Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹3.9 L
Closing Date
28 Mar 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical SKIMS
SKIMS Soura Srinagar
Electrification of Newly Constructed Bath Room and Extension of Blood Bank Block near OPD at SKIMS Soura
2022_SKIMS_164778_1
eNIT NO.SIMS/HEE/E/ET/51 of 2021-22 Dt. 15-03-2022
Open Tender
Electrical Works
Item Rate
30 days
SKIMS Soura
Please refer Tender documents.
8 documents required · 8 mandatory
₹200
Yes
As Described in SBD
Exempted
28 Apr 2022
17 Mar 2022
29 Mar 2022
17 Mar 2022
28 Mar 2022
17 Mar 2022
270 days
Amount
Only Wiring to be laid for the Lighting Point through existing PVC Conduit of 25mm dia., using multi-stranded 3x1.5mm sq. PVC Insulated FRLS copper wire (P+N+E) to be fitted on 3mm Bakelite sheet suitable size,M.S. box, rowel plugs & screws etc. complete Point (excluding the cost of the switch and M.S. Box and bakalite sheet). 3x1.5 mmsq.
Only Wiring to be laid for the Heating/Power Point through existing PVC Conduit of 2.5mm dia., using multi-stranded 3x2.5mm sq. PVC Insulated FRLS copper wire (P+N+E) to be fitted on 3mm Bakelite sheet suitable size,M.S. box, rowel plugs & screws etc. complete Point (excluding the cost of the switch and M.S. Box). 3x2.5 mmsq.
Supplying and Fixing of Piano Type switch / socket and switch box including connections as required
5A switch
5A socket outlet (3/5 pin type)
Fan Dimmer stepper type, 2 way
15/16A switch
6pin 15/16A socket outlet
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
150 mm X 75 mm X 60 mm deep
150 mm X 150 mm X 60 mm deep
180 mm X 100 mm X 60 mm deep
200 mm X 150 mm X 60 mm deep
Providing and fixing of following size medium class PVC conduit 2mm thick along with accessories
25 mm dia surfaced manner
25 mm dia recess manner
Wiring to be laid for the Lighting Circuit through existing PVC Conduit of 25mm dia., using multi-stranded 3x2.5mm sq. PVC Insulated FRLS copper wire (P+N+E)
Sub Main Line for the lighting Points (from DB to Panel) through existing PVC Conduit of 25mm dia., using multi-stranded 3x4mm sq. PVC Insulated FRLS copper wire (P+N+E)
Sub Main Line for the Heating Points (from DB to Panel) through existing PVC Conduit of 25mm dia., using multi-stranded 3x4mm sq. PVC Insulated FRLS copper wire (P+N+E)
Sub Main Line for the AC/Heating/Power Points (from DB to Panel) through existing PVC Conduit of 25mm dia., using multi-stranded 6x10mm sq. PVC Insulated FRLS copper wire (P+N+E), where-ever required
Providing fixing of 4feet long LED baton 6000/6500K, Al Body with anti glare difuser with energy efficient electronic driver, CRI>= 80, min. lumens 2000, with max wattage of 20W including connection with multistrand copper wire 3 core cable etc as reqd at site, with surge protection of 2KV or more, Burning Hours >=50,000 Hours.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
MCB single pole 6A to 32A
MCB double pole 40A
Supplying and fixing of following way, SPN sheet steel, MCB distribution board, 220 volts, on surface/recess, complete with tinned copper insulated bus bar, neutral bus bar, earth bar, din bar , interconnections, powder painted including earthing etc as reqd
SPN 12 way
SITC of Exhuast Fan along with 300mm Bird Guard to protect fan in running condition, double ball bearing with heavy duty motor rated speed 1400rpm, rated voltage 220-240V, Air delivery 1600Mhr/min., 250mm
Making of holes for installing of exhaust fans and p/f of wooden frames of various sizes. Complete with civil works in all respects. 12"
SITC of Ceiling fan 1200 mm Sweep copper wound heavy duty, with brush less direct cuurent (BLDC) Motor class of insulation B, 3 no. blades, 30 cm long rod 2 no. canopies shackle kit safety rop, power factor not less than 0.9, sevice value (CMM/W) min. 6.85, Air delivery min. 215CMM, 350 rpm (Tolerence as per IS:374-2019) THD <10%, and all remaining accessories including safety pin, nut bolts, washers, Temp. rise 75 deg. C (Max.), insulation resistance >2 MΩ, suitable for 230V, 50HZ, single Phase AC, earthing etc. complete as reqired.
Supply, Installation testing & commissioning of 50 Litre capacity Heater/Geyser with: 1. Energy saving 5 Star certification by BEE 2. Provision for Temp. regulation by means of external knob. 3. Power rating 220/230V, 50Hz, single phase. 4. Max. rated pressure 8 Bar 5. Installation type Vertical/Horizontal as per site requirement. 6. Body Type: rust /water proof & shock proofourt body with attractve looks and crrosion resistant inner tank made of cold rolled steel, resistant to hard water. 7. Element type: Glass coated heating element to prevent from corrosion and hard water, 8. Safety valve pressure 8 Bar max. 9. Energy efficiency feature: should be have high density PUF Insulation for Energy saving. 10. Anti syphon system to prevent back flow of water. 11. Should have indicationg lamps for ON & CUT OFF. 12. Confirming to IS 2082:2018, IS 302-2-21
Supplying and Fixing of 240V, SPN industrial type, Socket outlet, with 2 pole and earth , metal enclosed plug top, in sheet steel enclosure , on surface or in recess, with chaine dmetal cover for the socket outlet and complete with connections, trsting and commisioning etc. as reqd., alongwith 20A C curve SP MCB,
Providing and fixing of bakelite /Phenolic Laminated Sheet 3 mm thick of different sizes.(Hylum/Formica make)
SITC of surface/recess mounted, vertical type 415V TPN MCB Distribution board of sheet steel, dust protected, duly powd painted, inclusive 200A Tinned Copper Bus Bar, common Neutral Link, earth bar, Din bar for mounting MCBs (Without MCB and Incommer) as required: 4 Way (Double Door)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
63 A, 25 KA,FPMCCB 1no.
Providing and fixing following rating and breaking capacity and pole MCB TP, 415V, 50Hz, 10KA with thermomagnetic release in existing Distribution board, making connections, etc. as required.
Earthing (UL listed Maintenance free Copper Coated Earth Rod 3 Meter) Making of earthing point of Maintenance free Copper Coated Earth Rod 3 Meter, caged in 4 inch GI pipe class A in CCM compound and 10 feet Deep, as earthing electrode . The pit is to be dug using borewell and covered with 10''x10'' inch manhole cover .
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
I S F Engineers Pvt. Ltd.
M.Y. ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .