Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.6 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹50.2 L+₹3.6 L (7.71%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹50.3 L+₹3.7 L (7.88%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹51.8 L+₹5.2 L (11.0%)Rejected-Finance 4 MARIA COLONY FATEHABAD 125050 | FATEHABAD | FATEHABAD | HARYANA | 125050 | L4 | Rejected-Finance Rejected |
Tender Value
₹48.0 L
EMD Value
₹96,100
Closing Date
8 Jan 2021, 3:00 pmClosed
Executive Engineer
PHE Divn. , Mandi Dabwali, Ekta Nagri, Near Anaj Mandi, Mandi Dabwali
Laying of 300mm id RCC Pipe Channel 100 Mtrs., Construction of 1 No. S/S Tank of size 30.5m x 30.5m x 3.66 Mtrs., 1 No. High Level Tank of size 9.45m x 6.40m x 1.83 Mtrs., 1 No. Filter Beds of size 6.71m x 4.27 Mtrs, 1 No. Clear Water Tank
2020_HRY_153602_1
SE, PHEC, Sirsa memo No. 11705-06 Dt. 17.12.2020
Open Limited
Civil Works
Works
180 days
EE, PHE Divn., Mandi Dabwali
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,500
₹96,100
Yes
11 Feb 2021
18 Dec 2020
8 Jan 2021
18 Dec 2020
8 Jan 2021
18 Dec 2020
Amount
N.S. Item
Supply & erection of Horizontal spindle split casing type pumping sets of minimum four (4) star rating duties directly coupled to AC squarrel cage induction type motor with 1450 RPM, 3 Phase, 50 Hz and accessories as described in Schedule No.II complete in all respect with priming arrangement with complete base frame. (a) Raw Water Pump Set 600 LPM with 12.00 Mtrs. Head.
(b) Clear Water Pump Set 600 LPM with 40 Mtrs. Head.
Supply and fixing following CI D/F pipe and specials/ bell mouth / including cost of Jointing materials, laying, jointing, refilling including making adequate supports of masonry/ concrete for delivery and suction pipe from bell mouth in the collecting tank upto the rising main laid by the department as per plan shown from the foundation wall of the pump chamber for all the raw water and clear water pumping sets at water works, as per specification given in schedule No. II for For Pumping Machinery (B) D.I. Pipes including cutting, threading & blank flange fitting (ii) 150mm i/d
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stoutedwith suitable angle iron frame works and completely powder coated of approximate size 1200x900mm and 400mm deep having following item. A) For raw water pump sets for 600 LPM x 12 M Head = 2 No. (a) Main switch 63 Amp 2 No (L&T Siemens, ABB) (b) Volt meter 100x100mm range 0 to 500 Volt 1 no. (AE/KAPPA/L&T) (c) Amp. meter 100x100 mm range 0 to 100 Amp 2 No. (AE/KAPPA/L&T). (d) CT 100/3 = Nos (AE/KAPPA/L&T). (e) VSS 1 No. & ASS 2 No. each of approved make. (f) SPP 1 No. of approved Make. (g) Motor starter, star delta 2 No. for 600 LPM x 12 M Head Motor (L&T Simens AAB) (h) Capacitor of suitable capacity - 2 Nos. i) Indicating Lamp - One Set. j) Change over switch .. Amp. = 1 No.
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stoutedwith suitable angle iron frame works and completely powder coated of approximate size 1200x900mm and 400mm deep having following item. A) For Clear water pump sets for 600 LPM x 40 M Head = 2 No. (a) Main switch 63 Amp 2 No (L&T Siemens, ABB) (b) Volt meter 100x100mm range 0 to 500 Volt 1 no. (AE/KAPPA/L&T) (c) Amp. meter 100x100 mm range 0 to 100 Amp 2 No. (AE/KAPPA/L&T). (d) CT 100/3 = Nos (AE/KAPPA/L&T). (e) VSS 1 No. & ASS 2 No. each of approved make. (f) SPP 1 No. of approved Make. (g) Motor starter, star delta 2 No. for 600 LPM x 40 M Head Motor (L&T Simens AAB) (h) Capacitor of suitable capacity - 2 Nos. i) Indicating Lamp - One Set. j) Change over switch .. Amp. = 1 No.
Providing and fixing exhaust fans 18" i/d (450mm) complete with suitable G.I. Sheet of approved make complete in all respects.
Providing & fixing ceiling fan 1400mm (56") with speed adjuster of reputed make (make Crompton, Usha, Bajaj, Orient) complete in all respects.
Taking out filter media from filter bed & placing the same into filter beds after washing of cleaning complete in all respects. Top layer
2nd Layer
3rd, 4th & Bottom
Drawing out RCC Bed Plates of size 16"x16"x2" from filter bed & placing the same after washing & cleaning.
Washing, cleaning of central drains & sub drains of filter beds.
Credit for old pumping machinery raw water complete job
Credit for old pumping machinery clear water complete job
Bidder Name
Amount
Rajesh Kumar Contractor(GSTN-06AHNPK5447M2ZR)
Raj Kumar, Contractor(GSTN-06AIZPK9656K1Z6)
Lokesh Kumar, Contractor(GSTN-06AYAPK6590K1Z4)
RANBIR SINGH(GSTN-06CBZPS1549A2ZB)
Raj Kumar, Contractor
Rajesh Kumar Contractor
Lokesh Kumar, Contractor
Lokesh Kumar, Contractor
Raj Kumar, Contractor
Rajesh Kumar Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .