| 1 | L1₹42.3 LAccepted-AOC MOHANBARI JEMES WARREN TINALI AIR PORT ROAD PO MOHANBARI ASSAM 786012 | DIBRUGARH | ASSAM | 786012 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹48.1 L+₹5.1 L (11.9%)Rejected-Finance AT ROAD NEAR MES TINALI PO CHABUA DIST DIBRUGARH ASSAM | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹48.7 L+₹5.7 L (13.4%)Rejected-Finance A T ROAD CHABUA NEAR ST LUKAS HOSPITAL PO CHABUA DIST DIBRUGARH ASSAM 786 184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹49.3 L+₹6.3 L (14.8%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹49.8 L+₹6.8 L (15.8%)Rejected-Finance NAV PUKHARI ROAD MILLAN PALLY PO DIST TINSUKIA ASSAM 786 125 | TINSUKIA | DIBRUGARH | ASSAM | 786125 | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
21 Aug 2023, 6:00 pmClosed
Ashish Yadav, IDSE, EE
Garrison Engineer AF Mohanbari Mohanbari Post Dibrugarh Assam 786012
SPECIAL REPAIR TO BLDG NO. T 25 AND T 26, PROVN OF 1 GUARD ROOM WITH TOILET, PROVN OF BATHING POINT WITH OVERHEAD PROTECTION AND A WATER TANK AT 764 ASC BN UNDER GE AF MOHANBARI
2023_MES_611267_1
8001/492/E8
Open Tender
Civil Works
Item Rate
270 days
Mohanbari
Please refer Tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Mohanbari
₹86,000
Yes
22 Sept 2023
31 Jul 2023
22 Aug 2023
31 Jul 2023
21 Aug 2023
14 Aug 2023
Amount
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and fair complete all as specified and directed.
M & L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces with water proofing compound and finishing the surface even and fair complete all as specified and directed. Note: water proofing compound shall be measured seprately.
Taking down plastering on lathing (other than wire netting), without removing lathing, but in cement lime or cement mortar(one side only measured in cases where both sides are plastered.
S& F in repair GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc in walls, ceilings, stanchions, beams etc including all laps, cutting and waste complete all as specified and directed.
M & L for rendering 20 (15+5)mm thick on the other side of lathing plastering in cement mortar 1:4 with complete framing with shuttering as one side fair and plastering with other side as fair finish form other side complete all as specified and directed.
M&L preparation of new plastered wall surfaces and including applying two coats of oil bound distemper over a coat of primer over wall care putty (1 to 2 mm thick) to obtain smooth finish complete all as specified and directed.
M&L preparation of old plastered wall surfaces and applying two coats of oil bound distemper over one coat of wall care putty (1 to 2 mm thick) to obtain smooth finish complete all as specified and directed.
M&L preparing of old plastered or un plastered surface of walls and applying two coats of cement base paint complete all as specified and directed.
M&L preparing of new plastered or un plastered surface of walls and applying two coats of cement base paint complete all as specified and directed.
Supply only Integral water proofing compound ISI marked complete all as specified and directed.
Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards / slabs / blankets, any thickness including cover fillet complete all as specified and directed.
S & F anodised aluminium snap grid frame work size 605x605 mm for false ceiling with hangers 6 mm dia G.I tube (up to 1200 mm length ) adjusting level fixed to roof slab by means of ceiling cleats made out of G.I flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 10 mm long including 6 mm thick E board classic ceiling with calcium cilicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600 mm grid fixed on grid after preparation of new surface of board with two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in Unframed work complete all as specified and directed.
M & L of 2nd class hard wood in scantling, clean sawn in any position and any description as in un-framed work complete all as specified and directed.
M & L for preparing surfaces of wood and wood based materials, new or old, of any description and girth and treated with two coats of creosote complete all as specified and directed.
Dismantling of corrugated or semi corrugated Asbestos Cement (AC) sheets in roof covering complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with or cranked hook bolts in lieu of self tapping screws complete all as specified and directed.
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, including gutter & valley or cranked hook bolts in lieu of self tapping screws complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below and above ground level) complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 15 mm thick in CM 1:6 complete all as specified and directed.
M & L for Coloured Glazed ceramic tiles 450 x 350 x 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 10mm thick redering in CM 1:4 on brick wall complete all as specified and directed.
M & L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) plinth protection etc laid in alternate pannel, surfaces finished even and smooth with using extra cement complete all as specified and directed.
Taking down or up 15 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Taking down or up 20 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
S & F 15 mm bore galvanised steel water tubing medium grade with and including all fittings and laid in trenches/wall complete all as specified and directed.
S & F 20 mm bore galvanised steel water tubing medium grade with and including all fittings and laid in trenches/wall complete all as specified and directed.
S&F in repairs 15 mm bore bib tap chromium plated fancy type, cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed.
S&F in repairs 15 mm bore fancy type, chromium plated, stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed complete all as specified and directed.
S&F in repairs pillar tap 15 mm bore, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without lettered “hot" or “cold” with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair vitreous china wash hand basin white flat back of size not less than 550 x 400 mm with and including PVC waste pipe 32 mm bore, CP waste fitting and cutting for and pinning in ends of brackets etc, complete all as specified and directed.
Supply and Fix in repairs 10 Litres, PVC, valve less, syphonic action type, Flushing Cistern, high level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long complete all as specified and directed.
Supply and fix in repairs vitreous china wash down water closet pedestal pattern white excluding flush pipe flushing cistern etc complete including connection to drain pipe and seat cover and to flushing pipe etc complete all as specified and directed.
S & F Ball 20mm brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S & F 500 litres capacity Rotational moulded polyethylene water storage tanks double layer (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including disconnectiong of existing tank and removing to store complete all as specified and directed.
S & F in repair Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flange complete all as specified and directed.
S&F in repair Toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S & F PVC connections 15mm size with PTMT nuts of length 450mm all as specified and as directed.
S & F of 75 mm dia PVC (SWR) Plain floor trap, with grating including jointing with solvent cement complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed.
S & F 100mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls or laid in floors/trenches complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 75 mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (Without taking off shutters from the frame) complete all as specified and directed.
Taking down Chowkats or frames n exceeding 1.5 Sqm each (Without taking off shutters from the frame) complete all as specified and directed.
Supply and fix for powder coated aluminium sliding windows two track with two sliding shutters with extrusions aluminium of following sections including jointing cleats, glazing clips, rubbr packaging, snap beading and other necessary builders hardware as required complete all as specified and directed. (A) FRAME:-(i) Top and side member for two track frame of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.784 kg/ mtr), Model No. 20829 of Jindal or equivalent as specified in PS. (ii) Bottom rail of frame for sliding of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.909 kg/ mtr), Model No. 20830 of Jindal or equivalent as specified in PS. (B) SHUTTER:-(i) Top and bottom rail of sliding shutter of size 40 mm x 18 mm x 1.5 mm (weight 0.547 Kg/ mtr), Model No. 20736 of Jindal or equivalent as specified in PS. (ii) Side of sliding shutter with handle and self locking arrangement, section of size 40 mm x 18 mm x 1.5 mm (weight 0.547kg/ mtr), Model No. 20738 of Jindal or equivalent as specified in PS. (C) Sliding shutter to be provided with 5.5 mm thick sheet glass complete all as specified and directed. (D) Supply & Fix for 6.5 mm thick powder coated aluminium diamond grill with mill finished fixing on wall/wooden chowkhat/ aluminium frame with suitable size of aluminium 'U' channel and steel chromium plated, screw with rawel plug complete all as specified and directed with following details:- (i) Aperture size of aluminium grill 67 mm x 84 mm. (ii) Cord dimension 7 mm x 5.8 mm. (iii) Plate thickness 2 mm. (E) Supply & Fix for Galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm fixed with galvanised wire staples/ clip/ aluminium flat, complete all as specified and as directed.
Solid PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC Sheet reinforced with MS Square tube manufactured as per SSR Part I specifications and drawing, and making good as per existing surface complete as specified and directed.
S & F Factory made solid panel PVC door shutter 30mm thick (style) manufactureed as per SSR Part I specifications and drawing, consisting of frame made out of MS Tubes for top and bottom rails. MS frame shall be sheet strip of 20mm width stuck inside with solvent cement for stiles and as gap insert for top rail & bottom rail. Panelling of plain solour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement at site complete as specified and directed.
M & L for Second class hard-wood in scantlings in framed work in repairs, to replace old and decayed timber (including piecing, scarfing, etc., of old and new timbers if required) and removing defective portions to store complete all as specified and directed.
S & F Roof trusses (framed), trussed, purlins crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) of Fe410-W (Gde E250) quality -B including distance pieces. Cleats etc complete all as specified and directed.
M&L for preparation of New or previously untreated steel surfaces based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide primer complete all as specified and as directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer primer complete all specified and as directed.
Preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint (Ordinary tint) complete all specified and as directed.
S&F butt hinges of size 100mm , extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all specified and as directed.
S & F 150 mm long aluminium handles, cast type, anodised complete all specified and as directed.
S & F 200 mm long mild aluminium anodised barrel tower bolt of extruded section complete all specified and as directed.
S & F 300mm long aluminium alloy, anodised sliding door bolts,plate type, stove enamelled black,with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all specified and as directed.
M & L for plain cement concrete 1:3:6 type D2 Nominal Mix (using 40 mm graded stone aggregate) as in surface channel or drain or benching in manhole complete all as specified and directed.
M & L for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitered / stopped ends etc. complete all as specified and directed.
S&F steel ventilator with top hung shutter and including hinges steel peg stay complete all as specified and directed.
S & F of 4 mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in square not exc. 0.5 Sqm in each pane complete all as specified and directed.
S & F of pressed steel frame of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc., complete all as specified and directed.
S&F 35mm thick factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated etc., complete all as specified and directed.
S&F 30mm th, factory made 2nd class HW glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations etc. or for shafts, well cess pits, manholes,pier holes,etc. but not exceeding 10 sqm on plan getting out in soft/loose soil complete all as specified and directed
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removal of excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Material and labour RCC M25 (Design mix) using 20mm graded aggregate, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed. (Design mix will be used as already approved by GE as in same stn.)
Material and labour RCC M25 (Design mix) using 20mm graded aggregate, including Columns, pillars, piers, Chajjas, posts and struts etc. complete all as specified and directed. (Design mix will used as already approved by GE as in same stn.)
Material and labour RCC M25 (Design mix) using 20mm graded aggregate, including Beams, cantilevers, bressummers, lintels over 1.5m span etc. complete all as specified and directed. (Design mix will used as already approved by GE as in same stn.)
Use and waste of formwork to sides of concrete foundations, footings, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces all as specified and directed.
Use and waste formwork to sides of pillars,posts, struts, piers, columns, Chajjas etc and stanchions for fair finish surfaces in rectangular, square or pentagolnal all as specified and directed.
Use and waste formwork to sides and soffits of floor or roof beams, lintels, including supports, overhangs, etc. also splays between floors and beams, etc.for fair finish of flat surface all as specified and directed.
M&L for damp proof course of 40mm thick PCC 1:2:4 type B0 by using Polythene film, black, 50 micron laid in floors over applied Bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5kg per sqm per coat complete all as specified and directed.
M&L TMT steel bars, as in reinforcement, 10 mm dia and over, cut to length, bent to shape required, including cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed.
All as Item above here in before but 6-8 mm dia and over as in stirrups, spacers and binders etc complete all as specified and directed.
M & L for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as directed.
M&L treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface all as specified and directed by Engineer-in-charge.
M&L treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as specified and directed by Engineer-in-charge.
M & L for treatment of the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C1 using 20mm thick graded stone aggregate as in plinth protection all as specified and directed.
S&F for Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, base plates. splices, angle brackets, cleats and other connections confirming to Fe 410 -W (Gde?E- 250) quality-B complete all as specified and directed.
S & F 4.8 mm thick sheet glass ordinary quality in squares n.exe 0.50 sqm in each, complete all as specified and directed by Engineer-in-charge
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples all as specified and as directed
S&F framed work such as grills, gratings, etc with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290,Gde-E-165, all complete as per requirement and direction of Engineer-in-charge.
M & L for preparation of newly plastered surfaces of wall and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed.
Material and labour for PCC 1:3:6 type C2 using 40 mm graded stone aggregate for concrete bed to 150mm dia pipe incl packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
M&L PVC (SWR) pipes 150mm single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
Material and labour for providing, cement concrete type B1 1:2:4 using 20mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L extra for forming fair finished channel or drain of 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred stopped ends etc all as specified and directed.
Materials and labour for pre cast cement concrete (1:2:4) Type B1, using 20mm graded crushed stone aggregates in cover slabs, set in cement mortar 1:4 with plain faces, complete all as specified and directed by Engineer-in-Charge. Note: - Reinforcement steel shall be measured and paid separately under appropriate item of Schedule 'A' complete all as specified and directed.
S & F vitreous china squatting pan orissa pattern size 580x440mm white with integral foot rest including P or S trap and concrete for necessary fixing complete all as specified and directed.
Septic tank for 10 users On site LLDPE septic tank designed with upflow filter including media to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and as directed by Eng -in -charge.
M&L 75mm thick Plain cement concrete type D-2, 1:4:8 using 40mm graded aggregate as in sub base of floor, hardstanding and Pavings, etc. complete all as specified and as directed.
M&L 25mm thick Plain cement concrete type B-2, 1:2:4 using 20mm graded aggregate as in base of floor , hardstanding and Pavings, etc. complete all as specified and as directed.
M&L for Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6 complete as specified and directed.
M&L cement concrete chequered tiles 200 x 200 x 25 mm thick as in floors, set and jointed in grey cement and pigments to match the colour of tile including dismantling complete all as specified and directed.
M & L for plain cement concrete 1:2:4 Nominal Mix (using 20 mm graded stone aggregate), as in lintels upto 1.5 m clear span, cills, steps,seismic and other similar bands, plinth course, string courses, lacinng courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
S&L rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides confirming to Fe-410-W(Gde E-250) quality B fixed with angle cleats or other connecting plates complete as specified and directed.
Excavating in post holes of soft/loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cmcomplete as specified and as directed.
M&L for Plain cement concrete type 1:3:6 type C2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
S&F of 20 mm dia gun- metal globe or gate valves, with iron wheel head screwed both ends for iron pipe & fixed in repair, complete all as specified and directed.
M&L for providing Cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in benching of surface channels and drains all as specifie and directed.
S&F 15 mm bore bib tap chromium plated fancy type, cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed.
S&F 15 mm bore fancy type, chromium plated, stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed complete all as specified and directed.
S&F pillar tap 15 mm bore, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without lettered “hot" or “cold” with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F vitreous china wash hand basin white flat back of size not less than 550 x 400 mm with and including PVC waste pipe 32 mm bore, CP waste fitting and cutting for and pinning in ends of brackets etc, complete all as specified and directed.
Supply and Fix 10 Litres, PVC, valve less, syphonic action type, Flushing Cistern, high level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long complete all as specified and directed.
S & F 500 litres capacity Rotational moulded polyethylene water storage tanks double layer (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
Taking down carefully copper/aluminum point wiring (light ,fan and power socket etc) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets etc removing materials for unserviceable material to taking credit and serviceable material to shifitng to MES store for reuse at site and making good matching to the existing colour to the disturbed surface wall/ floors etc. complete all as specified and directed.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody or for taking credit, cutting chasing as required and making good the disturbed surfaces including finishes to match with adjacent surfaces of walls, floors, etc. complete all as specified and as directed.
M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC casing caping (medium grade) with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one 5 Amps switch socket combination on independent board and including cutting chasing (as required) and making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed.
M&L point wiring with 2.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC casing caping (medium grade) with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one 15 Amps switch socket combination on independent board and including cutting chasing (as required) and making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed.
M&L point wiring with 4.0 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC casing caping (medium grade) with and including 4.0 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one metal clad socket for AC/Geyser and including cutting chasing (as required) and making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed.
Material and labour for sub main wiring with two run of 6.0 sqmm PVC insulated unsheathed FLRS copper conductor single core multi stranded and one run of insulated copper earth wire 6.0 Sqmm drawn through medium grade PVC casing and caping of suitable size complete including taking down old one complete all as specified and as directed. Note :- Copper conductor 3 run of 6 sqmm and one run PVC casing caping shall be measured as one unit
M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) of suitable size with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch and including cutting chasing (as required) and making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed.
Ditto all as per item No.132 here in before but for one 5 Amp SS combination on same board.
Material and labour for sub main wiring with two run of 4.0 sqmm PVC insulated unsheathed FLRS copper conductor single core multi stranded and one run of insulated copper earth wire 4.0 Sqmm drawn through medium grade PVC casing and caping of suitable size complete including taking down old one complete all as specified and as directed Note :- Copper conductor 3 run of 4 sqmm and one run PVC casing caping shall be measured as one length.
Supply and fixing modular switch 1 way 6 /10 Amps,230 volts, 50 HZ complete all as specified and as directed
Supply and fixing modular switch 1 way 16 /20 Amps,230 volts, 50 HZ complete all as specified and as directed
Supply and fixing modular bell push switch 1 way 6 /10 Amps,230 volts, 50 HZ complete all as specified and as directed
Supply and fixing modular socket 6 /10 Amps,230 volts, 50 HZ complete all as specified and as directed
Supply and fixing modular socket 16 /20 Amps,230 volts, 50 HZ complete all as specified and as directed
S&F stepped type electronic fan regulator two module, with 5 step, AC 50 Hz 240 Volts grade complete all as specified and directed.
Supply and fixing ceiling rose surface type Bakelite 3 terminals complete all as specified and directed.
Supply and fixing calling bell ding dong type AC 230 Volt complete all as specified and directed.
S&F white cover plate with frame 2 module complete all as specified and directed.
S&F white cover plate with frame 3 module complete all as specified and directed.
S&F white cover plate with frame 6 module complete all as specified and directed.
S&F white cover plate with frame 8 module complete all as specified and directed.
S&F metal Flush Box 2 module complete all as specified and directed.
S&F metal Flush Box 3 module complete all as specified and directed.
S&F metal Flush Box 6/8 module complete all as specified and directed.
Supply and fix in repairs for sheet metal enclosure single pole and neutral with two pin and earth plug complete with one single pole MCB 20 amps, 230 volts complete all as specified and directed.
S&F sheet metal enclosure MCB DB TPN double door type AC 415 V 4 way with 200 Amps rated bus bar, vertical/horizantal type including taking dwon old one complete and making good of distructed surface complete.
S&F sheet metal enclosure MCB DB SPN single door type AC 240 V 12 way with 200 Amps rated bus bar, vertical/horizantal type including taking dwon old one complete and making good of distructed surface complete.
S&F sheet metal enclosure MCB DB SPN single door type AC 240 V 8 way with 200 Amps rated bus bar, vertical/horizantal type including taking dwon old one complete and making good of distructed surface complete.
S&F MCB TPN 63 Amp, 10 kA, 240V 'C' curve complete all as specified and as directed.
S&F MCB SPN 40 to 63 Amp, 10 kA, 240V 'C' curve complete all as specified and as directed.
S&F MCB SPN 10 to 32 Amp, 10 kA, 240V 'C' curve complete all as specified and as directed.
S&F MCB SP 6 to 32 Amp, 10 kA, 240V 'C' curve complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in repairs of bulk head luminaire environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge -lit LED luminaire comprising of high brightness LEDs 10 watt, 230 volts, 50 Hz including lamp, connection wire all as specified and directed.
S&F in repairs of slim, compact, aluminium die cast edge lit panel, recess mounted round fixture with opal diffuser and separate electronic driver 15 watt, 230 volts, 50 Hz including lamp, connection wire all as specified and directed
S&F in repairs of recessed mounted 36 watt (clear white) LED panel light 600 mm X 600 mm, ultra slim design, 230 volts, 50 Hz with CRCA sheet housing precoated white colour and high quality diffuser for uniform light and high efficiency with separate replaceable electronic driver including lamp complete all as specified.
Material and Labour in repairs /replacement earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire of 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point and including dismantling complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC casing caping (medium grade) with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch and including cutting chasing (as required) and making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed.
Ditto all as per item No.164 here in before but for one 5 Amp SS combination on same board.
S&F switch piano flush type 5/6 Amps, 230 volt, one way, single pole complete all as specified.
S&F socket 5 pin, multipurpose type, 5 Amps, piano flush type, 230 V complete all as specified.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed.
S&F bulk head luminaire environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs 10 Watt, 230 Volts, 50 Hz including lamp, connection wire all as specified and directed.
S&F in repair of ultra slim LED batten 10 Watt, 230Volts, 50 Hz, decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly including lamp, connection wire all as specified and directed. Make: Crompton Cat Part No. LDL-10-CDL/ Philips Cat Part No. BN 021 LED10S- 6500 PSU GR S1 or equivalent in GE.
M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing water pipe line upto 25mm all as specified and directed.
Supply and laying 3 layer PP-R polypropylene random copolymer concealed pipes 25 mm outer dia SDR 7.4 (PN 16),UN stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain and brass threaded polypropylene random fitting laid in trenches/wall including all fittings all as specified and directed.
Cutting of existing GI pipe 50 mm in position for insertion and including of new tee of size 50x50x25 mm complete all as specified and as directed
Supply & fixing PPR Gate Valves (Brass insert) of 25 mm outer dia complete all as specified and directed.
Material and labour for construction of valve pit chamber of internal dimension 40 x 40 x 40 cm with sub class 'B' bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8), type D2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6), type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 5 mm angle iron and 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, two coats of white wash on plastered surface (exposed to view) including necessary excavation in soft/ loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50m.
M&L sand cushioning with clean and dry sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.
Material and labour for laying Sub class B brick locally available of size 230mmx115mmx75mm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
Supply and laying pipes galvanized iron light grade with all fittings for cable protection of size 40mm bore complete all as specified and directed.
Supply and lay cable XLPE insulated XLPE screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 violts grade with stranded aluminium conductor of size 2 core 25 sqmm complete all as specified and directed.
M/S RK Trading
M/s Sashi Enterprise
KP GHOSH AND CO
M/s Pramillabh Construction
M/S N K SAI TRADING
M/S P R SINGH AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .