Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹5.0 L+₹10,597 (2.17%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
16 Mar 2020, 2:00 pmClosed
MAJ ALIF MANSOOR
GARRISON ENGINEER MES NASIRABAD - 305 601 (Raj)
REPAIRS AND MAINTENANCE OF SUMMER APPLIANCE AND AC PLANT
2020_MES_325541_1
8914/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
NASIRABAD
AS PER NIT
6 documents required · 6 mandatory
₹500
GE NASIRABAD
₹10,000
Yes
18 Jun 2020
15 Feb 2020
17 Mar 2020
15 Feb 2020
16 Mar 2020
2 Mar 2020
15 Feb 2020 - 19 Feb 2020
Amount
AIR CONDITIONER
Preliminary preparation of gas charging including supply and charging of gas Freon -22/CFC-134a to achieve the maximum cooling effect including vacuumising in the air conditioner, window type, 1.5 / 2Tonne capacity, 240 Volts, AC including necessary copper tubing, copper capillary to match with existing, soldering bracing necessary testing & commissioning complete all as specified and directed by Engineer-in-charge.
All as per sl item Non 2.00 here in before but in the air conditioner, split type, 1.5 / 2 Ton capacity with charging of compatible gas i.e F-22/R134a etc as directed by Engineer-in-charge. .
M & L for complete servicing of window AC 1.5/2 Ton capacity including disconnecting, cleaning dust particle with blower and cleaning the condenser fins with chemical and finally with water reconnecting and testing all upto the satisfaction of Engr-in-Charge complete all as specified and directed.
M & L for complete servicing of split AC 1.5/2 Ton capacity indoor & outdoor unit including disconnecting, cleaning dust particle with blower and cleaning the condenser fins with chemical and finally with water reconnecting and testing all upto the satisfaction of Engr-in-Charge complete all as specified and directed.
S & F PVC insulated copper conductor of cable 6 sqmm 3 core, multistranded heavy duty for lead of window / Split type AC including necessary connection complete all as specified and directed.
Taking out old unserviceable thermostat & supply and fixing new thermostat suitable for 1.5 ton capacity window type AC complete all as specified and directed. Make Renutrol/Indofoss/Annapurna/Danfoss
Taking out old unserviceable capacitor & supply & fix new running capacitor of 30/36 Mfd, ISI marked complete all as specified and directed. Make : Brite/Epcos/Dipcon/BRC.
Taking out old unserviceable capacitor & supply & fix new running capacitor of 10 Mfd, ISI marked complete all as specified and directed. Make : Brite/Epcos/Dipcon/BRC.
Taking out old unserviceable starting capacitor & supply & fix newstarting capacitor of 40/60 Mfd, ISI marked complete all as specified and directed Make : Brite/Epcos/Dipcon/BRC.
Taking out old unserviceable blower with fan motor from window type AC 1.5 ton capacity and S & F new blower fan motor double shaft, 3 speed, single phase, AC, 1/5HP, 920 RPM complete all as specified and directed. Make of Motor : As per existing. Makeof Blower : As per Existing
Taking out old unserviceable capacitor from spilt AC & supply & fix new running capacitor of 45 / 50 / 55 Mfd, ISI marked complete all as specified and directed. Make : Brite/Epcos/Dipcon/BRC.
Taking out old unserviceable indoor unit blower motor from split type AC 1.5/2 ton capacity and S & F new blower motor single phase, AC, 240 volts complete all as specified and directed. Make of Motor : As per existing.
Taking down old unserviceable compressor from window type air conditioner of capacity 1.5 tonne and S & F new company made compressor of Make as per existing compressor including charging of gas compatible to compressor i.e F 22/R134a etc. to achieve maximum cooling effect including vacuumising & necessary copper tubing including brazing complete all as specified & directed by Engineer-in-charge. Note : Compressor No of old unserviceable compressor & new compressor shall be entered in the MB.
Taking down old unserviceable compressor from split type air conditioner of capacity 1.5 tonne and S & F new company made compressor of Make as per existing compressor including charging of gas compatible to compressor i.e F 22/R134a etc. to achieve maximum cooling effect including vacuumising & necessary copper tubing including brazing complete all as specified & directed by Engineer-in-charge. Note : Compressor No of old unserviceable compressor & new compressor shall be entered in the MB.
WATER COOLER
Taking out the old unserviceable compressor with accessories from water coolers of following capacity, 240 Volts, AC, and supply & fix new compressor of make as per existing including charging of gas compatible to compressor i.e F-22/R134a etc. to achieve maximum cooling effect including vacuumising and necessary copper tubing including brazing complete all as specified and directed by Engineer-in-charge:- NOTE : Compressor No of old unserviceable compressor and reconditioned compressors shall be entered in MB.
Capacity 40/80 Lit, 240 Volts, AC, Single Phase
Capacity 60/120 Lit, 240 Volts, AC, Single Phase
Capacity 150/150 Lit, 240 Volts, AC, Single Phase
Preliminary preparation of gas charging including supply and charging of compatible gas i.e F-22/R-134a etc as directed by Engineer-in-charge to achieve the maximum cooling effect including vacuumising in the water coolers of the following capacities including necessary copper tubing, copper capillary to match with existing, soldering, bracing cleaning, tightening of loose nuts and bolts including necessary testing & commissioning complete all as specified and directed:-
Capacity 40/80 Lit, 240 Volts, AC, Single Phase
Capacity 60/120 Lit, 240 Volts, AC, Single Phase
Capacity 150/150 Lit, 240 Volts, AC, Single Phase
Taking down old unserviceable thermostat switch & supply & fix new thermostat switch for water cooler complete all as specified and directed by Engineer-in-charge. Make : Godrej / Anpurna / Woorlpool or as approved by GE.
Taking down old unserviceable relay with over load, box type & supply & fix new relay with over load, box type complete all as specified and directed suitable for following :- Make Hitachi / Anupurna / Whirlpool or as approved by GE
Capacity 40/80 Lit, 240 Volts, AC, Single Phase
Capacity 60/120 Lit, 240 Volts, AC, Single Phase
Capacity 150/150 Lit, 240 Volts, AC, Single Phase
Taking out old unserviceable condenser fan motor with blade and S & F new condenser fan motor with aluminium blades of capacity 1/35 HP, 220 volts, AC, 1250 RPM, class 'B' insulation, self lubricating type, suitable for 40/80 litre capacity water cooler complete all as specified and directed Make : Frac Master / Octira / Coolon or as approved by GE.
Taking out old unserviceable condenser fan motor with blade and S & F new condenser fan motor with aluminium blades of capacity 1/83 HP, 220 volts, AC, 1250 RPM, class 'B' insulation, self lubricating type, suitable for 60/120 litre, 150/150 litre capacity water cooler complete all as specified and directed Make : Frac Master / Octira / Coolon or as approved by GE.
Taking out old unserviceable top cover gasket of water cooler 80/120/150 ( storage capacity) and supply and fixing new top cover gasket complete all as specified & directed Make: Usha/Blue star or as approved by GE.
Taking out old unserviceable top cover holding clamp of water cooler of any capacity and supply and fixing new holding clamp complete all as specified and directed.
Taking out old unserviceable float valve of size 15 mm dia and supply and fixing float valve PTMT with epoxy coated aluminium rod and high density plastic ball both ends screwed for iron pipe 15 mm dia complete all as specified and directed
Taking out old unserviceable bib tap size 15 mm and S&F new bib tap cast copper, chromium plated, 15mm bore push type complete all as specified and directed
Taking out old unserviceable copper conductor cable lead and supply and fixing new copper conductor cable of size 2.5 sqmm 3 core, PVC sheathed and overall PVC insulated complete all as specified and directed
Taking out old unserviceable plug top from water cooler any capacity and S & F new plug top complete all as specified and directed
Taking out old unserviceable PVC drain pipe from water cooler any capacity and S & F new PVC drain pipe of size 40 mm dia complete all as specified and directed
REFRIGERATOR & DEEP FREEZER
Taking out the old unserviceable compressor, dryer filter from Refrigerators of following capacity, 240 Volts, AC, and supply & fix new compressor of make Tecumeseh/ Kirloskar and dryer filter & necessary copper tubing, charging of gas (F-22/CFC-134) to the maximum to achieve maximum cooling effect including vacuumising and fix with nuts & bolts, testing & commissioning complete all as specified and directed. NOTE :- Compressor No of old unserviceable compressor and new compressors shall be entered in MB.
Capacity 165 to 180 Lit, 240 Volts, AC, Single Phase.
Capacity 280 to 320 Lit, 240 Volts, AC, Single Phase.
Taking out the old unserviceable compressor, accessories from Deep freezer of capacity 320 to 400 ltrs, 240 Volts, AC and supply & fix new compressor of make Tecumeseh/ Kirloskar and dryer filter & necessary copper tubing , charging of gas (F-22/CFC-134) to the maximum to achieve maximum cooling effect including vacuumising and fix with nuts & bolts, testing & commissioning complete all as specified and directed. NOTE :- Compressor No of old unserviceable compressor and new compressors shall be entered in MB.
Preliminary preparation of gas charging including supply and charging of gas Freon-22/CFC-134 to achieve the maximum cooling effect including vacuumising in the refrigerators of the following capacities including necessary copper tubing, copper capillary to match with existing, soldering, bracing including necessary testing & commissioning complete all as specified and directed.
Capacity 165 to 180 Lit, 240 Volts, AC, Single Phase.
Capacity 280 to 320 Lit, 240 Volts, AC, Single Phase.
Taking out old AXIAL FAN and S & F new Axial fan 220- 240 V, AC 50hz, 120 x 120 x 38 mm of size suitable for capacity 320 ltr of Deep freezer complete all as specified and directed. Make Frac master/octria/coolon/Kool flow of as approved by GE
Taking down old unserviceable relay, open type with over load & supply & fix new relay, open type with over load for Refrigerator and deep freezer of any make, 165 to 310 litre capacity complete all as specified and directed.
Taking down old unserviceable auto defrost thermostat switch assembly & supply & fix new auto defrost thermostat switch assembly of temperature range 30ºF to 40ºF for refrigerators any make of following capacities complete all as specified and directed.
Capacity 165 to 180 Lit, 240 Volts, AC, Single Phase.
Capacity 280 to 320 Lit, 240 Volts, AC, Single Phase.
Taking out the old unserviceable freezer compartment with door and supply and fix new freezer compartment with door of the same company including making all necessary connections charging of gas (F- 22/ CFC-134) to the maximum to achieve maximum cooling effect including vacuumising to the entire satisfaction of Engineer-in-Charge for the following capacities of refrigerators complete all as specified & directed:-
Capacity 165 to 180 Lit, 240 Volts, AC, Single Phase.
Capacity 280 to 320 Lit, 240 Volts, AC, Single Phase.
Taking down old unserviceable freezer door from refrigerator and S & F new PVC door for freezer compartment suitable for the following capacities Refigerator complete all as specified and directed.
Capacity 165 to 180 Lit, 240 Volts, AC, Single Phase.
Capacity 280 to 320 Lit, 240 Volts, AC, Single Phase.
Taking down old unserviceable thermostat switch from Refrigerator and deep freezer of cap 310/320 Ltr & supply & fix new thermostat switch suitable for Refrigerator and deep freezer complete all as specified and directed.
Taking down old unserviceable illumination bulb of refrigerator 165 to 320 Ltr and supply and fix new illumination bulb size as per existing complete all as specified and directed.
Taking out oldunserviceable vegetable tray of 165 to 320 Ltrs Refrigerator Make Whirlpool/LG/Samsung/ Godrej and supply and fix new vegetable tray as per existing complete all as per specified and directed.
Taking out old unserviceable steel rack of 165 to 320 Ltr Refrigerator Make Whirlpool/LG/Samgsung/ Godrej and supply and fix new steel rack duly painted as per existing complete all as specified and directed.
DESERT COOLER
3000 Cum/hrs nominal airflow capacity
4000 Cum/hrs nominal airflow capacity
Disconnecting and taking out motor from desert cooler and M & L for rewinding of fan motor of desert cooler upto 4000 cum/hr with super enamelled copper wire of appropriate gauge & weight equal to the existing & refixing the same to its original position complete all as specified & directed.
Taking out old unserviceable gun metal bush from desert cooler fan motor assembly and S&F new gun metal bush all as directed.
S & F in repairs switch mounting plate of desert cooler made of aluminium duly painted as per existing size complete all as specified and directed.
Taking out old unserviceable water pump from desert cooler and S & F new water pump, submersible type, AC, 230 volts, 50Hz, 18 Watt fixed in position with & including nuts & bolts of appropriate size and necessary testing complete all as specified & directed. Make : Khaitan / Bajaj / Crompton Greaves / Micra.
Taking out old unserviceable grass pad from desert coolers and S & F new grass pad suitable for 3000 to 4000 cum/hr capacity desert cooler including necessary clamps complete all as specified & directed.
Taking out old unserviceable capacitor & supply & fix new capacitor of cap 4 mfd, ISI marked for desert cooler complete all as specified and directed. Make : Brite/Epcos/Dipcon/BRC
Taking out old unserviceable cast iron outer ring of desert cooler motor and supply and fix new cast iron ring complete all as specifiedand directed. Make : Brite/Epcos/Dipcon/BRC
VOLTAGE STABLIZER
M & L for opening of voltage stabilizer single phase, 230 volts, 50Hz, AC of capacity as mentioned below testing and detecting defective parts taking out defective parts including repair / replacement of unserviceable parts with new parts cleaning and re-assembling and testing after repair all upto the entire satisfaction of Engr in charge complete all as specifiedand directed. Note:- New parts shall be measured and paid separately under respective items of BOQ as 'Supply only'.
Capacity 1 KVA
Capacity 2/3 KVA
Capacity 4/5 KVA
Supply only Main auto transformer, single phase, AC 50 Hz suitable for the following capacity voltage stabilizer complete all as specified and directed.
Capacity 1 KVA
Capacity 2/3 KVA
Capacity 4/5 KVA
Supply only Auxilary transformer suitable for 230 volts AC supply for the following capacities voltage stabilizer complete all specified and directed.
Capacity 1 KVA
Capacity 2/3 KVA
Capacity 4/5 KVA
Supply only electronic circuit plate (PCP) suitable for the following capacity voltage stabilizer complete all as specified and directed.
Capacity 1 KVA
Capacity 2/3 KVA
Capacity 4/5 KVA
Supply only High and Low voltage cut off relay suitable for the following capacities voltage stabilizer complete all as specified and directed.
Capacity 1 KVA
Capacity 2/3 KVA
Capacity 4/5 KVA
Supply only voltmeter digital type 0 to 300 volts, AC, single phase suitable for the following capacity voltage stabilizer complete all as specified and directed.
Capacity 1 KVA
Capacity 2/3 KVA
Capacity 4/5 KVA
Supply only POWER ON indication lamp as per existing suitable for 1 to 5 KVA capacity, 50 Hz, AC voltage stabilizer complete all as specified and directed.
Taking out old unserviceable copper conductor lead with plug top and supply and fixing PVC sheathed and over all PVC insluated new copper conductor lead 3 core, 2.5 sqmm , 3 mtr long with 5 Amps top plug for 1 to 2 KVA complete all as specified and directed
Taking out old unserviceable copper conductor lead with plug top and supply and fixing PVC sheathed and over all PVC insluated copper conductor lead 3 core, 4 sqmm , 3 mtr long with 5 Amps top plug for 4 to 5 KVA complete all as specified and directed
AC PLANT
Taking out old unserviceable contactor and supply and fix contactor type 3TF47, 230 V, 50 Hz including necessary connection complete all as specified and directed. Make :- Siemens/L&T/C&S or equivalent as approved by GE.
Disconnecting and taking out old unserviceable Temperature Sensor with cable & supply and fix new chiller unit temperature sensor with cable and connecting to starter panel including testing complete all as specified and directed.
Taking out old unserviceable contractor relay and supply and fixing new contactor relay, 230 volts, 50 Hz capacity complete all as specified and directed. Make :- Siemens/L&T/C&S or equivalent as approved by GE.
Taking down old unserviceable cooling fins & Supply and fix cooling tower fins suitable for upto 160TR capacity of existing make complete all as specified and directed.
Supply and filling compressor oil of N-68 grade including opening of compressor in position, cleaning the oil chamber and draining out old oil from the chamber and testing after filling of oil complete all as specified and directed.
Supply and charging of Refrigerant R 407C to top up the of Central AC plant up to required level (03 Nos) for required cooling effect and testing after filling of refrigerent complete all as specified and directed.
Taking out old unserviceable MCCB & S & F MCCB, 250 Amp, 3 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting with thermal release range 160-200 Amp including spreader terminals and phase barriers complete all as specified and directed. Make L&T/Schneider/ Legrand as approved by GE.
Supply and fix in repair MCB, triple pole, 63 Amp capacity , 'C' curve, 10 KA complete all as specified and directed.
Supply and fix in repair MCB, triple pole, 50 Amp capacity , 'C' curve, 10 KA complete all as specified and directed.
Descaling the condenser (78.8 TR capacity AC Plant) with and using descaling solution. The solution will be circulated till all the scale from the tube is removed. The left over scale will be removed by nylon brush of size 5/8" fixed on rod by circulation of fresh water through condenser till the clear water comes out from the other end and including repairs complete all as specified and directed. Note : Descaling solution acid pump, elect line and elect connection will be arranged by the contractor at their own expenses. No extra shall be admissible on this account.
Cleaning of cooling coil including dismantling of suction line from compressor with feeding of chemical solution (carbon tetra chloride) through cooling coil for flushing out of oil and dust of cooling complete all as specified and directed.
M & L for cleaning of compressor chamber of 20 TR capacity AC Plant and replacement of oil filter, cover gasket, servicing of compressor, charging of compressor oil, leakage test, pressure test, replacement of defective shaft seal, repair and adjustment to loader/unloaded system, minor nuts bolts and minor parts & realignment of motor and compressor complete all as specified and directed.
M & L for servicing of cooling tower including draining out complete water from bottom tank and cleaning complete inner surface with nylon brush, opening of water strainer from water inlet to condenser after removing of flange and replacement of gasket and jali after cleaning/removing of foreign material from inside the strainer and cleaning of blocked spray nozzles including descaling of complete water line with descaling solution complete all as specified and directed.
Servicing of AHU 16000 CFM unit including cleaning of cooling coils with chemical and cleaning of air filters, micro filters, draining out old water from inlet and outlet pipes and refilling fresh water and testing after servicing upto the entire satisfaction of EIC complete all as specified and directed.
Servicing of AHU 23000 CFM unit including cleaning of cooling coils with chemical and cleaning of air filters, micro filters, draining out old water from inlet and outlet pipes and refilling fresh water and testing after servicing upto the entire satisfaction of EIC complete all as specified and directed.
Taking down old unserviceable 5 HP motor from site and winding of motor with appropriate gauge of copper wire and made functional and refix in same location including testing on completion complete all as specified and directed.
Taking down old unserviceable 7.5 HP motor from site and winding of motor with appropriate gauge of copper wire and made functional and refix in same location including testing on completion complete all as specified and directed.
M & L for carry out leakage test for complete unit through Nitrogen gas and sealing of leakage through welding / brazing including pumping down of gas before leakage test and refilling of gas after carry out the leakage test complete all as specified and directed.
S & F in repair water pressure gauge 10 Kgs x 100 mm dia complete all as specified and directed. Make- Ramco or any equivalent make as approved by GE.
S & F in repair brass butter fly valve, liver operated, 150 mm dia complete all as specified and directed.
M & L for complete servicing/cleaning of motor and pump with Kerosene or by blower where necessary, tightening of loose nuts and bolts, greasing, gland packing and tightening of all electrical connections for the following capacities pumping sets complete all as specified and directed.
Capacity 7.5 HP
Capacity 5 HP
M &L for applying two coat of synthetic enamel paint over old painted steel/iron surface including preparation of surfaces of following complete all as specified and directed:-
Centrifugal pump set including motor of 5 to 7.5 HP capacity
NRV 150 mm dia.
Butter fly valve 150 mm dia .
All incoming/outgoing pipe lines of central AC plant (3x78.8 Ton)
AIRCOM
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .