Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC C O 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Tender accepted due to lowest and quoted reasonable rates | |
| 2 | L2₹21.0 L+₹1.8 L (9.66%)Rejected-Finance | L2 | Rejected-Finance Higher side quoted amount | |
| 3 | L3₹27.7 L+₹8.6 L (44.9%)Rejected-Finance 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Higher side quoted amount | |
| 4 | L4₹28.2 L+₹9.1 L (47.5%)Rejected-Finance BALSUA P O JHAKOLARI PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Higher side quoted amount | |
| 5 | L5₹29.0 L+₹9.9 L (51.7%)Rejected-Finance 58 1ST FLOOR PATEL NAGAR BATHINDA | BATHINDA | BATHINDA | PUNJAB | L5 | Rejected-Finance Higher side quoted amount |
| Sl No | Description | Qty | Unit | M/S RUDRA CONSTRUCTION CO L5 | M/S PREMI CONSTRUCTION CO L7 | malghotra construction co L3 | GANDOTRA CONSTRUCTION CO L4 | M/S Ajay Saini L2 | M/S Raghuvanshi Builders L8 | RAJINDER ELECTRICAL WORKS L6 | VAISHNAVI BUILDERS L1 | M/S SATYA SAI CONSTRUCTION L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out [desilting] silt, bricks bats, debris, liquid waste, sludge in solid / semisolid state from the manholes including pumping out sludge wherever necessary, slugging, diverting the flow in the drain, if necessary and staking the removed silt/sludge in deposit away from the edge of manholes as directed including use of safety belt, dry cells torch for lighting in side the man hole and taking similar safety measures and removing the sludge to a distance exceeding 250 m but not exceeding 500 m and cleaning the manholes with clean water etc complete all as specified and as directed size of manholes of depth not exceeding 1.00 meter complete all as specified and directed. | 650 | Each | 90 ₹58,500 | 110 ₹71,500 | 100 ₹65,000 | 100 ₹65,000 | 40 ₹26,000 Lowest | 80 ₹52,000 | 100 ₹65,000 | 50 ₹32,500 | 110 ₹71,500 |
| 2.00 | Taking out [desilting] silt, bricks bats, debris, liquid waste, sludge in solid / semisolid state from the manholes including pumping out sludge wherever necessary, slugging, diverting the flow in the drain, if necessary and staking the removed silt/sludge in deposit away from the edge of manholes as directed including use of safety belt, dry cells torch for lighting in side the man hole and taking similar safety measures and removing the sludge to a distance exceeding 250 m but not exceeding 500 m and cleaning the manholes with clean water etc complete all as specified and as directed for manholes of following size of manholes of depth exceeding 1.50 meter but not exceeding 2.00 meter complete all as specified and directed. | 240 | Each | 120 ₹28,800 | 110 ₹26,400 | 100 ₹24,000 | 100 ₹24,000 | 40 ₹9,600 Lowest | 80 ₹19,200 | 150 ₹36,000 | 78 ₹18,720 | 110 ₹26,400 |
| 3.00 | Taking out [desilting] silt, bricks bats, debris, liquid waste, sludge in solid / semisolid state from the manholes including pumping out sludge wherever necessary, slugging, diverting the flow in the drain, if necessary and staking the removed silt/sludge in deposit away from the edge of manholes as directed including use of safety belt, dry cells torch for lighting in side the man hole and taking similar safety measures and removing the sludge to a distance exceeding 250 m but not exceeding 500 m and cleaning the manholes with clean water etc complete all as specified and as directed for manholes of following size of manholes of depth exceeding 2.00 meter but not exceeding 4.50 meter complete all as specified and directed. | 200 | Each | 175 ₹35,000 | 150 ₹30,000 | 220 ₹44,000 | 100 ₹20,000 | 40 ₹8,000 Lowest | 220 ₹44,000 | 165 ₹33,000 | 200 ₹40,000 | 150 ₹30,000 |
| 4.00 | M&L for Bailing out water from existing septic tank and filter bed including inspection chamber and getting out sludge and other accumulated materials complete by mannually or using the machinery for work in foul position or in liquid mud all as directed by Engineer -In - Charge complete all as specified and directed. | 300 | Cum | 500 ₹1,50,000 | 500 ₹1,50,000 | 344 ₹1,03,200 | 100 ₹30,000 | 65 ₹19,500 Lowest | 450 ₹1,35,000 | 400 ₹1,20,000 | 250 ₹75,000 | 500 ₹1,50,000 |
| 5.00 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. | 690 | Cum | 120 ₹82,800 | 150 ₹1,03,500 | 130 ₹89,700 | 120 ₹82,800 | 85 ₹58,650 | 110 ₹75,900 | 145 ₹1,00,050 | 75 ₹51,750 Lowest | 150 ₹1,03,500 |
| 6.00 | Excavating in trenches, n exc 1.5m wide and exc 1.5m but n exc 3 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 3m in depth and getting out in soft/loose soil complete all as specified and directed. | 84 | Cum | 150 ₹12,600 | 150 ₹12,600 | 198 ₹16,632 | 120 ₹10,080 | 85 ₹7,140 Lowest | 110 ₹9,240 | 175 ₹14,700 | 125 ₹10,500 | 150 ₹12,600 |
| 7.00 | Demolition and breaking up drain pipes of internal dia 150/200 mm in cement mortar including bedding and hunching complete all as specified and directed. | 920 | RM | 50 ₹46,000 | 75 ₹69,000 | 30 ₹27,600 | 10 ₹9,200 Lowest | 85 ₹78,200 | 42 ₹38,640 | 35 ₹32,200 | 10 ₹9,200 Lowest | 75 ₹69,000 |
| 8.00 | M&L for HDPE DWC (Double wall corrugated) Pipes confirming to IS-16098, of 150mm internal dia, pressure rating SN-8 fixede with rubber seal and coupler required with and including suitable bends 90/60/45 degree etc, single Y junction, complete as required, fixed as per manufacturer instructions laid in trenchs for sewage lines including testing complete all as specified and as directed. | 500 | RM | 750 ₹3,75,000 | 825 ₹4,12,500 | 520 ₹2,60,000 | 700 ₹3,50,000 | 410 ₹2,05,000 Lowest | 900 ₹4,50,000 | 750 ₹3,75,000 | 450 ₹2,25,000 | 825 ₹4,12,500 |
| 9.00 | M&L for HDPE DWC (Double wall corrugated) Pipes confirming to IS-16098, of 200mm internal dia, pressure rating SN-8 fixede with rubber seal and coupler required with and including suitable bends 90/60/45 degree etc, single Y junction, complete as required, fixed as per manufacturer instructions laid in trenchs for sewage lines including testing complete all as specified and as directed. | 420 | RM | 850 ₹3,57,000 | 910 ₹3,82,200 | 720 ₹3,02,400 | 800 ₹3,36,000 | 410 ₹1,72,200 Lowest | 1,050 ₹4,41,000 | 850 ₹3,57,000 | 650 ₹2,73,000 | 910 ₹3,82,200 |
| 10.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. as in soils complete all as specified and directed. | 711.5 | Cum | 155 ₹1,10,282.5 | 75 ₹53,362.5 | 30 ₹21,345 | 100 ₹71,150 | 50 ₹35,575 | 30 ₹21,345 | 55 ₹39,132.5 | 20 ₹14,230 Lowest | 75 ₹53,362.5 |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
8 Jul 2025, 6:00 pmClosed
GE(WEST)PATHANKOT
GE(WEST)PATHANKOT
REPAIR, CLEANING AND DESLUDGING OF SEWAGE LINES, MANHOLES AND SANITARY FITTINGS, MH COVER ETC. IN MD ACCN IN AOR OF AGE BR-II UNDER GE(WEST)PATHANKOT
2025_MES_713465_1
GE/PKT-23/2025-26
Open Tender
Miscellaneous Works
Item Rate
330 days
GE(WEST)PATHANKOT
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE(WEST)PATHANKOT
₹62,000
12 Sept 2025
10 Jun 2025
10 Jul 2025
10 Jun 2025
8 Jul 2025
24 Jun 2025
Amount
Taking out [desilting] silt, bricks bats, debris, liquid waste, sludge in solid / semisolid state from the manholes including pumping out sludge wherever necessary, slugging, diverting the flow in the drain, if necessary and staking the removed silt/sludge in deposit away from the edge of manholes as directed including use of safety belt, dry cells torch for lighting in side the man hole and taking similar safety measures and removing the sludge to a distance exceeding 250 m but not exceeding 500 m and cleaning the manholes with clean water etc complete all as specified and as directed size of manholes of depth not exceeding 1.00 meter complete all as specified and directed.
Taking out [desilting] silt, bricks bats, debris, liquid waste, sludge in solid / semisolid state from the manholes including pumping out sludge wherever necessary, slugging, diverting the flow in the drain, if necessary and staking the removed silt/sludge in deposit away from the edge of manholes as directed including use of safety belt, dry cells torch for lighting in side the man hole and taking similar safety measures and removing the sludge to a distance exceeding 250 m but not exceeding 500 m and cleaning the manholes with clean water etc complete all as specified and as directed for manholes of following size of manholes of depth exceeding 1.50 meter but not exceeding 2.00 meter complete all as specified and directed.
Taking out [desilting] silt, bricks bats, debris, liquid waste, sludge in solid / semisolid state from the manholes including pumping out sludge wherever necessary, slugging, diverting the flow in the drain, if necessary and staking the removed silt/sludge in deposit away from the edge of manholes as directed including use of safety belt, dry cells torch for lighting in side the man hole and taking similar safety measures and removing the sludge to a distance exceeding 250 m but not exceeding 500 m and cleaning the manholes with clean water etc complete all as specified and as directed for manholes of following size of manholes of depth exceeding 2.00 meter but not exceeding 4.50 meter complete all as specified and directed.
M&L for Bailing out water from existing septic tank and filter bed including inspection chamber and getting out sludge and other accumulated materials complete by mannually or using the machinery for work in foul position or in liquid mud all as directed by Engineer -In - Charge complete all as specified and directed.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, n exc 1.5m wide and exc 1.5m but n exc 3 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 3m in depth and getting out in soft/loose soil complete all as specified and directed.
Demolition and breaking up drain pipes of internal dia 150/200 mm in cement mortar including bedding and hunching complete all as specified and directed.
M&L for HDPE DWC (Double wall corrugated) Pipes confirming to IS-16098, of 150mm internal dia, pressure rating SN-8 fixede with rubber seal and coupler required with and including suitable bends 90/60/45 degree etc, single Y junction, complete as required, fixed as per manufacturer instructions laid in trenchs for sewage lines including testing complete all as specified and as directed.
M&L for HDPE DWC (Double wall corrugated) Pipes confirming to IS-16098, of 200mm internal dia, pressure rating SN-8 fixede with rubber seal and coupler required with and including suitable bends 90/60/45 degree etc, single Y junction, complete as required, fixed as per manufacturer instructions laid in trenchs for sewage lines including testing complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. as in soils complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
Demolition of brick work, stone/boulder masonry built in cement mortor incl all quions, arches, pillars etc. complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed.
M&L for Cement concrete Type D-2 1:4:8 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass-concrete complete all as specified and directed.
Demolition of cement concrete (unreinforced) in any description or in any position not otherwise provided for complete all as specified and directed.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for RCC structures including cutting of reinforcement as required to facilliate demolition complete all as specified and directed.
M&L for providing Precast Cement Concrete Type B-1 1:2:4 (using 20mm graded crushed stone aggregate) in landings, cover slabs (for manholes etc.) , water troughs and similar articles with plain faces and setting in cement mortar 1:6 complete with joints to match complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
All as per srl item no 18.00 here-in-before but 6 to 8 mm dia
Taking down of cement plaster any description including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 250 m complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and directed.
M&L for 75 mm thick PCC as in plinth protection / apron type C-2, 1:3:6 (using 40 mm graded crushed stone aggregate) finishing cement surfaces even and smooth without using extra cement and spike rolling complete all as specified & directed.
M&L for 100 mm thick PCC 1:2:4 type D-2 (using 40 mm graded crushed stone aggregate) as in floor and finishing even and smooth with using extra cement complete all as specfied and directed.
M&L for non abrasive paving (endura) tiles 300mm x 300mm x10mm thick (square/ rectangular) polished, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over & including 15mm screed bed CM 1:4 to match complete all as specified and directed.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including dismantling old tiles and in this item for necessary raking circular cutting or notching and waste on tiles complete all as specified and directed.
Surface excavation not exc 30 cm depth and averaging 15cm deep in foul condition for removing heaps of waste, cleaning of flora, fauma, foliage and bushes around septic tanks,manholes and soak pits removing debris/ heaps of bushes etc from vicinity and depositing at a place where complete all as specified and as directed
M&L for 75mm thick PCC 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base Finishing surfaces of concrete to be even and rough complete all as specified and as directed.
M&L for Coloured machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 60 mm thickness, M-40 grade rubber moulded glossy finish with grey cement and pigment complete all as secified and as directed. Note-Shapes of interlocking paver block shall be triangular/Zigzag/Haxagon/or other ,Colour of paver blocks (50% yellow and 50% Red) & laying pattern approved by GE.
M&L for sand filling under floors or in foundations including watering and consolidation or layer of sand cushioning below interlocking paver block complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, PVC/AC or Reinforced concrete) set in cement mortar,and taking out of trenches, if required, Internal dia of pipe in 75mm/100mm complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
Taking down eaves gutter and rain water pipe any size any pattern , PVC/ AC pipe including all fittings ,heads shoes, bends etc including removal to store ,Internal dia of pipe in 75mm/110mm complete complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) bends radius 75mm dia complete all as specified and directed.
S&F PVC (SWR) bends radius 110mm dia complete all as specified and directed.
S&F in repairs 75mm PVC floor trap, with CP grating with/without waste pipe hole incl jointing to waste pipe fixed with solvent cement complete all as specified and as directed.
S&F PVC (SWR) Single 'T ' radius 110mm dia complete all as specified and directed.
S&F PVC (SWR) Single 'T' radius 75mm dia complete all as specified and directed.
S&F in repair Vitreous China wash down water closet pan including P or S trap of bore 125/110 mm (pedestal pattern), white or in matching colour of tiles (excluding flushing cistern and flush pipe) including plastic water closet seat, white or in matching colour , closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and wash down water closet complete all as specified and as directed.
S&F in repair Plastic seat cover (White) for EWC with mild steel chromium plated or aluminium hinges complete all as specified and directed.
S&F in repair vitreous china wash down water closet (Orissa pattern white of size 580 mm x 440mm with integral foot rest, CI "P" or "S" trap with all fittings complete including connection to trap and to flushing pipe anti syphonage pipe including making good to floor,cleaning surface etc complete all as specified and as directed.
Cleaning of sewage line in any depth , including cleaning of connected sewage pipe line from manhole of size 100/150/160/200/ 300mm bore laid in trenches and any length,including water closet, gully trap etc by hydraulic jet pressure machine as required at site flushing the line and manholes with water as to make the fully functional line with man hole to entire satisfaction of Engr-in-charge and removing sludge out side the periphery of defence land at his own arrangement where sanitary hazards do not take place as per direction/instruction of civil authority and burried in excavated pits and covering the same. Adequate water for flush out sludge to be arranged by the contractor without any extra cost.Pipe line including manholes cleared/ cleaned under this item is to arranged by the contractor without any extra cost.pipe line including manholes cleared/cleaned under this item is to be maintained by the contractor and kept fully functional by removing any type of blokage of entire period of completion of work without any extra cost and refixing manhole cover after cleaning all as specified and directed. Note: unit rate quoted by tenderer shall include taking out sludge from line to manhole(liquid,semi-liquid,solid) excavation of borrow pit for dumping sludge, removing including loading, unloading and transportation etc Note:- Manhole cleaning in any depth area desluding, dewatering of man hole and etc is taken in item no 1, 2 and 3.
To attend and rectify of sewage system complaint in daily routine basis as per complaint lodged by user at complaint cell of AGE B/R-II Sub division by deploying manpower by cleaning/clearing/removal blockage such as blockage/ chocked in any type/size/height/depth/location of WCs/urinal/bathroom /kitchen /WHB upto 1st manhole of sewage line along with any type/size/height/depth bore of outlet SGSW/PVC/CI/ UPVC/RCC etc pipe & including all kind of traps such as inspection chamber/Floor/ Nahani /Gully /Intercepting /bottle trap/P or S/multi floor traps of any type SGSW/PVC/CI/UPVC etc and in any position below or above ground level, in any floor, located in different situations, including opening/clearing eyes of sewage waste pipes/vent pipe etc, opening the access cover/grating and taking out/removing all material such as sludge/ soil waste/sludge water/polythene /mud/silt/liquid/semi liquid / semi solid/solid /bricks bats/debris/soil etc any unwanted materials of any kind etc including flushing with adequate water after cleaning make the all system fully functional to the entire satisfaction of Engr-in-Charge, re-fixing the existing opened access cover and removing all retrieved material/unwanted/foreign material in any liquid/solid state etc outside the periphery of defence land at his own arrangement where sanitary hazards do not take place as per directions/ instructions of civil authority and buried in excavated pits in suitable size and depth and covering the same minimum 25cm thick compacted layer of soil with the soil obtained from excavation of pit including all excavations and earth work including applying bleaching powder to maintain hygiene. Adequate water for flush out be arranged by the contractor without any extra cost complete all as specified and directed.
Notes :-For serial item no 1, 2, 3, 43 & 44 contractor will deploy sufficient manpower daily to attend day to day complaint as mentioned above in the concerned items. Mazdoor will report daily at compliant cell of AGE B/R - II Sub division at 8.30 AM to collect complaints and depart 5pm after attending all complaints. In case of none attending complaints in same day, recovery @ RS 250 per complaints will be recovered from contractor. (ii) Contractor accredited representative shall be available during cleaning. (iii) Unit rate quoted by tenderer shall included for all precautions to be taken by workers while working in foul condition, Contractor shall take all necessary actions. (iv) Unit rate quoted by tenderer shall include excavation of borrow pits for dumping, removing including loading/ unloading and transportation in covered container etc (v) Unit rate quoted by tenderer shall included for Washing, cleaning floors with adequate water of any type of drops and splashes and leaving premise clean and tidy. (vi) Unit rate quoted by tenderer shall included for use of all scaffolding, trestles, ladders, cradles etc ,hoisting, lowering and protective measures etc up to four storeys height of bldgs. (vii) Contractor will ensure to remove the foul material in packed containers.
Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 65,890.00 and any other reduction if any from quoted amount.
M/S Ajay Saini (BID ID -3351824)
malghotra construction co (BID ID -3351353)
GANDOTRA CONSTRUCTION CO (BID ID -3351746)
M/S RUDRA CONSTRUCTION CO (BID ID -3346798)
RAJINDER ELECTRICAL WORKS (BID ID -3349095)
M/S PREMI CONSTRUCTION CO (BID ID -3350894)
M/S SATYA SAI CONSTRUCTION (BID ID -3351011)
M/S Raghuvanshi Builders (BID ID -3351245)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .