Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC 447 A DHALITITHA BASIRHAT NORTH 24 PARGANAS PIN 743412 WEST BENGAL | BASIRHAT | NORTH 24 PARGANAS | WEST BENGAL | 743412 | ₹2.9 L | L1 | Accepted-AOC L1 as accepted |
| 2 | L2₹3.3 LRejected-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | ₹3.3 L | L2 | Rejected-Finance Rejected as L2 |
| 3 | L3₹3.3 LRejected-Finance | ₹3.3 L | L3 | Rejected-Finance Rejected as L3 |
| 4 | L4₹3.3 LRejected-Finance MOULVIPARA SUTI MURSHIDABAD 742201 | SUTI | MURSHIDABAD | WEST BENGAL | 742201 | ₹3.3 L | L4 | Rejected-Finance Rejected as L4 |
Tender Value
₹3.6 L
EMD Value
₹7,179
Closing Date
28 Jan 2026, 12:00 pmClosed
AE,SKHESD I
O/o The Assistant Engineer South Kolkata Health Electrical Sub Division-I, P.W.Dte. K.S.Ray T.B. Hospital, Jadavpur, Kolkata - 700 032
Electrical Installation work for SITC of 02 nos. 20 passenger bed-cum-passenger lift at Baghajatin S.G. Hospital
2026_WBPWD_986693_1
WBPWD/AE/SKHESD-I/NIT-19/25-26
Open Tender
ELECTRICAL WORKS ORG
180 days
Baghajatin S.G Hospital
Please refer Tender documents.
5 documents required · 5 mandatory
₹7,179
13 May 2026
9 Jan 2026
30 Jan 2026
9 Jan 2026
28 Jan 2026
15 Jan 2026
Supplying and fixing 415 V, 100 A TPN SFU open execution in existing SS enclosure/ cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. ( Make:- L&K / Siemens / ABB as approved by E.I.C)
Supplying and fixing of 100A, 4 way double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Incoming-01 no.- 63A 4P MCCB Outgoing- 02 nos.-40A TP MCB 06 nos- 6-32A SPMCB (Make:-Legrand/seimens/L&K as approved by E.I.C)
Supplying and fixing 4way double door sheet steel (16SWG), powder coated cable end box for TPN DB vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment.
Supplying and fixing double-door (2+8) way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Incoming -1 no. DP MCB Isolator- 40A, Outgoing - 8 nos 6-32A SP MCB. (Make: Legrand/seimens/L&K as approved by E.I.C)
Supplying and fixing 6-32A DP MCB with SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. (Make: Legrand/seimens/L&K as approved by E.I.C)
Supplying and fixing 63A FP MCB with SS enclosure with IP-20/30 protection, powder coated provision for four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. (Make: Legrand/seimens/L&K as approved by E.I.C)
Supply of 4 Core 35 Sqmm XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes. [Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C]
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting.
Laying of 35 Sqmm cable as below, on existing Cable Tray and binding with suitable size GI wire.
Distribution wiring in 1.1 KV single core stranded 'FRLSH' PVC insulated & unsheathed copper wire (Make: KEI/Havells/ Polycab/Gloster) in 20mm/suitable size PVC rigid conduit 'FR' ( Make: Precision/Polycab, MMS / HMS type) incl. necy. fittings as required.
2 x 22/0.3 (1.5 sq. mm) + 1 x 22/0.3 (1.5 sq. mm) ECC
2 x 36/0.3 (2.5 sq. mm) + 1 x 22/0.3 (1.5 sq. mm) ECC
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLSH' PVC insulated & unsheathed copper wire (Make: KEI / Havells/ Polycab/Gloster) in 20mm size PVC rigid conduit 'FR' (Precision/Polycab, MMS /HMS type) , with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx 100mm x65mm inspection box, mak ing earthing attachment, painting the MS box and mending good the damages to original finish. Avg run 6 mtr.
Distribution wiring in 1.1 KV grade 3 x 22/0.3 (1.5 sq. mm) single core stranded 'FRLSH' PVC insulated & unsheathed copper wire (Finolex/Havells /Polycab /Gloster) in 20 mm size MMS PVC rigid conduit 'FR' (Precision MMS / Polycab MMS make) to 6 A, 5 pin flush type plug socket & Piano Key type switch (Anchor) fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite (wall matching colour) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish - On Board.
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Make: anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 20 A, plug socket with separate 20 A Piano key type switch (Anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3 mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & fixing of LED Bulk head fitting (Make - Philips WT140W LED7S CW PSU S1 PC /Wipro, Cat No. LW07-141-XXX-57-G1) on wall / ceiling by screws etc.
Supply & Delivery of 240V, 18/ 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Supply and Delivery of 4 feet Industrial box type Single LED tube batten/ mounting rail (rust free) suitable for double TLED lamp. [Make- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate]
Supply & Delivery of 220V, Single Phase, 50 Hz A.C heavy duty exhaust fan of following sizes having complete metal body of 300 mm (12"), 4 Blade, RPM ≤ 1420 , Wattage ≤ 90 Watt, Sound level ≤ 56 dB, Air Displacement (In CMH) ≥ 1120 (Make- EPC/ USHA/Orient CROMTON) [ISI mark, IP55 rated]
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing 30 cm (12") exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of 4 core 35 Sqmm Al. Armoured XLPE/PVC armoured cables.
Finishing the end of 4 core 35 Sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2 x 2.5 sq. mm + 1 x 1.5 sq. mm
4 x 10 sq. mm + 2 X 6 sq. mm
Excavation of soil for installation of Earth Electrode and filling & ramming. For soft soil.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By TATA-Medium GI pipe.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
Extra for treatment of soil by using salt & charcoal or coke for plate electrode.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Supply and Fixing of poceline post insulator(SP65 of ASIAN Electrical and Electronics) suitable for passing for earth conductor (as approved by EIC) with two nos of screw on wall and suitable arrange ment for fixing of earth continuty flat.
Supply & fixing of interval timer to the exhaust fan incomig supply for smooth running. [ON-15 min & OFF-10Min]
Charges for dismantling of existing panel, cables of the existing damaged old G.I structuture by sufficient man power & tools tackles.(One semi-skilled and 2 unskilled for 2 days)
Less cost of dismantle and unserviceable materials Rs. 2,000/-
[Make and model no. of each and every item to be approved by EIC] Rate must be incl of all taxes
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_2408894.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid