Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC AT AMRITPUR PO NB CHILKA VIA BALUGAON DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹12.5 L+₹2.7 L (27.8%)Rejected-Finance AT BRAJARAJPUR PO INS CHILKA DISTT KHURDHA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹1.3 Cr+₹1.2 Cr (1259.2%)Rejected-Finance AT NUAGARH PO BARKUL DISTT KHURDHA ODISHA 752030 | KHORDHA | ODISHA | 752030 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹13.4 L+₹3.6 L (36.3%)Rejected-Finance AMRITPUR PO INS CHILKA DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹14.6 L+₹4.8 L (49.0%)Rejected-Finance AT BARIMAL PO HATIBARI PS SUKINDA DIST JAJPUR PIN 755018 | JAJAPUR | ODISHA | 755018 | L5 | Rejected-Finance Being not lowest |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
2 Jul 2020, 6:00 pmClosed
Garrison Engineer Chilka
Garrison Engineer Chilka INS Chilka Post Khordha Dist Odisha 752037
REPAIR REPLACEMENT AND MAINT OF INTERNAL WIRING LIGHT FITTINGS MCBs DBs AND OTHER ACCESSORIES IN SAILORS CIVILIAN MD ACCNS AND SOLAPOKHARI AREA AT INS CHILKA UNDER GE CHILKA
2020_MES_344482_1
GE/CHL/8648 OF 2020-21
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Chilka
MES enlisted contractor of class E and category b i
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Chilka
₹34,000
Yes
30 Sept 2020
13 May 2020
9 Jul 2020
13 May 2020
2 Jul 2020
27 May 2020
13 May 2020 - 20 May 2020
Amount
Taking down carefully copper/ aluminium point wiring for light, fan, socket or power point complete with fittings such as switches, fan regulators, light fittings, ceilling rose, holders etc and including making good the disturbed surface on walls, floor etc complete all as specified and as directed.
M & L for point wiring with PVC FRLS insulated unsheathed multi stranded copper conductor cable of size 1.5 sqmm drawn through in including PVC casing & caping (ISI Marked) not less than 20mm wide with all accessories including 1.5 sqmm copper conductor FRLS cable for earth continuity conductor of green colour for one light point, fan/ exhaust fan point, one 5/6 Amp socket outlet controlled by one 5/6 Amps one way switch, complete all as specified and as directed. Note:- Unserviceable hylem sheet and MS sunken boxes/PVC boxes will be replaced as per site requirement and same shall be measured and paid seperatly under relevant items.
All as per item No 2 above but, one socket outlet, three pin, 5/6 Amp on the same board with other switches complete all as specified and as directed.
All as per item No 2 above but for one light point controlled by two 5/6 Amps two way switch complete all as specified and as directed.
All as per item No 2 above but, one bell point controlled by one bell push complete all as specified and as directed.
All as per item No. 2 here-in-before but for 15/16Amp socket out let, independent with 2.5 sqmm copper cable of PVC FRLS insulated, unsheathed, multi stranded and 1.5 sqmm copper conductor cable FRLS as earth continuity conductor of green colour complete all as specified and as directed.
S&F switch paino, flush type, single pole, one way, 5/6 Amp, complete all as specified and as directed.
S&F bell push, flush type, 5 Amp, 230Volt, complete all as specified and as directed.
S&F bell, AC 230 volts complete all as specified and as directed.
S&F ceiling rose,3 phase PVC/polycarbonate , isolated body complete all as specified and as directed.
S&F switch socket combination 2 pin & 3 pin 5 Amp, 230 volt, multipurpose, complete all as specified and as directed.
S&F switch socket combination 5 in 1 type, 3 pin 5 / 15 Amp, 230 volt, multipurpose, complete all as specified and as directed.
S&F stepped type electronic fan regulator for ceiling fan of any sweep including necessary connection complete all as specified and as directed.
S&F switch paino, flush type, single pole, two way, 5/6 Amp, complete all as specified and as directed.
S&F in replacement of factory made sheet metal single pole and neutral enclosure with 2 pin and earth plug and socket with one MCB SP, 240 volt, 20 Amps complete all as specified and as directed.
S&F in replacement of 1X18 Watt indoor type retrofit batten type luminaries complete with LED retrofit T8 polycarbonate tube of capacity 18 Watt with decorative holder including connection with three core twisted flexible copper conductor cable of suitable size upto ceiling rose complete all as specified and as directed. Make :- Havells Cat Part No. REGALBATTENT8UPTO1X22WDSBSWH (Batten) and PHOTONULTRA 2.01213T8SSTL18WLED865SPC(LED Lamp) or Wipro Cat Part No.W10921208 (Batten / Channel ) & LL13-181-65SE(LED Lamp) or Bajaj cat part No for Batten :BLRB-DB118 &Tube : BLRB 18W CW or Philips Cat Part No.BN550WLED20-3000 as approved.
S&F in replacement 1X9/10 Watt indoor batten type luminaries decorative ultra slim linear LED lighting fixture with extruded polycarbonate complete with LED tube of capacity 9/10 Watt with decorative holder and end cap and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and as directed. Make :- Havells Cat Part No : LUMILINEBS9WLED830SPCWH or Bajaj Cat Part No BCLSB 10 NW or Philips Cat Part No BN550WLED12-3000 as approved
S&F in replacement of 10 Watt LED Bulk Head fitting Environmenatal friendly, ultra morden, energy saving, surface mounted, decorative oval bulk head edge- lit LED luminaries comprising of high brightness LEDs complete all as specified and as directed. Make:- Bajaj Cat Part No BIBWP10WLED (Product code 112334) or Crompto greaves Cat part No LBHP-10-CDL or Havells Cat Part No.HEXAFT10WLED857SSYMBOPC as approved.
S&F in replacement of 20 W tubelight fitting with lamp, Endura linear LED wall mounted LED batten with polycarbonate housing & integrated driver for efficient heat dissipation with complete fitting complete all as specified and as directed. Make:- Havells Cat part No LUMILINEBS 20WLED830SPCWH or Bajaj Cat part No. BCLSB 20 WH
S&F in replacement 18 Watt T-8 LED retrofit tubelight to existing fitting complete all as specified and as directed. Make :- Havells Cat part No PHOTONULTRA 2.0 1213T8SSTL18WLED865SPC (LED Lamp) or Bajaj Cat Part No BLRB18W CW or Wipro Cat part No : LL13-181-65SE(LED Lamp)
S&F in replacement of Factory made sheet metal enclosure single pole and neutral , 240 volt, 8 Way with 200 amp rated bus bar, IP-42 protection , double door fixed to wall complete all as specified and as directed. Make:- C&S/Standard/Havells
S&F in replacement of Factory made sheet metal enclosure single pole and neutral , 240 volt, 4 Way with 200 amp rated bus bar, IP-42 protection , single door fixed to wall complete all as specified and as directed. Make:- C&S/Standard/Havells
S&F in replacement of Factory made sheet metal enclosure triple pole and neutral , 240 volt, 4 Way with 200 amp rated bus bar, IP-42 protection , double door fixed to wall complete all as specified and as directed. Make:- C&S/Standard/Havells
S&F replacement of MCB 6 to 32 Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified and as directed. Make:- C&S/Standard/Havells.
S&F in replacement of MCB 32 Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, complete all as specified and as directed. Make- C&S/Standard/Havells.
S&F in replacement MCB 63 Amp, 415 Volt, TPN, breaking capacity 10 KA 'C' series, complete all as specified and as directed. Make- C&S/Standard/Havells.
Taking down and re-fixing of existing hanging conduit wiring with proper saddles, complete all as specified and as directed.
S&F 3mm thick laminated sheet (ISI Marked) of size 9 inch X11 inch with 4 Nos of screws and washers complete all as specified and as directed.
S&F 3mm thick laminated sheet (ISI Marked) of size 5 inch X7 inch with 4 Nos of screws and washers complete all as specified and as directed.
S&F 3mm thick laminated sheet (ISI Marked) of size 5 inch X5 inch with 4 Nos of screws and washers complete all as specified and as directed.
S&F mild steel sunken box made out of 1.6mm thick mild steel sheet of size 8 inch x 10 inch including taking down the existing sunken box and making good to match the existing surface complete all as specified and as directed.
S&F mild steel sunken box made out of 1.6mm thick mild steel sheet of size 4 inch x 6 inch including taking down the existing sunken box and making good to match the existing surface complete all as specified and as directed.
S&F mild steel sunken box made out of 1.6mm thick mild steel sheet of size 4 inch x 4 inch including taking down the existing sunken box and making good to match the existing surface complete all as specified and as directed.
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-2009, connected to earthing with DBs all as specified including excavation and earth work in any type of soil, PCC 1:3:6 type C-1 using 20mm graded stone aggregate in chamber & 40mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slab, reinforced, with 8mm dia TMT bar at 150mm c/c both ways, 15mm dia GI pipe light grade for earth lead protection, 20mm dia GI medium grade pipe for watering , water funnel etc complete all as specified and testing on completion.
M&L for earth continuity conductor 4mm dia galvanised iron or steel earth wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or other indicated situation for loop earthing etc as required complete all as specified and as directed.
M&L for earth continuity conductor 6 mm dia copper earth wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or other indicated situation for loop earthing etc as required complete all as specified and as directed.
S&F sub main wiring with two runs of 4.0 sqmm PVC FRLS sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 sqmm PVC FRLS drawn through existing PVC conduit/ steel conduit, complete all as specified and as directed. Note:- 2 run of 4 sqmm copper cable and one run of 4 sqmm copper earth wire shall be measured as one unit length.
S&F sub main wiring with two runs of 6.0 sqmm PVC FRLS sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 6.0 sqmm PVC FRLS drawn through existing PVC conduit/steel conduit, complete all as specified and as directed. Note:- 2 runs of 6 sqmm copper cable and one run of 6 sqmm copper earth wire shall be measured as one unit length.
S&F of sub main wiring with two runs of 4.0 sqmm PVC FRLS sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 sqmm PVC FRLS drawn in and including PVC casing and caping not less than 20mm wide complete all as specified and as directed. Note:- 2 run of 4 sqmm copper cable, 1 run of 4 sqmm copper earth wire and PVC casing and caping shall be measured as one unit length.
S&F of sub main wiring with two runs of 6.0 sqmm PVC FRLS sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 6 sqmm PVC FRLS drawn in and including PVC casing and caping not less than 20mm wide complete all as specified and as directed. Note:- 2 runs of 6 sqmm copper cable, one run of 6 sqmm copper earth wire and PVC casing and caping shall be measured as one unit length.
Taking down existing lamp fitting of any type and refixing the same including provision for copper cable of suitable size from celling rose to fitting, complete all as specified and as directed.
S&F in switch piano, flush type, single pole one way 15 amp complete all as specified and as directed.
S&F in replacement LED street light 25W, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 complete all as specified and as directed. Make:- Bajaj Cat Part No.BRLEP 25W LED WH(product code 169826) or Havells Cat Part No.ENDURAPEARLSL25WLED757SASYTOPC as approved.
S&F in replacement switch paino, flush type, single pole, one way, 5/6 Amp, complete all as specified and as directed.
S&F in replacement ceiling rose,3 phase PVC/polycarbonate , isolated body complete all as specified and as directed.
S&F in replacement of bell push, 5 Amp, 230Volt, complete all as specified and as directed.
S&F in replacement of bell electric, AC, 230 volts, complete all as specified and as directed.
S&F in replacement of stepped type electronic fan regulator for ceiling fan of any sweep including connection with three core flexible PVC copper conductor of size 1.5 sqmm, complete all as specified and as directed.
S&F in replacement switch socket combination 2 pin & 3 pin 5 Amp, 230 volt, multipurpose, complete all as specified and as directed.
S&F in replacement switch socket combination 5 in 1 type, 3 pin 5 / 16 amp, 230 volt, multipurpose complete all as specified and as directed.
S&F in replacement of switch paino, flush type, single pole, two way, 5/6 amp, complete all as specified and as directed.
S&F in replacement of sub main wiring with Four run of 6.00 sqmm PVC FRLS sheathed, copper conductor cable, 1100 Volt, and two runs of copper earth wire 4.0 sqmm PVC FRLS drawn through PVC casing and caping, complete all as specified and as directed. Note:- 4 run of 6 sqmm cable and two run of 4 sqmm copper earth wire shall be measured as one unit length.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to end or edges for concealed conduit wiring etc. and making good, cutting not exc 10 cm girth complete all as specified and as directed.
S&F 32mm external dia of rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed.
S&F 25mm external dia of rigid non-metallic PVC conduit of exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed.
S&F 25mm external dia of rigid steel conduit stove enamelled exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed.
S&F round dummy plate for electric wiring junctions, complete all as specified and as directed.
S&F PVC rectangular block for mounting, switches, sockets, fan regurators etc with box of size 100mm x 100mm x 50mm, complete all as specified and as directed.
S&F PVC rectangular block for mounting, switches, sockets, fan regurators etc with box of size 175mm x 100mm x 50mm complete all as specified and as directed.
S&F in replacement of LED retrofit lamp B22 holder base with polycarbonate body and aluminium heat sink of 09/10W complete all as specified and as directed. Make:- Bajaj/Havells/Philips
S&F in replacement angle holder for LED bulb of any type complete all as specified and as directed.
Taking down existing un-serviceable sub main wiring of any type and size upto 4 sqmm including making good the disturbed surface and matching the colour of wall with the existing colour complete all as specified and as directed.
Taking down existing un-serviceable sub main wiring of any type and size exceeding 4 sqmm including making good the disturbed surface and matching the colour of wall with the existing colour complete all as specified and as directed.
S&F in replacement of modular switch 1 way 6 amp 1 module complete all as specified and as directed.
S&F in replacement of modular socket 6 amp 2/3 pin combined 2 module complete all as specified and as directed.
S&F in replacement of of Factory made sheet metal enclosure single pole and neutral , 6 way with 200 amp rated bus bar , double door, fixed flush to the wall, 240 volt, IP-42 protection complete all as specified and as directed. Make:- C&S/Standard/Havells.
M&L sub main wiring with 4 runs of 6 sqmm PVC FRLS insulated unsheathed copper cable multistand 1100 V grade drawn in including surface casing-caping not less than 25mm dia and two run of PVC FRLS insulated unsheathed 6 sqmm coppper conductor cable as earth continuity conductor complete all as specified and as directed. Note:-: 4 runs of 6 Sqmm, 2 run of 6 Sqmm and 1 run of PVC casing caping will be measured as one unit length.
ANTARYAMI PANDA AND COMPANY
SAHADEV PALAI
PRASANTA KUMAR PANDA
ANIL KUMAR BISWAL
A P ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .