GE RD East Bangalore 93
MAINTENANCE REPAIRS REPLACEMENT OF EXTERNAL ELECTRIFICATION HT LT DISTRIBUTION SYSTEM WORKS AT DFRL MYSORE
2021_MES_434327_1
8102
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D East Bangalore
D b (i) b (ii)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹94,000
Yes
16 Jun 2021
5 Apr 2021
5 May 2021
5 Apr 2021
3 May 2021
20 Apr 2021
6 Apr 2021 - 13 Apr 2021
Amount
Material and labour for servicing of HT VCB panel indoor type 630 Amp,11 KV as incomer+3x630 Amps,11 KV as outgoing ,complete by checking main connetion and control circuit including replacement of unserviceable accessories, testing complete with full load operations to the satisfaction of Engineer- in- charge.
Material and labour for servicing of HT VCB panel indoor type 630 Amp,11 KV as incomer+2x630 Amps,11 KV as outgoing ,complete by checking main connetion and control circuit including replacement of unserviceable accessories, testing complete with full load operations to the satisfaction of Engineer- in- charge.
Supply and fix in replacement Gang operating device triple pole mechanically operated mounted on insulators and steel frame, with operating mechanism work from ground level for current rating upto 200 amps
Supply and fix in replacement cross arms brasing supports, clamps and back plate fabricated from structural steel sections of any type including nuts, bolts washers, welding, bending, cold or hot drilling holes for bolts, made to any shape or size as directed including one coat of red oxide promer and two coats of synthetic enamel paint including cutting / welding / holding fast / grouting complete as required at site and as directed by Engineer - in- Charge including taking down old unserviceable bracing.
Taking down unserviceable lightening arrester, material and labour for lightening arrestors, expuision type complete with all fittings, transmission class discharge capacity 65 KA, suitable for 11000 volts including testing and commissioning complete all as specified and as directed.
Supply and fix in replacement PVC line separators suitable for 3 phase 4 wire over head lines conductors fixed at any point between two poles all as specified and directed.
Material and labour for plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in foundation filling and mass concrete for stay/ poles etc complete all as specified and as directed.
Material and labour for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate for coping of pole complete all as specified and as directed.
Supply and errect in replacement steel tubular pole swages 8.5 mtr long complete with C1 base plate, final taper plug, bolts nuts and screws as specified type 410 SP-22 (8.5 mtr long) complete all as specified and as directed. (excavation and other connected work can pay seperately).
Supply and fix in replacement MCCB 400 Amps, 4 pole,with adjustable thermal magnetic release, rupturing capacity 25 KA, 415 Volts including taking down unserviceable MCCB complete all as specified and as directed.
Supply and fix in replacement MCCB 200 Amps, 415 Volt, 3 pole , adjustable type with rupturing capacity 25 KA complete all as specified and as directed.
Supply and fix in replacement MCCB 100 Amps, 415 volt, 3 pole, adjustable type with rupturing capacity 25 KA complete all as specified and as directed.
Supply and fix in replacement MCCB 63 Amps, 415 volt, 3 pole adjustable type with rupturing capacity 16 KA complete all as specified and as directed.
Material and labour for out door heat shrinkable end termination for HT UG cable 11000 volt grade aluminium conductor 3 core XLPE insulated suitable for earthed system of size 185 Sqmm complete all as specified and as directed.
Material and labour for indoor heat shrinkable end termination fo HT UG cable 11000 volt grade aluminium conductor 3 core XLPE insulated suitable for earthed system of size 95 Sqmm complete all as specified and as directed.
Supply and fix Rubber insulation Mat 1100 volts grade of size 1mt X2Mt 10mm Thick
Supply and fix Rubber insulation Mat 1100 volts grade of size 1mt X2Mt 19mm thick
Supply only electric rubber and gloves 11 kVA
Supply and replacement in repair of double copper stainless steel gland for fixing armoured cable in panel of sizes 04 core 6 Sqmm to 16 Sqmm
Supply and replacement in repair of double copper stainless steel gland for fixing armoured cable in panel of sizes 04 core 25Sqmm to 35 Sqmm complete
Supply and replacement in repair of double copper stainless steel gland for fixing armoured cable in panel of sizes 3.5 core 50Sqmm to 70 Sqmm complete
Supply and replacement in repair of double copper stainless steel gland for fixing armoured cable in panel of sizes 305 core 95 Sqmm to 120 Sqmm complete
Supply and refill silica gel in silica gel container suitable for transformer breather
Taking down removing of unserviceable change over switch of capacity 400 Amps. After switching of electrical supply, supply and fix testing and commissioning of onload change over switch of 400 Amps as per existing sample i.e. make: standard including makeing cable connection.
All as per item No 24 above, but of chage over of capacity 800 amps
Earthing complete with GI earth plate electrode 60cmx60xcmx6mm size buried directly in ground with bottom edge of the plate not less than 2.25 meters below normal ground level and connected to GI earth lead of size 4mm as earth lead by means of nuts bolts etc with and including necessary excavation, earth chamber with plain cement concrete 1:3:6 type C-1, necessary RCC chamber cover in cement concrete 1:2:4 with nominal reinforcement, funnel etc., all as shown in electrical plate No.3 of SSR Part I connected to earthing test point including testing on completion all as specified and as directed.
All as per ser item No.26 above but using galvanised iron strip 25 x 4 mm as earth lead.
All as per ser item No. 26 above but using galvanised iron strip 32x6 mm as earth lead.
M&L for chemical earthing complete with copper plate of size 600x600x5mm thick barried directly and preferably vertical in gound with top edge not less than 1.5mtr below ground level connected with earth plate 32x6mm connected to earth testing point all as specified and directed by Engineer-in-Charge.
Supply and fixing galvanized steel water tubing medium grade pipe of size 40mm for protection of copper earth stript all as specified by and directed by Engineer-in-Charge.
Material and labour for repairs to LT panel board out door type by taking out carefully existing unserviceable cut outs 200 amps capacity -03 Nos. 100 capacity-03 Nos, 63 Amps capacity -06 Nos and 32 amps capacity -03 Nos including bus bar of size 40mmx6mmx340mm long and supply and fixing of the following in the panel complete
(a) Ply wood water proof ISI marked 20mm thick of size 0.6mtr x 1.10 mtr
(b) MCCB 200 amps, 25 KA, 415 V, 3 Pole with adjustable thermal and magnetic settings 01 No
(c) MCCB 100 Amps, 25 KA, 415 V, 3 pole with adjustable thermal and magnetic settings-01 No.
(d) MCCB 63 Amps, 25 KA, 415 V, 3 pole with adjustable thermal and magnetic settings -02 Nos.
(e) MCB TPN 32 Amps, 10 KA, 415 V -01 No.
(f) Refixing of Bus bar Aluminium -04 nos of size 40 x 6 mm and 340 mm long, with new epoxy based insulators and colour coded sleeves
(g) Voltmeter 0-500 Volts-01 No.
(h) Internal wiring complete with suitable size copper wires- 1 Job
Excavation in trenches n.exe. 1.5 m depth and not exe 1.5 m wide for laying of cable and getting out in hard/ dense soil
Removal of surplus soil obtained from excavation to a distance not exc 50 metre and depositing where directed at a level n exc above the starting point complete all as specified and as directed.
Supply and fix pole caps as per sample to MS poles of height 9/9.5 mtr long made out of 3mm thick CRCA sheet with fixing arrangement complete with one coat of red oxide primer and two coats of synthetic enemelled paint complete all as specified and as directed.
Supply and welding in replacement broken hinges for panel door as per existing one and touch up painting of the same.
Supply and fix angle iron of size 60x60x6 mm thick including painting one coat of red oxide and 2 coat of enamel paint complete
Supply and fix round rod iron of size 16 mm dia including painting one coat of red oxide and 2 coat of enamel paint complete
Supply and fix MS round tube of thickness 3mm ,40 mm dia of MS Tube including painting one coat of red oxide and 2 coat of enamel paint complete
Supply and fix MS round tube of thickness 3mm ,25 mm dia of MS Tube including painting one coat of red oxide and 2 coat of enamel paint complete
Supply and fix MS mess 30mmx60mm of thickness 3.5 mm including painting one coat of red oxide and 2 coat of enamel paint complete
Supply and fix in replacement LED fittings Recessed/Surface 2X2 Tile design is suitable in all spaces. Capacity :36 W Ca refLCTLSN-36-CDL of CG or equivalent in Bajaj/ Philips.
Supply and fix in replacement of battery 12 Volts,110 Ah@C10,(End cell voltage 10.80 Volts), Tubular LMLA Battery Make Tata suitable for solar system all as specified and as directed.
Supply and fix in replacement power contactor Type:-MNX 45 cat No CS97074 Make L & T or equivalent
Supply and fix in replacement power contactor Type:-MNX 70 cat No CS97074 Make L & T or equivalent
Supply and fix in replacement power contactor Type:-MNX 40 cat No CS940190 Make L & T or equivalent
Supply and fix maintenace free battery 12 Volts,7.5 AH of make Exide or equivalent for Passenger/goods lift Capacity 544 Kg/8 person- the per all as directed and specified.
Supply and fix Phase monitor 208-280 VAC for Passenger/goods lift Capacity 544 Kg/8 person- the per all as directed and specified.
Supply and fix in replacement battery 12 Volts, 80 AH, Make exide with indicators such as 'ADD distilled water' , 'NEEDS Charging', 'OK' complete all as specified and as directed.
M & L test terminal block made of gun metal or phosphorous bronze size 75x75 x25 mm drilled and screwed incl 03 nos. 8 mm dia 25 mm long hex head screw
Supply and fix MS box of size 150mm x100 mm and 75 mm deep with door and locking arrangement,made out of 2 mm thick CRCA sheet duly painted with one coat of red oxide primer and two coats of synthetic enemelled paint for housing test terminal block
Supply and fix in replacement APFC relay 8 stage make L & T model No. eta CON L8 or equivalent
Supply and fix in replacement contractor heavy duty Make: L&T, 20 amps capacity, 3 pole, 415 V to 50 hz, capacity duty complete all as specified and as directed.
Supply and fix in replacement capacitor duty contactor make L & T model MO C 8.5
Supply and fix in replacement capacitor duty contactor make L & T model MO C 12.5
Supply and fix in replacement capacitor duty contactor make L & T model MO C 15
Supply and fix in replacement capacitor heavy duty type MPP of rating 5 KVAR 440V, 50Hz, AC cylindrical type complete all as specified and as directed Make: EPCOS, model PHICAP
Supply and fix in replacement capacity heavy duty type MPP of rating 10 KVAR 440V, 50Hz, AC cylindrical type complete all as specified and as directed Make: EPCOS, model PHICAP
Supply and fix in replacement capacity heavy duty type MPP of rating 15 KVAR 440V, 50Hz, AC cylindrical type complete all as specified and as directed Make: EPCOS, model PHICAP
Supply and fix in replacement capacity heavy duty type MPP of rating 20 KVAR 440V, 50Hz, AC cylindrical type complete all as specified and as directed Make: EPCOS, model PHICAP
Supply and fix in replacement LED Bollard light luminaire ID No. 20062300997 ,IP44,Colour Temprature 3500-4000K cool white Make Bajaj or Equivalent in Philips/CG complete with making platform of size 1.5'X1.5' including supplying and fixing of PVC junction box with bus bar of suitable size including MCB of capacity 6 Amps all as specified.
Supply and fix round surface monted LED flat panel PCD aluminium housing and pmma diffuser of capacity 12 watt,240 volts, make: Crompton of cat ref LCDSPLN-12-CDL or equivalent in Philips/bajaj.
Supply and fix round surface monted LED flat panel PCD aluminium housing and pmma diffuser of capacity 18 watt,240 volts, make: Crompton of cat ref LCDSPLN-18-CDL or equivalent in Philips/bajaj.
Supply and fix LED highbay with injection molded high performance poly carbonate reflector,ideally suitable for warehouses, capacity 36 watt,240 volts, make: Crompton of cat ref LWV11-36-CDL/RFR or equivalent in Philips/bajaj.
Supply and fix in replacement LED tube Linear LED T8 tubular lamp with fitting of Capacity 20 watt with extruded aluminium body PC diffuser and inbuilt driver. Ca ref LTT8-20 of CG or equivalent in Bajaj/ Philips.
Supply and fix in replacement LED fittings Recessed/Surface 2X2 Tile design is suitable in all spaces. Capacity :36 W Ca refLCTLSN-36-CDL of CG or equivalent in Bajaj/ Philips.
Material and labour for point wiring wih PVC insulated copper stranded FRLS conductor single core cable of 1.5 sqmm size drawn throug rigid non metalic PVC conduit fixed on wall/ceiling with replacement of existing steel metal boxes with new modular metal flush boxes modular white cover plate with frame for mounting of modular switches/socket regulator and including 1.5 sqmm PVC insulated unsheathed copper cable green in colour as continious contuinity conductor and connected to earth dolly for following all as specified and as directed for light building securiy light one light point control by one 06 Amp switch.
Supply and fix modular switch 1 way 6A 1 module one way complete all as specified and as directed.
Supply and fix LED spot light specially design for commercial usage long life with 30000 burring hrs 40 W beam angle 36 degree CAT No CDR-125-50-40-SLNWH
Supply fixing decorative post top for garden and land scape lightning with IP 65 protection resistance to inpact and crossion antiglare and uniforme distribution CAT No LPTOI-45-T
Supply fixing time less class Lunar is top of the class with range of three sizes idel for model living places CAT No LCSUR6-40-CDL
Supply and fixing perforated aluminium cable trays width 300mm, side rail high 100mm complete
Supply and fixing perforated aluminium cable trays width 200mm, side rail high 100mm complete
Supply and fix in replacement solar LED panel IP-55 of capacity 20 watt,solar panel configuration 1280 wp PV Module of Make TATA BP solar all as specified.
M AND V ENTERPRISES
eurekaenterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .