Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC 142 JAGJIVANRAM NAGAR GAROBA MAIDAN NAGPUR 440008 | NAGPUR | NAGPUR | MAHARASHTRA | 440008 | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹9.8 L+₹24,485 (2.56%)Rejected-AOC | L2 | Rejected-AOC Not being the lowest | |
| 3 | L3₹10.5 L+₹89,450 (9.35%)Rejected-AOC | L3 | Rejected-AOC Not being the lowest |
Tender Value
Refer Docs
EMD Value
₹17,400
Closing Date
8 Dec 2021, 6:00 pmClosed
AGE (I) AF Sonegaon
Bldg No. P-51, 44 wing Air Force Station, Sonegaon, Nagpur 440 005
SPECIAL REPAIR REPLACEMENT TO THE MAIN INCOMING CI GI WATER PIPELINE AT SONEGAON NAGPUR
2021_MES_476416_3
8400/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) AF Sonegaon
As per NIT
7 documents required · 7 mandatory
₹500
AGE (I) AF Sonegaon
₹17,400
Yes
28 Jan 2022
23 Nov 2021
10 Dec 2021
23 Nov 2021
8 Dec 2021
24 Nov 2021
23 Nov 2021 - 30 Nov 2021
Amount
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth and getting out in any type of soil for laying of pipes all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick all as specified and as directed.
Removal of excavated materials to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
Taking up or down GI steel tubing and connection including fittings cleaning for refixing complete all as specified and as directed for the following sizes :-
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
Refixing/ laying &Testing of steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors / trenchescomplete all as specified for the following sizes :-
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
Suply and laying of GI tubing medium grade with all fittings (such as bends, elbows, tees, short pieces, connectors, back-nuts, diminishing pieces, caps, plugs and unions etc.) including cutting for branch line & making threads complete fixed to wall/flooring /ceiling etc or laid in trenches all as specified.
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
Taking down gate valves from existing pipe line for repair/replacement and removing to store for safe custody or for reuse after repairs or issue under sch of credit of size
20mm bore
25mm bore
40mm bore
50mm bore
Supply and fix gun metal globe or gate valves with iron wheel head screwed both ends for GI pipe all as specified for the following sizes.
20mm bore
25mm bore
40mm bore
50mm bore
Taking down ball brass valves from existing pipe line for repair/replacement and removing to store for safe custody or for reuse after repairs or issue under sch of credit of size
15mm bore
20mm bore
25mm bore
Supply and fix Ball brass valves,high pressure with polythene float and flynut complete, screwed for iron complete pipe or brass ferrule and fix to inlet of delivery main of water storage tank all as specified for the following sizes:-
15mm bore
20mm bore
25mm bore
Taking down carefully damaged CI pipe from trenches after burning out lead for repair / replacement and removing material all as specified for the following sizes.
150 mm dia bore
80 mm dia bore
Relaying only CI pipes after replacement broken / cracked pipes etc complete all as specified and directed for the following sizes.
150 mm bore
80 mm dia bore
Supply and lay in trenches cast iron pipe centrifugally cast spigot and socketed ends class LA for repair/ replacement in the pipe line complete all as directed and as specified. Note;- Lead joints shall be measured and paid seperately.
150 mm dia bore
80 mm dia bore
M & L for run lead joint for 150mm bore complete all as directed and as specified.
M & L for run lead joint for 80mm bore complete all as directed and as specified.
M&L for CI fittings any type such as bends( any type radius and angles) reducers Tees Y pieces collars, caps plugs and straight connecting pieces upto 150mm bore complete all as directed and as specified.
Taking down valves/meter chamber cover complete with frame from the existing location and removing to store for safe custody for reuse or for issue under sch of credit complete all as directed and as specified.
M&L for valve chamber cover with frame and locking arrqngement made out of angle iron or other section and MS sheet with welding of holdfast etc. including hinges fabricated MS is not less than the thickness of frame all as specified including preparation of surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer. (Fe 410-W(Gde-E-250)quality-A) complete all as directed and as specified.
Taking down existing sluice valve with flanged end cast iron body including repair/renewal of spare parts valve spindle,spindle nut,caps ,gland rope,gland studs,rubber gasket during process of repairing & same fixed on existing line complete all as directed and as specified.
200 mm bore
100 mm bore
80 mm bore
S & F in repairs sluice valve 1.6PN size 100mm (4") dia suitable for existing main CI pipe line at Pump house complete all as directed and as specified.
Dismantling and removing damaged portion of brick masonry, PCC coping pits of valve chambers and removing from site for disposal more than 50 mtr where directed by Engineer-in-charge. complete all as directed and as specified.
M&L for brick masonry with sub class B bricks exc 6 meter mean radius in cement mortar 1:6 complete all as directed and as specified.
M&L for PCC coping 1:2: 4 type B-1 using 20 mm graded stone aggregate complete all as directed and as specified.
M&L for rendering with 15 mm thick in cement mortar 1:4 on fair surfaces of brick work or concrete surfaces finished even and smooth surfaces without using extra cement complete all as directed and as specified.
S & F in Repairs unserviceable foot valve from UG sump by means of opening of existing 50mm bore GI tubing and lowering in sump after replacing foot valve and make good priming system complete all as directed and as specified.
All as per Item No 24 here in before but 80mm bore
S&F in repair rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed Top) hoisted and fixed in position all as specified in SSR Part I, 500 Litres capacity complete all as specified and directed.
S & F in repair Rotational moulded polyethyne water storage tanks (cylinderical vertical with closed top) hoisted & fixed in position all as specified with capacith1000ltr complete all as specified and directed.
M/s JAYPEE ENTERPRISES
PURVA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .