Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | ₹24.7 L Quoted ₹25.4 L | L1 | Accepted-AOC The lowest e-tenderer |
| 2 | L2₹28.6 L+₹3.2 L (12.5%)Rejected-Finance | ₹28.6 L+₹3.2 L (12.5%) | L2 | Rejected-Finance Not Meeting eligibility criteria |
| 3 | L3₹28.6 L+₹3.2 L (12.5%)Rejected-Finance B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | ₹28.6 L+₹3.2 L (12.5%) | L3 | Rejected-Finance Not Meeting eligibility criteria |
| 4 | L4₹40.2 L+₹14.8 L (58.2%)Rejected-Finance ROOM NO D 297 PART III GANESH MURTI NAGAR CUFF PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | ₹40.2 L+₹14.8 L (58.2%) | L4 | Rejected-Finance Not Meeting eligibility criteria |
| 5 | L5₹41.5 L+₹16.1 L (63.4%)Rejected-Finance | ₹41.5 L+₹16.1 L (63.4%) | L5 | Rejected-Finance Not Meeting eligibility criteria |
Tender Value
₹44.1 L
EMD Value
₹88,200
Closing Date
10 Jan 2024, 6:00 pmClosed
Shri T Rajasekharam, IDSE, SE (SAG)
Headquarters Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
REPAIR AND REPLACEMENT OF FIRE ALARM SYSTEM FIRE HOSE REEL DRUM HYDRANT AND CONNECTED ITEMS AND PERIODICAL TESTING OF FIRE FIGHTING SYSTEM AT COLABA MIL STN UNDER GE WEST MUMBAI
2023_MES_632728_1
85100/W/E8
Open Tender
Civil Works
Item Rate
330 days
Garriosn Engineer (West) Colaba
Please ref tender documents
7 documents required · 7 mandatory
₹500
Garrison Engineer (W) Colaba
₹88,200
23 Feb 2024
14 Dec 2023
11 Jan 2024
14 Dec 2023
10 Jan 2024
28 Dec 2023
14 Dec 2023 - 3 Jan 2024
Amount
Part-I (Comprehensive Maintenance) Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking /cleaning/ make servicable of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at TILOTAMA Building (G+12) comprising following:- (a) Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections (d) Lead acid battery 12V/9AH Capacity. (e) all size pump/ jackey pump etc 100HP Main Fire Hydrant Pump Servicing & Testing (f) Testing of Electrical control panel of Fire Fighting System Water Pumps. (g) Testing of Pressure switch & Pressure Guage. (h) Testing of all Sluice Valve, NRV & Air Release Valve. P.M. (j) Cleaning of fire pump house, motor pump, LT panel water pipe line, valvem smoke detector, manual call point, hooter etc
All as per ser item no 1 but Fire Fighting System, Fire Alarm System installed at MENKA Building (G+13)
All as per ser item no 1 but Fire Fighting System, Fire Alarm System installed at CHITRALEKHA Building (G+13)
All as per ser item no 1 but Fire Fighting System, Fire Alarm System installed at S & T COMPLEX Building (G+8)
All as per ser item no 1 but Fire Fighting System, Fire Alarm System installed at Agastya Building (G+12)
All as per ser item no 1 but Fire Fighting System, Fire Alarm System installed at Suvarna Building (G+6)
All as per ser item no 1 but Fire Fighting System, Fire Alarm System installed at Brahmaputra Building (G+14)
All as per ser item no 1 but Fire Fighting System, Fire Alarm System installed at P-106 Building (G+12)
All as per ser item no 1 but Fire Fighting System, Fire Alarm System installed at P-120 Building (G+14)
All as per ser item no 1 but Fire Fighting System, Fire Alarm System installed at P-121 Building (G+12)
All as per ser item no 1 but Fire Fighting System, Fire Alarm System installed at P-112 Building (G+12)
All as per ser item no 1 but Fire Fighting System, Fire Alarm System installed at P-107 Building (G+14)
All as per ser item no 1 but Fire Fighting System, Fire Alarm System installed at P-105 Building (G+12)
Part-II (Material) Supply and fixing in repair transformer AC/DC for fire alarm system panel of electronic type
Supply and fixing in repair battery duly charged 12 V, 7.2 AH. Make: EXIDE/Amron/Panasonic
Supply and fixing in repair Zone cards Make : Ravel/Honeywell/Appolo/Morley
Supply and fixing in repair power cards Make : Ravel/Honeywell/Appolo/Morley
Replacement of manual call point suitable for addressable system duly painted in red colour paint with front glass (to be broken in case of fire ) complete with test key to check the response with out breaking the glass and die cast aluminum housing with IFD indicator all as specified. Make : Ravel/Honeywell/Appolo/Morley
Supply , Commissioning and Testing of addressable type manual call points & Electronic dual tone hooter operating with PA system of every floor complete all as specified and directed. Make : Ravel/Honeywell/Appolo/Morley
Supply and fixing in repair detectors complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination Photoelectric /Optical with base with self built intelligence as per IS: 11360. Make : Ravel/Honeywell/Appolo/Morley
Supply and fixing in repair hydrant valve wheel complete.
Supply and fixing in repair hydrant SS female coupling 63 mm dia
Supply and fixing in repair rubber hose drum adopter connection (shank reducer).
Supply and fixing in repair brass lock pin (lugs) for 63 mm dia.
Supply and fixing in repair brass hydrant valve spindle.
Supply and fixing in repair rubber hose pipe 20mm dia, plain 2 ply rayon braided high pressure. Make : DEEP JYOTI / DUNLOP
Supply and fixing in hose reel drums suitable for rubber hose pipe 20mm dia.
Supply and fixing in repair SS nozzle suitable for 20 mm dia rubber hose pipe.
Supply and fixing in repair 100 mm sluice valve wheel.
Supply and fixing in repair brass hydrant valve nut as per existing size.
Supply and fixing blank flange of size 100mm made out of MS 12 mm thick including flange joint.
Supply and fixing PVC blank cap of hydrants with GI chain.
Supply & Fix Factory fabricated MS fire cabinet box as per give design made out flat CRCA of appropriate size and thickness all as directed including two coat of powder coated approved colour synthetic enamel paint over a coat of red oxide primer & fixed on wall with necessary nuts/bolts or welding to existing MS pipe by supporting angle complete all as specified & directed by Engineer-in-Charge.
Supply and fix MS plate in short pieces of appropriate size & thickness required as per site requirement to existing fire cabinet box by means of welding including two coat of synthetic enamel paint (approved colour) over a coat or red oxide primer complete all as specified & directed by Engineer-in-Charge.
Supply and fixing in repair canvas fire hose 63mm dia bore 15 metre long confirming to IS Having male/female SS coupling both end complete all as specified.
Supply and fixing in repair SS Nozzle 25 mm bore suitable for 63mm dia canvas pipe complete all as specified.
Excavation in trenches n.ex.c 1.5 meter wide and n.exc 1.5 meter in depth for laying of pipe/cable etc and getting out in soft / loose soil.
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Returning, filling is including spreading, leveling, watering and well ramming in layers n.exc. 25cms(Soil).
Cutting out concrete blocks, slabs, brickwork or stone masonry(in alternate course) forming toothings for and bonding new work in mortar into old work, including new materials entering old wall.
Supply and fix fire brigade inlet connection (suction collecting head) made out of 150 mm MS pipe, consisting of four nos 63mm dia brass instantaneous type male coupling with built in check valves complete with all accessories.
Supply & Fix fire hydrant stand post including single outlet fire hydrant of 63 mm dia complete all as specified and directed by Engineer-in-Charge.
Taking down existing single acting valve of size 100 x 65mm for servicing including replacement of unserviceable spares ie gland, nut, bolt, lock pin, CI hand wheel with chain, etc complete and re-fixing in position in high rise bldg not exceeding 15 stories.
Supply and fix Automatic air release valve 100 mm dia suitable for domestic water including all connecting materials complete all as specified and directed
Supply & Fix 20 mm dia Gun Metal globe valve crutch or butterfly handle screwed both ends all as specified and directed
Supply, Installation, Testing & Commissioning of Double door Hose box with painting with necessary fittings as per specification. Details: Fire Hose Cabinets shall be fabricated from 18 gauge MS Sheet with locking arrangement of size of hose cabinet shall be 800 X 600 X 250mm, with 4mm thick glass door, the painting of the hose cabinet shall be as described earlier. Each hose cabinet shall accommodet Hydrant valve. Two nos of 15 Mtr. long hosepipes & One no. of branch pipe with nozzle. The Fire Hose cabinet will have the legend "FIRE HOSE" painted prominently in the graphic style including taking down existing box all as specified and as directed . Make- EXFLAME/CEASE FIRE/VIJAY ENGG/WINCO
Taking down existing double acting valve of size 100 x 65mm for servicing including replacement of unserviceable spares ie gland, nut, bolt, lock pin, CI hand wheel with chain, etc complete and re-fixing in position in high rise bldg not exceeding 15 stories.
Taking down existing double acting valve of size 100 x 65mm for servicing including replacement of unserviceable spares ie gland, nut, bolt, lock pin, CI hand wheel with chain, etc complete and re-fixing in position in high rise bldg not exceeding 15 stories.
Supply & Fix SS double acting fire hydrant valve of size 100 x 65mm conforming to IS – 5290/71 with all fitments such as cap cover instantaneous coupler for making flanged joint 100mm dia bore.
Repairing to MS front door of size not exceeding 1.5 mtr x 1.5mtr including welding locking arrangement including providing pad lock 50mm all as specified and as directed. Make : GODREJ/NAVTAL
Preparing old painted surface of CI/MS pipe 80/100/150mm dia and applying two coats of synthetic enamel paint (Red colour) including a coat or red oxide primer”
Preparing old painted surface of pump, motor, LT panel and applyaing two coats of synthetic enamel paint (Red colour) including a coat or red oxide primer”
Servicing of hose reel drums by applying greasing, oiling etc and making free rotation to hose drum all as specified and directed all as specified.
Removing old paint by paint removers and cleaning with scrappers, any number of coats, steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer on fire fighting cubical box fitted inside bldg on each floor.
Supply and replacement, installation, testing & commissioning of Micro processor based 2 wire fault tolerant loop, required loop networkable type 5 Loop (each loop accessing maximum 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output. The Panel shall support 24 zones Addressable 2 way Talk Back fire fighter communication, in case of emergency. The panel shall have ability to get integrated with PA System for zone wise annoucements. The panel shall support both Loop Powered & conventional Notification devices for emergency responses. the Panel shall support Auto learn feature. The panel should support networking upto 99 panels with maximum distance of 12 Km between 1 & last & 1.5 KM between adjacent panels on RS485. Tha Panel shall support IP connectivity if requred to connect on LAN or WAN network. the panel shall support BMS connectivity through Bacnet/Modbus moduels. The Panel Shallbe Sheet Steel Painted, selaed to IP30. The Panel Shall have 24 Zones with Individual LEd Indicators, expandable to 80 LED Indicators. The Panel Shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required.and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54/ LPCB/ VDS/ UL/BSA complete all as specified and directed by Engineer-in-Charge, Voice Alarm controller with USB, MP3, AM/FM player )with 1000 watts Power Amplifier. Make :- Ravel/Honeywell/Appolo/Morley
Supply & Fix in repairs MS pipes 100mm dia conforming to IS 1239 (Part-I) medium grade with both ends flanged and drilled with standard MS fitting including 02 coats of synthetic enamel painting over one coat of red oxide primer in any length and fixed on walls, complete all as specified and directed in high rise buildings Note : MS flanges including welding to MS pipes and all flanged joints shall be measured and paid separately under respective item of Sch ‘A’
Supply & Fix in repairs MS pipes 150mm dia conforming to IS 1239 (Part-I) medium grade with both ends flanged and drilled with standard MS fitting including 02 coats of synthetic enamel painting over one coat of red oxide primer in any length and fixed on walls, complete all as specified and directed in high rise buildings Note : MS flanges including welding to MS pipes and all flanged joints shall be measured and paid separately under respective item of Sch ‘A’
Material and labour for MS flanges duly drilled including welding to MS pipes, nuts, bolts, washer etc complete all as specified.
Supply and fix in repair SS fire hydrant single acting of size 80x63mm for stand post.
Supply & Fix in repairs sluice valve, 100mm size, both ends flayed with high tensile brass spindle,cast iron body, as per IS-14826 & ISI Marked,PN-1.6 pressure rating including all joints with rubber or fibre board, nuts, bolts, washers etc complete all as specified.
Supply & Fix in repairs sluice valve, 150mm size, both ends flayed with high tensile brass spindle,cast iron body, as per IS-14826 & ISI Marked,PN-1.6 pressure rating including all joints with rubber or fibre board, nuts, bolts, washers etc complete all as specified.
Supply & Fix in repairs Butterfly Valve, 80 mm size, both ends flayed with high tensile brass spindle,cast iron body, as per IS-14826 & ISI Marked, including all joints with rubber or fibre board, nuts, bolts, washers etc complete all as specified.
Supply & Fix in repairs Butterfly Valve, 100mm size, both ends flayed with high tensile brass spindle,cast iron body, as per IS-14826 & ISI Marked, including all joints with rubber or fibre board, nuts, bolts, washers etc complete all as specified.
Supply & Fix in repairs mild steel, conforming to Fe-410-0 or Fe-310-0, as in framed brackets of angles, cut to shape, drilled and counter sunk for screw including bending and welding as necessary guest plate, riveting complete.
S&F Non return valve, ball type, conforming to IS, Model B-05, of size 100mm.
Supply and fix in repairs FOOT valve, 150 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc. complete all as specified
Supply, fixing and testing of 1.5 Sqmm x 6 Core Copper Armored Cable duly shaddled in walls, cable glands complete all as directed.
M & L for Active SS 304 Digital Water Level Indicators complete accessories suitable for showing water level in operator room from under ground sump of capacity 2LG to 0.5 G including suitable size electrical fittings, suitable size cable sump to pump house, fixing arrangement etc size, Model Name/Number: Dwli complete all as specified and directed by Engineer in charge.
Supply and Fix Pressure gauge 100mm dia with ball valve of pressure 25 KG/Sqcm
Supply and fixing Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating pendent type.
Minal Engineers
Saviour Security Systems
GANGAJAL
Global Fire Protection System
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .