Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹6.6 Cr 2 YOUR TENDER SUBMITTED ON 10 08 2024 ON E TENDER WEBSITE 3 YOUR PRICE BIDOPENED ON 30 08 2024 ON E TENDER WEBSITE | ₹6.6 Cr |
Tender Value
₹8.6 Cr
EMD Value
₹8.6 L
Closing Date
20 Nov 2025, 3:00 pmClosed
Construction of ICAI Bhawan at Gwalior (M.P.)
NBCC/SBG-MP/ICAI/NIT/2025/11
NBCC/SBG-MP/ICAI/NIT/2025/11
Open Tender-Domestic
Civil Works General
Gwalior, Madhya Pradesh
₹11,800
₹8.6 L
9 Dec 2025
5 Nov 2025
20 Nov 2025
20 Nov 2025
1 Dec 2025
BILL OF QUANTITIES
Name of work : Proposed Construction of Institute of Chartered Accountants of India At District- Gwalior(M.P.)
Institute of AMOUNT (IN RS)
Chartered Over head
S.No Particulars Underground Tank Septic Tank Rain Water
Accountants of Tank RCC Boundary Wall Drain DSR NON DSR
13 Non-Schedule Items - - - 79,27,211.22
TOTAL AMOUNT (NON DSR) 0 0 0 0 0 79,27,211
TOTAL AMOUNT (NON DSR) 0 0 0 0 0 79,27,211
GRAND TOTAL (CIVIL WORKS DSR & NON-DSR ) (In Rs) (A) 4,90,91,350.12
GRAND TOTAL (CIVIL WORKS DSR & NON-DSR ) (In Rs) (A) 4,90,91,350.12
PLUMBING & OTHER CIVIL WORKS
14 Sanitary Installations 4,92,783.40
15 Drainage Installation 73,289.05
16 Water supply Installations 1,15,874.00 - 39,341.00 - - 7,19,108.30
17 External Sewage Drainage System 15,163.50 2,88,599.70 - - - 11,69,853.60
External Storm Water Drainage
1 Digitally signed by NIRAJ
BILL OF QUANTITIES
Name of work : Proposed Construction of Institute of Chartered Accountants of India At District- Gwalior(M.P.)
Institute of AMOUNT (IN RS)
Chartered Over head
S.No Particulars Underground Tank Septic Tank Rain Water
Accountants of Tank RCC Boundary Wall Drain DSR NON DSR
19 Bore well 5,14,638.40
Landscappping Work (Horticulture)
FootPath With PCC base & 60mm
21 Paver Blocks 2,65,338.60
TOTAL AMOUNT (NON DSR) 0
TOTAL AMOUNT (NON DSR) 0
PLUMBING & OTHER CIVIL WORKS (In Rs) (B) 56,13,121.42
FIRE FIGHTING WORKS
22 Fire Fighting & Accessories 12,59,726.00 89,198.00
TOTAL AMOUNT (DSR) 12,59,726.00
TOTAL AMOUNT (DSR) 12,59,726.00
TOTAL AMOUNT (NON DSR) 89,198.00
TOTAL AMOUNT (NON DSR) 89,198.00
GRAND TOTAL (FIRE FIGHTING WORKS) (In Rs) (C) 13,48,924.00
GRAND TOTAL (FIRE FIGHTING WORKS) (In Rs) (C) 13,48,924.00
ELECTRICAL WORKS (Internal) DSR NON DSR
23 Internal Electrical 37,67,862.00 44,04,908.00
Fire Alarm System
TOTAL AMOUNT (DSR) 82,92,924.00
TOTAL AMOUNT (DSR) 82,92,924.00
TOTAL AMOUNT (NON DSR) 96,07,530.00
TOTAL AMOUNT (NON DSR) 96,07,530.00
TOTAL (ELECTRICAL WORKS INTERNAL) (In Rs) (D) 1,79,00,454.00
ELECTRICAL WORKS (External)
36 External Electrical 10,83,051.00 18,96,019.00
37 MOTORIZZED STEEL GATES - 10,80,000.00
TOTAL AMOUNT (DSR) 24,79,637.00
TOTAL AMOUNT (DSR) 24,79,637.00
TOTAL AMOUNT (NON DSR) 32,30,383.00
TOTAL AMOUNT (NON DSR) 32,30,383.00
TOTAL (ELECTRICAL WORKS EXTERNAL) (In Rs) (E) 57,10,020.00
2 Digitally signed by NIRAJ
BILL OF QUANTITIES
Name of work : Proposed Construction of Institute of Chartered Accountants of India At District- Gwalior(M.P.)
Institute of AMOUNT (IN RS)
Chartered Over head
S.No Particulars Underground Tank Septic Tank Rain Water
Accountants of Tank RCC Boundary Wall Drain DSR NON DSR
Furniture & Statue
38 Furniture 54,90,473.63
Maa Saraswati Statue in marble
TOTAL AMOUNT (DSR)
TOTAL AMOUNT (DSR)
TOTAL AMOUNT (NON DSR) 64,90,473.63
TOTAL AMOUNT (NON DSR) 64,90,473.63
TOTAL (Furniture & Statue ) (In Rs) (F) 64,90,473.63
TOTAL (In Rs) (A+B+C+D+E+F)= G 8,61,54,343.17
3 Digitally signed by NIRAJ
BILL OF QUANTITIES
Name of work : Proposed Construction of Institute of Chartered Accountants of India At District- Gwalior(M.P.)
ABSTRACT OF COST
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
1.00 Earth Work
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm
in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth
lead upto 50 m and for all lift, as directed by Engineer-in-charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm
2 2.7 in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth -
lead upto 50m and lift upto 1.5m, as directed by Engineer-in-charge.
2.7.3 Hard rock (blasting prohibited) Cum - - 1,432.95 -
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers
3 2.25 not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and Cum 827.20 61.80 889.00 196.00 1,74,244.71
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto
4 2.25 (a) a lead of 5km also including ramming and watering of the earth in layers not exceeding 20cm in foundation Cum 204.00 204.00 700.50 1,42,902.00
trenches, plinth, sides of foundation etc. complete for all lift.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and
dressing complete.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to
6 2.31 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50m outside Sqm 951.28 76.50 1,027.78 17.60 18,088.96
the periphery of the area cleared.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost
of chemical emulsion) :
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including
2.35.3 drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the -
existing floor:
With Chlorpyriphos/Lindane E.C. 20% with 1%
Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced
cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe
8 20.1 working load not less than specified, excluding the cost of steel reinforcement but including the cost of
shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment
shall be measured from top of shoe to the bottom of pile cap) :
2.00 Concrete Work -
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources: 10 graded stone aggregate 40 mm
nominal size derived from natural sources)
4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) Cum 50.00 2.17 2.60 0.90 3.26 7.65 66.58 6,812.00 4,53,515.71
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-
9 4.10 III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal size derived from natural Sqm 81.00 - 81.00 410.85 33,278.85
4 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg
10 4.13 per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of Sqm 82.00 82.00 146.15 11,984.30
cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived
from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm
11 4.17 thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, Sqm 110.00 110.00 749.30 82,423.00
including necessary excavation, levelling & dressing & finishing the top smooth.
Total of sub-head Concerete Work (2.0)
3.00 Reinforced Cement Concrete -
5.9 Centering and shuttering including strutting, propping etc. and removal of form for : -
12 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete Sqm 339.05 37.24 64.34 44.48 8.50 493.61 392.15 1,93,569.16
13 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. Sqm 181.00 57.60 112.20 306.00 656.80 842.50 5,53,354.00
14 5.9.3 Suspended floors, roofs, landings, balconies and access platform Sqm 1,209.00 19.60 1,228.60 927.25 11,39,219.35
16 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 1,283.00 13.36 90.00 1,386.36 736.40 10,20,915.50
17 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 826.00 72.30 126.24 1,024.54 961.30 9,84,890.30
18 5.9.7 Stairs, (excluding landings) except spiral-staircases Sqm 85.00 85.00 764.95 65,020.75
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands,
copings, bed plates, anchor blocks and the like
20 5.9.19 Weather shade, Chajjas, corbels etc., including edges Sqm 84.00 84.00 951.10 79,892.40
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
binding all complete upto plinth level.
5.22.A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 26,000.00 1,423.52 1,992.80 1,741.20 1,275.00 32,432.52 107.85 34,97,847.28
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
binding all complete above plinth level.
5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 50,000.00 974.65 128.00 900.24 52,002.89 107.85 56,08,511.69
23 5.30 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. Metre 111.22 111.22 78.40 8,719.65
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland
Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103
to accelerate / retard setting of concrete, to improve durability and workability without impairing
24 5.33 strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the -
cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for
the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in
design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times
of the specified minimum cement content, the contractor shall have discretion to either re-design the mix
or bear the cost of extra cement.
5.33.1 All works upto plinth level -
Concrete of M30 grade with minimum cement
content of 350 kg /cum
25 5.33.2 All works above plinth level upto floor V level. -
Concrete of M30 grade with minimum cement
content of 350 kg /cum
26 5.35 Add for using extra cement in the items of design mix over and above the specified cement content therein. Quintal 40.00 0.75 1.25 0.75 0.25 1.75 44.75 733.50 32,824.13
4.00 Masonry Work -
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V level.
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) Sqm 45.00 45.00 1,123.80 50,571.00
Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive
strength in super structure above plinth level up to floor V level in
5 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
5.00 Cladding Work -
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for
kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved
29 8.2 shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints -
treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding
and polishing to edges to give high gloss finish etc. complete at all levels.
8.2.2 Granite of any colour and shade -
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8
cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding
30 8.10 the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded -
stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
8.10.1 White Agaria Marble Stone SQM 5.40 5.40 3,500.00 18,900.00
Total of sub-head Cladding Work (5.0) 9,07,969.50 - - - - - - 9,07,969.50
Wood & PVC Work
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core
32 9.20 of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with -
vertical grains or cross bands and face veneers on both faces of shutters.
9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Sqm 105.00 105.00 3,473.85 3,64,754.25
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door
shutters (over all area of door shutter to be measured).
34 9.26 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). Sqm 49.00 49.00 106.70 5,228.30
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25 mm with two chromium
plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or
round bars etc. including priming coat with approved steel primer all complete
9.48.1 Fixed to steel windows by welding kg 1,753.88 1,250.00 3,003.88 219.10 6,58,149.01
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded)
(overall area of door shutter to be measured):
9.24.1 Rectangular or square Sqm 1.00 1.00 199.15 199.15
Providing and fixing bright finished brass night latch of approved quality including necessary screws etc.
Total of sub-head Wood & PVC Work (6.0)
7.00 Steel Work -
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked
together through their entire length and jointed together at the end by end locks, mounted on specially
designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and
53 10.6 pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs -
manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -
part 1 and M.S. top cover of required thickness for rolling shutters.
10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover Sqm 25.00 25.00 3,653.20 91,330.00
54 10.7 Providing and fixing ball bearing for rolling shutters. Sqm 4.00 4.00 492.35 1,969.40
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset
54 10.5 plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of -
approved steel primer.
10.5.2 Using flats 30x6mm for diagonal braces and central cross piece sqm 5.0 5.04 5,563.75 28,041.30
6 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
Steel work welded in built up sections/ framed work, including cutting,
56 10.25 hoisting, fixing in position and applying a priming coat of approved steel -
primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets,
gates and similar works
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing,
staircase railing and similar works, including applying priming coat of approved steel primer.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.,
including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the
same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary
58 10.28 accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of kg 300.00 300.00 772.40 2,31,720.00
the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for
payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such
as nuts, bolts, fasteners etc.).
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and
nuts & bolts complete.
10.29.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides Sqm 143.00 143.00 1,133.55 1,62,097.65
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed
60 11.26 with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement -
mortar 1 : 4 (1 cement : 4 coarse sand) :
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick
61 11.27 cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match Sqm 3.50 3.50 2,354.70 8,241.45
the shade of the slabs, including rubbing and polishing complete.
62 11.31 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. Metre 50.00 50.00 191.40 9,570.00
Providing and laying full body (Homogeneous) Vitrified floor tiles in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of
63 11.41 approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), -
jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching
pigments etc., complete.
Providing and laying full body (Homogeneous) Vitrified tiles in different sizes (thickness to be specified
by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in
64 11.46 all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 -
coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement &
matching pigments etc. complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as
curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone
65 11.56 slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with -
cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing
curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
11.56.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. sqm 400.00 400.00 4,481.30 17,92,520.00
Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS:15622, of approved brand & manufacturer, in all colours
and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse
66 11.41 sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the -
joints with white cement and matching pigments etc. The tiles must be cut
with the zero chipping diamond cutter only . Laying of tiles will be done
with the notch trowel, plier, wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles gently and easily
11.41.A.3 Glazed Vitrified tiles Matt/Antiskid finish of size -
7 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
11.41.A.3. Size of Tile 600 x 1200 mm
Total of sub-head Flooring (8.0)
9.00 Roofing -
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and
down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished
70 12.22 with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and Each 12.00 12.00 298.25 3,579.00
making and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A,
71 12.41 including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) -
Single socketed pipes
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid
72 12.42 PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : -
5382, leaving 10 mm gap for thermal expansion
12.42.1 Coupler -
12.42.2 Single pushfit Coupler -
12.42.4 Single tee without door -
12.42.6 Shoe (Plain) -
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water
pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including
73 12.43 cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. -
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level,
suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm,
both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and
of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T”
of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm
center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm
made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of
600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the
grid including, required cutting/making, opening for services like diffusers, grills, light fittings,
fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of
size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI
adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to
center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester
paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge
8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced
with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with
12.58.1 minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having sqm 140.60 140.60 1,789.45 2,51,596.67
perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having
an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing
8 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level,
suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm,
both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and
of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T”
of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm
center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm
75 12.52 made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of
600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the
grid including, required cutting/making, opening for services like diffusers, grills, light fittings,
fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of
37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods
with galvanised butterfly level clips of and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white
color tiles of size 595x595 mm and 0.5 mm thick with 8 mm
drop; made of GI sheet having galvanizing of 100 gms/sqm
(both sides inclusive) and 20% perforation area with 1.8 mm
12.52.2 dia holes and having NRC (Noise Reduction Coefficient ) of sqm 796.68 796.68 2,068.75 16,48,126.58
0.5, electro statically polyester powder coated of thickness
60 microns (minimum), including factory painted after
bending and perforation and backed with a black Glass fiber
acoustical fleece.
12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard,
manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant
12.52.3 PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the sqm 152.80 152.80 2,215.15 3,38,474.92
face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side
metalized polyester film so as to make the tile a completely sealed unit.
10.00 Finishing -
75 13.4 12 mm cement plaster of mix -
76 13.5 15 mm cement plaster on rough side of single or half brick wall of mix: -
77 13.16 6 mm cement plaster of mix -
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand)
finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the
surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound )
81 13.83 content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats -
wherever required to achieve even shade and colour.
Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than
82 13.48A 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior -
paint of required shade with silicon additives.
New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer
0.90 litre/10 sqm.
83 13.50 Applying priming coat: -
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/
84 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : -
11.00 Aluminium Work -
9 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
Total of sub-head Alluminium Work (11.0) - - - - - - -
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture,
including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing
85 21.18 arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction Sqm 5.10 5.10 5,325.90 27,162.09
of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
12.00 Water Proofing -
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of
89 22.3 W.C., kitchen and the like consisting of: -
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS
2645 in recommended proportions including rounding off junction of vertical and horizontal surface.
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound
in recommended proportion including rounding off junction of vertical and horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. -
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and
pasted to each other with bitumen @ 1.7 kg/sqm).
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to
the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior,
sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of
5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts
integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative
90 22.23 (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as -
specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with
control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The
crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work
shall be carried out all complete as per specification and the direction of the engineer-in-charge. The
product performance shall carry guarantee for 10 years against any leakage.
22.23.2 For horizontal surface one coat @1.10 kg per sqm. sqm 689.00 689.00 362.80 2,49,969.20
22.23.1 For vertical surface two coats @ 0.70 kg per sqm per coat sqm 45.00 45.00 472.90 21,280.50
Total of sub-head Water Proofing (12.0) 3,08,960.10 - - - - - - 3,08,960.10
13.00 Non-Schedule Items
Providing and fixing factory made UPVC white colour fixed glazed windows/ ventilators comprising of UPVC
multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2
mm thick galvanized mild steel section made from roll forming process of required length (shape & size
according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners
100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless
steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion
(ifrequired) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of
water etc. Afterfixing frame the gap between frame and adjacent finished wall shall be filled with weather
proof silicon sealant over backer rod of required size and of approved quality, all complete as per
approveddrawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant
shall be paid separately).
Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth &
width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no
extra payment on this account shall be made.
Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall
0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
10 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension
comprising of UPVC multi-chambered frame with in- built roller track and sash extruded profiles duly
reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of
required length (shape & size according to UPVC profile), appropriate dimension of UPVC extruded glazing
beads and UPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks
with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners
100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profileof frame
& sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing
hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall
shall be filled with weatherproof silicon sealent over backer rod of required size and of approved quality,
all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire
mesh and silicon sealent shall be paid separately)Note: - For UPVC frame, sash and mullion extruede profiles
minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile
dimension in higher side shall be accepted but no extra payment on this account shall be made.
Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh
panels) made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single Sqm 139.68 139.68 7,444.20 10,39,805.19
glazing bead/double glazing bead of appropriate dimension. (Area ofwindow above 1.75 sqm).
Providing and fixing zinc alloyed (white powder coated) touch lock for UPVC sliding window with necessary
screws etc. complete.
4 NSR 4 Providing and fixing steel roller for UPVC sliding window with necessary screws etc. complete. each 144.00 144.00 85.04 12,246.47
5 NSR 5 Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete:. -
Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with necessary screws
etc. complete :
7 NSR 7 Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : -
ProvidingandfixingStainlesssteel hanging type floor door stopper with necessary screws, etc.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo
9 NSR 9 with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm) with necessary each 46.00 46.00 920.86 42,359.57
accessories and screws etc. complete.
Providing and fixing 16mm thick gang saw cut mirror polished premoulded and prepolished machine cut Granite
of approved shade, colourand texture of Granite Door frame. in cement mortar 1:3 (1 cement :3 sand)
including pointing with an admixture of pigment to match the shade including fixing of granite stone door
10 NSR 10 frame with epoxy resin based adhesive including secured to the backing by means of cramps, drilling of hole -
with rawl plugs and screws 75mm long cleaning etc. complete. Including rubbing, curing, moulding and
polishing edges to give high glossy finish and drilling of hole for fixing stainless steelhings, aldrop,
towerboltetc complete at all levels as per instruction of Engineer-in-Charge.
(i) Granite Doorframe for 100mm thick wall Thickness. Meter 30.00 30.00 1,194.38 35,831.54
(ii) Granite Doorframe for200mmthickwall Thickness. Meter 239.20 239.20 1,756.47 4,20,147.23
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door
shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate
and natural fibers (wood powder/ rice .husk/wheat husk) and non toxic additives (maximum toxicity index of
12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N
(Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of
11 NSR 11 flame of Class A category with property of being termite/borer proof, water/moisture proof and fire -
retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded
star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt
hinges and necessary
S.S screws shall be paid separately)
28 mm thick WPC (Wood polymer composite) solid plain flush door shutter Meter 18.00 18.00 3,835.31 69,035.52
11 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
Providing and fixing Glass Reinforced Concrete (G.R.C) Screens/ Jali customized as per design, dimensions as
per drawings in approved shade in overall thickness of 40mm, or inner design membrane between 30-35mm and
borders 50mm, casted with layering technique Power Spray methodology have weight approximately between 3.75 -
4.5 Kg per Sq. Ft. The screens casting shall take place with layering methodology using- Direct Power Spray
machines. The screens shall be casted from 53 grade White Portland Cement manufactured by Fine graded,
sieved Quartz & Silica Sand, reinforced with Alkali Resistant Glass Fiber manufactured between 4-5% by
having Zirconia content at least 16%, Super Plasticizers and UV resistant Synthetic inorganic pigments
should be used for pigmentation
Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with
water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st
13 NSR 13 quality/ premium quality including grouting the joints with white cement and matching pigments etc. complete -
For floor glossy/ rustic /stain/matt finished laid on 20mm thick cement mortar 1:4 (1 cement:4sand)
Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water
absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality /
14 NSR 14 premium in skirting, riser, dado and wall lining laid our 12mm thick cement mortar 113 including grouting -
the joints with white cement and matching pigments etc.
For skirting, riser, dado and wall lining etc.
glossy/ rustic /stain/mattfinished in all colours and shades
Providing and fixing 50 micron thick reflective one way type heat/light control film to window/door glazing
with complete accessories as per direction of Engineer-in- charge of approved brand and make.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia
140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top
16 NSR 16 lid shall be screwed into the cast iron/ M.S. sheet box by means of Each 100.00 100.00 173.96 17,395.56
3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 16mm dia M.S. bar bent to
shape as per standard drawing.
Supplying & installing waterproofing treatment by using 1.2 mm thick HDPE membrane before casting of the
base RCCslab. The pre-applied membrane gets bonded to the underneath of the poured concrete used as base
slab. The membrane shall consist of a thick HDPE film, a highly aggressive pressure sensitive adhesive and
weather resisting coating which bonds integrally to poured concrete of base slab. The membrane shall
conforms to basement waterproofing protection to grades 2, 3 & 4 as defined in BS 8102:2009. The
17 NSR 17 waterproofing membrane shall have following minimum properties: Sqm - 11.56 9.80 21.36 2,066.25 44,135.04
a)Resist hydrostatic pressure of up to 70 m head of water as per ASTM D5385;
b)Puncture Resistance of 950 N (as per ASTM E154)
c)Elongation of >400 % (as per ASTM D412)
d)Peel Strength of concrete: >1500 N/m (as per ASTM D903)
e)Tensile strength of 28.2 MPA (as per ASTM D412).
Providing and applying 2.0 mm thick twin colour flexible PVC waterproofingmembrane. Flexibility under
lowtemperatures as per EN 495-5 should be < - 20degC. On all horizontal surfaces Geotextile300 Gsm to be
laid over PCC, than laying PVC membrane over Geotextile and to be sealed with hot air welding method at all
18 NSR 18 joints and over PVC membrane provide 300Gsm Geotextile Then protection screed of suitable thickness. On all Sqm - 28.80 35.07 63.87 1,983.44 1,26,682.25
vertical surfaces Geotextile 300 Gsm to be laid along with Vertical wall, than laying PVC membrane over
Geotextile and to be sealed with hot air welding method at all joints and over PVC membrane providing
protection layer of Drain Board HDPE Dimple sheet before backfilling of soil.
Granite work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work),
backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement: 3 sand) including
19 NSR 19 pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match
the marble shade: (To be secured to the backing by means of cramps, which shall be paid for separately).
Area of slab over 0.50 sqm
Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other
colors of glitter
12 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
Providing and Installation of acoustical wall panelling fabric finish hardened square edge, FR grade fabric
(colour as approved by Egnineer in charge) wrapped soft fibre core (glass fibre) panel having metal framing,
20 NSR 20 of size 600x2100x25mm having density 100-120Kgs/ m3, weight 3.0kg/m2 NRC up to 0.9 installed by using Sqm 253.27 - - 253.27 8,925.28 22,60,504.47
impaling clip. Impaling clips are attached directly to the wall/frame work with the points extending
outward. Then panels shall positioned and pressed into place.
Providing & Fixing Fabric Acoustic Wall Paneling System of size 1200mm.maximum in width & Length as required
as per site Condition with 25mm thick stretch half / full wrap rigid vinyl tracks to be fix on existing
surface with PVC insert and screws as required pattern in panel as Per required module. 25mm thick acoustic
rockwool pad of 100kg density Fire Class A-1 as per EN 13501, NRC <0.70 to be fill in panel fixed by rubber
21 NSR 21 adhesive. Approved fabric to be grip in stretch track by tucking tools to make panel in proper line and Sqm 277.45 - - 277.45 6,504.96 18,04,800.93
level with wrinkle free finish. The stretch track create V groove / Butt joint in each panel. Complete
as per satisfaction by Engineer in charge.
Washed stone grit plaster on exterior walls of height upto 10 M. aboveground level in two layers, under
layer 12mm cement plaster 1:4 (1 cement : 4 sand ) furrowing the under layer with scratching tool, applying
cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1
22 NSR 22 cement : 1/2 sand : 2 stone chipping 10mm nominal size) in panels with groove all around asper approved Sqm - - 300.00 300.00 505.30 1,51,589.88
pattern including scrubbing and washing, the top layer with brushes and water to expose the stone
chippings,complete as per specification and direction of Engineer- in- charge (Payment for providing grooves
shall be made separately).
SS Tactile Strip with Stem each 144.00 - - - 144.00 200.60 28,886.57
Total of sub-head NSR (13.0) 79,27,211.22
14.00 Sanitary Installations -
Sanitary Installation (As per D.S.R.) -
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of
94 17.7 standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever -
17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Each 12.00 12.00 2,648.85 31,786.20
Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10
litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm
95 17.3 flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved -
municipal design complete, including painting of fittings and brackets, cutting and making good the walls
and floors wherever required :
17.3.1 W.C. pan with ISI marked white solid plastic seat and lid Each 11.00 11.00 8,006.60 88,072.60
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S
trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled
96 17.1 device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting -
and making good the walls and floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440
mm with integral type foot rests
Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate
to Eureopean type W.C. of quality and make as approved by Engineer - in-charge
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC
automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and
98 17.5 clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other -
couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors
wherever required :
Single half stall urinal with 5 litre P.V.C. automatic flushing
Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm
99 17.72 from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 Each 11.00 11.00 231.95 2,551.45
13 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with
concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not
less than 190 gms.
101 18.54 Providing and fixing PTMT bib cock of approved quality and colour. -
18.54.1 15mm nominal bore, 86 mm long, weighing not less than 88 gms Each 6.00 6.00 125.60 753.60
18.54.3 15 mm nominal bore, 165 mm long, weighing not less than 110 gms Each 7.00 7.00 176.85 1,237.95
102 18.55 Providing and fixing PTMT stop cock of approved quality and colour. -
18.55.1 15 mm nominal bore, 86 mm long, weighing not less than 88 gms Each 10.00 10.00 118.50 1,185.00
Providing and fixing C.P. brass angle valve for basin mixer and points of approved quality conforming to
18.53.1 15 mm nominal bore (For Shower) Each 10.00 10.00 574.30 5,743.00
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with
plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
105 17.28 Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete - - -
17.28.2 Flexible Pipe - - -
106 17.34 Providing and fixing toilet paper holder : - - -
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe
embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4
107 17.37 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : -
108 17.39 Providing and fixing plain bend of required degree. -
17.39.2.1 Sand cast iron S&S as per IS : 3989 Each 20.00 20.00 390.50 7,810.00
109 17.40 Providing and fixing heel rest sanitary bend -
17.40.1.2 Sand cast iron S&S as per IS : 3989 Each 12.00 12.00 548.70 6,584.40
17.40.2.2 Sand cast iron S&S as per IS : 3989 Each 12.00 12.00 504.30 6,051.60
Providing and fixing single equal plain junction of required degree with access door, insertion rubber
washer 3 mm thick, bolts and nuts complete.
17.43.2.2 Sand cast iron S&S as per IS - 3989 Each 8.00 8.00 665.05 5,320.40
111 17.44 Providing and fixing single equal plain junction of required degree : -
17.44.2.2 Sand cast iron S&S as per IS - 3989 Each 8.00 8.00 561.20 4,489.60
Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3
mm thick, bolts and nuts complete :
14 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
113 17.56 Providing and fixing terminal guard : -
17.56.1.2 Sand cast iron S&S as per IS - 3989 Each 10.00 10.00 506.00 5,060.00
17.56.2.2 Sand cast iron S&S as per IS - 3989 Each 5.00 5.00 404.75 2,023.75
114 17.57 Providing and fixing collar : -
17.57.1.2 Sand cast iron S&S as per IS - 3989 Each 10.00 10.00 513.15 5,131.50
17.57.2.2 Sand cast iron S&S as per IS - 3989 Each 5.00 5.00 362.05 1,810.25
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent
arm complete, including cost of cutting and making good the walls and floors :
17.60.1 100 mm inlet and 100 mm outlet -
17.60.2 100 mm inlet and 75 mm outlet -
116 18.21 Providing and fixing uplasticised PVC connection pipe with brass unions - - -
Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but
excluding the cost of pig lead :
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with
concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of
119 17.71 standard shape with bracket of the same materials with snap fittings of approved quality and colour, Each 11.00 11.00 168.35 1,851.85
weighing not less than 105 gms.
Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms
Total of sub-head Plumbing Work (14.0) 4,92,783.40 - - - - - 4,92,783.40
15.00 Drainage Installation
Providing and fixing PTMT grating of approved quality and colour
18.58.1 Circular type -
18.58.1.2 125 mm nominal dia with 25mm waste hole. Each 15.00 15.00 51.85 777.75
Providing & fixing on wall face unplasticised -Rigid PVC rain water pipes conforming to IS:13592 Type A
122 12.41 included jointing with seal ring conforning to IS:5382 leaving 10 mm gap for thermal expansion. (i)Single - -
socketed pipes.
Providing, fixing on wall face unplasticised - PVC moulded fittings /accessories for unplasticised - Rigid
123 12.42. PVC rain water pipes conforming to IS ; 13592 Type A including jointing with seal ring conforming to IS ; - -
5382 leaving 10 mm gap for thermal expansion.
15 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water
pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including
124 12.43 cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. -
Total of sub-head Drainage Installation (15.0) 73,289.05 - - - - - - 73,289.05
Water supply Installations
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot and cold
water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at
125 18.7 1.00 m spacing. this includes jointing of pipes and fittings with one step CPVC solvent cement and testing - -
of joints complete as per direction of engineer in charge.
Internal work -Exposed on Wall - -
18.7.4 32 mm nominal dia pipes Metre 150.00 150.00 518.75 77,812.50
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold
water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings
126 18.9 with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of -
Engineer in Charge.
External work -
129 18.17 Providing and fixing gun metal gate valve with CI wheel of approved quality (screwed ends) - -
18.17.1A 20mm dia, nominal bore Each 3.00 3.00 539.95 1,619.85
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats
18.18.2 20mm dia, nominal bore Each 2.00 2.00 462.50 925.00
18.18.3 32 mm dia, nominal bore Each 2.00 2.00 464.05 928.10
131 18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end) - -
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to
ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary
132 18.48A holes for inlet, outlet & over flow pipes. The base support Including fittings & fixtures for tank shall be Per Lit - - 11.00 -
paid separately.
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole
133 18.77 after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone Each 12.00 12.00 452.00 5,424.00
aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
Total of sub-head (16.0) Water Supply Installation (DSR)
17.00 External Sewage Drainage System -
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm
nominal size) all-round S.W. pipes including bed concrete as per standard design :
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry
135 19.4 chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not - -
less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
19.4.1 100x100 mm size P type - -
19.4.1.2 With Sewer bricks conforming to IS : 4885 each 5.00 5.00 2685.20 13,426.00
16 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
19.4.2 150 x 100 mm size P type. - -
19.4.2.2 With sewer bricks conforming to IS : 4885 each 5.00 6.00 11.00 2711.70 29,828.70
Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture
136 19.6 of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete -
Constructingbrick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab
with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size),
foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal
137 19.7 size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with -
floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per
standard design :
19.7.1Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal
19.7.1 dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of -
19.7.1.2 With Sewer bricks conforming to IS : 4885 each 5.00 5.00 12711.80 63,559.00
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter,
138 19.7.2 total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) -
19.7.2.2 With Sewer bricks conforming to IS : 4885 each 5.00 5.00 26244.70 1,31,223.50
139 19.8 Extra for depth for manholes - -
19.8.1.2 With Sewer bricks conforming to IS : 4885 metre 1.00 1.00 8654.25 8,654.25
19.8.2.2 With Sewer bricks conforming to IS : 4885 metre 1.00 1.00 10381.45 10,381.45
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement
mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3
coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse
140 19.11 sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 - -
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat
cement, all complete as per standard design :
1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter
conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement
19.11.1 concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, -
shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface
shall be paid for separately) :
19.11.1.2 With Sewer bricks conforming IS : 4885 each 2.00 2.00 24446.70 48,893.40
19.9Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top
in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1
141 19.9 : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 - -
coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat
of neat cement, all complete as per standard design
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter
conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement
19.9.1 concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, -
shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface
shall be paid for separately) :
19.9.1.2 With Sewer bricks conforming to IS : 4885 each 2.00 2.00 12600.40 25,200.80
19.10Extra depth for circular type manhole 0.91m internal dia (at bottom)
beyond 0.91 m to 1.67 m
19.10.2 With Sewer bricks conforming IS : 4885 metre 1.00 1.00 7448.45 7,448.45
143 19.12 Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m : -
19.12.2 With Sewer bricks conforming IS : 4885 metre 1.00 1.00 9674.40 9,674.40
17 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement
mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3
coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse
144 19.13 sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 - -
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat
cement, all complete as per standard design :
2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter
conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement
19.13.1 concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, - -
shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface
shall be paid for separately) :
19.13.1.2 With Sewer bricks conforming IS : 4885 each 2.00 2.00 52266.80 1,04,533.60
145 19.14 Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m : -
19.14.2 With Sewer bricks conforming IS : 4885 metre 1.00 1.00 22288.10 22,288.10
19.15Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6
146 19.15 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : - -
19.15.2 With 20 mm diameter round bar each 10.00 10.00 496.50 4,965.00
Making connection of drain or sewer line with existing manhole including breaking into and making good the
walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
147 19.21 nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished -
with a floating coat of neat cement and making necessary channels for the drain etc. complete
19.21.1 For pipes 100 to 250 mm diameter each 10.00 10.00 810.45 8,104.50
Raising manhole cover and frame slab to required level including dismantling existing slab and making good
the damage as required (Raising depth of manhole to be paid separately) :
19.26.1 Rectangular manhole 90x80 cm with rectangular cover 600 x 450 mm of grade LD - 2.5 each 1.00 1.00 2625.50 2,625.50
19.27Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement
149 19.27 : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard -
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4
coarse sand ) with precast R.C.C. vertical grating complete as per standard design
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
19.29Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1
151 19.29 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical -
grating complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including
S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Providing orange colour safety foot rest of minimum 6 mm thick plastic
encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to
IS: 1786, having minimum cross section as 23 mmx25 mm and over
all minimum length 263 mm and width as 165 mm with minimum 112
153 19.16 mm space between protruded legs having 2 mm tread on top surface Each 17.00 17.00 34.00 553.70 18,825.80
by ribbing or chequering besides necessary and adequate anchoring
projections on tail length on 138 mm as per standard drawing and
suitable to with stand the bend test and chemical resistance test as per
specifications and having manufacture’s permanent identification mark to
be visible even after fixing, including fixing in manholes with 30x20x15 cm
Providing and fixing in position pre-cast R.C.C. manhole cover and frame
of required shape and approved quality
Rectangular shape 600x450 mm internal
18 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick
155 19.32 honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 -
m long complete as per standard design.
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including
excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the
156 2.10 excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including -
consolidating each deposited layer by ramming,
watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m
2.10.1 All kinds of soil -
2.10.1.1 Pipes, cables etc., not exceeding 80 mm dia. metre 80.00 80.00 215.60 17,248.00
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. metre 50.00 50.00 352.15 17,607.50
Total of sub-head (17.0) Sewage Installation (DSR) 8,66,090.40 15,163.50 2,88,599.70 - - - - 11,69,853.60
18.0 External Storm Water Drainage System
Supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the
required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the
158 23.6 existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of cum 0.90 0.90 1,538.25 1,384.43
Engineer-in-charge.
Supplying, filling, spreading & levelling coarse sand of size range 1.5mm to 2mm, in recharge pit, in
159 23.7 required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in- cum 0.90 0.90 1,538.25 1,384.43
Total of sub-head (18.0) External Storm Water Insatallation (DSR)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS:
2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/
160 23.1 bore log, including hire & running charges of all equipments, tools, plants & machineries required for the -
job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
23.1.1 All types of soil -
23.1.2 Rocky strata including Boulders -
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS:
2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/
bore log, including hire & running charges of all equipments, tools, plants & machineries required for the
job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below
23.2.1 All types of soil - -
23.2.2 Rocky strata including Boulders - -
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well
casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges,
162 23.3 fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. Meter -
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well
screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings &
163 23.4 accessories etc. all complete, for all depths, as per direction of - -
Engineer-in-charge.
19 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/
164 23.8 medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of cum - 2,024.50 -
Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well
housing/ casing pipe, removable as per requirement, all complete for borewell of:
23.13.3 200 mm nominal size dia Each 1.00 1.00 321.15 321.15
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS:
2800 (part I), including necessary bolts & nuts of required size complete.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as
per IS:2800 (part I).
Total of sub-head (19.0)Borewell (DSR) 5,14,638.40 - - - - - 5,14,638.40
20.00 Landscappping Work (Horticulture) - -
Providing & laying Selection no. 1 doob grass turf with earth 50mm to
60mm thickness of existing ground prepared with proper level and ramming
with required tools wooden and than rolling the surface with light roller
168 2.34 make the surface smoothen and light watering the same maintenance for Persqm 300 300.00 87.50 26,250.00
30 days or more till the grass establish properly,as per direction of officer
Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m high, above
ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm 2 m
long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron rings in
two halves, fixing together at site with required six numbers of 8 mm dia
and 30 mm long bolts, including painting two coats with synthetic enamel
paint of approved brand and manufacture over a coat of primer. One name
169 2.16 plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the each 20.00 20.00 4,533.10 90,662.00
tree guard near the middle height and lettered CPWD / PWD/ any other
approved name. The tree guard shall be suitably fixed to the ground by
embedding four legs of tree guard in pits of suitable dia and to a depth of 25
cm, refilling the pits with soil and ramming, complete in all respect as per
satisfaction and direction of Officer-in-charge
Providing and stacking of Aspidistra, having 10 to 15 leaves well developed with fresh & healthy in 25 cm
size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves
in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge..
Providing and stacking of Euphorbia milli hybrid variety, having ht.30 cm to
172 6.13 45 cm with multi branch, full bloom, fresh and healthy leaves in 20 cm size each 20.00 20.00 70.00 1,400.00
of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Ipomea (Golden leaves),with fresh and healthy
173 6.15 leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the each 10.00 10.00 20.00 200.00
officer-in-charge
Providing and stacking of Iresine herbstii, of height 20-25 cm. full of branches well developed in 15 cm
size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge
Providing and stacking of Ophiopogon jaburan (variegated ), full of variegated leaves in 15 cm size of
Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Syngonium miniature dwarf, having height 30-45
176 6.27 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size each 20.00 20.00 42.00 840.00
20 cm. as per direction of the officer-in-charge.
Providing and stacking of Tradescantia, full of leaves in Earthen Pot/Plastic
Pot of size 15 cm. as per direction of the officer-in-charge.
20 Digitally signed by NIRAJ
Description of Item Unit Chartered Underground Over head Rain Water Rate (In Rs) Amount (In Rs)
No. Septic Tank Boundary Wall Drain Quantity
Accountants of Tank Tank RCC Harvesting
Providing and stacking of Acacia auriculiformis of ht 150-165 cm in bag
size of 25 cm as per direction of the officer-in-charge.
Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165
cm in bag size of 25 cm as per direction of the officer-in-charge.
Total of sub-head (20.0) Landscapping & Horticulture . (DSR)
21.00 FootPath With PCC base & 60mm Paver Blocks -
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) Cum 16.05 16.05 6,812.00 1,09,332.60
Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made
by block making machine
181 16.68 with strong vibratory compaction, of approved size, design & shape, laid Sqm 160.50 160.50 972.00 1,56,006.00
in required colour and pattern over and including 50 mm thick compacted
bed of coarse sand, filling the joints with line sand etc. all complete as per
the direction of Engineer-in-charge.
Total of sub-head (21.0) FootPath With PCC base & 60mm Paver Blocks 2,65,338.60 - - - - - - 2,65,338.60
22.00 Road Work & Other Items -
Preparation and consolidation of sub grade with power road roller of 8 to
12 tonne capacity after excavating earth to an average of 22.5 cm depth,
182 16.1 dressing to camber and consolidating with road roller including making sqm 1,026.50 1,026.50 218.9 2,24,700.85
good the undulations etc. and re-rolling the sub grade and disposal of
surplus earthwith lead upto 50 metres
16.1 Supplying and stacking at site
16.3.2 63 mm to 45 mm size stone aggregate Cum - - 1636.05 -
Laying, spreading and compacting stone aggregate of specified sizes
to WBM specifications in uniform thickness, hand picking, rolling with 3
wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade
184 16.4 and camber, applying and brooming requisite type of screening / binding Cum - - 1046.95 -
material to fill up interstices of coarse aggregate, watering and compacting
to the required density .
Supplying, stacking and Spreading 6 mm thick red bajri, watering and
rolling complete including preparation of the surface and rolling
16.6.1 With road roller/ hand roller sqm - - 24.45 -
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 40 mm nominal size) in pavements, laid to required slope and
186 16.42 camber in panels as required including consolidation finishing and tamping cum 84.95 84.95 7993.80 6,79,073.31
Providing and laying design mix cement concrete of M-30 grade, in roads/
taxi tracks/ runways, using cement content as per design mix, using coarse
sand and graded stone aggregate of 40 mm nominal size in appropriate
proportions as per approved & specified design criteria, providing dowel
bars with sleeve/ tie bars wherever required, laying at site, spreading and
compacting mechanically by using needle and surface vibrators, levelling
187 16.43 to required slope/ camber, finishing with required texture, including steel -
form work with sturdy M.S. channel sections, curing, making provision for
contraction/ expansion, construction & longitudinal joints (10 mm wide x
50 mm deep) by groove cutting machine, providing and filling joints with
approved joint filler and sealants, complete all as per direction of Engineer
in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to
be paid separately).
Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less
cement used as per design mix is payable/ recoverable separately.
16.43.1 Cement concrete prepared with batch mixing machine cum 127.43 127.43 10529.35 13,41,702.42
Total of sub-head (Road & Other Works) 22,45,476.58 - - - - - - 22,45,476.58
21 Digitally signed by NIRAJ
Name of Name of work : Proposed Construction of Institute of Chartered Accountants of India At
Project:- District- Gwalior(M.P.)
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICAI BUILDING
S.No. of Component :- D
Name of Component :- FIRE FIGHTING
Abstract Of Cost
S. No. DSR Description Unit Quantity Rate (In Rs) Amount (In Rs)
23.0 E&M 2025 PIPING & VALVES
1 Providing, laying, testing & commissioning of 'C' class heavy
duty MS pipe conforming to IS 3589/IS 1239 including Welding,
fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc.
and fixing the pipe on the wall/ceiling with suitable
clamp/support frame and painting with two or more coats of
synthetic enamel paint of required shade complete as required :
2 Providing, installation, testing and commissioning of non-return
27.14 valve of following sizes confirming to IS:5312 complete with -
rubber gasket, GI bolts, nuts,washers etc.as required :
3 Supplying and fixing single headed internal hydrant valve
with instantaneous Gunmetal/Stainless Steel coupling of 63
27.9 mm dia with cast iron wheel ISI marked conforming to IS -
5290 (Type -A) with blank Gunmetal/Stainless Steel cap and
chain as required :
27.9.1 Single headed Gunmetal set 2 8,208.00 16,416.00
4 Supplying, fixing, testing and commissioning of butterfly valve
of PN 1.6 rating with bronze/gunmetal seat duly ISI marked
complete with nuts, bolts, washers, gaskets conforming to IS
13095 of following sizes as required :
6 Supplying, fixing, testing & commissioning of double
flanged sluice valve of rating PN 1.6 with non rising
27.12 spindle, bronze/gun metal seat, ISI marked complete with -
nuts, bolts, washers, gaskets and conforming to IS 780 of
following sizes as required :
7 Providing, installation, testing and commissioning of
stainless steel Y-strainer fabricated out of 1.6 mm thick
stainless steel, Grade 304, sheet with 3 mm dia holes with
stainless steel flange.
S. No. DSR Description Unit Quantity Rate (In Rs) Amount (In Rs)
8 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe
with 63 mm dia male and female couplings duly bound with
GI wire, rivets etc. conforming to IS 636 (type-A) as required :
FIRE HYDRANT ACCESSORIES -
Supplying and fixing first-aid Hose Reel with MS construction
spray painted in post office red, conforming to IS 884 complete
with the following as required. 20 mm nominal internal dia water
hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve &
M.S. Pipe and socket.
Supplying and fixing of fire brigade connection of cast iron body
with gun metal male instantaneous inlet couplings complete
10 18.19 with cap and chain as reqd. for suitable dia MS pipe connection -
conforming to IS 904 as required:
2 way-100 mm dia M.S. Pipe
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick
MS sheet, 1200 mm in height with air release valve on top and
flanged connection to riser, drain arrangement with 25 mm
dia gun metal wheel valve with required accessories,
pressure gauge and painting with synthetic enamel paint of
approved shade as required.
Providing, fixing, testing & commissioning of 15mm dia
12 18.21 quartzoid bulb type sprinklers of rating 68 degree centigrade -
with required accessories :
18.21.1 Pendent Sprinkler Each 78 599.00 46,722.00
18.21.2 Upright Sprinkler Each 70 599.00 41,930.00
Providing & fixing of pressure switch in M.S. pipe line
including connection etc. as required.
Providing & fixing flow switch in following sizes M.S. pipe
including connection etc as required.
Providing, fixing, testing & commissioning of installation
control valve of cast iron body, brass/bronze working parts
comprising of water motor alarm, bronze seat clapper,
clapper arm and hydraulically driven mechanical gong bell to
15 18.24 sound continuous alarm when the wet riser/sprinkler system -
activates, pressure gauges, emergency releases, strainer,
pressure switch, cock valve complete with drain valve and
bypass, test control box, ball valves, MS pipe of required size,
flanges, orifice plate, gasket etc of follwing sizes as required
FIRE EXTINGUISHERS & MISC. ITEMS -
16 Providing and fixing 150 mm dial diameter size Pressure gauge Nos
(0-15 Kg/Cm2) complete with shut off valve duly calibrated
NSR- 24 before installation complete as required & as per enclosed 2 730.00 1,460.00
S. No. DSR Description Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and fixing Carbon-di-oxide fire extinguishers
consisting of welded M.S cylindrical body, squeeze lever
discharge valve fitted with internal discharge tube, 30cms long
high pressure discharge hose, discharge nozzle, suspension
bracket, confirming to IS : 15683 finished externally with red
enamel paint and fixed to wall with brackets with rawl
plug/dash fasteners complete with internal charge. Capacity 4.5
kg. ISI Marked.( Contractor should submit test certificate form
manufacturer along with serial number of every extinguishers
Providing and fixing (ABC Dry Chemical Powder ) type Fire
Extinguisher of Capacity 6 kg Confirms to IS 15683, bearing ISI
mark complete with brass forged squeeze grip type valve fitted
with pressure gauge , pressurize with dry Nitrogen gas filled,
with discharge nozzle with wall mounting bracket (rubber
gripped) complete with internal charges. ( Contractor should
submit test certificate form manufacturer along with serial
number of every extinguishers supplied.)
Providing and fixing water Carbon-di-oxide (ISI marked)
extinguishers including all accessories as per IS specification
19 NSR- 27 with wall bracket with rawl plug complete as reqd.( Contractor Nos 6 3,869.00 23,214.00
should submit test certificate form manufacturer along with
serial number of every extinguishers supplied.)
Capacity 9 Litres
TOATAL DSR ITEMS 12,59,726.00
TOTAL NON DSR ITEMS 89,198.00
TOTAL DSR + NON DSR ITEMS 13,48,924.00
Name of PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA AT,
Project:- DISTRICT- GWALIOR (M.P.)
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICAI BUILDING
S.No. of Component :- D
Name of Component :- INTERNAL ELECTRIFICATION
Abstract Of Cost
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
Point wiring in PVC conduit, with modular type switch :-
1.00 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point
with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor
single core cable in surface/ recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing
the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper
conductor single core cable etc. as required.
2.00 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR Point
PVC insulated copper conductor single core cable in surface /
recessed medium class PVC conduit, 2way modular switch,
modular plate, suitable GI box and earthing the point with 1.5
sq.mm FRLS/HFFR PVC insulated copper conductor single core
cable etc. as required.
Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :- -
3.00 1.12 Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC Metre
insulated copper conductor single core cable in surface/ recessed
medium class PVC conduit along with 1 No. 4 sq. mm 260 373.00 96,980.00
FRLS/HFFR PVC insulated copper conductor single core cable
for loop earthing as required.
Power plug wiring in PVC conduit (4 x 4 Sq.Mm.) :- -
4.00 1.13 Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC Metre
insulated copper conductor single core cable in surface/ recessed
medium class PVC conduit along with 2 Nos. 4 sq. mm 155 587.00 90,985.00
FRLS/HFFR PVC insulated copper conductor single core cable
for loop earthing as required.
Circuit / Sub main wiring in PVC conduit :- -
5.00 1.14 Wiring for circuit/ submain wiring along with earth wire with the
following sizes of FRLS/HFFR PVC insulated copper conductor,
single core cable in surface/ recessed medium class PVC conduit
6.00 1.17 Supplying and drawing following sizes of FRLS/HFFR PVC
insulated copper conductor, single core cable in the existing -
surface/ recessed steel/ PVC conduit as required.
S/F light plug point Modular Type Accessories :- -
7.00 1.31 Supplying and fixing suitable size GI box with modular plate and Each
cover in front on surface or in recess, including providing and
fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular
switch, connections etc. as required.
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
S/F power plug point modular Type Accessories :- -
8.00 1.32 Supplying and fixing suitable size GI box with modular plate and Each
cover in front on surface or in recess, including providing and
fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A
modular switch, connections etc. as required.
9.00 1.56 Supplying and fixing suitable size GI box with modular plate and Each
cover in front on surface or in recess, including providing and
fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A 46 757.00 34,822.00
modular switch, connections etc. as required. (For light plugs to
be used in non residential buildings).
Distribution Boards & MCB'S
10.00 2.2 Providing and fixing following rating and breaking capacity and
pole MCCB with thermomagnetic release and terminal spreaders
in existing cubicle panel board including drilling holes in cubicle
panel, making connections, Ics=100% Icu and Operational
Voltage 690V etc. as required.
11.00 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"
curve, miniature circuit breaker suitable for inductive load of
following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
12.00 2.11 Supplying and fixing single pole blanking plate in the existing Each
MCB DB complete etc. as required.
13.00 2.4 Supplying and fixing following way, horizontal type three pole
and neutral, sheet steel, MCB distribution board, 415 V, on
surface/ recess, complete with tinned copper bus bar, neutral bus
bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without
MCB/RCCB/Isolator).
14.00 2.3 Supplying and fixing following way, single pole and neutral,
sheet steel, MCB distribution board, 240 V, on surface/ recess,
complete with tinned copper bus bar, neutral bus bar, earth bar, -
din bar, interconnections, powder painted including earthing etc.
as required. (But without MCB/RCCB/Isolator)
2.3.1 6 way , Double door Each 1 2390.00 2,390.00
2.3.2 8 way , Double door Each 1 2773.00 2,773.00
S/F DP Isolator -
15.00 2.12 Supplying and fixing following rating, double pole, 240 V,
isolator in the existing MCB DB complete with connections, -
testing and commissioning etc. as required.
S/F 4P Isolator -
16.00 2.13 Supplying and fixing following rating, four pole, 415 V, isolator
in the existing MCB DB complete with connections, testing and -
commissioning etc. as required.
S/F DP (RCCB) -
17.00 2.14 Supplying and fixing following rating, double pole, (single phase
and neutral), 240 V, residual current circuit breaker (RCCB),
having a sensitivity current 30 mA in the existing MCB DB -
complete with connections, testing and commissioning etc. as
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
18.00 2.15 Supplying and fixing following rating, four pole, (three phase and
neutral), 415 volts, residual current circuit breaker (RCCB),
having a sensitivity current 30 mA in the existing MCB DB -
complete with connections, testing and commissioning etc. as
19.00 2.5 Supplying and fixing of following ways surface/ recess
mounting, vertical type, 415 V, TPN MCB distribution board of
sheet steel, dust protected, duly powder painted, inclusive of 200
A tinned copper bus bar, common neutral link, earth bar, din bar -
for mounting MCBs (but without MCBs and incomer ) as
required . (Note : Vertical type MCB TPDB is normally used
where 3 phase outlets are required.)
20.00 2.24 Supplying and fixing Cable End Box (Loose Wire Box) suitable
for following triple pole and neutral, sheet steel, MCB
distribution board, 415 Volts, on surface/ recess, complete with
testing and commissioning etc.as required.
2.24.2 For 6 way, Double door TPN MCBDB Each 2 1223.00 2,446.00
2.24.3 For 8 way, Double door TPN MCBDB Each 2 1448.00 2,896.00
S/F Modular Boxes, Base & Cover Plate :- -
21.00 1.27 Supplying and fixing following size/ modules, GI box along with
modular base & cover plate for modular switches in recess etc. as -
S/F Modular Type Switch / Socket :- - -
22.00 1.24 Supplying and fixing following modular switch/ socket on the
existing modular plate & switch box including connections but - -
excluding modular plate etc. as required.
1.24.6 Telephone Socket outlet. Each 9 168.00 1,512.00
1.24.7 TV Antenna socket outlet. Each 3 168.00 504.00
23.00 1.21 Supplying and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including cutting
the wall and making good the same in case of recessed conduit as
24.00 1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm Metre
solid copper conductor PE insulated, shielded with fine tinned
copper braid and protected with PVC sheath in the existing
surface/ recessed steel/ PVC conduit as required.
Erection Of Lighting Fixtures And Fans - -
25.00 1.41 Installation, Testing and Commissioning of pre-wired, fluorescent Each
fitting / compact fluorescent/ LED fitting of all types, complete
with all accessories and tube/lamp etc. directly on ceiling/ wall,
including connections with 1.5 sq. mm FRLS/HFFR PVC
insulated, copper conductor, single core cable and earthing etc. as
26.00 1.45 Installation, Testing and Commissioning of ceiling fan, including Each
wiring the down rods of standard length (upto 30 cm) with 1.5
sq. mm FRLS/HFFR PVC insulated, copper conductor, single 79 332.00 26,228.00
core cable, including providing and fixing phenolic laminated
sheet cover on the fan box etc. as required.
27.00 1.50 Installation, Testing and Commissioning of exhaust fan in the
existing opening, including making good the damage, connection, -
testing, commissioning etc. as required.
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
S/F modular type electronic fan regulator: -
28.00 1.25 Supplying and fixing two module stepped type electronic fan Each
regulator on the existing modular plate switch box including 79 402.00 31,758.00
connections but excluding modular plate etc. as required.
Fixing Louvers / Shutters for Exhaust Fan: -
29.00 1.51 Extra for Fixing the Louvers/ Shutters Complete with Frame for a Each
Exhaust Fan of all sizes.
Extra Down GI Pipe 15mm Dia: -
30.00 1.47 Supplying and Fixing Extra Down Rod of 10 cm Length G.I. Each
pipe, 15 mm dia, heavy gauge including painting etc. as required.
(Note : More than 5 cm length shall be rounded to the nearest 10
cm and 5 cm or less shall be ignored).
10 LT Cable Laying -
31.00 10.1 Laying of one number PVC insulated and PVC sheathed / XLPE - -
power cable of 1.1 KV grade of following size direct in ground
including excavation, sand cushioning, protective covering and
refilling the trench etc as required.
32.00 10.2 Laying of one number additional PVC insulated and PVC -
sheathed / XLPE power cable of 1.1 KV grade of following size
direct in ground in the same trench in one tier horizontal
formation including excavation, sand cushioning, protective
covering and refilling the trench etc as required.
10.2.2 Above 35 sq. mm and upto 95 sq. mm Metre 200 335.00 67,000.00
33 10.5 Laying of one number PVC insulated and PVC sheathed / XLPE -
power cable of 1.1 KV grade of following size in the existing
RCC/ HUME/ METAL pipe as required.
10.5.3 Above 95 sq. mm and upto 185 sq. mm Metre 330 97.00 32,010.00
11 MV CABLE JOINTING & END TERMINATION - -
34.00 11.1 Supplying and making end termination with brass compression - -
gland and aluminium lugs for following size of PVC insulated
and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade as required.
DSR 5 Earthing -
35.00 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick Set
including accessories, and providing masonry enclosure with
cover plate having locking arrangement and watering pipe of 2.7
Meter long etc. with charcoal/ coke and salt as required.
36 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm Set
thick including accessories, and providing masonry enclosure
with cover plate having locking arrangement and watering pipe of
2.7 Meter long etc. with charcoal/ coke and salt as required.
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
37 5.2 Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia SET
including accessories, and providing masonry enclosure with
cover plate having locking arrangement and watering pipe etc.
with charcoal/ coke and salt as required.
38 5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in Metre
recess for connections etc. as required.
39 5.18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess Metre
for loop earthing along with existing surface/ recessed conduit/ 80 50.00 4,000.00
submain wiring/ cable as required.
40.00 5.14 Providing and fixing 25 mm X 5 mm copper strip on surface or Metre
in recess for connections etc. as required.
41 5.12 Providing and laying earth connection from earth electrode with 6 Metre
SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode
including connection with G.I. thimble excavation and re-filling
LIGHTNING CONDUCTOR
43.00 6.1 Providing and fixing of lightning conductor finial, made of 25 Each
mm dia 300 mm long, G.I. tube, having single prong at top, with
85 mm dia 6 mm thick G.I. base plate including holes etc.
complete as required.
44.00 6.6 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet Mtrs.
or surface of wall for lightning conductor complete as 250 148.00 37,000.00
required.(For horizontal run)
45.00 6.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet Mtrs.
or surface of wall for lightning conductor complete as 80 238.00 19,040.00
required.(For vertical run)
46.00 6.3 Jointing copper / G.I. tape (with another copper/ G I tape, base of Each
the finial or any other metallic object) by riveting / nut bolting/ 40 139.00 5,560.00
sweating and soldering etc as required.
47.00 6.1 Providing and fixing testing joint, made of 20 mm X 3 mm thick Each
G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck 1 140.00 140.00
nuts and spring washers etc. complete as required.
49.00 NSR-28 Lightening Arrester System
Supply, Installation, Testing & Commissioning of Lightening Each
Arrester HT-12 kV expulsion type complete with all Fitting
transission class discharge capacity 10 kA complete all as as
50.00 Supply, fixing, testing & commissioning wall/floor mounted
LT panel primer coated with powder coated paint &
provided with required gasket for dust/vermin proof with
degree of protection IP42 suitable for 415Volt 3 phase, 50
Hz, 4 wire system fabricated out of CRCA sheet upto 2
mm thick (1.6 mm for doors) duly compartmentalized for
incomer, bus section, outgoings, cable alleys & CT, PT
Ampere Metre, Volt Metre, selector switches, frequency
Metre, phase indicating lamp, Energy Metre complete
including cost of busbar supports, detachable cable gland
plates, 2 earthing terminals, internal wiring & fixing of
separately supplied MCBs, MCCBs, ACB, panel mounted
changeover switch/SFUs, etc. as required but excluding
cost of busbar strips, Ampere Metre, Volt Metre, selector
switch as per approved design & specification
51 Supply and fixing of LT panel accessories of approved
make in existing LT panel including connections etc. as
required as per specification.
NSR-29 Digital Ampere Metre with CTs with selector switch P.SET 2 3443.00 6886.00
NSR-30 Digital Volt Metre with selector switch & HRC fuse P.SET 2 3884.00 7768.00
NSR-31 Frequency Metre Each 2 2326.00 4652.00
NSR-32 Aluminium bus bar strips with PVC sleeves Kg. 85.0 460.00 39100.00
NSR-33 LED lamp indicator Each 6 414.00 2484.00
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
52.00 Supplying of Following Sizes of 1.1 kV Grade Multicore
Aluminium Conductor XLPE Power Cable Insulated armoured
cable conforming to IS:7098 (Part - I) or as per Relevant IS Code
complete with all Amendments etc and should be NABL
certified as required.
NSR-34 3.5 C X 300 Sq.mm Al. XLPE arm. Metre 150 2,555.00 3,83,250.00
NSR-35 3.5 C X 185 Sq.mm Al. XLPE arm. Metre 40 1,628.00 65,120.00
NSR-36 3.5 C X 150 Sq.mm Al. XLPE arm. Metre 60 1,288.00 77,280.00
NSR-37 3.5 C X 120 Sq.mm Al. XLPE arm. Metre 80 1,097.00 87,760.00
NSR-38 3.5 C X 95 Sq.mm Al. XLPE arm. Metre 80 893.00 71,440.00
NSR-39 3.5 C X 70 Sq.mm Al. XLPE arm. Metre 105 714.00 74,970.00
NSR-40 3.5 C X 50 Sq.mm Al. XLPE arm. Metre 60 528.00 31,680.00
NSR-41 3.5 C X 35 Sq.mm Al. XLPE arm. Metre 60 395.00 23,700.00
NSR-42 2 C X 16 Sq.mm Al. XLPE arm. Metre 149 182.00 27,118.00
NSR-43 2 C X 10 Sq.mm Al. XLPE arm. Metre 150 179.00 26,850.00
53.00 NSR-44 Supply, Installation, Testing and Commissioning of
Electrical Napkin Incinerator Wall mounted factory
fabricated with CRCA sheet steel of 1.2mm thickness duly
powder coated suitable for 230V 50Hz AC Supply with
auto cut-off feature having insulation of thermal ceramic
sheet with glass wool of 4-5mm thick with MCB protection
& aprox.2 meter flexible flue gas pipe with clamp.
Sanitary Napkin Incinerator( Capacity 50 per Day) Each 4 62,639.00 2,50,556.00
Internal Lighting Fixtures & Fans
54.00 NSR-45 Supply and fixing of recessed mounting type Led light
fixture, LED of 1 to 3 Watt each assembled on single
MCPCB, having color temp upto 6500K & having 50000
burning hrs life with minimum @ L 70, system lumen
output should be minimum with efficacy>100 lm/Watt. LED
driver PF> 0.95, THD < 20% & surge protection 4KV. The
colour rendering index of LED light should be more than
70. Housing made of CRCA powder coated frame with
glare free diffused polycarbonate cover. Submission LM 79-
08/IS16106 (2012), IEC60598, IEC61347i/c connection
wire, testing etc. to complete the job.
LED luminiare 2' X 2', 36Watt, color temp 3000-6500k as Each
55.00 NSR-46 Supply of 20 Watt LED light Wall Mounted BRACKET light Each
fitting Sutaible for 220 volts Single Phase A C Supply complete 2 864.00 1,728.00
with all accessories as required.
56.00 NSR-47 Supplying and fixing brass batten/ angle holder including Each
20 w LED Lamp, connection etc. as required.
57.00 NSR-48 Supply and fixing Led tube rod comprising of LED tube Each
with non-integral/integral driver, upto 6500K color temp
having 40000 burning hrs life with minimum @ L 70,
system lumen output should be minimum with system
efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%.
The colour rendering index of LED light should be more 21 1,134.00 23,814.00
than 70. Submission LM 79-08/IS16106 (2012), IEC60598,
IEC61347i/c connection wire, testing etc. to complete the
job. Tube light
LED 1 X 18Watt, Integral i/c batten aluminium body, PC
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
Supply and fixing recessed mounting LED down lighter, LED of
1 to 3 Watt each assembled on single MCPCB, having color
temp upto 6500K & having 50000 burning hrs. life with
minimum @ L 70, system lumen output should be minimum with
efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% &
surge protection 4KV. The colour rendering index of
LED light should be more than 70. Housing made
of pressure die cast aluminium/CRCA powder
coated frame with glare free diffused
polycarbonate cover. Submission LM 79-
connection wire, testing etc. to complete the job..
NSR-49 7/8/10 Watt, color temp 3000-6500k as required. Each 5 1,234.00 6,170.00
NSR-50 18/20Watt, color temp 3000-6500k as required. Each 29 2,675.00 77,575.00
58.00 NSR-51 Supplying and fixing of Bulk Head with 10 Watt LED lamp Each
fitting Sutaible for 230 volts Single Phase A C Supply complete 4 1,300.00 5,200.00
with all accessories as required.
SUPPLY FANS & EXHAUST FANS
59.00 NSR-52 Supplying, erection and testing of approved make electric
Ceiling fan of double ball bearing complete with standard
down rod, canopy, hanging shackle, Aluminium blades,
without regulator, A.C. 230-250 volts including connections
with all necessary material complete of approved as
required confirming to IS :374/2019 with upto date
amendments.Ceiling Fan (ISI marked)-1200 mm Sweep,
with minimum air delivery 210 m³/min and service value ≥
4.00 as per BEE..
60.00 NSR-53 Supply of following sweep heavy duty metal body exhaust
fan/wall fan/ fresh air ( ventilating ) plastic body fan with guard
suitable operation on single phase 230 V, 50Hz. AC Supply, with
lowers / shutters in the existing opening. (Crompton - Trans Air
300/200mm/Approved Equivalent in Usha/Havells/Bajaj)
(a) 200 mm sweep 900 RPM ( in plastic body)Ventilating fan fan Nos 2 1,116.00 2,232.00
(c) 300 mm sweep 900 RPM ( In metal body) exhaust fan Nos 4 3,103.00 12,412.00
(d) 450 mm sweep 900 RPM ( In metal body) exhaust fan Nos 1 4,892.00 4,892.00
e) 400 mm sweep oscillating type four speed wall mounting fan Nos.
61.00 NSR-54 Supplying and fixing following rating, Single/ double/ three pole,
230/ 415 volts, MCB "C" curve in the existing MCB DB
complete with connections, testing and commissioning etc. as
63 amps FP MCB Each 1 1580.00 1,580.00
Pumps (Non Scheduled Items)
62.00 NSR-55 Borewell Submersible Pump Set 1 59,261.00 59,261.00
Supplying & Installation of suitable borewell submersible pump
set coupled with 6" motor and complete with lowering in existing
borewell with the help of chain pulley block including supplying
and fixing motor starter suitable for the selected pump complete
as required.( Note : The suction/delievery pipe lines are not
included in this item )
Flow Rate : 350 to 400 LPM
min. Head : 60 M
Min. Motor HP : 7.5 H.P.
63.00 NSR-56 Supplying and Fixing of PVC covered 6 mm dia flexible steel Metre 200 60.00 12,000.00
rope for handling/protecting the submersible Pump set including
U-lock arrangement etc. complete as required.
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
64.00 NSR-57 Supplying and Fixing of suitable size of MS clamp set suitable Each 32 790.00 25,280.00
for holding submersible pump & 40 mm dia pipe assembly
lowered in bore well including suitable drilled hole and nut bolts
etc. complete as required.
65.00 NSR-58 Supplying and Fixing of following size of PVC insulated PVC
sheathed Copper conductor flat submersible cable including
fixing the cable with nylon tie along with GI pipes in existing
borewell, connection with submersible pump cable with the help
of water proof jointing kit provided with the pump, complete as
S/Fixing of 8 " dia MS cover with locking arrangement i/c 24 1,115.00 26,760.00
drilling hole and s/f nut bolts etc. complete as reqd.
66.00 Openwell Submersible Monobloc Pump Set Set 1 54,792.00 54,792.00
NSR-59 S.I.T.C. of 7.5/5.5 (H.P./Kw) Openwell Submersible Monobloc
Pump Set comprising of Electrical Driven inline pumping with
all accessories as per manufacturer's design. such as C.I. Base,
S.S /bronze impeller, shaft, mechanical seal, S.S. Shaft directly
coupled to motor suitable for operation on 400/440 volts, 3 phase
50c/s A.C.Supply complete in the existing G.I.Pipelines
fittingsi/c s/fixing motor starter suitable for this pump set i/c
connections testing, commissing etc as reqd. ( Note : The
suction/delievery pipe lines are not included in this item )
Flow Rate : 4.5 to 5.0 LPS
Min. Head : 50 M
Min. Motor HP : 7.5 H.P. (Each)
1 Supply, installation, testing & commissioning of Water
Cooler with Eco Friendly Refrigerant, IN-SITU PUF
Insulation, Anti-corrosive Pre-coated Body with storage of
required capacity
WATER COOLER 150 LITRE Each 2 55,945.00 111890.00
2 NSR-60 Supply, installation, testing & commissioning of 50 LPH
RO Plant with sediment filtration having minimum
purifying capacity of 50LPH per hour. Suitable for reducing
hardness, TDS, heavy metal contaminants, and
pathogenic micro organism, operating input voltage 230V
2 NSR-61 Supply, installation, testing & commissioning of
L.E.D. Television (4K L.E.D. Display O.S.
Webos /Android or equivalent, minimum 50 Hz
refresh rate Min. 20 W speaker, Wifi/bluetooth
enabled, minimum 2 HDMI & 1USB Port, i/c
remote and wall/table top accessories)
TOATAL DSR ITEMS 37,67,862.00
TOTAL NON DSR ITEMS 44,04,908.00
TOTAL DSR + NON DSR ITEMS 81,72,770.00
Name of PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA AT,
Project:- DISTRICT- GWALIOR (M.P.)
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICAI BUILDING
S.No. of Component :- D
Name of Component :- CCTV internal
Abstract Of Cost
S. No. E&M 2025 Description Unit Quantity Rate (In Rs) Amount (In Rs)
1.00 39.18 Supplying, drawing, Testing and commissioning of Cat6A UTP
4 pair, 23 AWG solid copper cable in existing conduit/ on
surface, U/FTP, LSZH, Non Plenum, Horizontal (solid) Cable
suitable for high speed data networking application supporting
upto 10Gbps over a 100 meter channel. The 4 Unshielded
Twisted Pairs (UTP) cable with color coded insulation for easy
indentification should have FLAME PROPERTIES i.e.
Flammability Test - IEC 60332-1, Smoke Density - IEC 61034,
LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC
11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS.
The outer Cable Diameter should be 7.5 + 2 mm. Cable should
have been tested and verified by UL/ ETL etc. complete as
2.00 1.21 Supplying and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of recessed
conduit as required.
40.1 Supplying Installation Testing and Commissioning of 2 MP IP
IR Dome Camera having following specifications, type of lens
and features etc :- 1) Signal System: PAL/NTSC, Signal to
Noise Ratio: >50 dB, Camera should display Camera title, Date
& Time in live & recorded video 2)Image Sensor: 1/2.8" or
better progressive Scan CMOS to get color image even at night
condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON,
0 lux with IR or better) True Day & Night High Performance
Mechanical IR cut filter with auto switch, Integrated IR Source
(Auto, Manual)- Inbuilt IR LED's with effective distance upto
50 meter or better and 30 meter for colour view in night,
Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain
Control , White Balance- Auto, Back Light Compensation,
Multi zone Privacy Masking, HLC, Digital Watermarking. 3)
Compression (Minimum):-Video:- H.265 or better, H.264H,
H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4)
Wide Dynamic Range:- WDR (120db or more) 5) Digital Noise
Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame
Rates :- Triple streaming , configurable ×1080)@25/30
720P@25/30 fps). (Main fps,Sub stream: streams 2MP (1920
minimum: 7) Image Setting: Rotate Mode, saturation,
brightness, contrast, sharpness adjustable through client
software or web browser, Edge Analytics: Tripwire, Intrusion,
Motion Detection 8) Cyber Security: AES 256-bit Encryption,
Configuration encryption, trusted execution, Digest, security
logs, account lockout, syslog, video encryption, IP/MAC
filtering, HTTPS, trusted upgrade, trusted boot. 9) Onboard
Storage: Camera should support built-in Micro
SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied
with minimum 128GB memory Card
S. No. E&M 2025 Description Unit Quantity Rate (In Rs) Amount (In Rs)
10) Recording Management: Format SD, overwrite, storage
management, video to NAS device 11) Alarm Trigger :
Motion/tampering detection; audio detection; network
disconnection detection; IP conflict detection; memory card
state detection; memory space detection 12)Network Protocol:
SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS,
SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP,
RTSPS, unicast 13) System Capability: ONVIF, Camera shall
support open source VMS 14) Ethernet: 1 RJ 45 10/100
Ethernet port 15) Audio : It should support 1 x Built-In Mic and
1/1 Alarm In/ Out for External Mic. and Speakers as per site
requirement. 16) Power Input: The camera should support
simultaneous dual power input—12 VDC (via power adapter)
and PoE (802.3af)—to ensure continuous operation in the event
of a failure in one power source. 17) Power Requirement:
12VDC/24 VAC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:-
IP67 weather proof, IK10, Metallic body 19) Operating
Condition:- Ambient Temperature:- (
)05°C to 50°C, humidity 95% (max) (non-condensing)
20) IR life: 40000 hours or higher
21) Video Bit rate: 32 KBPS - 8 MBPS or better
22) Standards: BIS with ER, STQC Certified, CE, FCC
to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens. Each 10 19,796.00 1,97,960.00
40.10 Supplying Installation Testing and Commissioning of ollowing
Channel Network Video Recorder (NVR) with camera licenses
to record for all channels having specifications and features etc
as mentioned below : 1) Network Video Recorder Embedded/
Installed OS (Linux) along with Camera Licenses for number of
channels of NVR to record per NVR and to provide a live view,
storage and simultaneously Multi-channel playback of all IP, IR
camera or more and must be ONVIF with minimum support of
256Mbps incoming Bandwidth. 2) NVR should support H.265
or better, H.264,
MJPEG, MPEG4 support
3) Must support 1 channel Input, 1 channel Output,
RCA for Two-way Talk
4) Intelligent auto power on when power resumes after
5) Storage: It should support minimum 2 SATA Slots
with 20TB capacity/ Slot.
6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps
Ethernet Ports, 1x RS485, 1x RS232
7) Backup Interface : Its should have 2 Nosx USB port
(1x USB3.0, 1xUSB2.0)
8) Video Output Ports: 1x HDMI and 1 VGA
9) Alarm Ports: It should have 4/1 Ch In/ Out ports to
connect various type of external sensors and output
devices like hooter/ Siren etc.
10) Email & SMS Altert options: Option for SMS/ Email
Alerts to minimum 5 designated mobile number for
power failure, HDD failure, vandalism, tempring,
network disconnection and panic
11) Web & Mobile Application: Web, Mobile app ( For
S. No. E&M 2025 Description Unit Quantity Rate (In Rs) Amount (In Rs)
19) The OEM must provide its own DDNS server hosted in
India, eliminating the need for a public IP address for remote
monitoring over the Internet. 20) Must support Resolution:
1280×1024,1280×720, 21) Must support recording resolution
upto 32MP 22) Must support Continuous, Alarm, Motion,
Instant, Panic Recording Mode 23) When alarm recording is
enabled and an event occurs, you can click the alarm icon on
monitoring page to view the alert details. The snapshot function
is supported on monitoring and playback page 24) The Network
Video Recorder (NVR) shall be configured to send email
whenever a system message is created or an alarm event occurs.
The email server shall be a valid SMTP server. Each recipient
email address shall be configured to receive any combination of
critical, warning, or informational messages or alarm
notifications. When an alarm occurs, the email message includes
the NVR name, time of alarm and a list of camera that is
configured to record upon alarm 25) It should support Network
Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP,
NTP, UPnP, Multi IP Setting. Convert multiple recording files
to one avi/MP4 file. 26) General AI Based Search: Search
Pictures by channel, time, event type, target classification (Fall
Detection, People Approach Detection, People No. Exception
Detection, People Staying Detection, Violence Detection. 27)
Alarm Notifications based on: Motion detection, video
tampering, video loss, scene changing, PIR alarm, Camera
external alarm, Face detection, face recognition, perimeter
protection (intrusion and tripwire), ANPR, people counting,
stereo analysis, crowd distribution, heat map, Disk Full, Storage
Error, IP Conflict
29) Built-In and Intelligence:
Artificial abnormal behavior of fan 28)
NVR should haveAlarm
:-- 2 Channel face detection and recognition, - Minimum 4
Channel perimeter protection, - Minimum 8 Channel Smart
Motion Detection 30) Face Recognition Database Capacity: It
should support total Blacklist and Whitelist capacity of
Minimum 20,000 Faces or more with Face Detection speed of
12 face images/sec. 31) Face & Human Attributes Search:
Search Pictures/ Video by Gender, age group, glasses,
expressions, face mask, beard, Top color, top type, hat, bag, age,
gender and umbrella. 32) ANPR Capability: It should support
ANPR Camera with License plate, plate color, vehicle body,
vehicle model, vehicle logo, calling, seatbelt, vehicle registration
location etc vehicle attributes. 33) Alarm Notifications based on:
Motion detection, video tampering, video loss, scene changing,
PIR alarm, Camera external alarm, Face detection, face
recognition, perimeter protection (intrusion and tripwire),
ANPR, people counting, stereo analysis, crowd distribution,
heat map, Disk Full, Storage Error, IP Conflict and abnormal
behavior of fan, cybersecurity exception 34) Alarm Notification
should be linked with Recording, snapshots, Camera external
alarm output, buzzer, logs, presets and email. 35) General AI
Based Search: Search Pictures by channel, time, event type,
target classification (Fall Detection, People Approach Detection,
People No. Exception Detection, People Staying Detection,
Violence Detection. 36) Smart playback function: Should
support smart search for the selected area in the video and smart
playback to improve the playback efficiency 37) VCA (Video
Content Analytic): Should support multiple video contented
analytics based on camera
5.00 40.10.2 16 Channel Network Video Recorder (NVR) having display
split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16
S. No. E&M 2025 Description Unit Quantity Rate (In Rs) Amount (In Rs)
40.12 Supplying, Installation, Testing and Commissioning following
capacity Serveillance grade Hard Disk with upto 256MB/s
Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch
form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE,
FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV,
UL Certifications.
7.00 NSR 65 Supply, Installation, testing and commissioning of 16 port POE
Data switch connections as per specifications complete as Each 1 19,133.00 19,133.00
required. (Cisco , Netgear , Dlink or Equivalant)
8.00 NSR 66 S.I.T.C.32" Color flat panel LED Monitor,Full HD Professional
Series 1920 x 1080 resolution, inputs. 100-230VAC/50 Hz. Each 2 23,483.00 46,966.00
TOATAL DSR ITEMS 3,23,625.00
TOTAL NON DSR ITEMS 66,099.00
TOTAL DSR + NON DSR ITEMS 3,89,724.00
Name of PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA AT,
Project:- DISTRICT- GWALIOR (M.P.)
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICAI BUILDING
S.No. of Component :- D
Name of Component :- fire alarm system
Abstract Of Cost
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
addressable fire alarm system
1 28.5.2 Supplying & laying of 2x1.5 sqmm fire alarm armoured
cable, 600/1000V rated with annealed copper conductor
having XLPE insulation, steel wire armouring &
FRLS/HFFR outer sheath complete as required.
2 28.2 INTELLIGENT FIRE ALARM SYSTEM Supplying,
installation, testing and commissioning of micro processor
based intelligent addressable main fire alarm panel,
central processing unit with the following loop modules
and capable of supporting not less than 240 devices
28.2.1 (including detectors) and minimum 120 detectors per loop
and loop length up to 2 km, network communication card,
minimum 320 character graphics/ LCD display with touch
screen or other keypad and minimum 4000 events history
log in the non volatile memory (EPROM), power supply
unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt
sealed maintenance free batteries with automatic
charger.The panel shall have facility to connect printer to
printout log and facility to have seamless integration with
analog/digital voice evacuation system (which is part of
the schedule of
work under SH: PA System) and shall be complete with
all accessories . The panel shall be compatible for IBMS
system with open protocol BACnet/ Modbus over IP
complete as per
28.2.1.2 specifications.
Two Loop Panel Each 1 250420.00 250420.00
3 28.2.3 Supplying, installation, testing & commissioning of
repeater panel with 320 character/ Touch screen LCD
display with inbuilt reset, acknowledge and silence
switches complete as required.
4 28.2.9 Supplying, installation, testing & commissioning of
intelligent addressable thermal detector with rate of rise
cum fixed temperature thermistor complete with base as
5 28.2.13 Supplying, installation, testing & commissioning of
intelligent addressable duct detector including suitable Each 60 8183.00 490980.00
Photo detector complete with base as required.
6 28.2.14 Supplying, installation, testing & commissioning of
addressable manual call point complete as required.
7 28.1.5 Supplying, installation, testing & commissioning response
indicator on surface/recess MS box having two LEDs
metallic cover complete with all connections etc. as
8 28.1.6 Supplying, installation, testing & commissioning fire alarm
sounder with facility to make announcement, mounted in
M.S. box (16 SWG) with hinged cover plate & suitable for Each 1 600.00 600.00
operation with amplifier i/c line matching transformer etc.
complete as required.
9 NSR-67 Supply, installation, testing and commissioning of
addressable control relay module with inbuilt isolators &
with flexible network structures with a maximum switching
current of 1A @ 30V DC, shall be UL/EN54 certified
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
TOATAL DSR ITEMS 9,84,502.00
TOTAL NON DSR ITEMS 29,221.00
TOTAL DSR + NON DSR ITEMS 10,13,723.00
Name of PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA AT,
Project:- DISTRICT- GWALIOR (M.P.)
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICAI BUILDING
S.No. of Component :- D
Name of Component :- PA SYSTEM
Abstract Of Cost
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
1 NSR-68 Supply and fixing of PVC insulated copper flexible
speaker wire twin FR-LSH 1100 Volts as per IS:694-1990
of approved make
(48/0.20 mm) Twin core 1.50 sq.mm. Metre 790 94.00 74260.00
NSR-69 Supply, installation, testing and commissioning of
4X125W class-D amplifier with 4 independent channels
and can provide automatic re-settable over current, Each 1 533008.00 533008.00
overload, overheating, overvoltage, under-voltage and
3 NSR-70 Mixer
Supply, installation, testing and commissioning of 8-
Channel Mixer with Low-cost, high-performance Lexicon
effects mixers. 8+2 and 12+2 channel frame sizes. Built-in
24 bit Lexicon digital effects processor. 32 FX settings
4 NSR-71 Speakers
Supply, installation, testing and commissioning of 6W
ceiling speaker with max SPL1M/1W 96dB. Frequency
response of 80Hz-20KHz with a dispersion angle of 160 Each 16 2760.00 44160.00
deg. The speaker should have tapings at 6W/3W/1.5W
(with require mounting arrangement)
5 NSR-72 Supply, installation, testing and commissioning of 20W
column speaker with max SPL1M/1W 94dB. Frequency
response of 300Hz-15KHz with a dispersion angle of 160 Each 6 45139.00 270834.00
deg. The speaker should have tapings at 20 W / 10 W / 5
W / 2.5 W (With require mounting arrangement)
6 NSR-73 Microphones
Supply, installation, testing and commissioning of
Professional Dyanamic Vocal Microphone Audio
frequency bandwidth: 70 to 20000 Hz Sensitivity: 2.6 Each 1 26328.00 26328.00
mV/Pa Electrical impedance: 600 Ohms Recommended
load impedance: 2000 Ohms Polar Pattern: Supercardioid
7 NSR-74 Supply, installation, testing and commissioning of
Wireless microphone system Microphone capsule:
Patented dynamic D5 capsule Polar pattern: Each 1 80059.00 80059.00
supercardioid Audio bandwidth: 70 – 20 000 Hz (+/- 3dB)
Dimensions: 237 x 51mm
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
8 NSR-75 Supply, installation, testing and commissioning of
Transmitter : HDMI HDBaseT-Lite Extender with PoH (4K
@ 40 mtr.) (HDBaseT Class B) extends an HDMI signal
up to 70m from the HDBaseT source using one Cat
5e/6/6a cable. Video :- Input Interfaces : 1 x HDMI Type
A Female (Black); Impedance : 100 Ω; Max. Distance : 3
m, Max. Data Rate : 10.2Gbps (3.4Gbps per lane); Max.
Pixel Clock : 340 MHz; Compliance : HDMI (3D, Deep
Color, 4K), HDCP2.2 Compatible, Consumer Electronics
Control (CEC)Audio Input : 1 x HDMI Type A Female
9 NSR-76 Supply, installation, testing and commissioning of
Receiver : HDMI HDBaseT-Lite Extender with PoH (4K @
40 mtr.) (HDBaseT Class B) extends an HDMI signal up
to 70m from the HDBaseT source using one Cat 5e/6/6a
cable. Video :- Output Interfaces : 1 x HDMI Type A
Female (Black); Impedance: 100 Ω; Max. Distance : 3 m,
Max. Data Rate : 10.2Gbps (3.4Gbps per lane); Max.
Pixel Clock : 340 MHz; Compliance : HDMI (3D, Deep
Color, 4K), HDCP2.2 Compatible, Consumer Electronics
Control (CEC), Audio Output : 1 x HDMI Type A Female
10 Conference System
11 NSR-77 Supply, installation, testing and commissioning of
Conference Delegate Unit Nominal Acoustic Input at the
microphone 85dB SPL Frequency Response 400Hz to Each 4 24479.00 97916.00
10Khz. Length of the microphone from the base of the
stem 488mm or more.
12 NSR-78 Supply, installation, testing and commissioning of
Conference Chairman unit Nominal Acoustic Input 85dB
SPL Frequency Response 400Hz to 10kHz. Length of the
microphone from the base of the stem 488mm or more.
13 NSR-79 Supply, installation, testing and commissioning of
Conference Control unit Frequency response 200 Hz to
12 kHz Input Impedance 4.7 kohm Rated output
Impedance 1 kohm Equaliser Center frequencies of filters
250Hz,2kHz and 8kHz Mic input sensitivity 1 mV (+1/-
3dB) Aux input sensitivity 100mV (+1/-3dB)
14 NSR-80 Supply, installation, testing and commissioning of
Professional Dyanamic Vocal Microphone Audio
frequency bandwidth: 70 to 20000 Hz Sensitivity: 2.6 Each 1 26328.00 26328.00
mV/Pa Electrical impedance: 600 Ohms Recommended
load impedance: 2000 Ohms Polar Pattern: Supercardioid
15 NSR-81 Supply, installation, testing and commissioning of
Professional instrumental microphone Audio frequency
bandwidth 50 - 20000 Hz Sensitivity at 1000 Hz2.5 mV/Pa
(–52 dBV re 1 V/Pa) Max. SPL for 1 % / 3 % THD147 dB Each 1 34688.00 34688.00
SPL / 156 dB SPL Electrical impedance at 1000 Hz≥ 600
Ohms Recommended load impedance≥ 2000 Ohms Polar
Pattern Cardioid
16 NSR-82 Supply, installation, testing and commissioning of
Wireless microphone system Microphone capsule:
Patented dynamic D5 capsule Polar pattern: Each 1 80058.00 80058.00
supercardioid Audio bandwidth: 70 – 20 000 Hz (+/- 3dB)
Dimensions: 237 x 51mm
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
17 NSR-83 Supply, installation, testing and commissioning of
Transmitter : HDMI HDBaseT-Lite Extender with PoH (4K
@ 40 mtr.) (HDBaseT Class B) extends an HDMI signal
up to 70m from the HDBaseT source using one Cat
5e/6/6a cable. Video :- Input Interfaces : 1 x HDMI Type
A Female (Black); Impedance : 100 Ω; Max. Distance : 3
m, Max. Data Rate : 10.2Gbps (3.4Gbps per lane); Max.
Pixel Clock : 340 MHz; Compliance : HDMI (3D, Deep
Color, 4K), HDCP2.2 Compatible, Consumer Electronics
Control (CEC)Audio Input : 1 x HDMI Type A Female
18 NSR-84 Supply, installation, testing and commissioning of
Receiver : HDMI HDBaseT-Lite Extender with PoH (4K @
40 mtr.) (HDBaseT Class B) extends an HDMI signal up
to 70m from the HDBaseT source using one Cat 5e/6/6a
cable. Video :- Output Interfaces : 1 x HDMI Type A
Female (Black); Impedance: 100 Ω; Max. Distance : 3 m,
Max. Data Rate : 10.2Gbps (3.4Gbps per lane); Max.
Pixel Clock : 340 MHz; Compliance : HDMI (3D, Deep
Color, 4K), HDCP2.2 Compatible, Consumer Electronics
Control (CEC), Audio Output : 1 x HDMI Type A Female
19 NSR-85 Supply, installation, testing and commissioning of
Interactive Panel having Resolution 3840(H) ×2160 (V),
Display Color 1.07Billon Colors, Min. Brightness
400cd/m2, LCD (with LED backlit), View Angle R/L 178
(Min.), U/D 178 (Min.), speaker output 20W × 2, HDMI
Input 2, HDMI Output 1, Multi-Media USB 4 (2 Front
Yes(LAN) / Ethernet, Touch input 02, Bluetooth BT 5.0,
WIFI 6, VGA In 1, Line Out 1, MIC 1, DP 1.2 1, Cover
Glass anti glare 9 Mohs, Touch Resolution 32768x32768,
Touch Accuracy 1mm, having Annotation Over Any
Source, Response Time <5ms, having Palm Detection,
Pen and Touch Differentiation, Touch - 20 points
(Drawing, Annotation, Painting, Eraser, Highlighter, PDF
Viewer, PPT Viewer, Browser, Movies & Image Viewer,
External Source annotation), Files like PDF or objects can
be saved in a private folder, 4 Drawing through split
screens / Export and Import of files from mails / pen-drive
or internet / Multimedia feature, Compatibility Windows
11/ Linux/Android /Chrome, OS Version ANDROID 11.0 ,
Processor A55 Quadcore 1.55Ghz, Flash 32 GB EMMC5,
RAM 4 GB DDR4 or equivalent latest software version
and specification, having accessories- User manual,
wireless key board and mouse, remote control, power
cable, touch cables, HDMI cable, Touch pens (2 stylus, 1
extendable),VESA Standard (Wall mount) / 3 Year
85/86 Inch Interactive Panel Each 1 806501.00 806501.00
20 NSR-86 Supply, installation, testing and commissioning of OPS
(Open pluggable specificatio) with Core i5 Processor, 512 Each 1 100003.00 100003.00
GB SSD, 8 GB RAM, Latest Windows.
TOATAL DSR ITEMS -
TOTAL NON DSR ITEMS 27,74,710.00
TOTAL DSR + NON DSR ITEMS 27,74,710.00
Name of PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA AT, DISTRICT- GWALIOR
Project:- (M.P.)
S.No. of Project Sub Head :- 1
S.No. of Component :- D
Name of Component :- UPS
Abstract Of Cost
DSR Amount (In
S. No. Description Unit Quantity Rate (In Rs)
Distribution Boards & MCB'S
2 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB DB -
complete with connections, testing and commissioning etc. as required.
2.10.1 Single pole Each 12 285.00 3,420.00
3 2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. Each
4 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel,
MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus
bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB/RCCB/Isolator).
2.4.3 8 Way (4 + 24), Double Door Each 0 6337.00 -
5 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing
etc. as required. (But without MCB/RCCB/Isolator)
2.3.1 6 way , Double door Each 1 2390.00
2.3.2 8 way , Double door Each 0 2773.00 -
S/F DP Isolator -
6 2.12 Supplying and fixing following rating, double pole, 240 V, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.
S/F 4P Isolator -
7 2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB
DB complete with connections, testing and commissioning etc. as required
S/F DP (RCCB) -
8 2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,
residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the
existing MCB DB complete with connections, testing and commissioning etc. as
9 2.15 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,
residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the
existing MCB DB complete with connections, testing and commissioning etc. as
11 2.24 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple
pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, -
complete with testing and commissioning etc.as required.
2.24.2 For 6 way, Double door TPN MCBDB Each 1 1223.00 1,223.00
2.24.3 For 8 way, Double door TPN MCBDB Each 0 1448.00 -
10 LT Cable Laying -
12 10.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1
KV grade of following size direct in ground including excavation, sand cushioning, - -
protective covering and refilling the trench etc as required.
10KVA Online UPS 3PH input/ 3PH output
14 26.2 Online UPS- Input supply: Three Phase, Output supply: Three Phase.
S. No. Description Unit Quantity Rate (In Rs)
Supplying, installation, Testing & Commissioning of following capacity at full load
(Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to
95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for
the replacement or addition of battery modules without shutting down the entire
system) modular Power Supply (UPS) system with N+1 modules (N denotes total
number of modules required for rated capacity). The UPS shall include a Rectifier,
inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not
be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load
(Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with
provision for manual bypass, suitable isolation transformer for additional protection
against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS
systems offered are to be of the latest technology with Digital Control Microprocessor
based for 190 DELHI SCHEDULE OF RATES (E&M)-2025 reliable operation using
Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level)
with PWM (Pulse Width Modulation). The quality of design, manufacturing and
inspection process should confirm to the relevant Inter-national standards such as
IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while
operating on battery mode and delivering quality power to the 100% non-linear loads.
Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The
required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost),
extreme power factor kit to be included to limit the input power factor (PF) to 0.99
and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1
), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor
loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-
5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of
120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1
meter distance, protections: Input Under voltage over voltage, abnormal out voltage,
battery over charging, output over current, short circuit protection, battery deep
discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic
Fully rated Inbuilt static switch at the inverter output and 100% rated Inbuilt static
switch at the static bypass line integrated in UPS module.
Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter,
PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and
display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail /
Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc.
h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time,
etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load
/ UPS Fault /Battery charging and discharging, overload, battery voltage and battery
capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault,
Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over,
Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have
QR code which should contain drawing, test report OEM manual, Geo- Tag of
manufacturing location etc
26.2.1 10KVA (Each Power module shall be < 10 KVA) each 1 2,08,893.00 2,08,893.00
13 Supplying of Following Sizes of 1.1 kV Grade Multicore Aluminium Conductor
XLPE Power Cable Insulated armoured cable conforming to IS:7098 (Part - I) or as
per Relevant IS Code complete with all Amendments etc and should be NABL
certified as required.
NSR-87 3.5 C X 25 Sq.mm Al. XLPE arm. Metre 70 319.00 22,330.00
NSR-88 2 C X 16 Sq.mm Al. XLPE arm. Metre 97 182.00 17,654.00
NSR-89 2 C X 10 Sq.mm Al. XLPE arm. Metre 90 179.00 16,110.00
15 NSR-91 Supply , installation , testing and commissioning 63A FP MCB of 10kA breaking set 3,698.00 3,698.00
Capacity in metal sheet enclosure with ON/OFF, TYB Indication lamps for Incoming 1
of UPS Complete in All Respect as Required.
TOATAL DSR ITEMS 277607.00
TOTAL NON DSR ITEMS 59792.00
TOTAL DSR + NON DSR ITEMS 337399.00
Name of Project:-
PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA AT, DISTRICT- GWALIOR (M.P.)
S.No. of Project Sub Head :- 1
S.No. of Component :- D
Name of Component :- LIFT
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
Distribution Boards & MCB'S 0.00 0.00
S/F 4P Isolator -
1 2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as Required. -
S/F DP (RCCB) -
2 2.15 Supplying and fixing following rating, Four pole, (Threee phase and neutral), 415 V, residual current circuit
breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, -
testing and commissioning etc. asrequired.
3 2.24 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following tripole pole and neutral, sheet
steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as -
2.24.1 For 4 way Double door TPN MCBDB Each 1 1177 1,177.00
DSR 10 LT Cable Laying -
4 DSR 10.1 Laying of One Number PVC Insulated And PVC Sheathed / XLPE Power Cable of 1.1 kV Grade of Following
Size Direct in Ground Including Excavation, Sand Cushioning, Protective Covering and Refilling the Trench -
etc. as required.
DSR10.1.1 Upto 35 sq. mm Metre
6 21.1 Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room
less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-
III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier
free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of
MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under
including all other equipment and accessories complete as required:-
(i) Speed-1 MPS
(ii) Floors-5 (G+4)
(iii) Travel -17 Meters (approx.)
(iv) Stops & opening- 5 stops and 5 openings
(v) Controller: A.C. variable voltage & variable
(vi) Operation: Simplex collective selective with/without lift attendant.
(vii) Total rise: About 3 mtrs. (approx) two stops only.
(vi) Automatic rescue device (ARD) complete with dry
maintenance free batteries as required.
vii) Operation: Microprocessor based single automatic
collective/duplex
collective selective with/without attendant
(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires
Car Enclosure: Stainless steel scratch proof
(Moon Rock/Honeycomb/ Hairline Finish) on all sides
and stainless steel decorative ceiling with fans (indirect
throw) and LED fitting.
(x) The car flooring should be smooth and antiskid as
approved by engineer-in-charge.
(xi) Type of doors
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
2022 (vi) Automatic rescue device (ARD) complete with dry
maintenance free batteries as required.
vii) Operation: Microprocessor based single automatic
collective/duplex
collective selective with/without attendant
(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires
Car Enclosure: Stainless steel scratch proof
(Moon Rock/Honeycomb/ Hairline Finish) on all sides
and stainless steel decorative ceiling with fans (indirect
throw) and LED fitting.
(x) The car flooring should be smooth and antiskid as
approved by engineer-in-charge.
(xi) Type of doors
(a) Car: Power operated, centre opening horizontal
announce the position of the elevator in the hoist
way as the car passes or stops at floor served by the
(xiv)Closed loop Control System, protection against
power fluctuation, self diagnostic control, Landing
doors 2 hours Fire rated, Overload detection and
protection, Overspeed Governer, Dot Matrix LED D &
P Indicators In Car & Landings, BMS Compatibility,
tamper proof infrared curtain covering almost the entire
height of the lift car door, Alarm horn, Anti Nuisance
Operation, CCTV camera system with 4 MP IP
camera, suitable NVR and HDD for 30 days storage
backup , Firemen switch, 2/3 way intercom,
Emergency Stop Switch with battery backup for fan
and light fitting for 1 hour, pit ladder.
(xv) The lift doors shall have a vision panel to enable
persons with hearing impairment to
signal for help or assistance in the event of an
(xvi)An appropriate technological support be provided
(xxxiii) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit
should be provided by the lift agency, along with the other steel structure works, foundations for
the machines etc.
(xxxiv) In the hoist way fascia plate shall be provided.
(xxxv) Permanent wiring in lift machine room and lift well with proper no. of light points, with fixtures,
exhaust fan, plug points and 3 phase 440V power supply shall be made in lift shaft by the
department, machine room or at desired level.
(xxxvi) Car top safety barricade shall be provided.
(xxxvii) ARD (automatic rescue device): Solid state inbuilt automatic rescue device (ARD)
automatically rescues passengers trapped in the lift car in between floors in the event of power
failure. Automatic operation and immediate action in the event of mains failure, capable of moving
the lift to the nearest landing, opens the automatic door of
the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and
auto changeover device on mains failure.
21.1.2 26 Passenger (1768Kg.)/Bed Lift Each 0 2348212
7 NSR-95 Add extra to item no. 44.1for machine room less (MRL) lift in place of machine room directly above
Extra cost for machine room less (4-13 Passenger) Each 1 145800.00 145800.00
8 NSR-96 Add extra to item no. 44.1 for hall lantern and arrival gong system.
Extra cost for per floor per lift Each 3 19440.00 58320.00
5 Supplying of Following Sizes of 1.1 kV Grade Multicore Aluminium Conductor XLPE Power Cable
Insulated armoured cable conforming to IS:7098 (Part - I) or as per Relevant IS Code complete with
all Amendments etc and should be NABL certified as required.
NSR-92 2 C X 16 Sq.mm Al. XLPE arm. Metre 60 182.00 10,920.00
NSR-93 2 C X 10 Sq.mm Al. XLPE arm. Metre 55.00 179.00 9,845.00
TOATAL DSR ITEMS 1708234.00
TOTAL NON DSR ITEMS 224885.00
TOTAL DSR + NON DSR ITEMS 1933119.00
PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA AT, DISTRICT- GWALIOR
Name of Project:- (M.P.)
S.No. of Project Sub Head :- 1
S.No. of Component :- D
Name of Component :- HVAC
Abstract Of Cost
S.No. DSR 2022 Item Name Description of Item Unit Quantity Rate Amount
VRV/VRF outdoor Supplying, Installation, Testing & Commissioning of Modular type
AC unit Variable Refrigerant Flow/Variable
Refrigerant Volume air cooled Outdoor units suitable for
cooling/heating having 100% hermetically sealed inverter type twin
Rotary/Scroll Compressor(s), minimum two
compressors (with individual separate PCB) for above 14HP
modules, microprocessor based Controller, top discharge type
condensing unit(s), with R-410-A Refrigerant or equivalent,
vibration Isolators with suitable foundation etc. complete as
required. To have better efficiency condenser fan shall be capable
to operate at different speed with respect to load. The unit shall
the rated capacity and in confirmation as per IS
18728:2024 and CPWD Specifications and work even at 50°C
1 31.1 ambient temperature without tripping. The system
shall be able to deliver 100% of the rated capacity upto 39
0C. The unit shall be suitable to work on 400V +/- 10%, 3
Phase, 50Hz AC power supply and BMS compatible. The
unit shall be filled with first charge of the refrigerant and
ready for use as required. The condenser should be coated
with a hydrophilic film to prevent water accumulation on the
surface of the heat exchanger, enhance water dispersion,
and reduce the risk of degradation, thereby improving
overall performance and durability. The Indian Seasonal
Energy Efficiency Ratio (ISEER) of the unit shall be as per
Energy Conservation and Sustainable Building Code
(ECSBC) 2024 as below and complete as per CPWD
specification, connections, inter connections etc. as
required. (For capacity <40 kWr ISEER 5.4, Capacity > 40
and <70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC
VRF/VRV indoor Supplying, Installation, Testing and Commissioning of
ACunit (wall following minimum capacity High wall type Indoor unit
mounted) equipped with and comfort washable synthetic media pre
filter, fan section with low noise fan/dynamically balanced
blower, multispeed motor, coil section with DX copper coil,
electronic expansion valve, outer cabinet, cord less remote
control, drain pan, necessary accessories etc., suitable for
operation on 230 V ± 10%, 50 Hz, single phase AC supply,
complete as required. The Indoor units must shut down
upon receiving a singal from the BMS System/Fire
Singnals. The system shall be capable to adjust air flow as
per room requirement automatically. The cooling capacity
of indoor unit will be at air inlet conditions of 27 0C DB and
19 0C WB temperature. (Make will be same as of Outdoor
VRF/VRV indoor Supplying, Installation, Testing and Commissioning of
AC unit (ceiling following minimum capacity 4 way Cassette Type Indoor
mounted 4 way) ceiling mounted unit equipped with synthetic washable
media pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with DX
Copper coil, electronic expansion valve, outer cabinet,
drain pump, grill, necessary supports, vibration Isolation,
3 31.4 Corded remote control etc., suitable for operation on single
phase 230 V ± 10%, 50Hz AC supply, complete, as
required. The Indoor units must shut down upon receiving
a singal from the BMS System/Fire Singnals. The system
shall be capable to adjust air flow as per room requirement
in auto mode. The cooling capacity of indoor unit will be at
air inlet conditions of 27 0C DB and 19 0C WB temperature.
(Make will be same as of Outdoor)
S.No. DSR 2022 Item Name Description of Item Unit Quantity Rate Amount
Copper piping Copper piping: - Supply, installation, testing and commissioning of
interconnecting copper refrigerant pipe work (19mm/13mm thick)
duly insulated with elastomeric nitrile rubber type tubular insulation
between indoor & outdoor units as per specifications. And exposed
piping should be wrapped with glass woven cloth and lag coating
for vapour barrier and weather protection. Joints shall be covered
with nitrile rubber tape of 3 mm thick complete as per specification.
44 mm OD 44 mm O.D. wall thickness ≥ 1.4mm (insulation – 19 mm thick) Rmt 10 3203.00 32030.00
41.1 mm OD 41.1 mm O.D. wall thickness ≥ 1.4mm (insulation – 19 mm thick) Rmt 35 2569.00 89915.00
38 mm OD 38 mm O.D. wall thickness ≥ 1.4mm (insulation – 19 mm thick) Rmt 56 2135.00 119560.00
34.9 mm OD 34.9 mm O.D. wall thickness ≥ 1.4mm (insulation – 19 mm thick) Rmt 75 1967.00 147525.00
28.6 mm OD 28.6 mm O.D. wall thickness ≥ 1.2mm (insulation – 19 mm thick) Rmt 85 1501.00 127585.00
25 mm OD 25 mm O.D. wall thickness ≥ 1.2mm (insulation – 19 mm thick) Rmt 66 1349.00 89034.00
22.2 mm OD 22.2 mm O.D. wall thickness ≥ 1.0mm (insulation – 19 mm thick) Rmt 45 1054.00 47430.00
19.1 mm OD 19.1 mm O.D. wall thickness ≥ 1.0mm (insulation – 13 mm thick) Rmt 36 960.00 34560.00
15.9 mm OD 15.9 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) Rmt 28 944.00 26432.00
12.7 mm OD 12.7 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) Rmt 18 744.00 13392.00
9.5 mm OD 9.5 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) Rmt 15 635.00 9525.00
6.4 mm OD 6.4 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) Rmt 5 514.00 2570.00
Drain piping Drain piping :- Providing and fixing of CPVC, 6Kg/cm2 drain water
piping with fittings, support and insulated with 6 mm thick closed
cell elastomeric nitrile rubber insulation complete as per
Y joints Y joints:- Supply, installation, testing & commissioning of ref nut/Y-
6 NSR-102 joints brass for indoor and outdoor units of suitable size as per Each 26 5940.00 154440.00
Control cable Controlcable: - Supply and laying, testing & commissioning of
following sizes of copper conductor control cables on existing tray
including fixing clamps & proper connections to equipment etc.
complete as required.
Communication Controlcable: - Supply and laying, testing & commissioning of
cable following sizes of shielded copper conductor Communication cables
on existing tray including fixing clamps & proper connections to
equipment etc. complete as required.
Outdoor stand Outdoor stand fabrication :- Supply, fabrication and erection of
fabrication angle/channel/flat iron stand, hanging arrangement for air
conditioning machines & ducts etc, back /support clamps or other
9 NSR-105 similar work etc. including nut bolts of required size, making holes, Kg 40 92.00 3680.00
fabrication, welding, cutting, etc. and painting with one coat of red
oxide paint & two coat of enamel paint as required as per
TOTAL DSR ITEMS 1104134.00
TOTAL NON DSR ITEMS 1230028.00
TOTAL DSR + NON DSR ITEMS ₹ 23,34,162.00
PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA
Name of Project:-
AT, DISTRICT- GWALIOR (M.P.)
S.No. of Project Sub Head :-
S.No. of Component :- D
Name of Component :-LAN SYSTEM
S.No. DSR 2022 Item Name Description of Item Unit Quantity Rate Amount
S/F Modular Boxes, Base & Cover Plate :- -
1.00 1.27 Supplying and Fixing Following Size/ Modules, GI Box Alongwith -
Modular Base & Cover Plate for Modular Switches in Recess etc. as
1.27.2 3 Module (100mmX75mm) Each 0 384.00 -
2.00 1.21 Supplying and fixing of following sizes of medium class PVC conduit - -
along with accessories in surface/recess including cutting the wall and
making good the same in case of recessed conduit as required.
3.00 39.71 Supplying, drawing, Installation, Testing and commissioning of CAT6 - -
UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface,
Category 6 Unshielded Twisted Pair, 4 pair should be complied as per
UL/ETL verification program for compliance with ANSI/TIA-568.2-D
standard. Outer diameter should be in the range of 6.1mm nominal with
Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X
Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as
RJ-45 computer Supply, installation testing and commissioning RJ - 45 computer
jack (1Module) jack cat 6 with shutter modular (1Module)
Cat 6 with RJ - 45 computer socket cat 6 with shutter modular (1Module)
shutter modular
4 Pair shielded Supplying and drawing 4 pair shielded twisted pair (STP), 0.5 mm
twisted pair PVC insulated copper conductor un-armoured Cat-6 computer
5 NSR-107 (STP) cable FR-LSH in existing surface/concealed, steel/PVC. conduit/ Metre 111 113.00 12543.00
casing-n-capping as required.
Patch cord Supply, installation testing and commissioning of patch cord as
mentioned below :-
CAT 6 RJ45, CAT 6 RJ45 patch cord UTP 1 metre
CAT 6 RJ45, CAT 6 RJ45 patch cord UTP 2 metre
CAT 6 RJ45, CAT 6 RJ45 patch cord UTP 3 metre
Patch panel, RJ Supply, installation testing and commissioning of 19" modular
45 patch - 1 U patch panel 24, RJ 45 cat-6 connector
Rack Supply, installation testing and commissioning of wall mounting
8 NSR-110 rack, for computer switches/Patch Panel etc complete as
mentioned below :-
9U cabinet 9U cabinet with min. Dimension 488X600X600, wall mounting with
6 point 5 Amp. socket power supply strip, and fan, cable manager, each 1 14134.00 14134.00
tray as per Site requirement
12U cabinet 12U cabinet with min. Dimension 590X600X600, wall mounting
with 6 point 5 Amp. socket power supply strip, and fan, cable each 4 19668.00 78672.00
manager, tray as per Site requirement
9 NSR-111 CAT6A/OFC Networking (10G Support)
6 Core OS-2 SM SITC of 6 Core OFC Cable with Armored Uni‐Tube, 9/125μm,OS
Cable 2 Type, . Complying to ISO/IEC 11801, EN50173, ANSI/TIA 568-
10 NSR-112 C.3, Telcordia GR-20, Uni-tube construction,Water Blocking Metre 114 124.00 14136.00
Thixotropic Gel (Tube) Petroleum Jelly (Interstices) in indoor /
outdoor ducts, direct burial and backbone cabling
Termination LIU
6 Port LIU SITC, Splicing, Termination of 6 Port Full loaded LIU with SC-
LC/LC-LC / SC-SC adopter, Splicing tray, Pigtails, Termination, 1U
19” / ETSI versions available, Slidding Drawer for easy access of
back side of connector, Fiber guides, radius controls & secure tie
12 Port LIU SITC, Splicing, Termination of 12 Port Full loaded LIU with SC-
LC/LC-LC / SC-SC adopter, Splicing tray, Pigtails, Termination, 1U
19” / ETSI versions available, Slidding Drawer for easy access of
back side of connector, Fiber guides, radius controls & secure tie
12 NSR-114 SITC OF Gigabit Unmanaged Desktop Switch
24-Port Gigabit 24-Port Gigabit Unmanaged Desktop Switch. Full wire-speed data
Switch transmission. Energy-efficient design. 1000Base-T Interface : 24.
Auto MDI/MDIX .Switching Capacity : 48 Gbps. Operation
Temperature 0 ~ 40 °C. Power Input AC:100 ~ 240 V.
MAKE- Insight Managed WiFi 6
NETGEAR & AX3000 Dual-Band Multi-Gig PoE Wireless Access Point
EQUIVALENT Interface:- One 100/1000/2.5GBASE-T Gigabit Ethernet
(RJ-45) ports with Auto Uplink™ (Auto MDI-X)
supporting IEEE 802.3af or 802.3at Power over
Ethernet (PoE) , LED:- Four (4): Power and Cloud connection;
LAN speed; 2.4GHz status; 5GHz status, Security:- WiFi
Protected Access® (WPA, WPA2, WPA3) WPA2 and WPA3
Enterprise Wireless access control to identify authorized wireless
network devices MAC address authentication, Network
Management :- App management for setup, monitoring and
MAKE- WAX620 Ap, Dual‐Band Wi‐Fi 6 (802.11ax) Business Access
NETGEAR & Point, 4×4 streams, AX3600 (up to 3.6 Gbps aggregate). Features
EQUIVALENT include 1 × 2.5 GbE PoE+ port (802.3at), support for up to 8
14 NSR-116 SSIDs/VLANs, WPA3 enterprise‐grade security, Each 1 64260 64260
OFDMA/MU‐MIMO, mesh capability, remote management via
Netgear Insight (1‐yr subscription included), 5‐year hardware
warranty. Compact ceiling/wall mount form factor
MAKE- 24-Port Gigabit PoE+ Smart Switch with 2 SFP Ports and Cloud
NETGEAR & Management24-Port Gigabit PoE+ Smart Managed Switch with 2
EQUIVALENT SFP Uplinks and Cloud Controller : 24×10/100/1000 Mbps Gigabit per
15 NSR-117 Ethernet ports with PoE+ (802.3at, up to 30 W per port), total PoE access 2 20358 40716
power budget of 190 W. Includes 2×1G SFP uplink ports for fiber point
connectivity. Advanced Layer 2+ features: VLAN, QoS, LAG,
IGMP Snooping, ACLs. Supports local web GUI and centralized
MAKE- Rack‐mountable, fully‐managed AV‐optimized Ethernet switch
NETGEAR & featuring 24 × 1 GbE PoE+ ports (802.3at, rear-facing), 2 × 1 GbE
EQUIVALENT RJ‐45 management/uplink ports, and 4 × 10 GbE SFP+ uplink
ports; 480 W PoE budget; non‐blocking 132 Gbps backplane,
forwarding rate 98.21 Mpps; front status panel; fan‐mode
16 NSR-118 selectable (fanless/quiet/cool); IT & dedicated AV GUIs, IGMP Each 1 118692 118692
Plus, Auto‐Trunk/LAG, multicasting support, L2+/L3 routing,
USB‐C & RS‐232 console, reversible mounting brackets.
Model/Part No.: GSM4230PX‐100NAS (Americas),
GSM4230PX‐100EUS (EMEA), GSM4230PX‐100AJS
TOTAL AMOUNT (DSR ITEM) 77626
TOTAL AMOUNT (DSR ITEM) 77626
TOTAL AMOUNT (NON-DSR ITEM) 629065
TOTAL AMOUNT (NON-DSR ITEM) 629065
TOTAL AMOUNT DSR+NON DSR ITEM 706691
TOTAL AMOUNT DSR+NON DSR ITEM 706691
Name of PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA AT,
Project:- DISTRICT- GWALIOR (M.P.)
S.No. of Project Sub Head :- 1
S.No. of Component :- D
Name of Component :- TELEPHONE
Abstract Of Cost
S.No. E&M 2025 Description of Item Unit Quantity Rate Amount
S/F Modular Boxes, Base & Cover Plate :- -
1.00 1.27 Supplying and Fixing Following Size/ Modules, GI Box Alongwith -
Modular Base & Cover Plate for Modular Switches in Recess etc. as
S/F Modular Type Switch / Socket :- - -
2.00 1.24 Supplying and Fixing Following Modular Switch/ Socket on The - -
Existing Modular plate & Switch Box including connections But
Excluding Modular Plate etc. as required.
1.24.6 Telephone Socket outlet. Each 0 168.00 -
1.24.7 TV Antenna socket outlet. Each 0 168.00 -
3.00 1.21 Supplying and fixing of following sizes of medium class PVC conduit - -
along with accessories in surface/recess including cutting the wall and
making good the same in case of recessed conduit as required.
4.00 1.18 Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC - -
insulated annealed copper conductor, unarmored telephone cable in
the existing surface/ recessed steel/ PVC conduit as required.
5.00 1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid Metre 240 54.00 12,960.00
copper conductor PE insulated, shielded with fine tinned copper braid
and protected with PVC sheath in the existing surface/ recessed steel/
PVC conduit as required.
6.00 39.17 Supplying, drawing, Installation, Testing and commissioning of - -
CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing
conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair
should be complied as per UL/ETL verification program for
compliance with ANSI/TIA-568.2-D standard. Outer diameter
should be in the range of 6.1mm nominal with Operating
Temperature Range : -5° to +60°C, Bending Radius : < 4 X
Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc.
complete as required.
39.17.1 1 run of cable Metre 9 60.00 540.00
NSR-119 Supply installation, testing and commissioning of 0.5 mm size
solid annealed copper, jelly filled telephone cables, polythene
insulated, petroleum jelly filled with poly-al laminate moisture
7 barrier, polythene sheathed, armoured polythene jacketed
telephone cables as per DOT specifications of following sizes
S.No. E&M 2025 Description of Item Unit Quantity Rate Amount
NSR-120 Supply, installation testing and commissioning of telephone tag
8 block krone connector with enclosure complete as mentioned
NSR-121 Supply, fixing and testing of RJ 11 telephone jack modular (1
NSR-122 Supply, installation, testing and commissioning of EPABX
system consist, no. of extension, no of junction, no. of
expandable eport, operating console, current on max. load with
ISDN compatible of approved make and labor as required as
per specifications.
EPABX system consists of 16 nos. extensions, 8 nos of junction
&upto 64 nos. of expandable eport, with one operating console, Each 1 70086.00 70086.00
1.35 Amp max. current
NSR-123 Supplying & fixing float cum boost charger for EPABX system of
approved make with all necessary material as required as per
11 specifications.
50 Amp 48 V float cum boost charger Each 1 56344.00 56344.00
NSR-124 Supplying, fixing essential additional accessories to EPABX
12 system of approved make with all necessary material as
required as per specifications.
EPABX E-1 card Each 1 30665.00 30665.00
EPABX-operator console Each 1 6994.00 6994.00
4 push button CLI phone. Each 9 774.00 6966.00
TOTAL AMOUNT (DSR ITEM) 49334.00
TOTAL AMOUNT (DSR ITEM) 49334.00
TOTAL AMOUNT (NON-DSR ITEM) 188822.00
TOTAL AMOUNT (NON-DSR ITEM) 188822.00
TOTAL AMOUNT DSR+NON DSR ITEM 238156.00
TOTAL AMOUNT DSR+NON DSR ITEM 238156.00
Name of PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA AT,
Project:- DISTRICT- GWALIOR (M.P.)
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICAI BUILDING
S.No. of Component :- D
Name of Component :- CCTV external
Abstract Of Cost
S. No. E&M 2025 Description Unit Quantity Rate (In Rs) Amount (In Rs)
1.00 39.18 Supplying, drawing, Testing and commissioning of Cat6A UTP
4 pair, 23 AWG solid copper cable in existing conduit/ on
surface, U/FTP, LSZH, Non Plenum, Horizontal (solid) Cable
suitable for high speed data networking application supporting
upto 10Gbps over a 100 meter channel. The 4 Unshielded
Twisted Pairs (UTP) cable with color coded insulation for easy
indentification should have FLAME PROPERTIES i.e.
Flammability Test - IEC 60332-1, Smoke Density - IEC 61034,
LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC
11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS.
The outer Cable Diameter should be 7.5 + 2 mm. Cable should
have been tested and verified by UL/ ETL etc. complete as
2.00 1.21 Supplying and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of recessed
conduit as required.
40.2 Supplying Installation Testing and Commissioning of 2MP
Fixed Lens IP IR Outdoor Bullet Camera having following
specifications and features etc :- 1) Signal System: PAL/NTSC,
Signal to Noise Ratio: > 50 dB,Camera should display Camera
title, Date & Time in live & recorded video 2)Image Sensor:
1/2.8" or better progressive Scan
CMOS to get color image even at night
condition(Minimum Illumination: 0.006 Lux@ F1.4,
AGC ON, 0 lux with IR or better) True Day & Night
High Performance Mechanical IR cut filter with auto
switch, Integrated IR Source (Auto, Manual)- Inbuilt
Smart IR LED's with effective distance upto 50 meter
or better and 30 meter for colour view in night,
Imaging: 1/3s to 1/30000s electronic shutter support,
Auto Gain Control , White Balance- Auto, Back Light
Compensation, Multi zone Privacy Masking, HLC,
Digital Watermarking.
3) Compression (Minimum):-Video:- H.265 or better,
H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726,
4) Wide Dynamic Range:- WDR (120db or more)
5) Digital Noise Reduction:- DNR (3D) On/Off
6) Video Streaming & Frame Rates :- Triple streaming
configurable(Main
S. No. E&M 2025 Description Unit Quantity Rate (In Rs) Amount (In Rs)
14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should
support 1 x Built-In Mic and 1/1 Alarm In/ Out for External
Mic. and Speakers as per site requirement. 16) Power Input: The
camera should support simultaneous dual power input—12 VDC
(via power adapter) and PoE (802.3af)—to ensure continuous
operation in the event of a failure in one power source. 17)
Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE 18)
Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body
40.2.1 40.2.2 40.3 19) Operating Condition:- Ambient
Temperature:- ( )05°C to 50°C, humidity 95% (max) (non-
condensing) 20) IR life: 40000 hours or higher 21) Video Bit
rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER,
STQC Certified, CE, FCC and RoHS
4.00 40.2.1 2MP @ 25/30fps@1080P (1920×1080) Outdoor Bullet Camera
with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized Each 8 19,796.00 1,58,368.00
5.00 40.10 Supplying Installation Testing and Commissioning of ollowing
Channel Network Video Recorder (NVR) with camera licenses
to record for all channels having specifications and features etc
as mentioned below : 1) Network Video Recorder Embedded/
Installed OS (Linux) along with Camera Licenses for number of
channels of NVR to record per NVR and to provide a live view,
storage and simultaneously Multi-channel playback of all IP, IR
camera or more and must be ONVIF with minimum support of
256Mbps incoming Bandwidth. 2) NVR should support H.265
or better, H.264,
MJPEG, MPEG4 support
3) Must support 1 channel Input, 1 channel Output,
RCA for Two-way Talk
4) Intelligent auto power on when power resumes after
5) Storage: It should support minimum 2 SATA Slots
with 20TB capacity/ Slot.
6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps
Ethernet Ports, 1x RS485, 1x RS232
7) Backup Interface : Its should have 2 Nosx USB port
(1x USB3.0, 1xUSB2.0)
8) Video Output Ports: 1x HDMI and 1 VGA
9) Alarm Ports: It should have 4/1 Ch In/ Out ports to
connect various type of external sensors and output
devices like hooter/ Siren etc.
10) Email & SMS Altert options: Option for SMS/ Email
Alerts to minimum 5 designated mobile number for
power failure, HDD failure, vandalism, tempring,
network disconnection and panic
11) Web & Mobile Application: Web, Mobile app ( For
S. No. E&M 2025 Description Unit Quantity Rate (In Rs) Amount (In Rs)
19) The OEM must provide its own DDNS server hosted in
India, eliminating the need for a public IP address for remote
monitoring over the Internet. 20) Must support Resolution:
1280×1024,1280×720, 21) Must support recording resolution
upto 32MP 22) Must support Continuous, Alarm, Motion,
Instant, Panic Recording Mode 23) When alarm recording is
enabled and an event occurs, you can click the alarm icon on
monitoring page to view the alert details. The snapshot function
is supported on monitoring and playback page 24) The Network
Video Recorder (NVR) shall be configured to send email
whenever a system message is created or an alarm event occurs.
The email server shall be a valid SMTP server. Each recipient
email address shall be configured to receive any combination of
critical, warning, or informational messages or alarm
notifications. When an alarm occurs, the email message includes
the NVR name, time of alarm and a list of camera that is
configured to record upon alarm 25) It should support Network
Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP,
NTP, UPnP, Multi IP Setting. Convert multiple recording files to
one avi/MP4 file. 26) General AI Based Search: Search Pictures
by channel, time, event type, target classification (Fall Detection,
People Approach Detection, People No. Exception Detection,
People Staying Detection, Violence Detection. 27) Alarm
Notifications based on: Motion detection, video tampering,
video loss, scene changing, PIR alarm, Camera external alarm,
Face detection, face recognition, perimeter protection (intrusion
and tripwire), ANPR, people counting, stereo analysis, crowd
distribution, heat map, Disk Full, Storage Error, IP Conflict and
Built-In of fan
Artificial 28) AlarmNVR
Intelligence: Notification should
should have be AI
:-- 2 Channel face detection and recognition, - Minimum 4
Channel perimeter protection, - Minimum 8 Channel Smart
Motion Detection 30) Face Recognition Database Capacity: It
should support total Blacklist and Whitelist capacity of
Minimum 20,000 Faces or more with Face Detection speed of
12 face images/sec. 31) Face & Human Attributes Search:
Search Pictures/ Video by Gender, age group, glasses,
expressions, face mask, beard, Top color, top type, hat, bag, age,
gender and umbrella. 32) ANPR Capability: It should support
ANPR Camera with License plate, plate color, vehicle body,
vehicle model, vehicle logo, calling, seatbelt, vehicle registration
location etc vehicle attributes. 33) Alarm Notifications based on:
Motion detection, video tampering, video loss, scene changing,
PIR alarm, Camera external alarm, Face detection, face
recognition, perimeter protection (intrusion and tripwire),
ANPR, people counting, stereo analysis, crowd distribution, heat
map, Disk Full, Storage Error, IP Conflict and abnormal
behavior of fan, cybersecurity exception 34) Alarm Notification
should be linked with Recording, snapshots, Camera external
alarm output, buzzer, logs, presets and email. 35) General AI
Based Search: Search Pictures by channel, time, event type,
target classification (Fall Detection, People Approach Detection,
People No. Exception Detection, People Staying Detection,
Violence Detection. 36) Smart playback function: Should
support smart search for the selected area in the video and smart
playback to improve the playback efficiency 37) VCA (Video
Content Analytic): Should support multiple video contented
analytics based on camera
40.10.2 16 Channel Network Video Recorder (NVR) having display
split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16
S. No. E&M 2025 Description Unit Quantity Rate (In Rs) Amount (In Rs)
40.12 Supplying, Installation, Testing and Commissioning following
capacity Serveillance grade Hard Disk with upto 256MB/s
Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch
form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE,
FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV,
UL Certifications.
26.1 Online UPS - Input supply: Single Phase, Output Supply: Single
Phase. Supplying, installation, Testing & Commissioning of
following capacity at full load (Unity Power Factor) ON LINE
Uninterrupted Power Supply (UPS) system suitable for Single
Phase input, Single Phase output AC Supply. The UPS shall
include a Rectifier, inverter, battery bank suitable for 30 minutes
back up (Battery VAH capacity shall not be less than 1600 VAH
per KVA of UPS rating per Hour backup time) on full load
(Battery shall be VRLA, SMF in ABS Container) and Static
Bypass switch along with provision for manual bypass, suitable
isolation transformer for additional protection against neutral
faults etc. The UPS systems shall be Microprocessor based
Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s
both for the rectifier & inverter with PWM (Pulse Width
Modulation) Technology. The quality of design, manufacturing
and inspection process should confirm to the relevant Inter-
national standards such as IEC/EN/VDE. The operating
efficiency of the UPS systems shall be >95% at 100% non-linear
loads. Current total harmonic distortion(ITHD)/ total demand
distortion (TDD) on the input grid shall be < 5% at 100 %load.
(The required LC filters shall be included in UPS cost), extreme
power factor kit to be include to limit the input pf to 0.99 and
output power factor shall be unity (i.e. kw rating of the UPS
shall be kva rating x 1 ) however UPS shall be suitable to take
load at 0.7 laging to 0.7 leading power factor loads. UPS shall be
suitable for incoming supply AC single phase 160-270V 50 Hz
and delivering output AC supply true sine wave single phase
220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120%
for 10 mins and 150% for 1 minute. Operating temperature 0 to
40 0C, Relative
circuit, battery humidity 0-95% non
deep discharge , 10condensing,
KV surge.noise level for
watt/VA,Amp and Voltage power parameters etc. UPS shall
comply with low voltage electromagnetic compatibility (EMC)
achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a
Voltage and Frequency Independent (VFI) type UPS (as per
standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT
Based Inverter Technology, Communication RS232/ RS485/
SNMP port open protocol for BMS integration as per approved
by Engineering in charge. Required battery racks, DC breaker of
suitable rating and interconnecting copper conductor cable of
suitable size and connectors and all required accessories are
inclusive in the cost. The UPS should have QR code which
should contain drawing, test report OEM manual, Geo- Tag of
manufacturing location etc
7.00 NSR-128 Supply, Installation, testing and commissioning of 16 port POE
Data switch connections as per specifications complete as Each 1 19,133.00 19,133.00
required. (Cisco , Netgear , Dlink or Equivalant)
9.00 NSR-130 S.I.T.C.32" Color flat panel LED Monitor,Full HD Professional
Series 1920 x 1080 resolution, inputs. 100-230VAC/50 Hz. Each 1 23,483.00 23,483.00
TOATAL DSR ITEMS 3,76,487.00
S. No. E&M 2025 Description Unit Quantity Rate (In Rs) Amount (In Rs)
TOTAL NON DSR ITEMS 42,616.00
TOTAL DSR + NON DSR ITEMS 4,19,103.00
Name of PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA
Project:- AT, DISTRICT- GWALIOR (M.P.)
S.No. of Project Sub Head :- 1
S.No. of Component :- D
Name of Component :- STREET LIGHT
Abstract Of Cost
S.No. DSR 2022 Description of Item Unit Quantity Rate Amount
1 12.3 Erection of metallic pole of following length in cement -
concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 40 mm nominal size) foundation including
excavation and refilling etc. as required.
12.1.1 Above 4.5 metre and upto 6.5 metre Each 3 6,123.00 18,369.00
2 12.6 Supplying and embedding following dia G.I. pipe
(medium class) in pole collar/ foundation (during
casting) for cable entry including bending the pipe to the
required shape complete as required.
3.00 10 Laying of one number PVC insulated and PVC sheathed
/ XLPE power cable of 1.1 kV grade of size up to 35 sq.
10.3.1 ( a ) direct in ground including excavation and refilling Metre 105 200.00 21,000.00
the trench etc. as required, but excluding sand
cushioning and protective covering.
4.00 11 Laying of one number PVC insulated and PVC sheathed
/ XLPE power cable of 1.1 kV grade of following size in
the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm Metre 151 47.00 7,097.00
5.00 14.15.1 Supplying and laying of following size DWC HDPE pipe
ISI marked along with all accessories like socket, bend,
couplers etc. conforming to IS 14930, Part II complete
with fitting and cutting, jointing etc. in the existing
trench, complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal) Metre 150 127.00 19,050.00
6.00 5.18 Providing and fixing 6 SWG dia G.I. wire on surface or Metre 100 42.00 4,200.00
in recess for loop earthing along with existing surface/
recessed conduit/ submain wiring/ cable as required.
NSR-131 Supply and fixing of multi core round FR-LSH PVC
7 insulated copper (flexible) conductor & PVC sheathed
cables 1100Volts as per IS:694-1990 of approved make
(30/0.25 mm) Three core 1.5 sq.mm. Metre 180 54.00 9720.00
S.No. DSR 2022 Description of Item Unit Quantity Rate Amount
NSR-132 Supply and fixing integral post top lantern LED fitting
comprises of copper dust finish cast aluminium spigot
and spun aluminium canopy fixed with opal
polycarbonate, pipe arrangement for vertical mounting,
open construction driver and accessories are wired upto
terminal block. LED of 1 to 3 Watt each assembled on
single MCPCB, having color temp upto 6500K &
having 50000 burning hrs. life with minimum @ L 70,
system lumen output should be minimum with
efficacy>100lm/Watt. LED driver PF > 0.95 & surge
protection 10KV. The colour rendering index of LED
light should be more than 70. Submission LM 79-
08/IS16106 (2012), IEC60598, IEC61347i/c connection
wire, testing etc. to complete the job.
25 Watt LED, color temp 3000-6500k as required. Each 2 4434.00 8868.00
NSR-133 Supply and fixing street light with high power LED of 3
to 6 Watt each on existing bracket assembled on single
MCPCB and additional unique peanut lens on each
LED, system lumens output with efficacy>120 lm/Watt.
luminiare having color temp upto 6500K & 50000 hrs.
burning life with minimum @ L 70, The colour rendering
index of LED light should be more than 70. Luminiare
comprises of driver, PF> 0.95 & surge protection 10KV.
Housing made of pressure die cast aluminium with heat
resistant flat glass, IP65 protection. Submission LM 79-
08/IS16106 (2012), IEC60598, IEC61347 i/c connection
wire, testing etc. to complete the job.
60Watt, color temp 3000-6500k as required. Each 7 10574.00 74018.00
NSR-134 Supply of XLPE insulated power cable (conforming IS-
10 7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4
core ISI marked with alu. stranded /solid conductor
4 core armoured
NSR-135 Providing and erection of hot dipped galvanized
octagonal poles in single section made from 3mm thick
sheet having lockable weather proof flush door junction
box, suitable size & type of foundation bolts 4 nos. 'J'
type (EN8 grade) complete, erected in an approved
manner on provided foundation.
NSR-136 8 meter height, 135 X 70mm A/F, 225x225x16mm base
plate having weight 70 kg ± 3%, 4 nos. X 20 x 750mm Each 3 14489.00 43467.00
bolt having weight 8.2 kg ± 3%.
NSR-137 Providing and fixing of sword canopy type single arm GI
12 bracket upto 2 meter Long for 90mm A/F top octagonal Each 7 2237.00 15659.00
NSR-138 Providing and fixing of bakelite sheet 10mm thick, one
MCB 6Amp-32Amp SP & 16sq.mm stud type 4 way
epoxy connector for decorative designer poles
/octagonal pole box.
S.No. DSR 2022 Description of Item Unit Quantity Rate Amount
NSR-139 Designing and construction of footing foundation for
octagonal pole of desired size including excavation in
soil/soft rock, base concrete M-7.5 (1:4:8), 15mm thick
and pedestal of RCC M-20 (1:1.5:3), required tar steel
reinforcement for required size from base concrete,
shuttering, curing etc. with existing foundation bolts
complete as per specifications in an approved manner
as per manufacturer drawing or engineer-in-charge.
TOTAL AMOUNT (DSR ITEM) 74198.00
TOTAL AMOUNT (DSR ITEM) 74198.00
TOTAL AMOUNT (NON-DSR ITEM) 193147.00
TOTAL AMOUNT (NON-DSR ITEM) 193147.00
TOTAL AMOUNT DSR+NON DSR ITEM 267345.00
TOTAL AMOUNT DSR+NON DSR ITEM 267345.00
Name of PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA AT,
Project:- DISTRICT- GWALIOR (M.P.)
S.No. of Project Sub Head :- 1
S.No. of Component :- D
Name of Component :- SOLAR
Abstract Of Cost
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
1 17.1 Supplying Installation, Testing and Commissioning of on-grid
Solar Photovoltaic Power Plant conforming to various applicable
standards BIS, IEC, MNRE guidelines, the Central Electricity
Authority Regulations and CPWD Specifications as amended up
to date, consisting of Mono/Poly Crystalline silicon solar cells
module, net metering facility, necessary control, protections,
earthing, cabling, mounting structure, junction boxes, power
conditioning units, Real time online web interfaced Data
Monitoring System, Distribution panels, grid connecting
arrangement, conduits, pipes, cable trays and other accessories
etc. as required. a) High Energy Efficiency Solar Photovoltaic
Module of capacity 330 Wp or above, manufactured in India,
conforming to IS 14286/IEC 61215, IS/IEC 61730 Part-1, IS/IEC
61730-Part-2. Solar Photovoltaic Module conversion efficiency
shall not be less than 23% at STC with temperature coefficient of
Pmax better than -0.30% per 0C. PV modules used in solar
power plants/ systems must be warranted for their output peak
watt capacity, which should not be less than 90% at the end of 10
years and 80% at the end of 25 years. Solar Modules shall be
designed to operate in relative humidity upto 100% with
temperature between -10 0C and +85 0C. Further, each PV
module used in any solar power project must have Radio
frequency identification tag with information such as name of
manufacturer, month and year of manufacturing, country of
origin (separately for Solar cell and module), I-V curve, Unique
Serial No and Model No of the module, Wattage, Im, Vm and FF,
name of test lab issuing IEC certificate. b)Power Conditioning
Unit (PCU) of 350-800 V DC Input voltage range and 415 V
AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable
to generate AC with a variation of 10% at nominal voltage.
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
meter and data logger, MPPT, switching devices
IGBT/MOSFETs and controller Microprocessor /DSP.
PCU/inverter shall be capable of complete automatic operation
including wake-up, synchronization & shutdown. The PCU shall
be able to withstand unbalanced load conforming to IEC standard
with shutdown/standby mode. It must be provided with grid
islanding along with manual disconnect pole isolation switch
besides automatic disconnection. Minimum protections: Mains
Under / Over Voltage, Over current, Over/Under grid frequency,
Over temperature, Surge voltage induced at output due to external
source, Short-circuit, Lightening, Anti Islanding (for grid synch.
Mode) and other protections as per applicable standards.
LCD/LED display of minimum parameters: DC input voltage,
DC current, AC Voltage and current (all 3 phases, in case of 3
phase), Instantaneous & cumulative AC output power, Daily DC
energy produced and other parameters applicable standard.
Communication interface RS 485 / RS 232. c) Module mounting
structure: The roof top solar plant generation units shall be
installed by using supporting Aluminium/Galvanized MS
structure (mass of zinc coating shall be as per IS4759 ) having
minimum head room clearance of 2.4 meter above the terrace
level / ground level. The mounting structure would be designed to
sustain wind load and seismic parameter of the site of
installation. All the structure shall be design as per applicable BIS
code and the material shall also confirm the applicable BIS Code.
Structural material shall be corrosion resistant and electrolytically
compatible with the materials used in the module frame, its
fasteners, nuts and bolts. The suitable arrangements for
maintenance and cleaning shall be provided. d) Real time online
accessories etc.Data Monitoring
as required. System
junction withbe made of
GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with
full dust, water & vermin proof arrangement with High quality
Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor
diode with resistant applied voltage)/ surge arrestors and suitable
Reverse Blocking Diodes, isolation switches isolate the DC input
to Inverter, copper bus bar etc. f) Lightning, surge voltage
protection, earthing protection and grid islanding. g) Cables:
Connections & Interconnections by required size IR/UV kwp 10.00 54280.00 542800.00
protected XLPE insulated copper conductor 1.1 kV grade
armored power and control cables(ISI Marked) along with
supplying & fixing of necessary channel/conduit, GI cable trays,
supports, lugs, thimble and other accessories etc. as required. h)
DC Distribution Board And AC Distribution Panel Board: IP65,
free standing, metal cladded, having copper bus bar, having
required protection and control gears, connection-interconnection,
etc. as required. 93
TOATAL DSR ITEMS 5,42,800.00
TOTAL NON DSR ITEMS -
TOTAL DSR + NON DSR ITEMS 5,42,800.00
Name of PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA AT, DISTRICT-
Project:- GWALIOR (M.P.)
S.No. of Project Sub Head :- 1
S.No. of Component :- D
Name of Component :- DG SET
Abstract Of Cost
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
29.1 D.G.Set and associated works
Description Supplying, Installation, Testing & Commissioning of Unit
Rate ‘Silent Type Diesel Generating set as per CPCB IV + or better
norms along with having Prime Power Rating of KVA as below, 415
volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50
Hz, 3 phase system & for 0.85 Load Factor, including testing at
factory and site with fuel, load for test and other necessary
arrangements Complete as per CPWD specifications, should have
QR code which should contain drawing, test report OEM
manual,Geo- Tag of manufacturing location, rating plate as per
relevant IS Code etc. and consisting of the followings: (A) Diesel
Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi
cylinder, dynamically balanced fly wheel, electric start of suitable
BHP at 1500 RPM suitable for above output of alternator at 40 0C,
50% RH & at 1000 Meter MSL , capable of taking 10% over loading
for one hour after 12 hours of continuous operation. The engine will
be with Electronic governor, Dry type Air filter with service indicator,
first filling of engine fuel (after commissioning) lubricating Oil,
Coolant and other consumables complete with all the required
accessories, the Electronic governor shall be as per ISO 8528.The
engine shall comply to the latest CPCB norms (CPCB IV + or better)
and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS
13018 and as per CPWD specifications. (B) Engine mounted
Instrument Panel fitted with and having digital dis Plate for following:
(i) Start-stop switch with key (ii) Water temperature indication (iii)
Lubrication oil pressure indication (iv) Lubrication oil temperature
indication (v) Battery charging indication and Voltage indication (vi)
RPM indication (vii) Over speed indication (viii) Low lubricantion Oil
trip indication (ix) Engine Running Hours indication (x) Fuel Level
(C) Alternator: Synchronous alternator rated of appropriate KVA,
415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging
power factor at 40 0C, 50% RH & at 1000 Meter MSL. The
alternator shall be having Screen Protected Drip Proof (SPDP)
enclosure IP23, brushless, continuous duty, dynamically balanced
rotor, capable of taking 10% over loading for one hour after 12 hours
of continuous operation, self cooled,self-excited and self-regulated
through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613
suitable for tropical conditions and with class- H insulation. (D) Base
Frame & Foundation: Both the engine and alternator shall be
mounted on suitable base frame made of MS channel with
necessary reinforcement which shall be installed on suitable cement
concrete foundation and vibration isolation arrangement as per
recommendations of manufacturer. (E) FUEL TANK: Daily service
fuel tank of suitable liters capacity as per CPWD Specifications,
fabricated out of 3 mm thick M.S. sheet complete with all standard
accessories and fuel piping between fuel tank and diesel engine with
MS class ‘C’ pipes of suitable dia. Complete with valves, level
indications & accessories as required as per specifications. (F)
Exhaust System: Dry exhaust manifold with hospital type exhaust
silencer and catalytic convertor. (G) Starting System: 12V/24V DC
starting system comprising of starter motors: voltage regulator and
arrangement for initial excitation complete with suitable numbers of
batteries (180 AH capacity lead acid SMF type) as required as per
specifications. The battery shall be housed inside the acoustic
enclosure of DG Set.
(a) (H) Acoustic and weather proof enclosure with arrangement for fresh
air intake for cooling of the engine & alternator, extraction,
discharging hot air in to the atmosphere and the temperature rise
inside the enclosure, noise level outside enclosure. The acoustic
enclosure should be suitable for cable connection/connection
through bus-trunking. Such arrangements on acoustic enclosure
should be water proof & dust-proof conforming to IP-65 protection.
The enclosure shall be as per CPCB IV + or better norms etc. and
as per CPWD specifications. (I) AMF Panel: Free standing floor
mounted IP 42 automatic mains failure control panel including auto
by-pass, suitable for KVA as below for silent type DG set complete
with relays, timers, set of CTs for metering & protection and energy
analyser to indicate currents, phase and line voltages, frequency,
power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA
(Phase & Total), KW & provision for overload, short circuit, restricted
earth fault, under frequency, power (aluminium) and control (copper
) cabling of suitable size upto 15 meter between AMF panel, LT
Panel and DG Set including connection interconnection etc. as
required, all complete and inter locking and communication/
Ethernet /RS485/SNMP port open protocol for BMS integration
including suitable software, the panel shall be of DG Set OEM make
etc. as per approved by Engineering in charge and including the
following: 1. Suitable numbers and appropriate capacity 4 pole
motorised electrically operated draw out with cradle type 3 position
ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2.
Auto/Manual/Test/Off selector switch 3. Protection for under and
over voltage phase reversal (2 nos Over voltage relay, 2 Nos.
reverse power relay and 2 Nos. under voltage relay). 4. 3 Sets of
current transformers 15 P 10 accuracy for protection and 15 VA
class-I for metering 5. Energy analyser unit to indicate current,
Voltage( L N & L_L), kW, kVA (Phase & Total), Frequency, KWH,
PF. 6. LED Indicating lamps for load on mains and load on set 7.
Fuse/ MCB for instruments 8. Battery charger, complete with
D.C. voltmeter and ammeter, selector switch for trickle, off and boost
and current adjustment. 9.Main supply failure monitor 10.Supply
failure timer 11.Restoration timer 12.Control unit with three impulse
automatic engine start/stop and failure to start lockout. 13. Impulse
counter with locking and reset facility. 14.ON/OFF/Control circuit
switch with indicator 15.Audio/Video annunciation for (i)High water
temperature (ii)Low lubricating oil pressure (iii)Engine over speed
(iv)Engine fails to start (v)Full load/maximum load warning
16.Protection for over/under Frequency, Loss of AC sensing, Over
Current, Unbalancing load with suitable number of relays and
accessories 17. Maintenance notification based on Engine Run
Hour & due date. 18. Load Management through PLC to achieve
auto opening and closing of incomer breakers, bus coupler
switching of essential panel , interlocking providing signal to AMF
Panel for load status and AMF shall give command to DG Set to
auto start / auto stop depending upon load status and requirement
etc. and necessary hardware and software required to perform the
operation shall be provided by the contractor including all control
2.00 Supply of ISI Marked On-Load Change over switches -
panel mouniting type confirming to IS : 13947 (part I
& III ) with front operated 4 pole, 415 V with two
earthing terminals if required.
63 Amps. (open - execution ) Each 1 4,452.00 4,452.00
3.00 Supplying and fixing exhaust gas piping of 75mm dia. welded black 2 1,382.00 2,764.00
MS, B Class pipe conforming to IS:3589 cut to required lengths and
installed with necessary bends, supports and clamps, anti-vibration
mountings, insulation of exhaust system with mineral
wool/Rockwool, 50 mm thick wiremesh & aluminum cladding etc.,
as required as per specifications.
Supply Of L.T. Cable: -
4.00 Supplying of Following Sizes of 1.1 kV Grade Multicore -
Aluminium Conductor XLPE Power Cable Insulated armoured
cable conforming to IS:7098 (Part - I) or as per Relevant IS Code
complete with all Amendments etc and should be NABL certified
NSR-144 3.5 C X 35 Sq.mm Al. XLPE arm. Metre 15 395.00 5,925.00
NSR-145 3.5 C X 25 Sq.mm Al. XLPE arm. Metre 30 182.00 5,460.00
TOATAL DSR ITEMS 4,03,101.00
TOTAL NON DSR ITEMS 18,601.00
TOTAL DSR + NON DSR ITEMS 4,21,702.00
Name of PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA AT,
Project:- DISTRICT- GWALIOR (M.P.)
S.No. of Project Sub Head :- 1
S.No. of Component :- D
Name of Component :- EXTERNAL ELECTRIFICATION
Abstract Of Cost
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
1 Supplying and erection of galvanised stay set for 11 KV over
head lines complete with 19/ 20 mm dia X 1.8 metres long stay
rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick,
thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/
4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in
cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded
stone aggregate 40 mm nominal size ) foundation including
excavation and refilling etc. as required.
2 Supplying and erection of 11 KV pin insulator complete with
large steel head G.I. pin, nuts, washers etc. as required.
3 Supplying and erection of 11 KV disc insulator for 11 KV
over head lines with galvanised insulator fittings, ball and
socket type and complete with galvanised strain clamps, bolts,
nuts, washers etc. as required.
10.1 LT Cable Laying -
4.00 Laying of one number PVC insulated and PVC sheathed /
XLPE power cable of 1.1 KV grade of following size direct in
ground including excavation, sand cushioning, protective
covering and refilling the trench etc as required.
10.1.4 Above 185 sq. mm and upto 400 sq. mm Metre 110 564.00 62,040.00
5.00 Laying of one number additional PVC insulated and PVC
sheathed / XLPE power cable of 1.1 KV grade of following
10.2 size direct in ground in the same trench in one tier horizontal -
formation including excavation, sand cushioning, protective
covering and refilling the trench etc as required.
10.2.4 Above 185 sq. mm and upto 400 sq. mm Metre 60 423.00 25,380.00
11 LT CABLE JOINTING & END TERMINATION - -
6.00 Supplying and making end termination with brass compression
gland and aluminium lugs for following size of PVC insulated
and PVC sheathed / XLPE aluminium conductor cable of 1.1
KV grade as required.
HT Cable And Accessories
22 H.T. Cable Laying-DSR Item
H V CABLE LAYING -
7 Laying of one number PVC insulated and PVC sheathed /
XLPE power cable of 11 KV grade of following size direct in
ground including excavation, sand cushioning, protective
covering and refilling the trench etc as required.
Laying of one number additional PVC insulated and PVC
sheathed / XLPE power cable of 11 KV grade of following size
22.2 direct in ground in the same trench in one tier horizontal
formation including excavation, sand cushioning, protective
covering and refilling the trench etc as required.
Laying of one number PVC insulated and PVC sheathed /
22.3 XLPE power cable of 11 KV grade of following size in the
existing RCC/ HUME/ METAL pipe as required.
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
Laying of one number PVC insulated and PVC sheathed /
22 XLPE power cable of 11 KV grade of following size in the
existing masonry open duct as required.
8 DSR 10.1 H.T Termination: DSR Item
Supplying and making indoor cable end jointing with cast resin
compound, including lugs and other jointing materials, for
following size of 3 core, XLPE aluminium conductor cable of
11 KV grade as required :
9 Supplying and making outdoor cable end jointing with cast
resin compound, including lugs and other jointing materials,
for following size of 3 core, XLPE aluminium conductor cable
of 11 KV grade as required :
10 Supplying and making straight through cable jointing with heat
shrinkable jointing kit complete with all accessories including
ferrules suitable for following size of 3 core, XLPE aluminium
conductor cable of 11 KV grade as required :
11.0 DSR 2 Miscellaneous Items - DSR -
Providing and fixing M.V. danger notice plate of 200 mm X 150
mm, made of mild steel, at least 2 mm thick, and vitreous enamelled
white on both sides, and with inscription in single red colour on front
side as required.
12 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm,
made of mild steel, at least 2 mm thick, and vitreous enamelled white
on both sides, and with inscription in single red colour on front side
13 Supplying and making cable route marker with cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
10.9 nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 Each 4 683.00 2,732.00
cm at the top with a thickness of 10cm including inscription duly
engraved as required.
14 Supplying and fixing cable route marker with 10 cm X 10 cm X 5
mm thick G.I. plate with inscription there on, bolted /welded to 35
mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in
ground as required.
DSR 5 Earthing -
15 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick
including accessories, and providing masonry enclosure with cover
plate having locking arrangement and watering pipe of 2.7 Meter
long etc. with charcoal/ coke and salt as required.
16 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick
including accessories, and providing masonry enclosure with cover
plate having locking arrangement and watering pipe of 2.7 Meter
long etc. with charcoal/ coke and salt as required.
17 Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including
accessories, and providing masonry enclosure with cover plate
having locking arrangement and watering pipe etc. with charcoal/
coke and salt as required.
18 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in
recess for connections etc. as required.
19 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for
5.18 loop earthing along with existing surface/ recessed conduit/ submain Metre 20 50.00 1,000.00
wiring/ cable as required.
20 Providing and fixing 25 mm X 5 mm copper strip on surface or in
recess for connections etc. as required.
21 Providing and laying earth connection from earth electrode with 6
SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode
including connection with G.I. thimble excavation and re-filling as
LIGHTNING CONDUCTOR
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
23.00 Providing and fixing of lightning conductor finial, made of 25 mm
dia 300 mm long, G.I. tube, having single prong at top, with 85 mm
dia 6 mm thick G.I. base plate including holes etc. complete as
24.00 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or
6.7 surface of wall for lightning conductor complete as required.(For Mtrs. 50 238.00 11,900.00
25.00 Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or
6.8 surface of wall for lightning conductor complete as required.(For Mtrs. 20 201.00 4,020.00
26.00 Jointing copper / G.I. tape (with another copper/ G I tape, base of the
6.3 finial or any other metallic object) by riveting / nut bolting/ sweating Each 6 139.00 834.00
and soldering etc as required.
27.00 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I.
6.12 strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and Each 1 140.00 140.00
spring washers etc. complete as required.
Supplying, installation, testing and commissioning of following
capacity (continuous loading) BEE 5 Star rated (Corresponding
Level as per BIS amended upto date of receipt of tender) , 11/0.433
KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, KNAN [K(K-
Class insulating liquid) Natural Air Natural] copper wound
transformer (Electrolytic grade 99.9% pure copper, Core made of
24.21 first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or
better),Dielectric material shall be type -A, suitable for out
door/indoor applications with Offload Tap Changer/ On Load Tap
Changer (OLTC) ( below 500 KVA offload and above 500 KVA On
Load Tap Changer) on HV side having AVR relay and Remote Tap
Changer Control (RTCC) for automatic sensing of incoming voltage,
operation of OLTC and facility for remote and manual operation of
OLTC HV side in range of +5% to -15% in steps of 2.5%, having
cable end boxes on HV side suitable for 3x300 sq.mm XLPE cable
of 11 KV grade, including bus trunking arrangement on LV side
including supplying and laying of copper conductor multicore
control cable from transformer to HT breaker/panel for safety
tripping, complete with all accessories and safety provisions as per
relevant IS 1180 (Part-3) including first filling of filtered dehydrated
Synthetic organic Ester oil, i/c supplying and grouting of suitable
M.S. Channel with all accessories and transformer shall be
confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 (Part-3) and as
per CPWD specifications complete in all respects etc as required at
site. The maximum flux density in any part of the core and yoke at
rated voltage and frequency shall be such that the flux density with
+12.5 percent combined voltage and frequency variation from rated
voltage and frequency does not exceed 1.9 Tesla. The permissible
temperature-rise shall not exceed 40 0C for oil and 45 0C for
winding up to 200 KVA and 45 0C for oil and 50 0C dg. C for
winding for above 200 KVA. Inside of tank shall be painted with
varnish or liquid resistant paint. For external surfaces one coat of
thermo setting powder paint or one coat of epoxy primer followed by
two coats of polyurethane base paint shall be used. IS: 1180 (Part 3)
shall be referred for paint thickness for normal to medium corrosive
atmosphere. For highly polluted atmosphere and special application
external paint work shall be as per direction of Engineer-in-Charge.
Design ambient condition : a) air temperature 50 0C, b) Relative
Humidity 90 % Max, c) Seismic Zone as per location of site, d)
Altitude as per location/site. Noise level Shall not exceed limits as
per NEMA TR-1 with all accessories running measured as per IEC
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
at minimum, 30°C and maximum operating temperature; c) Air
release device (for non-sealed type transformers) d) Rating and
terminal marking plates; e) Silica gel breather f) Drain-cum-sampling
valve (¾″ nominal size thread, IS 554) preferably steel with plug for
three phase transformers; g) Thermometer pocket with cap; h) Oil
filling holes having (1¼″ nominal size thread) with cover (for sealed
type transformers without conservator); i) Lifting lugs for the
complete transformer as well as for core and winding assembly; j)
Pressure relief device or explosion vent above 200 kVA; k) One
filter valve on the upper side of the tank (for transformers above 200
kVA); l) Unidirectional flat rollers (for transformers above 200
kVA); m) Inspection hole (for transformers above 200 kVA); n) HV
side neutral grounding strip (where one of the HV bushing terminal
is connected to earth); o) Buchholz relay for transformers above 800
kVA. p) Arcing horns or suitable rating lightning arrestors for HT
side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding
temperature indicators for transformers above 200 kVA with suitable
tripping mechanism above permissible limit s) Jacking pads (for
transformer above 1 600 kVA); t) Additional Neutral separately
brought out on bushing for earthing. u) Magnetic oil level gauge (for
transformer above 1600 kVA) with low oil level alarm contact; v)
Non return valve (for conducting pressure test); w) Pressure relief
device or explosion vent x). Monogram Plate y) Inspection cover z).
Detachable type radiators with top and bottom shutoff valve. aa) Oil
Conservator with Oil level indicator, minimum level marking and
drain plug for all transformers of capacity 50 KVA and above. bb)
Necessary hardware, clamps, lugs etc. for termination on HV/MV
etc. for all transformers.
Lightening Arrester System For Transformer
28 Supply, Installation, Testing & Commissioning of Lightening
Arrester HT-12 kV expulsion type complete with all Fitting
transission class discharge capacity 10 kA complete all as as
Miscellaneous Items - MR Items
29 SITC of shock treatment chart (prescribed under I.E.rules) duly
framed with glass and supported from back with hard board with
supply of all material labour T & P etc for proper completion of
work. (Approx front area = 1.20 sq M)
30 SITC of First aid box as approved by Indian red cross conforming to
31 SITC of Fire Bucket stand made of M S angle suitable for and with 4
Nos Fire Buckets of 9.5 Ltrs capacity filled with
32 NSR-149 SITC of of rubber gloves of 11 KV grade as per IS : 4770. Set 2 458.00 916.00
33 Supplying and fixing of high voltage insulation mat of class B
having 11 KV dielectric strength, 1000mm width and thickness of
2.5mm ISI approved as required including cutting to required lengths.
34.00 Supplying and fixing of high voltage insulation mat of class B
having 1.1 KV dielectric strength, 1000mm width and thickness of
2.0 mm ISI approved as required including cutting to required
Transformer and HT & LT Panel
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
35 Supply, fixing, testing & commissioning wall/floor mounted LT
panel primer coated with powder coated paint & provided with
required gasket for dust/vermin proof with degree of protection
IP42 suitable for 415Volt 3 phase, 50 Hz, 4 wire system
fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for
doors) duly compartmentalized for incomer, bus section,
outgoings, cable alleys & CT, PT Ampere Metre, Volt Metre,
NSR-152 selector switches, frequency Metre, phase indicating lamp, Kg. 250 643.00 160750.00
Energy Metre complete including cost of busbar supports,
detachable cable gland plates, 2 earthing terminals, internal
wiring & fixing of separately supplied MCBs, MCCBs, ACB,
panel mounted changeover switch/SFUs, etc. as required but
excluding cost of busbar strips, Ampere Metre, Volt Metre,
selector switch as per approved design & specification
36 Supply and fixing of LT panel accessories of approved make
NSR-153 in existing LT panel including connections etc. as required as
per specification.
Digital Ampere Metre with CTs with selector switch P.SET 1 3443.00 3443.00
Digital Volt Metre with selector switch & HRC fuse P.SET 1 3884.00 3884.00
Frequency Metre Each 1 2326.00 2326.00
Aluminium bus bar strips with PVC sleeves Kg. 87.5 460.00 40250.00
LED lamp indicator Each 3 414.00 1242.00
38 Supplying & drawing/laying of PVC insulated XLPE aerial
bunch power cable conductor H2/H4 grade aluminium
solid/stranded conforming to IS-14255- 1995, alu. alloy
insulated messenger 1100 volts grade cable of approved
make in air with necessary material as per specification of
required size as mentioned below –
Single core cable(insulated neutral messenger)
3x150 sq.mm, 1x35(st. light), 1x95(insulated neutral
39 Supplying &fixing of spring loaded busbar screwless
connector with enclosure of approved make including required
clamp, nut, bolt, connection, testing as per specification to
complete the job.
40 Supply & fixing fencing of chain link mesh 100 x 100 mm, 12
SWG GI wire for for D.P. structure electric sub-station switch
yard including single post of angle iron size 50x50x5mm, 2.5
mt long should be provided upto 2.00 mt. apart or as required.
The panel frame with required angle iron/ flat iron
members/cross members including mesh welded in frame
NSR-157 panel shall be erected between the posts. The angle iron post sq.mtr. 48 2951.00 141648.00
shall be erected in cement concrete M-15 (1:2:4) (20 mm
graded metal) foundation, including excavation of pit and
refilling the same. The fencing shall be provided with one
entrance gate including locking arrangement as required as
per specification. The height of fencing shall be 2 mt. above
ground level. Fencing shall be painted with required shade.
41 Supply & fixing of I.S.I.marked Porecelain Rewireable fuse
unit of approved make or confirming to I.S.S. 2086-1982
42 NSR-159 Painting of poles
Prima coat over new steel and other metallic surface with red Per
oxide zinc chromide paint complete with supply of material sq 70 124.00 8705.00
labour etc. including preparation of surface. meter
Prima coat with aluminium paint, brushing complete with
material and labour including preparation of surface
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
43 Supplying & installing G.I. pipe for protection of underground
cable fixed on wall/support/in trench/fixed between two rigid
existing support of wall/beam for erection of ceiling Fan/down
rod for stiff pendent for light luminaries /fan/protective for
earthing, lightening conductor down strip/overhead service
NSR-160 line/for submersible cable or centrifugal pump for water
supply with necessary iron clamp coupler, bend, tee, elbow,
nuts and bolts etc. complete in an approved manner as required
to complete excluding cost of excavation/dismantling & other
finished masonry Item complete.
For 'B' class pipe ISI marked (IS-1161- 68)
44 Supply of support for overhead line RS joist of I.S. standard
including drilling of required hole etc. complete as required.
H - Beam 152x152mm, Std weight 37.1 Kg/Mtr meter 78 4607.00 359346.00
45 Supplying and drawing all aluminium alloy conductor
(AAAC) of approved make conforming to IS 398-1979 Pt. IV,
NSR-162 including binding at existing insulator, jointing, jumpering,
tearing off, connecting etc. as required including clearing of
obstacles (if any)
AAAC 0.05 sq inch (55 sq.mm Al. EQ.)-(Rabbit) km. 0.9 99646.00 89681.00
46 Supplying and drawing guard wire/earth wire/bearer wire 13
sq mm (4mm. dia) G.I. including stringing, binding at existing
insulators or brackets, jointing, jumpering, connecting &
cradle etc. as required and clearing of obstacles (if any)
47 Supplying and drawing guard wire/earth wire/bearer wire
18.62 sq mm (4.87mm. dia/6swg) G.I. including stringing,
NSR-164 binding at existing insulators or brackets, jointing, jumpering, km. 0.6 30394.00 18236.00
connecting & cradle etc. as required and clearing of obstacles
48 Erection of RS Joist pole/'H' beam/steel tubular/steel rail pole
of length exceeding 10 metres but not exceeding 15 metres in
cement concrete M-10 (1 cement:3 core sand: 6 graded stone
aggregate 40mm nominal size) base, foundation, muffing
including excavation and back refilling etc. as required.
49 Supply, fabrication and erection of angle/channel/flat iron
fitting for overhead line & sub-station etc such as 'D' bracket,
cross arms, top clamp, 'V' cross arms, back/support clamp or
NSR-166 other similar work etc. including nut bolts of required size, kg. 250 170.00 42500.00
making holes, fabrication, welding, cutting, etc. and painting
with one coat of red oxide paint & two coat of aluminium
paint as required as per specification.
50 Supplying installing, testing & commissioning of outdoor
H.T., AB switch assembly set gang operated with brass contact
parts, including required GI pipe operating rod, handle &
NSR-167 locking arrangement on On-Off position conforming to IS
complete with required material and installing on existing DP
structure to complete the job as required as per
specification.(Set of 3 nos.)
51 Supplying installing, testing & commissioning D.O. fuse
assembly with brass part contact for 33 or 11/0.4 KV DP
NSR-168 Structure set of 3 Nos. with fuse barrel i/c required fuse
element & other materials as per specification on existing D.P.
structure as required.
S. No. Description Unit Quantity Rate (In Rs) Amount (In Rs)
52 Supply & fixing anti climbing device with 2 ply G.I. barbed
NSR-169 wire 1 Kg. per pole complete as per MPMKVVCO. each 4 374.00 1496.00
53 Supply, laying and fixing of G.I. earth coil of 4mm dia G.I.
wire having 120 turns of nearly 50mm dia. and 3 mt. long tail
in existing pit duly earthed with pole etc complete as required
as per specification.
54 Supply of H.T. Cable
Supply & Testing of following 11 KV( UE) grade multicore
Aluminium conductor XLPE insulated cable, insulation screening
with extruded semi conducting compound in combination with
NSR-171 copper tape armoured cores laid up, inner sheath of PVC tape,
galvanised steel flat strip armoured and overall PVC sheathed cable
conforming to IS: 7098 (Part - II) and complete with all latest
amendments etc. complete as required.
55 Supply Of L.T. Cable:
Supply of XLPE insulated power cable (conforming IS-7098
NSR-172 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI
marked with alu. stranded /solid conductor
Unarmoured 1 core
56 Supplying of Following Sizes of 1.1 kV Grade Multicore
Aluminium Conductor XLPE Power Cable Insulated armoured cable
NSR-173 conforming to IS:7098 (Part - I) or as per Relevant IS Code complete
with all Amendments etc and should be NABL certified as required.
NSR-174 3.5 C X 300 Sq.mm Al. XLPE arm. Metre 110 2,555.00 2,81,050.00
NSR-175 3.5 C X 150 Sq.mm Al. XLPE arm. Metre 60 1,288.00 77,280.00
TOATAL DSR ITEMS 10,83,051.00
TOTAL NON DSR ITEMS 18,96,019.00
TOTAL DSR + NON DSR ITEMS 29,79,070.00
Name of PROPOSED CONSTRUCTION OF INSTITUTE OF CHARTERED ACCOUNTANTS OF INDIA AT, DISTRICT-
Project:- GWALIOR (M.P.)
S.No. of Project Sub Head :- 1
S.No. of Component :- D
Name of Component :- MOTORIZZED STEEL GATES
S.No. DSR 2022 Description of Item Unit Quantity Rate Amount
Supply, installation, testing and commissioning of motorized steel EACH
sliding/swing gate up to 6.0 m clear width, fabricated from heavy duty MS
hollow sections with sufficient stiffeners, including suitable guide
rails/hinges, rollers, foundation frame, and primer + enamel paint finish,
1 NSR-176 complete with electro-mechanical motor drive unit, control panel, limit 2 5,40,000.00 10,80,000.00
switches, safety photocell sensors, push button operation, remote/manual
override mechanism in case of power failure, interlocking provision,
required cabling, earthing and all civil foundation works, as per approved
drawing and specifications, complete in all respects.
NON DSR TOTAL 1080000
TOTAL COST 1080000
Name of work : Proposed Construction of Institute of Chartered Accountants of India At District- Gwalior(M.P.)
Sno Items Qty Unit Price Total Price
Office table with ERU T 25 (1800 W X 750D X
750H with Pedeat
NSR-178 High Back Rev Chair - Trill 1 13621 13621
Visitor chair Relex Sledge base without Arm
NSR-180 Sofaset 3 seatr Bobbin 2 29211 58421
NSR-181 Coffee Table Travit ( 1100X600) 1 10872 10872
NSR-182 Corner table Travit 1 7538 7538
NSR-183 Storwel Plain 2 33808 67616
Office table with ERU T 25
NSR-185 High Back Rev Chair - Trill 1 13621 13621
NSR-186 Visitor chair Relex Sledge base without Arm 2 6463 12925
NSR-187 Storwel Plain 1 33808 33808
Chairman's Office
NSR-188 Executive Table Aristo 1800X2100 1 119992 119992
NSR-189 Executive Chair - High Back Trill LC 1 25050 25050
NSR-190 Executive Visitor Chair-Trill 3 8553 25658
NSR-191 Sofaset 3 seatr Vertex 1 42402 42402
NSR-192 Coffee table Reason 1 11307 11307
NSR-193 Executive Table Aristo 1650X1950 1 119992 119992
NSR-194 Executive Chair - High Back Trill LC 1 25050 25050
NSR-195 Visitor Chair-Trill 2 8553 17106
NSR-196 Sofaset Tyrant SLthr (3+1+1) 2 62334 124668
NSR-197 Corner table Travit 2 7538 15076
NSR-198 Coffee Table Travit 2 10872 21744
NSR-199 Visitor chair Relex Sledge base with Arm 40 7455 298210
Multipurpose Hall
NSR-200 Visitor chair with arm Brovo 160 11005 1760762
NSR-201 Sofaset 3 seatr Bobbin 1 29211 29211
NSR-202 Sofaset 1 seatr Bobbin 2 20096 40192
NSR-203 Coffee table Travit 1 7538 7538
NSR-204 Storwel Plain 4 33808 135233
NSR-205 10 seater Table Mingle Laminate 1 55801 55801
NSR-206 Bravo mid back rev chair with arm 10 14534 145336
Conference Hall
NSR-207 14 seater Table Mingle Laminate 1 105623 105623
NSR-208 Bravo mid back 12 14534 174403
NSR-209 Trill Mesh full back with Headrest 2 15735 31469
NSR-210 Reading Table Insight 1800X900 5 20904 104518
NSR-211 Visitor chair Relex Sledge base without Arm 30 6463 193878
Radaince Stell bookrack - Wall sided
Desk cum bench - 2 seater Genii
NSR-214 Visitor chauir Relex Sledge base with Arm 3 7455 22366
NSR-217 Visitor chair Relex Sledge base without Arm 1 6463 6463
NSR-218 Single bed with mattress 1 31868 31868
Covered Terrace
NSR-219 Timeout 4 seater PU coated 2 30863 61727
NSR-220 Chair Shine Univ MS 8 3467 27733
Name of work : Proposed Construction of Institute of Chartered Accountants of India At District- Gwalior(M.P.)
S. No. Description Unit Rate (In Rs) Amount (In Rs)
Supplying, carving, and installing Maa Saraswati
Statue made of premium quality white Makrana
marble or equivalent approved marble, statue height
5’-0” to 6’-0” (excluding pedestal), hand-carved with
fine detailing, smooth finishing, and polished surface
23.0 NSR-121 as per approved design/drawing. The statue shall be 1.00 1.00 10,00,000.00 10,00,000.00
mounted on a marble pedestal of 1.20 m height, with
fascia finished in approved shade of granite,
including moulding, edge finishing, and proper
anchoring to the foundation in PCC (1:3:6) or as
directed by the Engineer-in-Charge. The work
includes all materials, skilled labor, tools, machinery,
transportation, lifting, fixing in position with stainless
steel dowels and epoxy grout, polishing, protective
coating, cleaning, and disposal of debris, complete in
all respects as per direction of Engineer-in-Charge.
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT.pdf
Tender Document
furniture Specification .pdf
Tender Document
SCC.pdf
Tender Document
MAKE list.pdf
Tender Document
Drawings of ICAI.pdf
Tender Document
boq ICAI.pdf
Tender Document
GCC_PMC_Contracting_2022 with AMENDMENT .pdf
Tender Document
addendum-d58a866161bd-Corrigendum Addendum No 01.pdf
pdf • 0.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .