Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | MEDINIPUR WEST | WEST BENGAL | 721305 | ₹1.4 Cr | L1 | Accepted-AOC Lowest bid value |
| 2 | L2₹2.0 Cr+₹50.9 L (35.3%)Rejected-Finance KHEMASULI P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPUR WEST BENGAL | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | ₹2.0 Cr+₹50.9 L (35.3%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹2.1 Cr+₹63.1 L (43.7%)Rejected-Finance | ₹2.1 Cr+₹63.1 L (43.7%) | L3 | Rejected-Finance Not being L1 |
Tender Value
₹2.1 Cr
EMD Value
₹2.9 L
Closing Date
11 Dec 2023, 6:00 pmClosed
CWE (AF) KALAIKUNDA
CWE (AF) KALAIKUNDA KALAIKUNDA AIR FIELD POST WEST MIDNAPORE DIST WEST BENGAL- 721303
IMPROVEMENT OF MD ACCOMODATION AT AF STN KALAIKUNDA
2023_MES_625582_1
8645/KKD/E8
Open Tender
Civil Works
Item Rate
360 days
AT AF STN KALAIKUNDA
AS PER NIT
7 documents required · 7 mandatory
₹2,000
GE (AF) KALAIKUNDA
₹2.9 L
Yes
13 Jan 2024
30 Oct 2023
13 Dec 2023
30 Oct 2023
11 Dec 2023
27 Nov 2023
Amount
Excavation in post holes (or similar holes) in hard/dense soil each n.exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed.
Surface excavation in hard/dense soil not exceeding 30cm deep and averaging 15cm deep and getting out complete including removal to distance exceeding 250m but not exceeding 1000m all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil or any type of soil, complete all as specified and directed.Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final conclusive and binding.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Taking out old unserviceable cable of any size carefully from trenches ofter disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed. Note : The Excavation and earth work shall be mesured and paid separately under relevant item of Schedule.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of fly ash bricks well burnt old designation 75 cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness (below or above ground level) and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified.
Demolition of reinforced cement concrete of any description and in any position (Reinforement cut as required to facilitate demolition) and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified.
Taking down eaves gutters and rainwater pipes (any size or pattern), soil waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed
M&L moorum/red bajri filling in floors or pavings laid in layers nexc 15cm thick spread levelled and rammed including watering complete all as specified and as directed
M&L Cutting openings through walls for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for under?pinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the prem complete all as specified
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as directed.
Dismantling of stone slabs and tiles of any description or thickness as on platform, shelves, floors etc laid, bedded and pointed in any mortar complete all as directed.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking out old unserviceable GI/PVC/PPR pipes from trenches, walls, floors, ceiling and duct etc including all fittings of 50 mm bore complete all as specified and directed by Engr-in charge. Note: Excavation/earth work will be measured and paid separately under relevent item.
Taking out old unserviceable GI/PVC/PPR pipes from trenches, walls, floors, ceiling and duct etc including all fittings of 25 mm bore complete all as specified and directed by Engr-in charge. Note: Excavation/earth work will be measured and paid separately under relevent item.
Taking out old unserviceable GI/PVC/PPR pipes from trenches, walls, floors, ceiling and duct etc including all fittings of 20 mm bore complete all as specified and directed by Engr-in charge. Note: Excavation/earth work will be measured and paid separately under relevent item.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed (unit rate shall be inclusive of demolition of cement concrete blocks for embedding hold fasts complete.)
Taking down chowkats of frames wth shutters (without taking out off shutters from the frame) exc 1.5 sqm and n exc 4.00 sqm each including hold fasts and removing the same from site complete all as specified and as directed. (unit rate shall be inclusive of demolition of cement concrete blocks for embedding hold fasts complete.)
Taking down shutters of any description exc 1 sq. m and not exc 2 sq. m each .complete all as specified and directed.
Taking down and refixing of shutter of any description in same opening including necessary easning and cutting area of each panel exceeding 1 Sqm n.exc 2 Sqm each Note : Refixing incl taking down easing and adjusting and also refxing builders hardware as reqd incl removal of unserviceable screws etc. Hardware items will be paid at supply only rates except screws and nails
supply only 100mm long Butt hinges, medium weight, cold rolled mild steel fixed with screw complete all as specified and directed.
Supply only 75mm long Butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
Roughening surfaces of old concrete as in floor by picking, sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.0 Kg of cement per sqm complete all as specified and as directed.
M & L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth in brick walls complete all as specified and as directed.
M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling with cement mortar (1:4) with using WPC as per manufacturers instruction over two coast of primer mixed of Latex and cement @ 1:4 (by weight) in the grooved portion and extended upto 100 mm both sides of groove complete all as specified and as directed.
Materials and Labour for waterproofing treatment to existing RCC roof in the following steps complete all as specified and directed. (i) Complete removal of the existing water proofing treatment including padding (buid in cm/concrete) and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete (ii) Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area) (iiii) Supply and Laying, chicken wire mesh of size 12.5 mm x 0.51 mm (24 SWG) hexagonal construction including all laps, cutting and waste in fabric reinforcement to PCC roof padding including providing 40 mm thick plain cement concrete (1:2:4) type B0using 12.5 mm graded aggregates as in roof padding. (iv) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions, on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement. (v) Waterproofing treatment over smooth finished surfaces after application of bituminous primer @ 0.40 ltrs per sqm over prepared surfaces of roof including parapet surfaces confirming to IS : 3384 (primer and membrane to be used shall be same manufacturer) prime shall be brand of Shalitex of STP or EmufalTE of M/s Texa Indian Ltd or cold stick bitumen primer of M/s IWL or equivalent make ,(vi) providing and laying APP polymer, modified, non-woven polyester fabric of 150 grams/square metre, reinforced membrane, 3.00 mm thick, weighing 3.60 Kg / Sq M, by torch on application method, with minimum 75 mm overlap on longitudinal direction and 100 mm overlap on the transverse direction and (vii)finally applying with one coat of bituminous based solar reflective aluminium paint @ 125 gms / Sq M or as per manufacturer,s instructions complete all as specified and directed. Make of APP Membrane : M/s STP Ltd./M/s Texsa India Ltd./M/s IWL India Ltd 3. APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionand Leak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be submitted. Requisite 10 years guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion of testing. The submission of both certificate is mandatory before issue of completion certificate.
Materials and Labour for waterproofing treatment to existing RCC roof in the following steps up to 10 mtr height including necessary scalfolding and safety measures complete all as specified and as directed. (i) Complete removal of the existing water proofing treatment and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete (ii) Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc and Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions, on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement. (iii) Applying bituminous primer @ 0.40 ltrs per sqm over prepared surfaces of roof including parapet surfaces confirming to IS : 3384.(primer and membrane to be used shall be same manufacturer) prime shall be brand of Shalitex of STP or EmufalTE of M/s Texa Indian Ltd or cold stick bitumen primer of M/s IWL or equivalent make (iv) One layer of APP based polymeric membranes of approved manufacturers, 3 mm thick, weight not less than 3.6 kg/sqm, reinforced with non woven polyester fabric (weight not less than 160 gms/sqm). Polymeric membrane shall be taken to cover the thickness of slab and shall be finished by a membrane flushing. Note: (v) Laying of APP based membranes shall be done by torch application or as per manufacturer's instructions. (vi) Side overlaps shall be minimum 75 mm and the end taps shall be minimum 100 mm and sealing of all overlaps & joints as per manufacturer instruction. (vii) For parapets, membranes shall be taken to a height of minimum 60 Cm and then inserted to the parapet in a groove. The same shall be finished by a membrane flashing.(viii)finally applying with one coat of bituminous based solar reflective aluminium paint @ 125 gms / Sq M or as per manufacturer,s instructions complete all as specified and directed 3. APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionand Leak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be sumitted. Requisite 10 years guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion of testing. The submission of both certificate is mandatory before issue of completion certificate.
Materials and Labour for, broken stone or boulder hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface , complete all as specified and directed.
Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles throating,and roof padding as directed including necessary from work complete all as specified and directed.
M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed
Materials and Labour for reinforced cement concrete M-20 Nominal mix in chajjas,beam ,landing and similar suspended work complete all as specified and directed.
Use and waste of form work to sides and soffits of beams, bands and the like for fair finished surfaces of concrete complete all as specified and directed.
Preparation of concrete surface of chajja/beam/slab thoroughly abraded to remove all laitance, any trace of loose plaster,cement concrete , oil, grease, paints and any other materials are to be removed by wire brushing the surface. The entire surface shall then be washed thoroughly with plenty of water and then allowed to dry. Defective concrete surfaces cut back to a sound base by chipping and removed loose concrete. Smooth surfaces to achieve by chemically roughened up to 10 Mtr height including appling bond coat of epoxy bonding agent (Nito Bond) & cement in 1 : 1 ratio bonding old and new concrete on damaged surface and all necessary scaffolding and safety measures all as specified and directed. .(The cost of entire operation shall be carried out by approved manufacturers or their authorized applicator and deemed to be included in unit rate).
M&L for cleaning to expose corruded reinforcement of chajja/beam/slab by wire brushing, emery paper or by mechanical means and to remove all loose scale and corrosion deposit and washing complete and providing additional reinforcement TMT bars of approved make, cut to length by electro welding method and applying one coat of rust removing chemical and anti rust coating (zinc) along its full circumference up to 10 Mtr height including all necessary scaffolding and safety measures all as specified and directed. (Manufacturer name of chemical shall be : Fosroc/Sika/Pidilite/BASAF) The cost of entire operation shall be carried out by approved manufacturers or their authorized applicator and deemed to be included in unit rate).
M&L for providiing and placing high built repair ready mix concrete (Micro concrete) grade of M-50 specification and strength conforming to ASTM- C109-99,ASTM- C 307 ,BS1881 Part 207 to expose corroded reinforcement of chajja/beam/slab with bonding agent as per manufactures instruction (Manufacturer : Fosroc/Sika/Pidilite/BASAF) proper compaction and finished to proper level upto a Average depth of 20mm with and including provision of formwork to the affected portion up to 10 Mtr height including all necessary scaffolding all as specified and directed.(entire operation shall be done by the approved manufacturer or their authorized applicator and deemed to be included in the unit rate)
M&L for providiing and placing high built repair ready mix concrete (Micro concrete) grade of M-50 specification and strength conforming to ASTM- C109-99,ASTM- C 307 ,BS1881 Part 207 to expose corroded reinforcement of chajja/beam/slab with bonding agent as per manufactures instruction (Manufacturer : Fosroc/Sika/Pidilite/BASAF) proper compaction and finished to proper level upto a Average depth of 40mm with and including provision of formwork to the affected portion up to 10 Mtr height including all necessary scaffolding all as specified and directed.(entire operation shall be done by the approved manufacturer or their authorized applicator and deemed to be included in the unit rate)
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 105 mm X 60 mm, Profile C, single rebate or more including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed.
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, size 125 mm X 60 mm, Profile C, single rebate or more including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed.
S & F 28 to 30mm thick “FACTORY MADE MOULDED DOOR SHUTTER" consisting of solid core single leaf Flush Door of 30mm thickness, lipped with 15mm (5mm x 3) thick x 30mm width on one stiles and top rails & 10mm (5mm x 2) thick x 30mm width on the other stiles & bottom rails. The inner panel laminated with 2mm thick Sheet of Density 700 Kg /Cbm Manufactured by an ISO-9000 certified Company, termite proof, water proof and fire resistant moulded PVC Sheet with 2, 4, 6 raised panel design in different plain and / or prelam colours on one side after routing the Moulded design on flush door & 2mm plain and /or prelam PVC sheet on other side using rubber based adhesive on flush door & solvent cement adhesive on the PVC lipping etc. complete as per direction of Engineer-in-charge, manufacturer’s specification and drawing complete all as specified and directed.
Supply and Fix, solid PVC door frame of size 50 mm X 47 mm made out of 5 mm Prelam PVC sheet reinforced with MS square tube, fixed in opening all as specified and directed.
Supply and Fix, factory made solid panel prelam PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded prelam PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail: Panelling of both sides plain PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, fixed to door frame complete all as specified and directed.
Supply and Fix, factory made rigid lam PVC door frame of size 100 mm x 50 mm, single rebated with wall thickness of extruded 5mm PVC sheet of density 600 kgs/cum , made by joining 3 Nos. heat bent PVC sheet sections. The inside section of size 90mm x 30 mm shall be made from colour PVC sheet of 5 mm thickness.The inside section shall be covered by sticking two sections of size 35mm and 6 x 45 mm made from 5mm thick plain sheet. The frame shall be mitred cut at two corners and jointed by inserting 4 Nos. 150 mm long brackets of 15mm x15 mm MS square tube. The two vertical members of door frame shall be reinforced with 40mm x 20 mm MS tubes of 19 SWG duly filled with 2nd class hardwood throughout the frame. The door frame shall be fixed to the wall using 100 mm long nikel coated dry wheet screws through the frame by using PVC fastener. Minimum 04 Nos. of screws shall be provided for each vertical member and minimum 02 Nos.for horizontal members etc. as per manufacturers specifications, fixed in opening, complete all as specified and directed.
Materials and Labour for, Factory Made Solid PVC Moulded Door designer Shutter, with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specification and drawing, complete all as specified and directed.
Supply and Fix, factory made wire gauzed PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded prelam PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed.
S&F factory made preprimed steel windows and ventilators (Box Section) with fly proof, glazed shutter and guard bars complete all as per shown in HQ CE SZ DRG No : AF/TD/286/22 of Sheet 1/3, 2/3 & 3/3 with and including precoated hinges, precoated handle, precoated towerbolt, glass and stainless steel wiremesh etc as shown in drawing complete all as specified and directed. (Make : NCLor equivalent make as approved) Note : Overall Single side measurment taken for payment including all fitting fixture, Wiremesh, glass, guard bars, chowkhat, window etc complete as shown in drawing.
S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S&F 300mm long mild steel ordinary quality rat rail rod pattern spring including roller plate complete fixed to steel surfaces including necessary welding complete all as specified and directed.
Supply and Fix, floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring and with overall length of cover plate 150 mm, fixed in floor, complete all as specified and directed.
S&F in repair 300mm long mild steel ordinary quality rat rail rod pattern spring including roller plate complete fixed to steel surfaces including necessary welding complete all as specified and directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 250 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
Supply and Fix, stainless steel wire cloth, 0.36mm nominal dia. of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
Supply and Fix, in repair stainless steel wire cloth, 0.36mm nominal dia. of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F 20mm bore Stainless Steel drapery rods sheet of grade X02Cr19NilO (304 S2) , suitable for door/widows curtain with incl necessary fancy type dooms as approved by GE, and fitted to each end, with and inclding new Stainless steel brackets sheet of grade X02Cr19NilO (304 S2) and fixed to wall complete all as specified and directed.
S&F in repairs stainless steel bracket and holders for 25 mm dia curtain rod, made out of stainless steel sheet of grade X02Cr19NilO (304 S2), surface finish No. 4 as per IS 6911: 1992 complete all as specified and as directed.
S&F in repairs 40mm width and 5mm thick Door seal (Snake guard) with Aluminium frame powder coated complete all specified
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F for steel work of grade-3 as per IS 10748 in tubular trusses including special shaped washer etc. complete using ERW or HRIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade) complete all as specified and directed.
S&F Roof trusses (framed) trussed, purline crane gantries ,rails and fastenings and heavy brackeet framing (Beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W (Gde-E-250)quality-A complete all as specified and as directed.
Supply & Fixing for rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachment conforming to Fe:410-W(Gde-E-250 ) quality-A complete all as specified and directed.
S&F Mild steel screw bolts diameter of neck from 11 to 15 mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long all as specified.
Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height Complete all as specified and as directed.
Supply and fix mild steel TMT bars 6 to 8 mm dia., cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clipsand including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table and like over and including 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L Machine cut cudappah stone slab flooring 20-25mm thick over cement screed base in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
M&L for machine cut kota stone slab flooring 18-20 mm thick laid over cement screed base and jointed and pointed , grinding and polishing to obtain mirror finishes over and including 15 mm thick rendering in CM 1:4 complete all as specified and directed.
All as item No.75 above but as in riser of steps, skirting, dado and pillar laid over cement screed base and jointed with grey cement and pigment cement over and including 10 mm thick screed bed in CM 1: 3 complete all as specified and directed.
M & L for chequered cement concrete tiles chemically treated , cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 25 cm X 25 cm X 22 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 20 mm thick bedding of cement mortar(1:4) all as specified and as directed.
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 8 to 9mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm,conforming to IS 15622, Grade B II, in riser of steps, skirting, dado and pillar laid over cement screed base including 15 thick rendering Cement mortar (1:3) complete all as specified and directed
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 9 to 9 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm,conforming to IS 15622, Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified and directed.
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 9 to 9 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,conforming to IS 15622, Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified and directed.
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 9 to 9 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm,conforming to IS 15622, Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed.
Materials and Labour for, Digital glazed ceramic printed coloured tiles, 350 X 250 X 7-8mm thick, conforming to IS 15622, Grade B III, on vertical surface of wall such as dados,skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and directed.
Supply and lay 3 mm thick averaging Ready Mix adhesive including roughing and proper cleaning, wash with water to old surfaces and fill depression if any with Cement mortar 1:3 to give true surface complete all as specified and directed of Make : Pidilite (Roff)
Materials and Labour for for 25 mm thick plain cement concrete (1:2:4) type B1 using 20 mm graded aggregate as in sub base floor/paving/hardstanding complete all as specified and directed.
M & L 75 mm thick plain cement concrete M15(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protectionas / sub base floor/paving/hardstanding all as specified and as directed.
M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregatesas in plinth protection finishing even & fair without using extra cement laid in bays with construction, 6mm thick joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 gde and three part of sand ( all by weight) complete.
M & L 100 mm thick plain cement concrete M15 (Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as hadstanding/sub base/floor/path etc complete all as specified and as directed.
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
Materials and Labour for rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - Water proofing compound deemed to be inclusive rates
Materials and Labour for rendering 5mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface finished even and smooth using extra cement in walls/spetic tank/manholes/soakage pits etc, complete all as specified and directed. Note: - Note: - Water proofing compound deemed to be inclusive rates)
Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces (on ceiling/soffits surfaces) in cement mortar 1:3 finished even and fair complete all as specified and as directed.
Preparing surface of sunken slab and applying 15 mm thick cement plaster 1:4 cement sand mortar with integral water proofing compound both on floor and wall. including , laying and testing of elastomeric bituminous coating system based on bituminous emulsion, polymer and additive conforming to ASTM C 836 (“Dr. Fixit Solyseal" or equivalent of M/s Fosroc, M/s STP Limited) over the substrate including application of one coat of primer (solyseal 1 : water 1) followed by two coats of solyseal applied @ 0.90 kg/sqm/coat sandwiched with open woven glass fibre of mesh 2 mm X 2 mm or PE based spun bound fabric of 40 gsm complete as per manufacturer specification in sunken portion with and including sunken floor shall be filled with PCC 1:3:6 as per existing thickness complete all as specified.
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated any approved profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.(Tata bluescope/Sexena Marine Tech/JSW or equivalent make)
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.(Tata bluescope/Sexena Marine Tech/JSW or equivalent make)
Materials and Labour for for complete removal of existing treatment by mean mechincal machine as per manufacturer instuction,s applying two coats of interior emulsion paint silk glamor brand or equivalent any shade and colour to old plastered surfaces on walls, over and including 1mm thick wall care putty premium quality over priming paint as manufacturer,s intruction and including preparation of surfaces, complete all as specified and directed.Note Work shall be executed through authorised applicator of manufacturer,s paint Paint manufacturer Make Berger(Silk luxury)/J&N Special effect Insta colour/Asain(Royale)/Nerolac(Impressions)
M&L for preparation of newly plastered surfaces of walls, and applying two coats acrylic distemper on wall ,over and including with a coat of 2 mm thick white wall care putty premium quality over and including a coat of primer new plastered or unplastered surfaces on wall, complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M & L for applying Two 100 % Acrylic Exterior Emulsion paint as approved pattern (Three colours as approved by GE) (Berger,Weather coat Advanced XP long life Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand over a coat of exterior wall primer on new concrete/wall over and including 2mm thick external wall putty in two layer surfaces up to 10 Mtr height including all necessary scaffolding and safety measures complete all as specified and directed.
Material and Labour for complete removal of existing treatment by means mechnical process / Machine as directed by manfucaturer through authorised applicator of manufacturer,s and applying two coat of 100 % Acrylic Exterior Emulsion paint in c(Berger,Weather coat Advanced XP long life Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand painting over and including a coat of primer to old plastered or unplastered surfaces over and including 2mm thick external wall putty in two layer up to 10 Mtr height including all necessary scaffolding and safety measures complete all as specified and directed.
M&L for preparing old decorated plastered or unplasterd surfaces of ceiling including cornices, pilasters and other wall features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying two coat of white washing on the ceiling all as specified and directed
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying two coat of white washing on the wall all as specified and directed
M&L for preparation of new plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed.
Preparation of new steel surface of any description exceeding 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge
M&L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of new or previously undecorated wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of Pink primer complete all as specified and as directed.
M&L Writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30 cm high complete all as specifed and as directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, fixed to walls incuding mild steel clamp not more than 1metre C/C complete all as specified and directed by Engineer- in- charge .
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches, wall and floor including all fitting complete all as specified and directed by Engineer- in- charge .
S & F UPVC bends with inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F UPVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F UPVC bends with inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F UPVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S&F 110 mm bore UPVC branch piece single (Single `Y'/'T') equal or unequal without access door complete all as specified and directed by Engineer- in- charge
S&F 75 mm bore UPVC branch piece single (Single `Y'/'T') equal or unequal without access door complete all as specified and directed by Engineer- in- charge
S&F 75 mm bore PVC (SWR) Vent Cowl complete all as specified and directed by Engineer- in- charge
S&F 110 mm bore PVC (SWR) Vent Cowl complete all as specified and directed by Engineer- in- charge
Supply and fix PVC SWR Nahani/ Floor trap, multi inlet connection, plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge.
M & L for PVC (SWR ) gully trap 125/110 mm with grating or without grating and jointing with solvent cement and fixed in position complete all as specified and directed including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Supply and fixing of Grating round 125 mm size of PTMT. (Minimum weight 50gms) complete including jointing with solvent cement, all as specified & as directed.
Supply and fixing of Grating round 125 mm size of PTMT. (Minimum weight 50gms) with waste ho;e complete including jointing with solvent cement, all as specified & as directed.
S & F brass chromium plated shower rose 125 mm size with or without swivel joints with shower arm, any size, including fixing to steel pipe or union complete all as specified and as directed.
S&F in repairs health faucet brass chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall 1.25 m long flexible tube and brass wall hook including making connection and fixed in position complete all as specified & as directed.
S&F in repairs toilet paper holder with flat recessed type stainless steel complete all as specified and directed
Supply and Fix in repairs, brass chromium plated soap dish, ., fixed with brass chromium plated screws, complete all as specified and directed. (Make Jaquar Cat part No. AQN-7731/Marc/Kohler)
S & F flexible (coil shaped) PVC waste pipe for sink and wash basin 32 mm dia with length not less than 900 mm connected to PVC waste fittings complete all as specified and as directed.
S & F flexible (coil shaped) PVC waste pipe for sink and wash basin 40 mm dia with length not less than 900 mm connected to PVC waste fittings complete all as specified and as directed.
M & L for PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
S & F sinks with drainage board made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers and 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes overall size 915 mm X 460 mm bowel size 410 mm X 330 mm X 160 mm complete all as specified and as directed.
Fixing only in repair sinks with and including providing new plugs, washers and 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes complete all as specified and as directed.
S&F Kitchen stainless steel plate rack (24" X 24" X 10") including necessary fixing / fittings & making good the existing surfaces complete all as specified and directed. Make Prayag Cat No P-310 or equivalent as per PS
S&F 500 ltrs IS marked multilayer rotational moulded polythytene water storage tanks (cylindrical vertical with closed top) as per IS 12701: 1996hoisted and fixed in position with and including 20mm brass ball valves high pressure with polythene float and nut with and including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes including dismantling exsiting one complete all as specified and directed .
S & F in repair 20 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
S&F in repair Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed .
S&F in repair Gun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed .
M&L for disconnecting existing tank setting aside for repairs, including cleaning of service PVC tank by rubbing vertical wall and bottom of with bleaching powder and allowed ½ hour to react and then washing down with water to get free from deposits and bleaching inside the tank of capacity and mouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc.300 and not exc. 500 ltrs complete all as specified & as directed. Note : Spare part required to be replaced up to Rs 200 deemed to be included in quoated rates.
S&F in repairs PVC tank cover with locking arrangement for 500 ltrs to 1000ltr capacity of approved make complete all as specified & as directed.
Supplying & fixing to walls, ceiling and laid in trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls , ceiling and laid in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Material and labour for laying of GI tubing 50 mm bore, medium grade, ISI marked, conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 like elbow, socket, tee, reducer, nipple, short piece, union etc as required at site and walls , ceiling and laid in trenches incl connecting with existing lines all as directed by Engr-in-charge. Note:(i) Union or long screw have to provided at starting / end point of jointing pipe line . (ii) Contractor has to submit the test certificate and purchase voucher of pipes before claiming payment.
Material and labour for laying of GI tubing 25 mm bore, medium grade, ISI marked, conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 like elbow, socket, tee, reducer, nipple, short piece, union etc as required at site and walls , ceiling and laid in trenches incl connecting with existing lines all as directed by Engr-in-charge. Note:(i) Union or long screw have to provided at starting / end point of jointing pipe line . (ii) Contractor has to submit the test certificate and purchase voucher of pipes before claiming payment.
Material and labour for fixing GM globe/gate valve 25 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS including taking down old unserviceable complete all as specified and directed by Engr in charge. Make : ZOLOTO / LEADER or equivalent make Note: Union or long screw have to provided before fixing of gate valve. (ii) Contractor has to submit the test certificate and purchase voucher of valves before claiming payment.
Material and labour for fixing GM globe/gate valve 20 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS including taking down old unserviceable complete all as specified and directed by Engr in charge. Make : ZOLOTO / LEADER or equivalent make Note: Union or long screw have to provided before fixing of gate valve. (ii) Contractor has to submit the test certificate and purchase voucher of valves before claiming payment.
Material and labour for fixing GM globe/gate valve 15 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS including taking down old unserviceable complete all as specified and directed by Engr in charge. Make : ZOLOTO / LEADER or equivalent make Note: Union or long screw have to provided before fixing of gate valve. (ii) Contractor has to submit the test certificate and purchase voucher of valves before claiming payment.
Refixing of old steel tubing and connection with new fittings conforming to IS 1239 (Part-2): 2011 in new or old position (wall, ceiling, floors, etc) of 15 mm bore complete all as specified and as directed.
Refixing of old steel tubing and connection with new fittings conforming to IS 1239 (Part-2): 2011 in new or old position (wall, ceiling, floors, etc) of 20 mm bore complete all as specified and as directed.
S&F in repairs vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs vitreous china squatting pan, 'Orissa" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S” trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs in repairs thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating complete all as specified and as directed.
S&F in repairs 15 mm nominal size, Swan Neck Pillar Cock , cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish all as per catalogue No.T4668A1 of Make Parryware or equivalent of Make mentioned under PS complete all as specified and as directed.
S&F 15 mm nominal size, Swan Neck Pillar Cock , cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish all as per catalogue No.T4668A1 of Make Parryware or equivalent of Make mentioned under PS complete all as specified and as directed.
Supply and Fix in repair, brass chromium plated, towel rail, 20mm dia, , 60cm long between flanges, complete all as specified and directed.Make Cat no.ACN-1111NM of Jaquar or equivalent of Marc/Kohler
Supply and Fix brass chromium plated, towel rail, 20mm dia, , 60cm long between flanges, complete all as specified and directed.Make Cat no.ACN-1111NM of Jaquar or equivalent of Marc/Kohler
S & F in repairs 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993, two ways in double control, made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
Supply and Fix in repair, bib tap, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,15 mm bore and fixed, complete all as specified and directed.
S & F in repair 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F in repair 15 mm nominal size, nonrising spindle type fancy angle cock as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed.
Supply and Fix, brass CP fancy wall mixer with L bends (including provision of O/H shower & hand shower) for mixing hot & cold water screwed down for iron pipe 15 mm bore and fixed, with including hand shower and tube inlcuding taking out unserviceable existing one complete all as specified and directed.
Supply and Fix, brass CP fancy centre hole basin mixer for mixing hot & cold water screwed down for iron pipe 15 mm bore and fixed, with including hand shower and tube inlcuding taking out unserviceable existing one complete all as specified and directed. (Make mixer cat part no. QQT-7169B of Jaquar or equivalent make Kohler/Marc)
S & F in repair 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
S & F in repairs wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
Fixing only in repairs wash basins, vitreous china, of any decription and size with and including providing new cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
S & F 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant complete all as specified and as directed.
M&L, brick work with sub class 'B' bricks (old size) having water absorption upto 10%, straight or curved on plan, exc. 6 metre mean radius built in cement mortar 1:6 as in manholes, septic tanks, soakage pits etc in any position complete all as specified and as directed.
Supplying, installing, testing & commissioning, storage water heater (geyser), 25 litres capacity, standing loss less than 0.562 Kwh per day for 45⁰C difference of temperature as per IS 2082 (five-star rated as per BEE), reheating time less than 60 minutes, mixing factor less than 20%, shock proof high density PUF insulation body material, glass lined inner tank material having warranty 7 years on tank material, 4 years on heating element and 2 years on other spares parts comprising following fittings (a) glass coated incoloy element (b) capillary type thermostat (c) digital display unit (d) thermal cutout (e) multifunction valve (f) earth leakage circuit breaker (g) magnesium anode rod cathodic protection (h) flexible cable of suitable length with 3-pin plug of 16A capacity (i) drain plug (j) fusible plug fitted on the crown of water heater with operating temperature between 100⁰C to 110⁰C including fixing by grouting and fastener complete all as specified and as directed.Make JAQUAR/USHA/AO-SMITH or Equivalent make NOTE :- (i) Contract shall submit the brochure of geyser with detail technical specification and take approval of GE before procurement. (ii) All civil work required on site for hanging the geyser and to make good to match the surface as existing to be done by contractor without any extra cost. (iii) All the necessary accessories and T&P require on site for installation of geyser shall be provided by contractor. (iv) Contractor shall submit the manufacturer warranty card to the department before claiming payment to department. (v) If extra cable (PVC insulated sheated 2.5 Sqmm x 2 core copper conductor) required on site for extension of electric supply connection from Geyser to Metal Plug socket the same (upto 3 mtr) shall be provided by the contractor without any extra cost.
M & L for cutting existing steel tubing for alterations or additions in position without taking down of pipe complete all as specified and directed (Note cutting of existing pipe to be done for insersation of geyser cold water inlet connection pipe.
M & L for screwing existing steel tubing or alterations or additions in position without taking down of pipe complete all as specified and directed
S & F stainless steel braided flexible connection pipe for hot and cold water supply for geyser, 15 mm bore, 600 mm length, 12 bar working pressure complete all as specified and as directed.
Taking down carefully (copper/aluminium) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators sub main wiring, light fittings etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
M & L for concealed point wiring with and including single core PVC insulated, unsheathed flexible conductor (FRLSH) cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor (FRLSH) cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule. (a) One fan point/Exhaust fan point controlled by one switch 5 Amps
All as per item No. 172 above but one 3 Pin 5/6 Amp socket outlet on independent board
All as per item No. 172 above here in before but one 3 Pin 5/6 Amp socket outlet on same board
All as per item No. 172 above here in before but one light point controlled by one way switch 5/6 Amps.
All as per item No. 172 above here in before but one bell point controlled by one way switch 5/6 Amps.
All as per item No. 172 above here in before but one light point controlled by two way switch 5/6 Amps.
All as per item No. 172 above here in before but wiring with 2.5 sq mm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed
Materials and Labour for concealed type point wiring with 4.00 Sq. mm (nominal area) (FRLSH) as per IS 694: 2010, ISI marked PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, drawn in and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switch socket outlet etc and including 4.00 Sq. mm (nominal area) (FRLSH) PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one metal plug & socket for AC or one socket for geyser, complete all as specified and directed.(Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule.
S&F of Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F of Modular switch, single pole, Two way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F of Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F of Modular shuttered Socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and as directed.
S&F of Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and as directed.
S&F of Modular bell push, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F modular electronic fan regulator 120 watt 2 module suitable for 1200/1400 mm sweep energy saving fans,ISI marked complete all as specified and directed.
S&F Modular metal flux box 6 module incl taking down old complete all as specified and directed
S&F Modular metal flux box 4 module incl taking down old complete all as specified and directed
S&F Modular metal flux box 3 module incl taking down old complete all as specified and directed
S&F Modular metal flux box 2 module incl taking down old complete all as specified and directed
S&F Modular white cover plate with frame 6 module incl taking down old complete all as specified and directed
S&F Modular white cover plate with frame 4 module incl taking down old complete all as specified and directed
S&F Modular white cover plate with frame 3 module incl taking down old complete all as specified and directed
S&F Modular white cover plate with frame 2 module incl taking down old complete all as specified and directed
S&F Bell ,Ding dong type electric AC, 230V, Single phase,complete all as directed by EIC.
S&F Polycarbonate angular lamp holder with back plate, suitable for LED Lamp fittings all as specified and directed by EIC including taking out old u/s.(Note : Item to be measured if executed under new point wiring)
S&F LED bulb 9/10 watt with B22 base, 1100 lumen, 6500 K including taking out old unserviceable complete all as specified and directed by EIC.
S&F ceiling Rose, surface,bakelite 65mm polycarbonate three terminals, AC, 230 Volts complete all as specified and directed by EIC.
S&F LED 20 Watt tube light fitting intregated type, including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 120 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battens life span of minimum 50000 working hours r complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed. . Note : Make of batten and LED tube lamp should be of same make.
Fixing only in repair LED Tube light of any watt on wall/surface mounted fixed with 02 Nos of PVC round/ square blocks, screws etc complete all as specified.
S&F in repair LED 9/10 Watt tube light fitting intergated type, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 120 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, ATHD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing life span of minimum 50000 working hours complete suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.5 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed.
S & F LED bulkhead light with pressure die-cast housing light fittings nominal power 10/12 watt LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of lumen efficacy of minimum 120 lumens per watt , , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 housing with aluminium, life span of minimum 50000 working hours complete all as specified and as directed..
Fixing only in repair bulkhead light of any watt on wall/surface mounted fixed with 02 Nos of PVC round/ square blocks, screws etc complete all as specified.
S&F of Decorative wall light fixture made up of polycarbonate suitable for 15 Watt LED retrofit of type B-22 base, IP66 grade, with and including 15 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete incl removal of old unsv fitting all as directed by Engineer-in-Charge.
Taking down ceilling fans/Exhaust fan, sealing cable end, including painting of fan with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc. and repositioning & hanging ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as directed by engineer in charge.
Material and labour for concealed sub-main wiring alongwith earth wire of size of 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, including taking down old unsv aluminium submain wiring all as specified and as directed. NOTE : Two runs of 6 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
Material and labour for concealed sub-main wiring alongwith earth wire of size of 6 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, including taking down old unsv aluminium submain wiring all as specified and as directed. NOTE : Four runs of 6 sqmm conductor for main and as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
S & F of MCB, DB Vertical TPN, 415 volts 4 ways (8+18 WAYS), DOUBLE DOOR, IP-43, with MCCB Incomer, metal door, rated bus bars, earth bar, neutral links complete incl. blanking plates as required & fixed flush to wall/other surface complete all as specified and as directed.
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, 415Volt IP-20 protection suitable for fixing MCB"S/lsolators with and including taking down old one complete all as specified and directed.
S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, ertth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and as directed.
Supply and fixing of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 125 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F MCB, Triple pole & neutral 63 amps, 415 volts, ‘C’ curve, 10KA complete all as specified and as directed.
S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one as specified and as directed.
S&F MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unsv one as specified and as directed.
M & L for sheet metal enclosure fabricated out of 2.0 mm thick CRCA sheet, totally enclosed type, dust & vermin proof, with suitable sized supporting MS angles & suitable openings at top & bottom for entry of outgoing / incomming cables, fixed with nuts & bolts & front side openable with hinged shutter with suitable locking arrangement duly painted with 2 coats of powder coated paint over a coat of red oxide primer (spray paint) with minimum dimensions (90 x 75 x 20 cm ) flush to wall for incorporating 01 No TPN DB, 04 Nos electronic meters etc complete all as specified and as directed.
S&F exhaust fan with louvers 300 mm sweep steel body, energy efficient, AC single phase 240 volts, 50Hz connecting up complete including making holes and plastering the disturbed surfaces to make smooth and built in louvers and provision of 3 core flexible multistranded copper conductor of size 0.75 Sqmm from ceiling rose to fan all as specified and as directed.
S&F exhaust fan with louvers 250 mm sweep (Plastic rust proof Body and blade), energy efficient, AC single phase 240 volts, 50Hz connecting up complete including making holes and plastering the disturbed surfaces to make smooth and built in louvers and provision of 3 core flexible multistranded copper conductor of size 0.75 Sqmm from ceiling rose to fan all as specified and as directed.
S&F epoxy powder coated sheet metal enclosure with socket plug top and MCB, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps, 240 Volts, C Series current carrying capacity 10 kA, incl necessary connection complete all as specified and directed.
Taking down Electric meter single phase any capacity/size disconnecting electrical connections and refixing the same all as directed
Taking down Electric meter three phase any capacity/size disconnecting electrical connections and refixing the same all as directed
Horizontal boring of holes by mechanical means, at under road/ pavement / hard standing etc.,not exceeding 15 Metres in length, in any type of soil, suitable for passing through 50 mm bore, galvanised steel tubing,and making good distrubed surfaces as per existing specification complete all as specified and directed. Note : GI pipe of dia 50mm will be measured & paid separately under respective items.
Material and labour for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including all fitting clamps, nut, bolt and washers complete all as specified and directed.
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 250 Amps and 36 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In,complete all as specified and directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3.5 core with reduced neutral conductors (3.5 core), nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors/wall, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
S&F for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.3 of MES SSR parts-I and including excavation & earth work in any type of soil/stone ,disposal of soil , providing alternate layers of charcoal and common salt, refilling of pit with agriculture soil, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-1 cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion,including taking out old u/s complete all as specified and directed. Note: (i) Unit rate of earthing deemed to be included with GI wire 4 mm, GI pipe light grade protection pipe 15 mm up to 7.5 RM) (ii) Since the resistivity of soil is high contractor shall bring the agriculture soil from out side defence land to fill the earth pit.
Guru Charan Mahata
BHOWMICK ENTERPRISES INDIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .