — | 9,630.16 | |
| — | 50.00 | — | — | ||
| Supply, fixing, installation & testing of Energy efficient LED name board for Stations to be written in English, Assamese & Hindi made of stainless steel channel letters of letter height 24",depth 6", width 7" made with stainless steel of grade 316 (mat finish). The channel letters will be fitted with LED modules consisting of 2 LED per module and the LED module will be fitted over a 3 mm foam board to secure fixing into the letters & the letter face will be covered with 3 mm acrylic sheet of matching colour with LEDs will be given a uniform illumination without any dark spot when the LED are lit up. The LED modules should have hi-lux piranha Red colour LED and connected in parallel mode. The LED s system should consist if minimum of six LEDs in 3 module s for uniform illumination of the channel letter face with minimum lumen output of 20 lumens per feet. The LEDs will be pasted and screwed in the foam board of 3M VHB double sided adhesive tape & steel screw all other parameters etc. and as per direction of engineer in charge at site. | — | — | — | 75,697.5 | |
| — | 1.00 | — | — | ||
| Carrying, loading, unloading and erectlon of 4 mtr high 02 nos rail pole with necessary structure for flttlng of glow slgn board (Rail pole will be supplied by Railway ) | — | — | — | 10,000 | |
| — | 300.00 | — | — | ||
| Laying of above LT XLPE insulated armoured aluminium cables as per instruction of site engineer (Cable should be supplied by Railway) | — | — | — | 3,873 | |
| — | 250.00 | — | — | ||
| Excavation of cable trench 0.75 mtrs. below the GL with laying of armored cable and refilling the same by supply of 70mm sand and soil after digging the earth. The laying of armoured cable should be done as per direction of Engineer at site. (Cable will be supplied by Railway). | — | — | — | 33,332.5 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .