Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.0 LAccepted-AOC VILL SALDANGA P O RONDIA DIST BURDWAN PIN 713420 WB | RONDIA | BURDWAN | WEST BENGAL | 713420 | L1 | Accepted-AOC L1 | |
| 2 | L2₹71.1 L+₹2.2 L (3.17%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical KASHIPUR P O KASHIPUR DIST PURBA BURDWAN | HOOGHLY | WEST BENGAL | 712134 | - | Rejected-Technical Non- Responsive | |
| 4 | Rejected-Technical BANKURA BANKURA WEST BENGAL | - | Rejected-Technical Non- Responsive | |
| 5 | Rejected-Technical SRIBHUMIPALLY P O SURI DIST BIRBHUM PIN 731101 | SURI | BIRBHUM | WEST BENGAL | 731101 | - | Rejected-Technical Non- Responsive |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
21 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER DPMU BANKURA WBADMIP
ADMIN BUILDING WRIDD PRANABANANDA SARANI KENDUADIHI BANKURA 722102
Installation of Solar operated Low Duty Tube Well Schemes Hamirhati LDTW 978 Hamirhati LDTW 853 Hamirhati LDTW 99 Hamirhati LDTW 284 Hamirhati LDTW 229 Hamirhati LDTW 599 Hamirhati LDTW 978 at Hamirhati mouza under Sonamukhi block in the district of
2023_WRDD_492648_1
73/22-23/BANKURA/WBADMIP/PHASE II
Open Tender
CIVIL AND ELECTRICAL WORKS
Item Rate
180 days
BANKURA
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.6 L
Yes
9 Aug 2024
17 Mar 2023
25 Apr 2023
17 Mar 2023
21 Apr 2023
17 Mar 2023
17 Mar 2023 - 6 Apr 2023
Amount
Drilling of borehole by direct rotary rig through any kind of soil or rock down to required depth by using not more than 215 mm dia. drill bit including arrangement of water for the bore hole all complete.
(a) 0 mtr. to 30 mtr.
(b) 30 mtr.to 60 mtr.
(c) 60 mtr. to 90 mtr.
(d) 90 mtr. to 120 mtr.
Electrologging of bore hole of different dia tubewell for locating water bearing strata and saline aquifer, if any, after conducting relevant geophysical tests. All test reports, compiled data and raw data sheets should be submitted to the Engineer-in-Charge (Cost is inclusive of all charges for equipments, labour, data aquisition & compilation of data sheets as per direction of the Engineer-incharge)
Labour charges for fitting, fixing & jointing thread to thread with solvent cement the PVC. pipes (Housing pipe, Blank Pipes, Strainers, bottom plug etc.) and lowering the same carefully into the bore hole down to the required depth complete in all respects as per direction of the Engineer-in-charge
a) 150 mm DN dia. blank pipe, Bottom Plug & Screen/Slotted Pipe
b) 250 mm DN dia. Housing pipe
Casing Pipes ISI marked- IS 12818
b)150 mm dia. 7.5 mm-Medium
d) 150 mm dia. 7.5 mm thick Screen Ribbed (Medium)
E.R.W.Casing 7 Blank Pipe ISI marked-IS 4270 b)250 mm N.B.(7.1 MM)46.57 Kg/m
(ii) M.S. Centre guide (consisting of 3 nos., not less than 450 mm long and 125 mm rise of arch) of approved quality with two nos. MS clamps suitable for PVC- U pipes.
Supplying, fitting, fixing the following fittings of PVC-U conforming to IS:12818 & lowering in position etc. as directed by the Engineer-in Charge.
(iii) 150 mm DN PVC-U end cap.
Supply of gravel for use as packin tubewell of 2mm to 4mm. Size (as per IS:4097) and gravel treatment of tubewell including screening ,washing ,cleaning etc. of the gravels at the site, all complete as per direction of the Engineer-in-Charge
Washing and development by pumping with 30 cum per hour capacity pump for a period till sand free water comes out and the discharge is about 30 cum per hour, followed by final yield test; inclusive of all tools, plants and scaffolding and hire charge of submersible pump, generator etc. all complete
Hire charge of generators including accessories and operational personnels for aquifer parameter test including transporation, fuel, lubricant, electrical connections etc. complete ( 2 nos generators - one running & one stand by for uninterrupted power supply to be arranged for each site).
Hire charges of submersible pump sets of 100 cum/hr capacity, with column pipes, sluice valve, 900 bend, short piece, starter, mainswitch, cable etc. all complete as per instruction of Engineer-in-charge including testing equipments.
Labour charges for lowering the submersible pump set, column pipes with necessary accessories including fitting & fixing the same in the tubewell including proper electrical connection with generator all complete as per direction of Engineer-in-charge and also withdrawal of the same after completion of the test.
Collecting of sample of water for bacteriological & chemical test from any depth at any point of time during execution of works including hire & labour charges for tools and plants and sterilizing the equipments, paying all charges and fees towards testing by accredated Lab. etc. complete in all respects as per direction of the Engineer-in-charge.
(iii) M.S.Top cap of suitable size (6mm thick) and approved quality for covering top of housing pipe of 250 mm NB (Top cap will be tack welded with housing pipe at 4 points 90° apart).
Installation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controllerl starter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.) (b) 30 m3 per hour capacity electro motor pumping set.
(ii) Length of pump assembly of any length exceeding 18 metre length.
GI. Holding Clamp-IS 1239, Galv-IS 4736 c) 80 mm dia.
Solvent Cement
3C Flat water proof CU.cables lSI marked-IS 694 b) 3C X 2.5 sq. mm
P.V.C.Flexible Hose pipe, lSI marked -IS 15265 10. c) 100 mm dia lay Flat Hose (Non-lSI)
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (ii) 80 mm dia. medium quality
Brick Kiosk
Solar Module: Supply, transport, installation and commissioning of MNRE (Ministry of Renewable Energy,Govt. of India)/ IECapproved Solar Module of multicrystaline cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA)and high transmissivity 3.2 mm tempered glass, framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC,should be a minimum of 300 Watt peak,with adequate provision for measurement tolerances.Modules supplied with the Spy system should have certificate as per IEC61215 specification or equivalent National or International standards. Modules must qualify to IEC 61730 part I and part II for safety qualification testing and Salt Mist Corrosion Testingasper IEC61701/IS 61701 and having warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied. c) For 5 HP Off-grid Solar Water Pumping System with Monocrystalline / Monocrystalline PERC/bifacial spv modules -5600/5700 Wp. (Item No.1 Chapter 12,P-10)
Module Mounting Structure ( For 2HP, 3HP and 5HP Solar Water Pumping System): Supply , transportation & installation of G.I manual tracking structure made of MS hollow sections, pipes, plates, angles etc as per IS 1161/1239, 1079/2062, to hold min 300 Wp SPV Module as per drawing and specification of MNRE . The steel structure is to be protected with minimum 80 micron galvanisation(hot dip) and provided with dual axis manual tracking arrangement three times in a day and seasonal tilting are to be regulated to face the sun optimally. The weight of the Module Mounting Structure holding 4 Modules should not be less than 165 Kgs, holding 5/ 6 Modules should not be less than 235 Kg and holding 7/ 8 Modules should not be less than 265 Kg. (Item No.2 Chapter 12,P-10)
Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking Spy Module structure as per approved drawing. b) For 6 module structure having maximum capacity of 1950Wp
Powerconditioning unit including MPPT, Data logger and IP54enclosure: Supply , transport , installation and commissioning of IP S4 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 600682-Environment Standard , safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology,to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure.Inverter should have protection againstDry run, Overcurrent, Under current, Overvoltage, Undervoltage, Short circuit etc. Systemshould be able to run at low sunshineand minimum 7 to 8 hours a day run should be possible during normal sunshinecondition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation exceptfor dry run. Inverter should 4 be providedwith a display to show the various parameter by the user suchasVoltage, Current, Solar panel DC voltage, Inverter IGBTtemperature, Out put AC voltage, Output frequency, Pump flow (direct or calculatedmethod), Irradiation etc. The system should be capable to store the data at a set Interval and transfer it in a pendrive through USB port. It should also monitor and save total run time, total water pumped etc. There should be provision for interfacing GPRS based data transmission c) For 5 HP capacity Pump-motor set (Item No.3 Chapter 12,P-11)
Cableand Accessories: Supplying,fitting and fixings of UV rated Copper Cablel aid inside HOPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPTetc. I. 4.0 Sq mm single core multi studs - 5 m ( for 2 HP) & 20m for 3/5 HP) II. Lugs,HOPE Pipe,Flexible Pipe,Saddle,Cabletie etc c) For 5 HP per structure (Item No.4 Chapter 12,P-11)
Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWGGI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S& F 15 mm dia GI pipe protection (1 Mt. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an averagedepth of 3.65 Mts. below the ground level as below: By lSI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S &F 20' mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddlesas required and connection to equipments incl. drilling holes,with bolts, nuts, washers etc complete. (Item No.5 Chapter 12,P-11)
Lightning protection (Pole mounted): Lightning protection with 3" X1.5" G.I pipe of 4 mts height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (lSI Medium) having five discharge prongs of 4 SWGGI (Hot Dip) wire at top duly soldered with 7/16 stranded GI(Hot Dip) wire and 85 mrn dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/thimbles and S & F 40 mm dia GI pipe (lSI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (Provision of one lightning protection for each structure). (Item No.7a Chapter 12,P-12)
Supply and installation of 3 phase electro motor pump set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading,transportation etc. c) iii) Submersible Pump-motor set for LDTW ISI marked as per IS:8034 with dischargeof 7.5 tps- 5.83 Lpsat 30 mts.-40 mts. total head with cable (3m), bends,cover plate, Socket,flanged, Nipple, Rubber Insertion, Nuts & bolts and all other accessories Including transportation of bend, column pipes,Sluic valve, lay flat hose pipe etc. from Deptt. Store to site within 100 k.m. (Item No.8 Chapter 12,P-13)
Testing and commissioning of scheme after completion of all work. (Item No.9 Chapter 12,P-13)
Comprehensive maintenance charges for 4 years beyond 1 year warranty period (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time). c) For 5 HP both for Submersible & Surface pump. (Item No.10 Chapter 12,P-13)
Remote monitoring for 5 years: Supply & installation of GSM/ GPRS based Data Transmitter or Modem and to provide remote monitoring service to transmit the parameters to central server from the solar pumping system with time stamp at user defined interval and report generation at the buyer end. (Item No.11 Chapter 12,P-13)
Insurance @ 2% Item No. 22,25,28, and 30 for a period of 5 years. (Item No.12 Chapter 12,P-13)
Construction of Sign Board
SHYAM SUNDAR PAL
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .