Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 CrAccepted-AOC D 2 3 RAJAT APARTMENT SENAPATI BAPAT ROAD SHIVAJI NAGAR PUNE 411016 | PUNE | MAHARASHTRA | 411016 | ₹15.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹16.2 CrRejected-AOC HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | ₹16.2 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹16.4 CrRejected-AOC OFFICE NO 515 PLOT NO 194 NMS ICON SECTOR 19 ULWE NAVI MUMBAI MAHARASHTRA 410206 | NAVI MUMBAI | THANE | MAHARASHTRA | 410206 | ₹16.4 Cr | L3 | Rejected-AOC L3 |
Tender Value
₹15.0 Cr
EMD Value
₹7.5 L
Closing Date
9 Aug 2024, 6:00 pmClosed
Executive Engineer Public Work(East)Division Pune
Executive Engineer Public Work(East)Division Pune
CONSTRUCTION OF THIRD AND FOURTH FLOOR(5 COURT HALLS) AT NEW COURT BUILDING AT SHIRUR (GHOD NADI), TAL.SHIRUR, DIST.PUNE
2024_PWDRP_1063337_1
E Tender Notice No.39 for 2024-2025
Open Tender
Civil Works - Buildings
730 days
Shirur
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
₹7.5 L
Chief Engineer, P. W. Region Office, Pune
26 Oct 2024
2 Aug 2024
12 Aug 2024
2 Aug 2024
9 Aug 2024
2 Aug 2024
2 Aug 2024 - 5 Aug 2024
5 Aug 2024
Amount
Providing and laying cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Third Floor
Providing and laying cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Fourth Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Third Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Fourth Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Third Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Fourth Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Third Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Fourth Floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ).Third Floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ).Fourth Floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).Third Floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).Fourth Floor
Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Ground Floor
Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Third Floor
Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Fourth Floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying/ pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing Autoclaved Areated Concrete block masonary of Ecolite or equivalent make conforming to IS:2185(Part 3)- 1984 in extra fine jointing mortor of fixoblock of UltraTech or equivalent in superstructure including striking joints, racking out joints watering and scaffolding complete.Third Floor
Providing Autoclaved Areated Concrete block masonary of Ecolite or equivalent make conforming to IS:2185(Part 3)- 1984 in extra fine jointing mortor of fixoblock of UltraTech or equivalent in superstructure including striking joints, racking out joints watering and scaffolding complete.Fourth Floor
Providing Autoclaved Areated Concrete block masonary of Ecolite or equivalent make conforming to IS:2185(Part 3)- 1984 in extra fine jointing mortor of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, racking out joints watering and scaffolding complete.Third Floor
Providing Autoclaved Areated Concrete block masonary of Ecolite or equivalent make conforming to IS:2185(Part 3)- 1984 in extra fine jointing mortor of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, racking out joints watering and scaffolding complete.Fourth Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete.Third Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete.Fourth Floor
Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.Third Floor
Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.Fourth Floor
Providing internal cement plaster 6 milimetre thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.Third Floor
Providing internal cement plaster 6 milimetre thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.Fourth Floor
Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete.Third Floor
Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete.Fourth Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete.Third Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete.Fourth Floor
Providing and applying laying Aggregate plaster in granite/ marble stones, as decorative finish to give granite/ marble like appearance to concrete, brick or block surfaces in all position including preparation of surface smoothly, evenly by racking of joints in case of Brick or block work including backing layer of 12 milimetre thick with cement mortar 1:3 with 2 percent integral cement water proofing compound, roughening for wall keying hardening and drying the surface for a minimum five days gaps including second coat of cement lime mortar into a proportion 1:4 preparing the surface for three coat of marble finish plaster giving a thin coat of white cement and two parts of course calcite powder, applying the mortar with steel float on the surface in proper evenness applying at coat of white cement and lime to set a smooth finish then applying a thin coat of slurry made of white cement and black oxide colour in required proportion by the steel float to get black streaks on the surface and curing the surface for two days including all materials and labour etc. complete.Third Floor
Providing and applying laying Aggregate plaster in granite/ marble stones, as decorative finish to give granite/ marble like appearance to concrete, brick or block surfaces in all position including preparation of surface smoothly, evenly by racking of joints in case of Brick or block work including backing layer of 12 milimetre thick with cement mortar 1:3 with 2 percent integral cement water proofing compound, roughening for wall keying hardening and drying the surface for a minimum five days gaps including second coat of cement lime mortar into a proportion 1:4 preparing the surface for three coat of marble finish plaster giving a thin coat of white cement and two parts of course calcite powder, applying the mortar with steel float on the surface in proper evenness applying at coat of white cement and lime to set a smooth finish then applying a thin coat of slurry made of white cement and black oxide colour in required proportion by the steel float to get black streaks on the surface and curing the surface for two days including all materials and labour etc. complete.Fourth Floor
Providing and applying Royale Luxury Emulsion of Asian/ Berger/ Nerolac/ Dulux Paints or equivalent make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller (With prior approval of S.E.).Third Floor
Providing and applying Royale Luxury Emulsion of Asian/ Berger/ Nerolac/ Dulux Paints or equivalent make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller (With prior approval of S.E.).Fourth Floor
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces.(excluding the primer coat.) complete.Third Floor
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces.(excluding the primer coat.) complete.Fourth Floor
Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (Heat Reflective Paint).Third Floor
Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (Heat Reflective Paint).Fourth Floor
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqare metre per kilogram with two coats using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.Third Floor
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqare metre per kilogram with two coats using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.Fourth Floor
Providing water proof bedding for flooring of bath and water closet, 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.Third Floor
Providing water proof bedding for flooring of bath and water closet, 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.Fourth Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at 1 kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.Third Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at 1 kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.Fourth Floor
Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete.Third Floor
Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete.Fourth Floor
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.Third Floor
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.Fourth Floor
Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.Third Floor
Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.Fourth Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.Third Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.Fourth Floor
Providing and laying vitrified matt fininsh tiles for flooring having size 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.Third Floor
Providing and laying vitrified matt fininsh tiles for flooring having size 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.Fourth Floor
Providing and laying vitrified matt finish tiles for Skirting having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 mm thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Third Floor
Providing and laying vitrified matt finish tiles for Skirting having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 mm thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Fourth Floor
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and conforming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.Third Floor
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and conforming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.Fourth Floor
Providing and laying ceramic tiles having size 30 centimetre x 60 centimetre for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.Third Floor
Providing and laying ceramic tiles having size 30 centimetre x 60 centimetre for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.Fourth Floor
Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.Third Floor
Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.Fourth Floor
Providing and fixing Modular false ceiling of 600 x 600 milimetre center to center and 13 milimetre thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2”x1 ½” (50 milimetre x 40 milimetre) weighing 0.39 kilogram per metre at 60 centimetre center center and fixed with ½” x ½” (15 x 15 milimetre) flanges weighing 0.19 kilogram per metre suspended on 6 milimetre diameter mild steel rod weighing 0.22 kilogram per metre, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1 ½” (50 milimetre x 40 milimetre) weighing 0.39 kilogram per metre etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete.Third Floor
Providing and fixing Modular false ceiling of 600 x 600 milimetre center to center and 13 milimetre thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2”x1 ½” (50 milimetre x 40 milimetre) weighing 0.39 kilogram per metre at 60 centimetre center center and fixed with ½” x ½” (15 x 15 milimetre) flanges weighing 0.19 kilogram per metre suspended on 6 milimetre diameter mild steel rod weighing 0.22 kilogram per metre, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1 ½” (50 milimetre x 40 milimetre) weighing 0.39 kilogram per metre etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete.Fourth Floor
Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete. Third Floor
Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete. Fourth Floor
Providing and fixing mild steel grill door 24 kilogram per squaremetre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etcThird Floor
Providing and fixing mild steel grill door 24 kilogram per squaremetre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etcFourth Floor
Providing and fixing the country cut teak wood double or single leaf second class fully pannelled door shutter with 35 milimetre thick style and rail with 25 milimetre thick pannels with openable fan light as per detailed drawings. Excluding the door frame 60 milimetre x 100 milimetre, including stainless steel fixtures and fastening and finishing the wood work with oil panting 3 coats.Fourth Floor
Providing and fixing 34 milimetre thick moulded door shutter consisting of solid core single leaf flush door of 30 milimetre thickness lipped with 15 milimetre (5 milimetre x 3) thick x 30 milimetre width on one style and top rail and 10 milimetre (5 milimetre x 2) thick x 30 milimetre width on other style and bottom rails. The inner panels laminated with 2 milimetre thick termite proof, water proof and fire resistant moulded Poly Venyl Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 milimetre plain and /or pre lam Poly Venyl Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Poly Venyl Chloride lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete.Third Floor
Providing and fixing 34 milimetre thick moulded door shutter consisting of solid core single leaf flush door of 30 milimetre thickness lipped with 15 milimetre (5 milimetre x 3) thick x 30 milimetre width on one style and top rail and 10 milimetre (5 milimetre x 2) thick x 30 milimetre width on other style and bottom rails. The inner panels laminated with 2 milimetre thick termite proof, water proof and fire resistant moulded Poly Venyl Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 milimetre plain and /or pre lam Poly Venyl Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Poly Venyl Chloride lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete.Fourth Floor
Providing and Fixing 30 milimetre thick both side Prelaminated Solid Panel Poly Venyl Chloride Door Shutter consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 milimetre for styles and 15 x15 milimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Venyl Chloride ' C ' channel made from 5 milimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles and 5 milimetre thick, 95 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered in 45 degree angle on the inner side to form top and bottom rail and 115 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/- 0.25) thick Poly Venyl Chloride strip of 20 milimetre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 milimetre (+/- 0.25) thick Poly Venyl Chloride sheet to be fitted inside the mild steel frame welded/ sealed to the styles and rails with 5 milimetre (+/- 0.25) x 30 milimetre Poly Venyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc ,10 milimetre thickness (5 milimetre (+/- 0.25) x 2 nos ) 20 milimetre wide cross Poly Venyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos mild steel powder coated but hinges of size 100 milimetre x 25 milimetre x 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 milimetre size steel screws including fixture fasting complete as per direction of engineer -in -charge.Third Floor
Providing and Fixing 30 milimetre thick both side Prelaminated Solid Panel Poly Venyl Chloride Door Shutter consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 milimetre for styles and 15 x15 milimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Venyl Chloride ' C ' channel made from 5 milimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles and 5 milimetre thick, 95 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered in 45 degree angle on the inner side to form top and bottom rail and 115 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/- 0.25) thick Poly Venyl Chloride strip of 20 milimetre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 milimetre (+/- 0.25) thick Poly Venyl Chloride sheet to be fitted inside the mild steel frame welded/ sealed to the styles and rails with 5 milimetre (+/- 0.25) x 30 milimetre Poly Venyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc ,10 milimetre thickness (5 milimetre (+/- 0.25) x 2 nos ) 20 milimetre wide cross Poly Venyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos mild steel powder coated but hinges of size 100 milimetre x 25 milimetre x 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 milimetre size steel screws including fixture fasting complete as per direction of engineer -in -charge.Fourth Floor
Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating with box.Third Floor
Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating with box.Fourth Floor
Providing and fixing in position (as per I.S.1868:1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 x 31.75 x 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 x 31.75 x 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre. Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts etc, complete with powder coating with box.Third Floor
Providing and fixing in position (as per I.S.1868:1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 x 31.75 x 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 x 31.75 x 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre. Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts etc, complete with powder coating with box.Fourth Floor
Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineer in Charge with all necessary aluminium sections including necessary fixtures and fastening with 5 milimetre thick clear float glass etc. complete.a) Without powder coating Fourth Floor
Providing and fixing in position anodised (as per IS1868/1982) Aluminium fixed staggered (Z Type) Ventilator with Aluminium rectangular pipe 63 mm. x 38.10 milimetre x 1.33 milimetre at weight 0.650 kilogram per running metre, Aluminium angle of size 15 milimetre x 15 milimetre x 1 milimetre, aluminium channel of 9 milimetre sizes, stainless steel mosquito net of 304 Grade, 4 milimetre thick float glass as per detailed drawing and as directed by Engineer Incharge etc. complete. Third Floor
Providing and fixing in position anodised (as per IS1868/1982) Aluminium fixed staggered (Z Type) Ventilator with Aluminium rectangular pipe 63 mm. x 38.10 milimetre x 1.33 milimetre at weight 0.650 kilogram per running metre, Aluminium angle of size 15 milimetre x 15 milimetre x 1 milimetre, aluminium channel of 9 milimetre sizes, stainless steel mosquito net of 304 Grade, 4 milimetre thick float glass as per detailed drawing and as directed by Engineer Incharge etc. complete. Fourth Floor
Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.Third Floor
Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.Fourth Floor
Providing and Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use).Third Floor
Providing and Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use).Fourth Floor
Providing and fixing 900 milimetre high S.S. 304 Grade Stainless steel railing with 40 milimetre diameter and 1.5 milimetre thick at top, 40 milimetre diameter and 1.5 milimetre thick vertical supports spaced at 1.5 m center to center and 8 milimetre thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete. Third Floor
Providing and fixing 900 milimetre high S.S. 304 Grade Stainless steel railing with 40 milimetre diameter and 1.5 milimetre thick at top, 40 milimetre diameter and 1.5 milimetre thick vertical supports spaced at 1.5 m center to center and 8 milimetre thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete. Fourth Floor
Providing and fixing 40 milimetre diameter and 1.5 milimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete. Third Floor
Providing and fixing 40 milimetre diameter and 1.5 milimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete. Fourth Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete.Fourth Floor
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge.Fourth Floor
Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 kg load bearing capacity of trolley made out of 20 mm PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 mm s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge)Fourth Floor
Providing and fixing Ivory glazed urinal of size 710x460x300 milimetre with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 milimetre diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.Third Floor
Providing and fixing Ivory glazed urinal of size 710x460x300 milimetre with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 milimetre diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.Fourth Floor
Providing and fixing Ivory Glazed Earthenware Squatting plate (Ladies Urinal) with Poly Venyl Chloride flushing cistern of 5 litre s capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 milimetre diameter Poly Venyl Chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall.Third Floor
Providing and fixing Ivory Glazed Earthenware Squatting plate (Ladies Urinal) with Poly Venyl Chloride flushing cistern of 5 litre s capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 milimetre diameter Poly Venyl Chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall.Fourth Floor
Providing and fixing ORISSA TYPE colour glazed earthen ware 625 x 450 milimetre Water Closet Pan including trap, C.I.soil and vent pipe upto the out side face of wall including 100 milimetre diameter C.I.plug, bend, 15 milimetre thick 10 litre Poly Venyl Chloride flushing cistern with all necessary pipe connection complete.Third Floor
Providing and fixing ORISSA TYPE colour glazed earthen ware 625 x 450 milimetre Water Closet Pan including trap, C.I.soil and vent pipe upto the out side face of wall including 100 milimetre diameter C.I.plug, bend, 15 milimetre thick 10 litre Poly Venyl Chloride flushing cistern with all necessary pipe connection complete.Fourth Floor
Providing and fixing half turn 25 milimetre diameter gunmetal flushing cock including all accessories complete.Third Floor
Providing and fixing half turn 25 milimetre diameter gunmetal flushing cock including all accessories complete.Fourth Floor
Providing and fixing Ivory european type wall-hung pan, of size 350 milimetre x 355 milimetre x 570 milimetre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete.Third Floor
Providing and fixing Ivory european type wall-hung pan, of size 350 milimetre x 355 milimetre x 570 milimetre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete.Fourth Floor
Providing and fixing Ivory Opal series European type wall-hung, of size 400 milimetre x370 milimetre x575 milimetre with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.Third Floor
Providing and fixing Ivory Opal series European type wall-hung, of size 400 milimetre x370 milimetre x575 milimetre with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.Fourth Floor
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.Third Floor
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.Fourth Floor
Providing and fixing wall hung Ivory wash basin of size 350x450x165 milimetre with approved make pillar cock, C.P. Angular stop cock long thread approved make continental including SS bottle trap of approved make having necessary pipe connection up to the outside face of the wall etc complete as directed by Engineer in charge.Third Floor
Providing and fixing wall hung Ivory wash basin of size 350x450x165 milimetre with approved make pillar cock, C.P. Angular stop cock long thread approved make continental including SS bottle trap of approved make having necessary pipe connection up to the outside face of the wall etc complete as directed by Engineer in charge.Fourth Floor
Providing and fixing Table top Ivory wash basin of size 120x635x405 milimetre rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge.Third Floor
Providing and fixing Table top Ivory wash basin of size 120x635x405 milimetre rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge.Fourth Floor
Providing and fixing 450 milimetre x 550 milimetre size superior type Belgium mirror with 16 milimetre diameter nickel plated towel rod complete.Third Floor
Providing and fixing 450 milimetre x 550 milimetre size superior type Belgium mirror with 16 milimetre diameter nickel plated towel rod complete.Fourth Floor
Providing and fixing 10 centimeter Poly Venyl Chloride nahani trap with grating complete.Third Floor
Providing and fixing 10 centimeter Poly Venyl Chloride nahani trap with grating complete.Fourth Floor
Providing and fixing 15 centimetre x 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 out side the building including cast iron grating in the sink, connecting glazed stonewre pipe brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge.Third Floor
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge.Fourth Floor
Providing and fixing Shower Head with shower arm of approved make shower tube hand shower with divertor of spout including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.Third Floor
Providing and fixing Shower Head with shower arm of approved make shower tube hand shower with divertor of spout including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.Fourth Floor
Providing and fixing Crome Plated Two way BIB cock of approved make including necessary sockets/ union nut etc. complete.Third Floor
Providing and fixing Crome Plated Two way BIB cock of approved make including necessary sockets/ union nut etc. complete.Fourth Floor
Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.Third Floor
Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.Fourth Floor
Providing and fixing Crome Plated pillar cock long neck with aerator of approved make including necessary sockets/union nut etc. complete.Third Floor
Providing and fixing Crome Plated pillar cock long neck with aerator of approved make including necessary sockets/union nut etc. complete.Fourth Floor
Providing and fixing Crome Plated BIB cock with wall flange of approved make including necessary sockets/union nut etc. complete.Third Floor
Providing and fixing Crome Plated BIB cock with wall flange of approved make including necessary sockets/union nut etc. complete.Fourth Floor
Providing and fixing on walls / ceiling / floor 15 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.Third Floor
Providing and fixing on walls / ceiling / floor 15 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.Fourth Floor
Providing and fixing on walls / ceiling / floor 20 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.Third Floor
Providing and fixing on walls / ceiling / floor 20 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.Fourth Floor
Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.Third Floor
Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.Fourth Floor
Providing and fixing on walls / ceiling / floor 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.Third Floor
Providing and fixing on walls / ceiling / floor 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.Fourth Floor
Providing and fixing on walls / ceiling / floor 40 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.Third Floor
Providing and fixing on walls / ceiling / floor 40 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.Fourth Floor
Providing and fixing on walls / ceiling / floor 50 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete.Fourth Floor
Providing and fixing 20 milimetre diameter screw down bib/ stop tap of brass including necessary socket union nut complete.Third Floor
Providing and fixing 20 milimetre diameter screw down bib/ stop tap of brass including necessary socket union nut complete.Fourth Floor
Providing and fixing screw down 15 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete.Third Floor
Providing and fixing screw down 15 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete.Fourth Floor
Providing and fixing screw down for 25 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete.Third Floor
Providing and fixing screw down for 25 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete.Fourth Floor
Providing and fixing screw down for 32 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete.Third Floor
Providing and fixing screw down for 32 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete.Fourth Floor
Providing and fixing screw down for 40 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete.Third Floor
Providing and fixing screw down for 40 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete.Fourth Floor
Providing and fixing screw down for 50 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete.Third Floor
Providing and fixing screw down for 50 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete.Fourth Floor
Providing and fixing on walls/ ceiling/ floors, 15 milimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 1.48 kilograme per metre with necessary fitting, remaking good the demolished portion and applying primer of anticorrosive oil paint in 2 coats complete.
Providing and laying in trenches 40 milimetre diameter medium grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 3.68 kilogram per metre with necessary fitting, remaking good the demolished portion with filling trenches and with primer of anti-corrosive primer oil paint two coats complete.
Providing and laying in trenches 50 milimetre diameter medium grade having embossed as Indian Standard Institute mark galvanised iron pipes of 5.17 kilogram per metre with necessary fitting, remaking good the demolished portion with filling trenches and with primer of anti-corrosive primer oil paint two coats complete.
Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.Third Floor
Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.Fourth Floor
Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.Third Floor
Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.Fourth Floor
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment).Third Floor
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment).Fourth Floor
Providing and laying concrete pipe of Indian Standard Non Pressure class of 100 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 150 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 225 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 300 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete cover medium duty 140 kilogram with frame etc. complete.
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete cover medium duty 140 kilogram with frame etc. complete.
Providing and fixing High Density Polymer container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity between 1000 to 20000 liters.
Providing and fixing hume pipe septic tank 900 milimetre diameter with vent pipe and cap including necessary (excluding excavation and laying)
Providing soak pit of size 120 centimetre x 120 centimetre x 120 centimetre including excavating and filling with brick-bats.
Providing and fixing machine cut both side mirror polished 18 milimetre to 20 milimetre thick telephone black granite/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone partition with rounding the edges etc. complete.Third Floor
Providing and fixing machine cut both side mirror polished 18 milimetre to 20 milimetre thick telephone black granite/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone partition with rounding the edges etc. complete.Fourth Floor
Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 16 mm thick of 1200mm (min.) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional IR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of Fourth Floor
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete.Fourth Floor
Providing fine cement finish 1.5 milimetre thick over green plaster surface including scaffolding curing etc. complete.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (For all Leads & Lifts) by Mechanical Means..
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (For all Leads & Lifts) by Mechanical Means..
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (For all Leads & Lifts) by Mechanical Means.
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 meters beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/ murum, ramming, watering including shoring and strutting, dewatering etc. complete. (For all Leads & Lifts) by Mechanical Means.
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (For all Leads & Lifts) by Mechanical Means.
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix- 10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisition enabled /concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled /concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimetre thick Cement mortar 1:3 with conceal, setcrete (RMW), Algaeproof or other alike water proofing liquids, raking of joints upto 35 milimetre depth,filling the joints with 6 milimetre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete).
Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 milimetre between rough shahabad and Reinforced Cement concrete walls with cement grout mixed with water proofing liquid Algaeproof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 milimetre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrtete 1:3:6 base concrete).
Providing earth work in embankment with approved materials obtained from other sources upto lead of 50 metre including all lifts, laying in layers of 20 centimetre to 30 centimetre thickness breaking clods, dressing to the required lines, curves, grades and section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97% of standard proctor density etc. complete (Material obtained from Other sources).
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW
Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW
Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW
Supplying and erecting mains with 4x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW
Supplying and erecting green colour earthing with 1x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW
Supplying and erecting green colour earthing with 1x 10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
Supplying and erecting mains with 4x 10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW
Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW
Supplying and erecting LED square /circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2000 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades wire mesh duly erected complete.
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting B class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 4 ways/phase (12 poles) with door 1.2mm thickness surface/flush mounted IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR
Supplying and erecting triple pole and neutral distribution board (TPNDB) 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles) with door 1.2mm thickness surface/flush mounted on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 16 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP
Providing and erecting 4 Pole MCCB 415V 400A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB
Supplying, installing, testing and commissioning of 11kV 630A 21kA/3sec 1 way indoor/outdoor extensible motorised SCADA compatible RMU internal arc tested consisting of 1 no. feeder with 1 VCB compliant to IEC 62271 -100 200 and 102 as per specification no. SW-HTS/RMU SCADA
Supplying and erecting SS enclosure for MCCB suitable for above 250 A up to 800A MCCB.
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in Marathi Hindi and English erected at position for HV/EHV (11000 Volts) installation with compliance to IS 2551-1982
Supplying and erecting self-locking arrangement with keys in duplicate made of brass of grade 1 compliance to IS 729-1979 duly erected flush with surface of panel / cupboard
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 3x240V 50 Hz with optical & RS 232 port backlit LCD measure & display trivector energy load survey TOD tamper detection & logging power ON /OFF events instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable 11 kV(E) 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying and laying (including excavation) half round reinforced cement concrete pipe of IS 458 2003 NP-2 class of 250 mm internal diameter in proper line level and slope including providing and fixing collars in cement mortar 1 2 and curing etc. complete.
Supplying and erecting rolled steel joist (girder) pole 175 x 85 mm (19.6 kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ
Supplying and erecting 100 x 50 x 6 mm with 4.7 mm thick web and 7.5 mm thick flange channel iron cross arm of suitable length for 2.4 m wide DP structure and erecting on DP with 50x6mm clamp complete as per specification no. OH-PL/BKT
Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line complete as per specification no. OH-INS/DI
Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line complete as per specification no. OH-INS/PN
Supplying and erecting distribution class 11 kV thyrite type lightening arrester with nut bolts on provided MS channel as per specification no. OH-INS/LA
Supplying and erecting G.I. stay set for poles including loop insulators at inaccessible height with anchor plate 300x300x6 mm. straining screws G.l. stay wire 7/8 SWG G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.(8-6-2)
Supplying and fixing MS base plate 30x30x0.6cm size fixed to the pole base either by welding 12mm dia fixed at position.(8-6-15)
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying, installing, testing and commissioning of 3 phase 11/0.433 kV 50 Hz. 250 kVA Mineral oil immersed and naturally cooled outdoor type Copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side temperature rise should not Exceed 45? by thermometer in oil and 50? by the resistance method in winding at full load rating using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5% having 7 number of tap positions with standard accessories complete with test certificate with losses below 980 Watts at 50% load 2930 Watts at 100% load as per IS 1180 (part 1) 2014 with necessary permissions of Electrical Inspector as per specification no SS- TR-NSL.
Spplying and erecting 11 kV outdoor type gang operated air break triple pole switch 400 A capacity with 3 post pin type insulator per phase mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of C class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp.
Supplying and erecting 11 kV outdoor type drop out fuse with insulator complete with fuse holders fuse barrel with metal fitting fuse element mounted on M.S. channel with working current of 15A capacity complete erected on provided cross arm.
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 500 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG(10-6-18)
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coats aluminium paint complete.
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class GI pipe with angle iron supports chain link wire mesh (jali) complete supported on channel iron erected in foundation and painted complete as per specification no SS-AS/DLD
Providing printed instruction chart for treating persons suffering from electric shock printed in English & Marathi and duly laminated complete.
Providing pair of duly tested rubber hand gloves as per IS 47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream medicine for use on wounds due burn crepe bandage gauge bandage medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use scissors anti-septic solution etc. (All above contents shall be of standard makes)
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables pipes & clearing the site by removing debris & making the site as required complete.
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.
Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete.
Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1 3 6 cement concrete 20 x 25 mm stone metal 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered with necessary curing and finishing complete. (for above 9 m poles)
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1 3 6 cement concrete (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).
Making cement concrete foundation in 1 3 6 cement concrete (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).
MSEDL Connection Charges
Supplying erecting testing and commissioning of diesel generating set with alternator of 200 kVA output continuous rating 3 Phase 415 V 50c/s 0.8 p. f.A.C supply a totally enclosed air cooled / liquid cooled multi-cylinder dieselengine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12hours along with standard accessories self-excited self-regulated screenprotected alternator with static excitation system running at 1500 RPM as per IS4722-2001 with voltage regulation +/- 5 % with performance class G2 andmaximum fuel consumption 34.40 Ltr/hr 75% loading. Both the engineand alternator direct coupled on a common fabricated steel base frame andmounted on anti-vibrating pads with standard control panel comprising meters switchgears indicators connected with suitable wires/cables the complete setenclosed in composite Acoustic enclosure as fully assembled integral unit made of16 SWG CRCA Sheet sound absorbing material to restrict sound level up to 75dB(A) at 1.0 m provided with first filling of oil diesel not less than 300 Ltr etc.on provided M20 Grade CC Foundation as per specification no. GEN-DG
Supplying erecting testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 180 kVA up to 200 kVA capacity Three phase 415 Volts 50Hz A.C. with all standard features safeties etc as per specification no. GEN-AMF.
Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITDspecification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying and erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying and erecting 10 pair 0.5mm dia jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying and erecting 50 pair 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier polythene sheathed G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW
Supplying, Erecting and Commissioning of MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying, Erecting and Commissioning of 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
Supplying, Erecting and Commissioning of digital (hybrid) type EPABX additional 80 extension (5*40066.95)
Supplying, Erecting and Commissioning of push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete.
Supplying, Erecting and Commissioning of IP telephone instrument as per specification complete.
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected.
Supplying, fixing, and configuring 24 ports POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 6U wall mount rack (Dimension-DxWxH 500x600x367 mm) as per specification No. WG-NAS/RAK
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No WG-MA/CON.
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.
Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying, fixing, and configuring 24 ports POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing 6U wall mount rack (Dimension-DxWxH 500x600x367 mm) as per specification No. WG-NAS/RAK
Supplying, installing, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS with backup time of 30 min PWM & IGBT based with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/17Ah -18Ah SMF battery with battery terminal wire duly charged with 12 months warranty complete
Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camerawith following features Image Sensor minimum 1/2.8 Progressive Scan CMOS Video Resolution minimum 2592 x 1520 Video Compression H.264 H.265 or higher at least Three individually configurable stream Frame rate minimum 25 fps at all resolutions WDR minimum 120 dB Wide Dynamic Range ONVIF profile conformant minimum IR distance 50m Lens Type 2.8/4/6 mm Lens fixed focal Field of View 2.8 mm horizontal FOV 107° vertical FOV 57° diagonal FOV 129°4 mm horizontal FOV 86° vertical FOV 47° diagonal FOV 102°6 mm horizontal FOV 55° vertical FOV 29° diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color minimum 0.05 Lux at Black & White 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan 350° Tilt 72° Rotate 350°. Power Supply Support 12VDC & PoE IP67 IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB Built in microphone. minimum Input/Output - Audio in × 1 Audio Out × 1 Alarm in × 1 Alarm Out × 1. Image Settings Rotate mode saturation brightness contrast sharpness gain white balance. Image Enhancements Day/Night-Auto (ICR)/Color/Black & White 3D Digital Noise Reduction Automatic White Balance Automatic Gain Control Backlight Compensation Highlight Compensation.Events Privacy Masking Motion detection Scene change detection Face capture Video tampering audio exception detection Region entrance detection Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection HTTPS IP filter IEEE 802.1X digest authentication user access log TLS1.2 AES - 256 SSH/Telnet closed FTP disabled. Protocol - DHCP UDP HTTP HTTPS NTP DNS RTP RTSP SMTP SSL/TLS TCP/IP Secure Real-Time Transport Protocol (SRTP) Bonjour SNMP and Secure shell (SSH) supported protocol. RoHS WEEE ISO-14001 and REACH ompliant UL/EN OR equivalent BIS/TECH/STQC or any indian tandards as applicable CE FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more han 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM
Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor minimum 1/2.8 Progressive Scan CMOS Video Resolution minimum 2592 x 1520 Video Compression H.264 H.265 or higher at least Three individually configurable stream Frame rate minimum 25 fps at all resolutions WDR minimum 120 dB Wide Dynamic Range ONVIF profile conformant minimum IR distance 50m Lens Type 2.8/4/6 mm Lens fixed focal Field of View 2.8 mm horizontal FOV 107° vertical FOV 57° diagonal FOV 129°4 mm horizontal FOV 86° vertical FOV 47° diagonal FOV 102°6 mm horizontal FOV 55° vertical FOV 29° diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color minimum 0.05 Lux at Black & White 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan 350° Tilt 72° Rotate 350°. Power Supply Support 12VDC & PoE IP67 IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB Built in microphone. minimum Input/Output - Audio in × 1 Audio Out × 1 Alarm in × 1 Alarm Out × 1. Image Settings Rotate mode saturation brightness contrast sharpness gain white balance. Image Enhancements Day/Night-Auto (ICR)/Color/Black & White 3D DigitalNoise Reduction Automatic White Balance Automatic Gain Control Backlight Compensation Highlight Compensation.Events Privacy Masking Motion detection Scene change detection Face capture Video tampering audio exception detection Region entrance detection Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection HTTPS IP filter IEEE 802.1X digest authentication user access log TLS1.2 AES - 256 SSH/Telnet closed FTP disabled. Protocol - DHCP UDP HTTP HTTPS NTP DNS RTP RTSP SMTP SSL/TLS TCP/IP Secure Real-Time Transport Protocol (SRTP) Bonjour SNMP and Secure shell (SSH) supported protocol. RoHS WEEE ISO-14001 and REACH compliant UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable CE FCC certified.duly erected in position on wall/ceiling/false Ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM.
Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR interface transfer rate 6 GB/S maximum sustained transfer rate 210MB/Sec to 213 MB/S. Drive bay supported 08+ Cameras supported up to 64 Cache (MB) 256 Load/Unload Cycle -3000000 Work Load Rating per Year 180TB MTBF 1000000 Hrs. HTTPS. RoHS UL CE certified duly erected in position in provided NVR as per specification no. CCTV-HDD
Spplying installing testing & commissioning of 32/40 Ch. Network Video Recorder (NVR) suitable connect Min. 32 IP Cameras up to 5 Megapixel Resolution with HDMI/VGA outputs provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher H.264 MJPEG Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks ANR Technology 4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB minimum 02 USB port Alarm I/O 16/4 RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface ONVIF conformance Multiple network monitoring Web viewer . support protocol TCP/IP DHCP DNS DDNS NTP SADP SMTP NFS iSCSI UPnP™ HTTPS. RoHS UL CE FCC certified.duly erected in provided U Rack with wiring connections tagging and programming etc. complete as per specification no. CCTV-NVR
Supplying & erecting 43 professional LED display with 1920*1080 (FullHD) Display suitable for 16/32 channel NVR and following featuresBrightness minimum 500 Cd/m2 Contrast Ratio minimum 1000 1Viewing angle 178/178 deg.Response time maximum 8 ms Inputs HDMI VGA BNC USB Audio In Built-in speakers maximum 10 W Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle dulyerected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON Response time maximum 8 msInputs HDMI VGA BNC USB Audio In Built-in speakers maximum 2 W Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON (Non CSR)
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No WG-MA/CON.
Supplying, installing, testing and commissioning of split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, installing, testing and commissioning of cassette type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room air conditioning unit 1.3TR to 1.7TR capacity having ISEER minimum 5.00 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32/R410A having copper condenser dust filter self diagnosis feature stabilizer free operation noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, installing, testing and commissioning of cassette type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room Air conditioning unit 1.8TR to 2.1TR capacity having ISEER minimum 5.00 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32/R410A having copper condenser dust filter self diagnosis feature stabilizer free operation noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete.
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.
Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC
Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire two indicator lamps dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system.
Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system.
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Harsh Constructions Pvt Ltd
OMKAR CONSTRUCTION
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid