| 1.00 | Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator inbuilt complete with emitter and receiver including connections with remote test features etc. complete as required. | 10 | Each | 92,400 ₹9.2 L | 95,650 ₹9.6 L |
| 2.00Supplying, installation, testing & commissioning of following capacity at full load (Unity Power Factor) ONLINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)’s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e., kw rating of the UPS shall be KVA rating x 1) however UPS shall be suitable to take load at 0.7 lagging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. | |||||
| 2.01 | 2 KVA | 1 | Each | 42,000 ₹42,000 | 41,000 ₹41,000 |
| 3.00 | Supply and drawing of 2C x 1.5 Sq.mm FRLS PVC insulated, sheathed copper conductor cable, single core cable in the existing surface /recessed steel/PVC conduit as required. | 90 | Mtr | 180 ₹16,200 | 195 ₹17,550 |
| 4.00 | Supplying and fixing of medium class 20 MM PVC Conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | 300 | Mtr | 130 ₹39,000 | 165 ₹49,500 |
| 5.00 | Supply and drawing of flexible Twin core 1.5 Sq.mm FRLS PVC insulated, Overall shielded along with PVC outer sheath instrumentation unarmored copper conductor cable, in the existing surface /recessed steel/PVC conduit as required. | 232 | Mtr | 300 ₹69,600 | 350 ₹81,200 |
Updated dates
Tender Value
₹10.4 L
EMD Value
₹31,278
Closing Date
17 Dec 2025, 5:30 pmClosed
Sr. Manager (E-E)
AAI, Imphal International Airport, Imphal - 795140.
Provision of FDA - Beam Detector, for New Integrated Cargo Terminal Building at Imphal International Airport
2025_AAI_255110_1
AAI/IMP/ENGG-ELECT/Cargo FDA/2025-26
Open Tender
Electrical Works
45 days
Imphal
As per NIT
13 documents required · 13 mandatory
₹1,180
₹31,278
Imphal
7 Jan 2026
12 Nov 2025
18 Dec 2025
12 Nov 2025
17 Dec 2025
12 Nov 2025
12 Nov 2025 - 19 Nov 2025
19 Nov 2025
Amount
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator inbuilt complete with emitter and receiver including connections with remote test features etc. complete as required.
Supplying, installation, testing & commissioning of following capacity at full load (Unity Power Factor) ONLINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)’s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e., kw rating of the UPS shall be KVA rating x 1) however UPS shall be suitable to take load at 0.7 lagging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute.
Supply and drawing of 2C x 1.5 Sq.mm FRLS PVC insulated, sheathed copper conductor cable, single core cable in the existing surface /recessed steel/PVC conduit as required.
Supplying and fixing of medium class 20 MM PVC Conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supply and drawing of flexible Twin core 1.5 Sq.mm FRLS PVC insulated, Overall shielded along with PVC outer sheath instrumentation unarmored copper conductor cable, in the existing surface /recessed steel/PVC conduit as required.
thangtech global infra pvt ltd (BID ID -943472)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
TenderDoc.pdf
Tender Documents • 19.53 MB
BOQ_293883.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid