Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹28.3 L+₹73,044.50 (2.65%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹28.7 L+₹1.2 L (4.22%)Rejected-Finance RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹29.9 L+₹2.3 L (8.43%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹31.7 L+₹4.1 L (15.0%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
27 Apr 2024, 6:00 pmClosed
GE (CENTRAL) DELHI CANTT-10
GE (CENTRAL) DELHI CANTT-10
REPAIR TO CERTAIN WALL, PLASTER, CEILING, JOINERIES, TILING, SANITARY FITTING, ROOF TREATMENT, PLUMBING AND EXTERNAL PERIODICAL SERVICES INCLUDING REPAIR/ REPACEMENT OF UNSERVICEABLE ELECTRICAL FITTING WITH LED LIGHT FITTING INCLUIDING MCBs, MCCB AND
2024_MES_648633_1
GE/C-13/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹1 L
Yes
27 Jun 2024
30 Mar 2024
29 Apr 2024
30 Mar 2024
27 Apr 2024
13 Apr 2024
30 Mar 2024 - 13 Apr 2024
Amount
M & L for Taking down cement plaster in brick walls,including raking out joints,hacking for key, scrubbing down with water etc including scaffolding if required complete all as specified.
M&L for rendering 10 mm thick in CM (1:6) on any faces of concrete or brick surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L for two coat of distemper oil emulsion over a coat of primer and 2-3 mm thick wall care putty including preparation of new plastered surface of wall complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of ceiling including pilasters and cornices etc , brooming down, etc and applying one coat of white washing complete all as specified and as directed.
M&L for old decorated surfaces plastered or unplastered surface of wall and applying two coat of oil bond distemper over one coat of wall care putty on wall complete all a spcefied.
Dismantling of wall and ceiling board fibre pulp AC boards etc any thickness including cover fillets removing the wiring and refixing the same including fixture as necessary at site including frame work.
M & L for snap grid ceiling with E - board ceiling tiles of size 600x600mm 4mm thick incl aluminium alloy anodised at edges angle 25x25x1.5mm and tee section 38x38x1.5 mm at other than edges both ways fixed with 4mm dia gi wire including two coats of oil bound distemper.
S&F for 19/20mm thick Block board grade 2 quality interrior grade commercial type fixed with screws to timber frame work including teak wood leaping and necessary rebating for double shutter where required. (Note : teak wood leaping shall be measured and paid separatly)
Supply only butt hinges medium weight stainless steel 75mm size Complete all as specified and directed by Engineer-in-Charge.
S&F 40mm dia cupboard knobs fixed with nut screw and washer of mild steel, bright finished.
M&L second class hard wood timber scantling plain fillets, square, rectangular or triangular in section clear swan, sectional area exc 13 sqcm & not exc 25 sqcm, secured with nails or brads.
Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame).
Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame).
Taking down shutters of any discription exceeding 1 sqm each and not exceeding 2 sqm each.
M&L Mild steel frame work as in door chowkhats with angle iron welded together ends of angle shouldered and fixed to opening and welding 3 Nos mild steel butt hinges 100 mm size, and 6 nos hold fasts made out of FI 25x3 mm 30 cm long for fixing of chowkhats( Butt hinges paid sep) all as spd.
S&F 30 mm thick 2nd class hard wood glazed and skelton shutter devided into square with plain, chamferred or rounded sash bar and fitted with cut and mitred beads for securing glass, size of members as per SSS Part - I section 8 clause 8.24 (b).
S&F 30MM thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and as directed.
M & L for 35 mm thick factory made 2nd class hardwood plain, framed, panelled shutters (two panels), with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. the size of rail and stile as per IS:1003 (Part-I) kiln seasoned and chemically pressure treated.
M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
M & L for preparation of old wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-charge.
S&F Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame and fixing with ancher bolts all as specified and as directed.
30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
Supply only MS butt hinges medium weight 100 mm size fixed with MS screws.
S&F aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws.
S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with mS screws.
S&F 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut.
S&F in repair 300 mm MS ordinary rat tail rod pattern spring including roller and roller plate complete fixed on wooden frame or on wall with wooden plugs and set in cement mortar all as directed.
Dismantling wrought iron or mild steel work of any description such as guard bars, grills etc.
S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410-W (Gde-E-250 quality A) complete all as specified.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
S & F Steel window (Factory made) double rebate, with side hung, shutter incl hinges, tower bolt, steel handle and peg stay complete with glaze and gauge shutters (both are complete) devotailed or welded including making good to cutting holes with PCC 1:2:4 complete all as specified.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 sqm in each pane complete all as specified and directed.
S & F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
S&F in repair 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 sqm in each pane complete all as specified and directed.
Material and labour for aluminium alloy Powder coated standard 10mm section and opening of size window grill as per approved sample and as per IS specifications complete all as specified and as directed.
S&F in repairs stainless steel plate rack of size 90x80x25 cm depth size made out of 0.80mm thick sheet complerte all as specified and directed by Engineer-in-Charge.
S&F stainless steel sink with drainage board made out of 0.80mm thick sheet for kitchen with plug, washers, waste pipe incl fixing cast iron cantilever bracket connecting union over all size 915x460mm with bowl size410x330x160mm complerte all as specified and directed by Engineer-in-Charge.
Material and labour for welding in repairs not exc 2.5 cm in length complete all as directed .
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm.
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 20mm.
Supply and fix galvanized steel tubing, 15 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed.
Supply and fix galvanized steel tubing, 20 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed
S & F in repairs 15 mm bore GI fittings such as union, Socket, Tee, Elbow, Nipple 4" 6", Reducer, Plug, and tank nipple complete all as specified and directed.
S & F in repairs 20 mm bore GI fittings such as union, Socket, Tee, Elbow, Nipple 4" 6", Reducer, Plug, and tank nipple complete all as specified and directed.
Supply and fix in repairs vitreous china wash hand basin (flat back) white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size and waste pipe & waste fittings complete all as specified.
Supply and fix in repairs vitreous china squatting pan Orissa pattern long pan size 580x440mm white with integral foot rests ‘standard Grade P’ or ‘S’ trap front or back inlet (excluding flushing cistern and flush pipe ) complete all as specified and directed by Engr-in-Charge.
S & F in repairs floor mounted EWC incl all necessary fittings complete all as specified and directed by Engr -in-charge.Note:- Cistern and seat cover paid seperatly.
Supply and fix in repairs PVC low level white flushing cistern valveless syphonic action type 10 lts capacity IS marked with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC,(ISI Marked) complete all as specified.
S&F in repairs PVC waste pipe 32 mm dia for wash hand basin, complete all as specified.
S & F in repairs 32mm dia sink waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm- 45gms/40mm-60 gms) complete all as specified and directed.
S & F in repair 15 mm dia 600mm long PVC connections with brass check nut complete.
S & F in repair Glass Corner Shelf 6mm thick including CP railing radius 250mm complerte all as specified and directed by Engineer-in-Charge.
S&F in repairs Glass shelf assembly 5.5mm thick, 600mm long 120mm wide with cp railing complerte all as specified and directed by Engineer-in-Charge.
S&F in repair Health faucet, CP brass with 1.50m long flexible pipe complerte all as specified and directed by Engineer-in-Charge.
S&F in repair CP jet spray for EWC with flexible pipe and angle cock/stop cock complete all as specified.
S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified.
S&F in repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as directed.
S&F in repairs 2-in-1 angle valve, fancy type, chromium plated brass, 15mm, complete all as directed.
S&Fin repairs shower rose, chromium plated brass, fancy type, 100x100 mm, with or without swivel , any size, including fixing to steel pipe or union, complete all as directed.
S&Fin repairs 15 mm dia pillar taps, fancy type brass with capstan head chromium plated screwed down high pressure with or without lettered “hot/cold” with long screwed shank and flynut screwed complete all as specified.
S&F in repairs plastic water closet seat cover white closed pattern with flat bottom end cover and mild steel chromium plated hanging device complete all as specified.
S&F in repairs chromium plated brass central hole WHB mixer 15 mm bore chromium plated, fancy type including joints to hot and cold complete all as specified.
S&F in repairs of 15mm bore size PVC PTMT bib tap complete all as specified.
S & Fixed in repair PVC mirror cabinet made of high intensity polythene of biggar size 500 x 400 x 120 mm complete all as specified.
S&F in repair stainless steel gratings 100 mm bore size fixed with cement motar.
S&F in repair toilet paper holder fixed to wall with chromium plated brass screws and rawl/phil plugs complete all as directed all as ppecified .
S&F in repairs chromium plated soap dish fancy type all directed. complete all as directed all as ppecified .
S & F in repair towel rail 600mm long brass chromium plated of 20mm dia (external) and 1mm thickness with gutties embeded in cement mortar 1:3 with MS screws etc complete all as specified and directed.
S & F in repair 140mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
S&F in repair brass chromium plated mode 3 in 1 wall mixture model Quarter half turn (SOLO) of as all specifed and as directed. Code SOL-6281
Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed.
S&F Non - skid Ceramic colour tiles 600 x600 x 7 to 8 mm thick in floors etc and 15mm thick screed bed 1:6 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to match Complete all as specified and directed by Engineer-in-Charge.
S&F Non - skid Ceramic colour tiles 600 x100 x 7 to 8 mm thick in vertical surfaces etc and 10mm thick screed bed 1:4 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to matchComplete all as specified and directed by Engineer-in-Charge.
Dismentling asbestos cement corrugated or semi corrugated sheets in roof fixed with L hook or cranked bolt.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding/ridges/gutter to wall, fixed with self tapping screws as specified.
Demolition of concrete and pavings n.exc 15 cm thickness (below or above ground level).
M&L for cement concrete 40mm thick type B-1, 1:2:4 (using 20 mm graded aggregate) as in floor for fair finished surfaces of concrete complete all as specified and directed.
M&L for cement concrete 75mm thicktype C-2 1:3:6 (40mm graded aggregate)as in plinth protection and paths laid in alternative panel.
Material and labour for rotational moulded polyethylene water storage tanks white colour 500 lts capacity, triplr layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description.
Material and labour for rotational moulded polyethylene water storage tanks white colour 1000 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description.
S&F 15 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed.
S&F 20 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed.
Demolition and breaking up rain water pipes (CI,AC,PVC etc) set in any cement mortor of any diameter incl bends.
S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110mm bore complete.
S&F in repair PVC (SWR) bends any radius, 110 mm bore complete.
M&L for rendering 15mm thick in CM 1:4 on fair faces or other than fair faces of brick work or concrete surfaces firnished even and smooth without using extra cement up to hieght of four storey bldg ,including scaffolding complete all as specified and directed by Engineer-in-charge.
M & L for applying two coats of cement base paint over one coat of primer on newly plastered surfaces(external) of walls including preparation of new surfaces up to hieght of four storey bldg ,including scaffolding complete all as specified and directed by Engineer-in-charge.
M & L for applying two coats of weather proofing exterior acrylic emulsion paint over one coat of primer on newly plasterd surface up to hieght of four storey bldg ,including scaffolding complete all as specified and directed by Engineer-in-charge.
complete removal exising teratment from old surface of wall by scrubbing with hard brushing, brooming down or steel wire brushing scraping down smook soot mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water & applying two coat cement base paint over one coat of primer on old plastered surfaces of walls up to hieght of four storey bldg ,including scaffolding complete all as specified and directed by Engineer-in-charge.
complete removal exising teratment from old surface of wall by scrubbing with hard brushing, brooming down or steel wire brushing scraping down smook soot mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water & applying two coats of weather proofing exterior acrylic emulsion paint over one coat of primer up to hieght of four storey bldg ,including scaffolding complete all as specified and directed by Engineer-in-charge. Notes for item No 8, 10, 92 and 93: (a) The work shall be executed through authorised applicator of manufacturer only. (b) Authrised Applicator shall be approved by GE before starting of work. (c) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material. Engineer-in-Charge shall deface the original purchase vouchers. (d) MOU with authorized applicator will be submitted successful L1 bidder after opening of Financial Bid within a fixed time frame of 7 days otherwise tender will be cancelled. (d) A guarantee amount of 5% of contract of work done for item No 92 and 93 of BOQ will be retained for 5 years of the completion of work.
M & L for preparation of old steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-charge.
M & L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water. The size of block shall be of 2 Qtrs on each floor and vary in number of floors. All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint all as specified and directed by Engr-in-charge.
Re-writing and repainting of letters or figures (Block,roman,italic or indian) not exc 30 cm high with thick paint complete all as specified and directed by Engineer-in-charge.
S & F 100 mm bore cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified & directed.
S & F 75 mm bore cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified & directed.
S & F 50 mm bore cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified & directed.
S&F in repair 100 mm bore cast iron bends complete all as specified and as directed.
S&F in repair 75 mm bore cast iron bends complete all as specified and as directed.
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded new metal flush box duly make embossed, concealed in walls with for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:-
One light/Exh fan point controlled by one No one way switch
One bell / buzzer point controlled by one bell push
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
All as per item No 103 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board.
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 1.5 sqmm (nominal dia) FRLS 1100 Volts in existing PVC concealed conduit in new M S steel terminal boxes of wall thickness not less than 1.6mm including 3 mm thick laminated top sheet cover including using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth all as specified and directed by Engr-in-Charge.
One light/Exh fan point controlled by one No one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 2.5 sqmm (nominal dia) FRLS 1100 Volts in existing PVC concealed conduit in new M S steel terminal boxes of wall thickness not less than 1.6 mm including 3 mm thick laminated top sheet cover including using 2.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one power point, all as specified and directed by Engr-in-Charge.
M&L in replacement switch piano flush button type single pole one way 6 Amps all as specified.
M&L in replacement switch piano 6 amp SP two way, ISI marked.
M&L in replacement socket outlet 6 Amp flush button type all as specified.
M&L in replacement bell push single pole 6 Amps all as specified .
M&L in replacement switch piano flush button type single pole 16 Amps.
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole .
M&L in replacement regulator electronic switch type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed.
M&L in replacement bell electric (dingdong) 230 volt, SP all as specified and directed.
M/L in replacement insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed.
S&F ceiling rose surface PVC 65x50 mm type with three terminals. (For Exhaust Fans)
M&L in replacement switch Modular type 6 Amps one way ISI marked 230V AC complete all as specified.
M&L in replacement Modular socket outlet 5 pin 6 Amp socket 2 module ISI marked complete all as specified.
M&L in replacement switch Modular type 16 Amps one way ISI marked 230V AC complete all as specified.
M&L in replacement Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified.
Supply & Fix in replacement Modular five stepped type electronic fan regulator 2 module ISI marked 230V AC complete all as specified.
S & F in replacement white cover plate with frame,1module complete all as specified.
S & F in replacement white cover plate with frame,2 module complete all as specified.
S & F in replacement white cover plate with frame,3 module complete all as specified.
S & F in replacement white cover plate with frame,4module complete all as specified.
S & F in replacement white cover plate with frame,6 module complete all as specified.
S & F in replacement white cover plate with frame,8 module complete all as specified.
S &F exhaust fan 300 mm in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor from ceiling rose to fan, length as per requirement at site.
Supply and fixing in replacement Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete all as specified and as directed.
M&L in replacement MODULAR BOX TYPE sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'B' series 20 A capacity all as specified and directed.
Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix in replacement LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. (Mirror light). .
Supply and fix in replacement surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix in replacement LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base.
Supply and fix in replacement LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base.
Supply & fix in repair factory made epoxy powder coated Distribution Board VTPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
Supply and fix in repair MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in repair MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in repair MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .
Supply and fix in repair MCB SPN 40 to 63 Amps 240 volts 10 KA 50 HZ 'B' curve complete.
Supply and fix in repair MCB SP 6 to 32 Amps 240 volts 10 KA 50 HZ 'B' curve complete.
Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories(Surface) in walls all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. wire from earth electrode to the Main switch/Distr Board, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed.
Supply and Fix in repair 35/40 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.
Supply and fix in replacement recessed mounting LED FLAT panel 2"x2" made of crca sheet steel duly power coated with high efficient LED 35/36 watt and glaire free full opal diffuser , IP 20 Suitable for 36 watt,230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories complete all as specified and directed.
Supply only exhaust fan motor capacity 1/4 HP 230 volts suitable for 250 mm size exhaust fan complete all as directed.
S & F hole fastner madeup of MS 4" long with complete nut bolt all as specified.
Refixing of Ceiling fan / exhaust fan/ fresh air/ Wall mounted fan including taking down after necessary repairs/ replacement of unserviceable/ wornout part and testing the same as per entire satisfaction of Engr-in- Charge complete all as specified and directed. Note- Spare Parts shall be measured and paid separately under relevant item of supply only.
M&L for opening up the winding of ceiling fan 1200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Teating of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
S&F in replacement capacitor of 2.5 MFD.
Supply only gun metal bush of any size and make sutiable for ceiling fans 1200 compete all as specified and directed.
Supply only ball bearing No. 6202,
Supply only ball bearing No. 6203,
Supply only worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as directed.
S&F Ceiling fan blade suitable for 1200mm sweep of any make with suitable size as per site requirement complete all as specified and directed.
M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc.and endorsement of fan no.with black synthetic enamel paint complete all as directed.
Schedule of Credit
M/s SAAR ENGINEERS
SHREE RAM BUILD TECH
POONAM ENTERPRISES
a.k constructions
M/S MSD & Associate
GAUTAM ELECTRIC WORKS
Usha Contractors and Engineers
SAGAR ENTERPRISES
S D Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .