Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹24.6 L+₹11,467 (0.47%)Rejected-Finance | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹24.6 L+₹12,530 (0.51%)Rejected-Finance NEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹25.0 L+₹49,980 (2.04%)Rejected-Finance | L4 | Rejected-Finance Not become lowest bidder | |
| 5 | L5₹25.2 L+₹77,393 (3.16%)Rejected-Finance | L5 | Rejected-Finance Not become lowest bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 Oct 2021, 6:00 pmClosed
Major Deepak Kumar
Garrison Engineer Jhansi
REPAIR/MAINT AND RENEWALS TO CERTAIN E/M WORKS IN AIRFIELD AREA AT 664 ARMY AVN UNIT UNDER AGE EM AT GE JHANSI
2021_MES_475567_2
GE/JHA/TOK/55 OF 2021-2022
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE Jhansi
₹50,000
Yes
13 Dec 2021
19 Oct 2021
29 Oct 2021
19 Oct 2021
27 Oct 2021
22 Oct 2021
Amount
M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG, with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass /GI screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for the following points:-
One light point/Exhaust fan/Ceiling fan/Call Bell point controlled by one switch
One 6A socket point controlled by one switch on independent board
One 6A socket point controlled by one switch on same board
All as per srl item No. 1.00 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
M&L for Circuit/submain wiring alongwith earth wire 2 runs x 6 sqmm + 1 run x 6 sqmm with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
All as per srl item No. 3.00 here-in-before but 2runsX4 Sqmm +1runX4Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
All as per srl item No. 3.00 here-in-before but 2runsX2.5 Sqmm +1runX2.5Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
All as per srl item No. 3.00 here-in-before but 2runs1.5 Sqmm +1runX1.5 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
Notes for item No. 1.00 to 6.00 (i) Quoted rate shall deemed to incude the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & caping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing caping may be used in that portion.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed.
Supply and fix in replacement of switch piano flush type 6 Amps, one way, 240V, 50Hz including taking down existing unserviceable switch of any description complete all as specified and directed.
Supply and fix in replacement of socket 6 Amps, 2-in-1 flush type universal 240V, 50Hz including taking down existing unserviceable socket of any description complete all as specified and directed.
Supply and fix in replacement of switch piano flush type 16 Amps, one way, 240V, 50Hz including taking down existing unserviceable switch of any description complete all as specified and directed.
Supply and fix in replacement of socket 16A & 6A, 2-in-1 flush type universal 240V, 50Hz including taking down existing unserviceable socket of any description complete all as specified and directed
Supply and fix in replacement of Lamp holder, angle type with metal ring, PVC/Polycarbonate body including taking down existing unserviceable lamp holder of any description complete all as specified and directed.
Supply and fix in replacement of electronic fan regulator rotary type in 5 steps, 240V, 50Hz including taking down existing unserviceable fan regulator of any description complete all as specified and directed.
Supply and fix in replacement of ceiling rose 6 Amps, 3 terminal, 240V, 50Hz including taking down existing unserviceable ceiling rose of any description complete all as specified and directed.
Supply and fix in replacement of bell push switch flush type 6 Amps, 240V, 50Hz including taking down existing unserviceable bell push of any description complete all as specified and directed.
Supply and fix in replacement of call bell ding dong, AC, 240V, 50Hz including taking down existing unserviceable call bell of any description complete all as specified and directed.
Supply and fix in replacement of modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 25A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of recessed mounted LED panel light 2'x2' size, 35 / 36 watts, full white / warm white with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for Amstrong / grid false ceiling complete fix fixing accessories including taking down existing unserviceable light fitting of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of LED batten with CRCA sheet steel box type body pre-wired suitable for and including provision of 1x20 Watt (4 feet) retrofit LED tube with PC body, full white and connecting up with twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of integrated LED batten 9/10 watt, 2 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of LED bulkhead luminaire in die-cast aluminium alloy body heat resistant prismatic glass cover, with specially designed gasket for minimum IP 55 degree of protection suitable for and including provision of 10W retrofit LED bulb, full white with B22 lamp holder complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of sleek round recessed cum surface mounting LED down light 12 W with aluminium die-cast body, finish with drop down PC diffuser warm / full white with optimized heat sink for efficient dissipation including taking down existing unserviceable light fitting of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Decorative wall light fixture made up of Polycarbonate with and including 7W retrofit LED lamp, full white / warm white of approved model complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of integrated LED batten 20 watt, 4 feet long, full white / warm white shade in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Post top lantern Black ABS plastic spigot, spun aluminium canopy, with clear acrylic diffuser and accessories along with LED lamp 9 Watt (warm white) with B22 base lamp holder including taking down existing unserviceable post top lantern fitting of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of LED street/security light fitting 35 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No. 26 here-in-before but 90Watts
Supply and fix in replacement of ventilating fan with plastic body with louvers, 200/250mm sweep, single phase, 230 volts, 50 Hz. complete all as specified and directed.
Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size 9" X 11" including necessary cutting, drilling holes for fixing of switches, sockets & fan regulators etc and fixing the hylam sheet on existing metal flush box with brass/GI screws with washers complete all as specified and directed by Engineer-in-Charge. Note: S&F of switches, sockets & regulators shall be measured and paid separately.
Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size 8" X 5" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws with washers complete all as specified and directed by Engineer-in-Charge. Note: S&F of switches, sockets & regulators shall be measured and paid separately.
Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size 5" X 5" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws with washers complete all as specified and directed by Engineer-in-Charge. Note: S&F of switches, sockets & regulators shall be measured and paid separately.
Supply and fix in replacement of MCCB / MCB distribution board, Vertical TPN, 6 way with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed by Engineer-in-Charge. Note: MCCB / MCBs shall be measured and paid separately.
Supply and fix in replacement of MCB distribution board, TPN, 4 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separately.
Supply and fix in replacement of MCB distribution board, SPN, 12 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separately.
Supply and fix in replacement of MCB distribution board, SPN, 8 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separately.
Supply and fix in replacement of MCB distribution board, SPN, 4 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separately.
Supply and fix in replacement of MCCB 125A, 16 KA, 4 Pole, 415 V, 50 Hz with fixed thermal magnetic release complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCB 63A, 10 KA, TPN, 415 V, 'C' curve, 50 Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCB 63A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz complete all as specified and directed by Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed, 25 sq mm 3.5 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc including taking down existing service cable of any description complete all as specified and directed.
All as per srl item no. 41 here-in-before but of size 16 sqmm 4 core
All as per srl item no. 41 here-in-before but of size 10 sqmm 2 core
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of GI Pipe and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 dia mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe, earth wire upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Supply and fix in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor twin core, 10 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections including connecting on LT OH line / energy meter / DB etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully the ceiling fan of any size 1200mm / 1400mm sweep, sealing cable end, dismantling blades and removing fan and blades to store for servicing including supply and replacing of bearings/bushings, capacitor and terminal connector including capacitor holder suitable for any model of existing fan etc and Hanging ceiling fan in its existing or new location and connecting up including provision of cable from ceiling rose to connector of fan and testing for satisfactory functioning complete all as specified and directed by Engineer-in-Charge. Note: Rewinding if required shall be measured and paid separately.
All as per item No. 50.00 here-in-before but of exhaust fan of any size up to 450mm sweep. Note: Rewinding if required shall be measured and paid separately.
All as per item No. 50.00 here-in-before but of Air Circulator of any size up to 600mm sweep. Note: Rewinding if required shall be measured and paid separately.
Material and labour for Rewinding of Ceiling Fan of size 1200mm / 1400mm sweep by shifting to workshop, cutting and removing of old burnt/damaged winding, cleaning of slots and other parts and rewinding the ceiling fan motor with super enameled copper winding wire of existing gauge with suitable class of insulation, applying varnish, heating, drying, assembling and testing for satisfactory performance complete all as specified and directed by Engineer-in-Charge.
All as per item No. 53.00 here-in-before but exhaust fan of size up to 450mm sweep.
All as per item No. 53.00 here-in-before but Air circulator of size up to 600mm sweep.
Taking up or down steel tubing and connections, including cleaning for refixing or taking credit complete all as directed for the following pipe sizes:-
15mm dia size
20mm dia size
25mm dia size
40mm dia size
50mm dia size
80mm dia size
100mm dia size
M&L for GI water tubing, medium grade, ISI marked, with and including all fittings i.e. bend, tee, elbow, reducer, union, nipple etc as per site requirement laid in trenches/floor or on wall, complete as specified and directed for the following pipe sizes:- Note : 1. The excavation & earthwork shall be measured & paid for separately. 2. The cost of all type of GI fitting i.e. bend, tee, elbow, reducer, union, nipple etc is deemed to be included in quoted rates.
15mm dia size
20mm dia size
25mm dia size
40mm dia size
50mm dia size
80mm dia size
100mm dia size
Supply and fixing MS clamp made out of 75mm x 5mm with 20mm dia hole for taking branch connection with and including fixing of 25mm dia GI socket duly welded complete including fixing of clamp on existing GI pipe line of size 80/100mm dia with suitable rubber gasket packing to ensure leak proof joint and suitable nuts, bolts and washers etc complete all as specified and directed by Engr-in-charge.
M&L for cutting of existing road / hard standing up to 15 cm depth for laying of pipes, and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 after laying of pipes and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items.
S&F Gun-metal gate valves, with iron wheel head, screwed both ends for iron pipe including taking down existing unserviceable gate valve of any description complete all as directed for the following sizes:-
80mm dia NB
50mm dia NB
40mm dia NB
25mm dia NB
20mm dia NB
15mm dia NB
Supply and fix in replacement Cast Iron sluice valve of size 100mm dia bore, having pressure rating PN 1.0, double flanged, non-rising stainless steel spindle with iron wheel conforming to IS:14846-2000 with jointing material ie new rubber gasket, nuts & bolts, washer etc of suitable size incl taking down old unserviceable sluice valve complete all as specified and directed.
M/s Raghav Traders
M/S Ritu Tandon
M/S RAJENDRA KUMAR AGARWAL
M/S MUKESH AGARWAL
M/S Kumar Contractors
M/s Ravi Traders
M/S Chadha Brothers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .