Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.2 LAccepted-AOC 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | ₹60.2 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹64.1 L+₹4.0 L (6.60%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹64.1 L+₹4.0 L (6.60%) | L2 | Rejected-Finance Other than being lowest |
| 3 | L3₹66.8 L+₹6.6 L (11.0%)Rejected-Finance | ₹66.8 L+₹6.6 L (11.0%) | L3 | Rejected-Finance Other than being lowest |
| 4 | L4₹69.5 L+₹9.3 L (15.5%)Rejected-Finance | ₹69.5 L+₹9.3 L (15.5%) | L4 | Rejected-Finance Other than being lowest |
| 5 | L5₹71.9 L+₹11.7 L (19.5%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹71.9 L+₹11.7 L (19.5%) | L5 | Rejected-Finance Other than being lowest |
Tender Value
₹65 L
EMD Value
₹1.2 L
Closing Date
13 Apr 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
PROVISION OF AUTO FIRE DETECTION SYSTEM (AFDS) FOR BUILDING 154, 158, 167 AND DDB ROOMS AT NAVAL DOCKYARD AND PROVISION OF AUTOMATIC FIRE DETECTION AND FIRE FIGHTING SYSTEM AT SHIPS MAGAZINE, INS KUNJALI UNDER GE (NW) KUNJALI, COLABA, MUMBAI
2024_MES_645957_1
8330/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) Kunjali
Class C
category c (vi)
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) Kunjali
₹1.2 L
Yes
30 May 2024
11 Mar 2024
15 Apr 2024
11 Mar 2024
13 Apr 2024
1 Apr 2024
11 Mar 2024 - 30 Mar 2024
Amount
Supplying installation, testing & commissioning Microprocessor based 2 loop capacity ,Networkable analogue addressable type fire alarm control panel with min.600 character LCD display, The panel should be equipped with sufficient numbers of 1 loop with up to 10 to 15% spare capacity with each loop shall have a capacity of minimum 99 detectors and 99 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. and panels shall have provision of intigraton with BMS System.(UL/EN Approved) as per tender specificaiton.Panel shall be integrated with respective to the zoning of PA System so that incase of fire PA System shall automatically come in announcement mode complete as per manufacturers instructions
Supplying installation, testing & commissioning landline fire alarm auto dialer with sms and Memory available to Store 10 Phone Numbers dialling facility to reach the fire brigade to get the intimation about the location of the area Builtin Emergency Speech Dialer with 8 Numbers & 1/ 2 Messages,NO/NC contacts for both fire and fault, Automatic changeover arrangement to standby supply with battery charger with low battery indication,Fault/ failure indication such as mains fail, short, open, Battery fail etc,Micro-Controller Based System,Both Dialling Modes Can Be Used (Pulse/Tone),Recorded Message Playback Speaker Provision Available complete all as manufacturers instructions and as directed.
Supplying installation, Testing & Commissioning of Microprocessor based Repeater Networkable analogue addressable type fire alarm control panel with min.600 character LCD display,Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. and panels shall have provision of intigraton with BMS System.(UL/EN Approved) as per tender specificaiton.Panel shall be integrated with respective to the zoning of PA System so that incase of fire so PA System shall automatically come in announcement mode complete all as specified and as directed.
Supply, Installation, testing and commissioning addressable Manual call point (Pull down/Break Glass Type). The device shall have an LED which shall blink in normal state and get steady on activation to monitor the health status of the device and shall be underwritters laboratories listed, semi flush type complete all as manufacturers instructions and directed.
Supply, installation, testing & commissioning Addressable monitor modules for Sprinkler Flow Switch and Door Holders all as per manufacturers specification and as directed.
Supply, installation, testing & commissioning addressable electronic hooter with built in amplifier unit with two tone generator of 100 meter range complete all as per manufacturers specification and as directed.
Supply, installation, testing & commissioning Analog addressable Multi Criteria (Optical + thermal) detector with mounting based LED for AFC(Above Celling & below celling .) complete all as per manufacturers specification and as directed.
Supply, installation, testing & commissioning Conventional Beam detector required for hall & indoor open area complete all as per manufacturers specification and as directed.
Supply, installation, testing & commissioning Addressable control modules for AHU, Access control Integration & stairs Pressurization Fan Hooters / Sounders / Strobes complete all as per manufacturers specification and as directed.
Supply and fix fault isolator module with automatic resetting arrangement complete all as per manufacturers specification and as directed.
Supply & laying PVC FRLS armoured cable 1.5 sqmm solid copper conductor 4 core, XLPE Insulated, Extruded PVC sheathed, galvanized steel strip, electric power cables (heavy duty) 1100 Volts grade, laid in duct / along pole/wall complete all as specified and directed. Note : The cost of Aluminium thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it.
Supply, installation, testing & commissioning Response indicator for Above ceiling detectors & Cabin Detectors complete all as per manufacturers specification and as directed.
Supply, installation, testing & commissioning GUI based main network software must be capable of graphically representing each facility being monitored with floor plans and icons depicting the actual locations of the various systems; and / or sensors’locations. The GUI software shall be located in control room in one of the blocks and shall monitor all the blocks panel connected with each other complete all as per manufacturers specification and as directed.
Supply and fixing MS ERW flanged pipe 100mm NB heavy duty for multi storied building duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
Supply, installation, testing & commissioning Electric Driven Jockey pump horizontal end suction centrifugal type Conforming to IS- 12469:1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with nonover loading power characteristics for frequent start / stop operations for 440 V , 3 phase, 50 Hz, 70 mtr head 180 LPM discharge including suction line and suction valve complete all as per manufacturers specifications and as directed.
Supply, installation, testing & commissioning Fire pump diesel engine driven horizontal end suction, centrifugal type conforming to IS- 12469 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 phase, 50 Hz, AC supply, 70 mtr Head, 1620 LPM discharge complete all as per manufacturers specifications and as directed.
Supply and fixing MS ERW flanged pipe 150mm NB heavy duty for multi storied building duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
Supply and fixing Sprinkler glass bulb type (Standard response) conforming to IS:15105/TAC guidelines 79 degree temperature rating pendent type complete all as per manufacturers specifications and as directed.
Supply and fixing MS ERW flanged pipe 50mm NB heavy duty for multi storied building duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
Supply & fix gun metal fire hydrant landing valve type A (single head outlet) of 63 mm dia conforming to IS 5290 complete all as specified.
Supply and fixing Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses, lock, 2 keys and a break glass, recess for keys, and door frame made of 16 gauge MS sheet duly painted with two coats of synthetic enamel paint (fire red out side and brilliant white inside yard ) over a coat of red oxide zinc chrome primer complete all as specified.
Supply and fixing 63 mm dia gun metal branch pipe with 12.5 mm nozzle conforming to IS 903 complete all as specified.
Supply and fixing 63 mm dia 30 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903 complete all as specified.
Supply and fixing 100mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set complete all as specified.
Supply and fixing 150mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set complete all as specified.
Supply and fixing 3 phase Star delta starter suitable for motor 180 LPM above 70 meter head upto 90 meter head complete all as specified.
Supply and fixing non return valve 80 mm bore (Wafer Type slim ) complete all as specified
Supply and fixing cast iron sluice valve 150 mm bore Class PN 1.6 complete all as specified
Supply and fixing Fire brigade inlet connection 2way complete all as specified and directed
Supply & fixing fire alarm control panel complying with BE EN 54-5 loop with 99 detectors & 99 Modulas & upto 200 dectors and modules (per each loop)
Supply & fixing Detectors complying with and type certified to EN -45 Addrssable type multi senser detector photoelectric/Optical with base self built intellgence conforming to IS:11360 complete all as specified.
Supply & fixing addressable manual call point resettable type complete all as specified.
Supply & fixing addressable electronic sounder cum srobe complete all as specified.
Supply & fixing remote response indicators complete all as specified.
Supply, fixing test & commissioning 2 core x 1.5 sqmm. multistranded copper conductor cable, FRLS, armoured fixed on wall/ceiling/loop using proper clamp/clips complete all as specified and directed.
Supply and fixing Cable glands suitable for 2 core 1.5 Sq copper conductor armoured cable complete all as specified and directed.
Supply & fixing juction box.
Supply & fixing Addressable control module.
supply & fixing Addressable monitor module.
Supply and fixing Beam Master Detector, Transceiver Type (Add power supply unit & module)
Supply & fixing fire alarm sounders/sirns electronic type horizontal single stage continous normal operation for atleased 50 mintues with sound level of 65 db to 12 db measured at 1.5m with sound output variation of +5DB 1000 m range.
Supply and fixing ECO fore Automatic Modular ABC Powder type fire extinguiser complete all as specified
Darpan Construction
Shetty Construction Co
Nexus Infratech
Shree Ayyappa Engineering
Precision Safety Equipment Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .