Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹41.5 L
EMD Value
₹83,066
Closing Date
27 Aug 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Deputy Director(Admin)RIMS.
Regional Institute of Medical Sciences, Imphal - 795001.
Construction of PSA Plant with Oxygen Cylinder store near Covid hospital, RIMS-Imphal.(SH Building,Land development,Soil stabilisation,Culvert,Ramp).
2021_RIMS_643855_1
84/2021-22/RIMS/Imphal
Open Tender
Civil Works
Works
60 days
As Per Tender Document
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Director RIMS Imphal
₹83,066
28 Aug 2021
17 Aug 2021
28 Aug 2021
17 Aug 2021
27 Aug 2021
17 Aug 2021
90 days
Amount
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead upto 50 cm and lift upto 1.5 metres
Hard/dense soil
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 metres including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres
Loose/Soft Soil
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Dry boulder pitching in floor
Providing and filling in foundation trenches and at the back of abutments, wing walls etc. and below pipe bed in layers not exceeding 150 mm thick including watering and compacting including all lead and lifts.
a) Filter behind abutment, wing and return wall.
Earth work in surface excavation exceeding 30 cm in depth but exceeding 1.5 metres in width as well as 10 sqm on plan i/c disposal of excavated earth lead upto 50 m and lift upto 1.5 m disposal soil to be levelled and neatly dressed in
Earth work in rough excavation banking excavated earth in layer not exceeding 20cm depth, breaking clods, watering rolling each layer with 1/2 tonne roller or wooden or steel rammer rolling every third and topmost layer with power roller of minimum 8 tonne and dressing up embankment for roads, floods banks guide banks and filling up ground, depression lead upto 50 metres and lift upto 1.5 m in
Hard Shale
Filling in plinth with sandy soil under floors including watering, ramming, consolidation and dressing complete.
Treatment of soil by boring, filling and compacting granular materials with the following specification i) boring by bailer with casing at required spacing and of required depth and diameter 600mm stone column
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering
i) 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with
1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up to floor five level excluding cost of centering,shuttering, finishing and reinforcement :
1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete
Providing form works i/c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for in-situ reinforced concrete and plain concrete work in : [Using 12 mm shuttering ply]
a) Foundation, footings, bases of columns etc. and mass concrete.
b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
c) Sides or soffits of beams, beam haunchings, cantilevers, girders, bressumers and lintels not exceeding 1m in depth.
d) Vertical surface such as walls (any thickness), partition and the like i/c attached pilasters, buttresses, plinth and the string courses and the like
e) Flat surface such as suspended floor, roofs landings and the like floors etc. upto 200 mm in thickness
2nd class (local first class) brick work in foundation and plinth in c. m. 1 : 3 (1 cem : 3 fine sand).
Half brick masonry 2nd class (local 1st class) in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure.
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide zinc chrome primer conforming to IS:2074-1979) welded and bolted including special shape washer etc. complete.
Electric resistant welded tube (Conforming to IS:1611-1979)
Trapzoidal Pre-painted Profile Sheet roofing of approved brand DYNA Roof or equivalent with selt drilling screws of 68 mm long Xylon coated screws with PVC washer & caps complete, exclding the coat of purlins & trusses.
Pre painted Galvalume Sheet (PPGL)
i) Profile sheet 0.50 mm/4.2 kgs/sqm
Supplying and fixing 4mm dia G.I wire netting fencing of diagonal mesh 100x100 mm weighing 0.10kg/m straining and fixing with galvaninised mild steel wire, staples for steel pins etc as directed
12 mm cement plaster 1:3 (1 cement: 3 fine sand)
P/F 1 mm thick M.S. sheet garage doors with frame of 40 X 40 X 6 mm, angle iron 3.15 mm M.S. gusset plate at the junction of corners with handles, stoppers of locking arrangement etc. i/c applying a priming coat of red lead paint.
Using M.S. angles 40 x 40 x 6mm for diagonal braces.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Painting (two or more coats) with plastic emulsion paint of approved quality on new work except walls to give an even shade.
Applying ready mixed priming coat (Red lead primer of approved quality) on steel work.
Painting (two or more coats) with synthetic enamel paint of approved quality all shades except black or chocolate on steel on new work to give an even shade.
Finishing walls weather shield paint of approved quality on new work(three or more coats) to give even shade.
M/S Y SOMORJIT SINGH
M/S L SHANTIKUMAR SINGH
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .