Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAccepted-AOC NO 25 9 DR NATESAN ROAD 1ST LANE TRIPLICANE CHENNAI 05 | CHENNAI | TAMIL NADU | 600005 | ₹2.5 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹2.6 Cr+₹5.9 L (2.36%)Rejected-AOC | ₹2.6 Cr+₹5.9 L (2.36%) | L2 | Rejected-AOC Rejected |
Tender Value
₹2.5 Cr
EMD Value
₹1.4 L
Closing Date
2 Apr 2024, 3:00 pmClosed
Chief Engineer
Office of Chief Engineer, Sardar Patel Road, Dote Campus, Chennai 25
Construction of Digital Library building in Lady Willington Institute of Advanced study in Education,Chennai 5
2024_HE_449070_1
LadyWillington_2024
Open Tender
Civil Works
Lump-sum
210 days
Chennai
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹1.4 L
Yes
29 Nov 2024
15 Mar 2024
3 Apr 2024
15 Mar 2024
2 Apr 2024
15 Mar 2024
Amount
Earthwork excavation for foundation in all soils and sub soils to full depth as may be directed except in hard rock requiring blasting inclusive of shoring shuttering, baling out water wherever necessary, refilling the foundation with excavated earth and depositing the surplus earth within compound in places shown by the departmental officers with an initial lead of 10 metre and initial lift of 2 metre and clearing and leveling the site etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and Filling in foundation and basement with filling m sand in layers of not more than 15cm thick well rammed watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and filling in foundation and basement with Stone Dust in layers of not more than 15cm thick well rammed watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
Refilling basement with excavated earth other than sand with an initial head lead of 100 mts. and depositing the earth as shonw by the departmental officers in layers of not more than 15cm thick well rammed, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers..
Cement concrete 1:5:10 (one cement, five M sand and ten aggregate) using 40mm gauge hard broken blue granite stone jelly for foundation and basement including dewatering if found necessary and laid in layers of not more than 15cm thick and compacted etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) For column footing plinth beam etc.
Supplying and erecting steel centering including necessary supports for plain surfaces, for all RCC works including strutting upto 3.29m in all floors using mild steel shutters of size 90cmx60cm of BG 10 stiffened with mild steel angles of size 25mmx 25mmx3mm laid over silver oak (Country wood) Joists of size 10cmx6.5cm spaced at about 90cm c/c and supported by casurina props of 10cm to 13cm dia. (spaced at 75cm c/c) etc., complete complying with standard specification and as directed by the departmental officers. (The centering will be removed after specified period of concrete without damaging the concrete)
For plane surface such as RCC floor slab, roof slab, beam litels bed blocks, landing slab, waist slabs and beams, etc.,
For plane surfaces such as RCC square or rectangular column, top and bottom slab of sunshade, boxing sill etc. complete as directed
For plane surface such as Vertical surfaces such as sunshade, boxing vertical drops, facia for sunshade and other vertical walls etc.,
Providing additional strutting using casurina poles to centering of RCC slabs or plane surfaces for every addtional 1 metre height or part there of but not less than 30cm over the initial height of 3m from floor level using casurina props of 10cm to 13cm dia including cross bracings etc., complete complying with standard specification and as directed by the departmental officer.
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance using with IS:456-2000, 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of m sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
For foundation and basement
In Superstructure in Ground floor
In Superstructure in first floor
In Superstructure in second floor
Supplying, fabricating and placing inposition of steel reinforcement using MS/Ribbed tor steel rods for all RCC works as per the design given including cost of steel and G.I binding wire also in all floors etc., complete complying with standard specification and as directed by the departmental officers.. ( The contractor will have to make his own arrangement for the supply of M.S plain rod/ RTS rod and black binding wire )
Brick work in cement mortar 1:6 (one cement and five M sand) using Fly Ash bricks of size 230×110×70mm including curing etc., complete complying with standard specification and as directed by the department officers. (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost).
For foundation and basement
For superstructure in ground floor
For superstructure in first floor
For superstructure in second floor
Brick work in cement mortar 1:5 (one cement and five M sand) using Fly Ash bricks of size 230×110×70mm including curing etc., complete complying with standard specification and as directed by the department officers. (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost).
For foundation and basement
Brick partion wall 11.10cm thick in cement mortar 1:3 (one cement and three M sand) using Fly Ash bricks of size 230×110×70mm including fixing hoop iron reinforcement if found necessary, laying, finishing and curing etc., complete complying with standard specification and as directed by the departmental officers.
For superstructure in ground floor
For superstructure in first floor
Special ceiling plastering and finishing all reinforced cement concrete exposed surface such as reinforced cement concrete slab, sunshades, staircase steps landing slab with cement mortar 1:3 (One cement and three p sand) 10mm thick including hacking the surface and providing necessary cement mortar nosing beadings wherever necessary using the same mortar as directed by the Departmental Officers complete complying with standard specification.
Plastering with cement mortar 1:5 (one cement and five p-sand) 12mm thick in all floors using fine river sand including neat finishing, curing, etc., complete complying with standard specification and as directed by the department officers.
Plastering with cement mortar 1:3 (one cement and three p sand) 12mm thick with WPC 2% by weight of cement used in all floors using fine river sand including neat finishing, curing, etc., complete complying with standard specification and as directed by the department officers.
Providing mixing laying polymer based water proofing treatment for the sunkan toilet by applying cement based fiexable WPC conforming to IS 2645 to a thickness of 1mm of the prepared surface of the roof slab / floor slab as per specification mendioned above providing cm 1:3 water proofing cover plaster to a thickness 12mm. The malaime coating with admixture of approved make rate quoted is inclusive of preparation of surface which including cleaning of surface polymer morter, curing, labour, tools equipments etc., rate inclusive of cement and sand required for the treatment the coat and labour charges for fixing 25mm dia pressure pipe 15 kg / m2 to length of 45 cm for drip pipe etc., complete complying with standard specification and as directed by the departmental officers..
Paving the floor with Stain free nano polished vitrified tiles (like Marbonite or equivalent) of approved quality and colour of size 600 x 600x 8 mm thickness in all floors over a base layer of cement mortar 1:3 (one cement and three M sand) 20mm thick and pointing with white cement using 0.30kg/m2 including adding suitable colour pigments to suit the colour of tiles finishing perfectly and curing etc., including cost of tiles, all materials and incidential charges, transportation charges and labour charges for laying tiles etc., complete complying with standard specification and as directed by the Departmental officers. (The tiles should be got approved by the Departmental officers before use on works).
Paving the floor with best approved quality fine polished Jet Black Granite Slabs of size 1200 x 600 of 16 / 18mm thick and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Labour charges for finishing the top of working tables and staircase step portion with nosing arrangements in Granite slab tiles including cutting the edges and polishing including cost of polishing materials complete complying with standard specification and as directed by the departmental officers.
Paving the floor with colour design ceramic tiles of approved quality and colour of size 305 x 305 x 6mm in all floors over a base layer of cement mortar 1:3 (one cement and three m sand) 20mm thick and pointing with white cement using 0.30kg/m2 including adding suitable colour pigments to suit the colour of tiles finishing perfectly and curing etc., including cost of tiles, all materials and incidential charges, transportation charges and labour charges for laying tiles etc., complete complying with standard specification and as directed by the departmental officers . (The tiles should be got approved by the departmental officers before use on works).
Dadooing the walls with colour design glazed tiles of size 300mmx 450mmx 8mm of approved quality in all floors set in cement mortar 1:2 mix (one cement & two M-sand) 10mm thick and pointing with white cement using 0.4 kg/m2 including adding suitablee colour pigments to suit the colour of tiles including finishing the joints neatly and curing etc.,complete complying with standard specifications. (The tiles should be got approved by departmental officers before use on the work).
Brick Jelly Lime Concrete of 1:2:5 (One Lime,Two m Sand and Five Brick jelly ) with 40 mm hand broken brick jelly for Sunken portions including dewatering wherever necessary and laid in layers of not more than 15cm thick, well rammed, consolidated and curing etc. complete complying with standard specification.
Weathering course using best quality of broken brick jelly of 20mm gauge in pure slacked lime (no sand to be added) the proportion of brick jelly to lime being 32:12.5 Cft. by volume and laid over the RCC roof slab in a single layer and consolidated to the required design and finished thickness and slope by beating the concrete with wooden beater of approved pattern and keeping the surface constantly wet by sprinkling lime jaggery water etc., complete complying with standard specification and as directed by the departmental officers.
For superstructure in first floor
Finishing the top of roof with one course of Machine pressed tiles of size 23×23×2cm of approved quality laid in cement mortar 1:3 (One cement and three M-sand) 12mm thick mixed with water proofing compound (confirming to Indian standard specification) 2% by weight of cement used and pointed with the same mortar including mixing of red oxide and water proofing compound etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Fabricating supplying and fixing in position CRCA pressed steel box section 18 gauge or 1.25mm thick for door frames of section size 105mmx60mmx1.25mm thick with necessary rebate of size 35x15mm for housing door shutters conforming to IS specification. Frames shall be fabricated to the specified door size with joints properly welded and grinded. Stiffeners with 25x3mm MS flat shall be provided around the frame at 60cm intervals. The cost shall also include for providing 3 Nos. of MS clamps with 25x3 flats each on either sides of door frame, providing bottom tie, with 10mm dia MS rod, providing necessary holes for receiving tower bolts 2 Nos. with stiffeners on inner side, providing the required number of I.O hinges of size 125x30mm for shutters properly welded to the frames, finishing the door with one coat of good quality red oxide primer with cement concrete 1:2:4 (One cement, two sand and four aggregate) using 20mm gauge hard broken granite stone jelly packed inside to the frame including cost of all materials, fabrication and conveyance to the site and fixing in position with necessary scaffolding etc., complete complying with standard specification and as directed by the departmental officer.
Supplying and fixing in postion of 35mm thick solid core flush door shutters with following specification. with Commercial ply on both sides and with TW lipping of size 35x12mm on all edges with necessary adhesives and C.P. Screws Alu. Butt Hinges (6 nos. 250 x 16 mm Size) Alu. Aldrop1 No. 250 x 16 mm Size, Alu. Tower Bolt 2 No. 250 x12 mm size, alu. Tower Bolt 2 No. 200 x 12 mm size, D type alu. Handle 200mm length 2 No., alu. door stopper with rubber bush 2 No. shall be provided, complete complying with standard specification and as directed by the departmental officers.
Single Leaf
Double leaves
Supply and Fixing of M.S. steel doors with Single Leaves following specification. MS angles of size 40x40x 6mm at 3.5 kg/m used for the outer frame and MS angles of size 35x35x5mm at 2.60 kg/m for the shutter frames. Stiffners with 32x6mm at 1.50 Kg/m. MS flat is provided as the lock rail of the door and welded infact of both ends to the shutter frame, 18 gauge CR sheets of best quality is laid as panel in the shutter frames. 18x5mm at 0.70 kg/m MS flat is welded over the 32x6mm at 1.50 Kg / RM and MS flat on the rear side of the door sandwitching the CR sheet for rigidity with locking rail and bottom tie arrangements. Additional stiffners with 18x5 mm at 0.7 kg/m MS flats are provided horizontally diagonally on the rear side of the shutter. 2Nos of hinges in case of single leaf and 4Nos of hinges in case double leaf shutter is provided 6 Nos of hold fasts 200 length 40x40x6mm M.S. angle spliced at the ends are welded to the outer frame of the door. Tower bolt 2 Nos. one at top and the other at bottom are provided. One aldrop is provided incase of double leaves door at lock rail section in the door. For single leaf doors, one more aldrop is provided in the inner side at the lock rail section of the door.
One rotating locking arrangements at the inner side of the door and additional provision for locking arrangements for lock is provided with 32x6mm MS flat on the rear side of the door at an appropriate place incase of a double leaves door MS flat 32x6mm at 1.50 kg/m is provided on the edge of one shutter to conceal the gap between the shutters. A tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation of fixing. All members are given a shop coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials labour charges transportation taxes and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers..
Supplying and fixing 30mm thick solid core PVC door shutter with PVC frame of size 50x45mm with suitable rebate for housing the shutter consisting of frame made out of MS tubes 19 gauge thickness and size of 19x19mm for styles and 15x15mm for top and bottom rails, MS frame shall be covered ith 5mm thick heat moulded PVC 'C' channel of size 30x50mm forming styles and 75x50mm for top rai8l, lock rail and bottom rail on either side and 10mm thick 20mm wide cross PVC sheet as gap insert for tap rail, botytom rail, panelling of 5mm thick PVC sheet bearing on either side and join together other side etc. An additional 5mm thick PVC strip of 20mm width is to be stack and the interior side of the 'C' channel using PVC sealant adhesiv e including cost of all furniture fittings, such as aluminium aldrop of size 250x16mm -1 No. aluminium tower bolt 250x12mm-1 No. aluminium D type handled 200mm etc. complete complying with standard specification and as directed by the departmental officers.
Manufacturing, Supplying and fixing Stainless Steel hand rail for staircase using 50mm dia 304L Grade stainless steel pipe of 1.60mm thick at at required locations to a height of 1000mm from finished floor level welded to 38.30 mm dia stainless steel pipe post of 1.00mm thick as vertical at 900 center with 3nos of 25.40mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100x100x6mm MS base plate encased in the base concrete. The rate is inclusive of charges for cutting , bending , welding , grinding polishing conveyance, electrical charges , etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing MS grills to doors, windows and ventilators etc. using necessary MS flats (or) square rods for inner members and outer members which should be fixed to window frames as directed and design given by the departmental officers inclusive of cost of providing one coat of best quality red oxide primer etc., complete complying with standard specification and as directed by the departmental officers .
Supplying and fixing in position best approved of ISI quality of following dia PVC rain water down fall pipes having a working pressure of 4 kg / sq.cm including cost of necessary PVC shoe, PVC bend, C.I. gratings of required dia. and special clamps, brass screws, nails etc., and fixing of cast iron gratings at juction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cost of removable iron grating. The PVC pipe shall be fixed on wall with special type of clamps. Special type "U" clamp at the centre of the pipe line shall be fixed in addition to those for more than 3.0M pipe length complying with standard specification and as directed by the departmental officers..
110mm dia of PVC pipe
Supplying and fixing ornamental Brass-in-lay Burma Teak Wood Entrance Door with a size of2.10m x 2.55m with six leaves as per the drawing and design as approved by the departmental officers. The clear opening of each door shall be of 2.00m. The outer frames are of finished size 175mm x 125mm.The Each door shall have two leaves of 1/3 paneled and 2/3 glazed. The Outer frame of the shutter of finished size of 150mm x 50mm.All the Panels shall be of finished 50mm thick. The main outer frame, shutter frame and panels shall be engraved with computer design ornamental carving works of approved pattern with skilled carpenter as directed by departmental officers. All the glazing works shall be done with design painting works. Necessary grill protection arrangements shall be made for the glass portion. The door frame and shutters shall given two coats of best and approved quality of high Glossy Polyurethane finish. The rate includes cost of best and approved quality of Burma Teak wood, design painted glass, Brass hinges, Tower bolts, Aldrop, locking arrangments, ornamental handles, brass screws and labour charges, transportation charges, all taxes, etc., complete and complying with standard specification and as directed by the departmental officers .
White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed by the departmental officers..
Painting the walls two coats with best Oil bound distemper of approved quality (to be approved by the Executive Engineer before use on works) over one coat of primer for newly plastered wall including preparation of surface and finishing neatly including cost of all materials, brushes, scaffolding charges etc., complete complying with standard specification and as directed by the departmental officers.
Painting the exterior walls surface two coats of best and approved first quality and colour of Exterior emulsion paint in all floors over one coat of primer including preparation of surface, wall putty two coats with good quality including cost of wall putty , emmary sheet, plates, etc. and including labour charges for rubbing the wall scrapping putty pasting works and making good smooth surface and finishing neatly etc., . complying with standard specification and as directed by the departmental officers etc. complete. ( The make, quality and colour of paint should be got approved by the departmental officer before use of work)
Painting the new iron work with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat and including cost of painting materials, brushes, putty, preparation of surfaces and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officer. (The quality and colour of paint should be got approved by the departmental officer before use on work).
Finishing the top of flooring with granolithic floor finish of 25mm thickness with plain cement concrete of mix 1:2:4 (One cement, two M sand and four aggregate) using 20mm / 10 to 12mm ISS gauge hard broken granite stone including finishing the top smooth and forming thread lining and curing etc., complete complying with standard specification and as directed by the Departmental officers
Supplying and Fixing RCC precast slab in reinforced cement concerete 1:2:4 (One of cement, two of sand and four of aggregate) using 20mm hard broken stone jelly and river sand, excluding the cost of reinforcement grills and including fabrication charges, moulding, curing, finishing charges and fixing in position neatly etc., complete complying with standard specification and as directed by the departmental officers.
50mm thick
Supplying and fixing in position Indian water closet oriya type of size 580x440mm white glazed earthernware of approved quality with 'P" trap or 'S' trap conforming to IS 2556-Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to PVC. pipes by dismantling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specification and as directed by the departmental officers.(The Oriya type Water Closet and all accessories should be got approved by the departmental officers before use on work)
Supplying and fixing in position White Glazed European water closet of best quality and approved make with 100mm P or S trap with double flapped rigid PVC.seat cover with chromium plate brass hinges, including supplying and fixing PVC. Low level flushing tank 10 litre capacity of approved quality on wall with teak wood plugs, brass screws and 2 numbers 15mm dia gun metal wheel valve, 15mm dia nylon connection and giving necessary water supply connection as directed by the departmental officers. The rate includes cost of 100mm dia PVC.Pipe 60cm long including cost of 3 Kg.of white cement 6Kg.of cement, spunyarn, shellac, thread ball, teak wood plugs, brass screws 75mmx10mm etc., complete complying with standard specification and as directed by the departmental officers. (The European Water Closet and flushing tank should be got approved by the Departmental Officers before use on work.)
Supplying and fixing in position best quality of approved make white glazed earthernware wash hand basin (without pedestal) of size 550x400mm with a pair of cast iron brackets , including cost of 15mm diametre brass chromium plated pillar tap, 32mm diametre C.P.waste, 32mm diametre PVC waste pipe with rubber plug and chain, 15mm diametre gun metal wheel valve, 15mm dia brass nipple, 15mm dia nylon connection etc. including fixing the wash hand basin in the wall in position with pair of C.I.brackets with teak wood plugs and screws and giving necessary water supply connection and painting the brackets with two coats of paint over a priming coat of anti-corrosive paint including testing for leakage etc., complete complying with standard specification and as directed by the departmental officers.(The wash hand basin and specials should be got approved by the departmental officers before use on work)
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand of size 600x450mm x5.5mm thick with necessary plastic back, PVC frame with bottom stand of approved colour with brass screws, rawal plugs etc. complete complying with standard specification and as directed by the departmental officers. (The materials should be got approved by the departmental officers before use on works)
Supplying and fixing in position PVC Nahini trap of size 100x75mm with best pvc gratings of approved brand and quality with fixed over a bed of brick jelly lime concrete 1:2:5(one part of lime,two parts of sand and five parts of 40mm size brick jelly)and finished with cement Mortar 1:3(one cement and three sand)including dismantling masonry works wherever found necessary and making good the damaged portions to the original condition giving connections to the pipe etc., complete complying with standard specification and as directed by the departmental officers. (The PVC Nahini trap with grating should be got approved by the departmental officer before use on works).
Supplying, laying and jointing PVC soil / waste pipes of approved and best variety conforming to IS. Specification with ISI. mark of the following sizes including, cutting and threading of PVC Pipes, fixing specials but excluding cost of such specials but including fixing to wall with necessary teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in roof and making good the dismantled portion to original condition with necessary brick work and plastering wherever necessary with necessary scaffolding charges. The PVC Pipes should be got approved by the Departmental Officers before use on work. Below ground level.
75mm dia PVC soil pipe
110mm dia PVC soil pipe
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
110mm dia PVC door Tee (Single)
110mm dia PVC Bend
75mm dia PVC door Elbow
75mm dia PVC plain Bend
110mm dia PVC Cowl
75mm dia PVC Cowl
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs,UPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. For External Water supply arrangements. (Below Ground Level)
50mm dia UPVC pipe
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs,UPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. For External Water supply arrangements. (Above Ground Level)
40mm dia UPVC pipe
32mm dia UPVC pipe
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs,UPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. For Internal Water supply arrangements. (Above Ground Level)
25mm dia UPVC pipe
20 mm dia PVC pipe
Supplying and fixing in position of the following UPVC specials best approved quality conforming to ISS and providing leak proof joints with UPVC adhesive etc., including fixing to walls with necessary teak wood plugs screws etc., and giving connections to the UPVC pipe dismantling the brick masonry RCC floor or roof slab and redoing the disturbed portion to original conditions etc., complete complying with standard specifications. -The UPVC specials should be got approved from the Executive Engineer before use on works -.
50mm dia UPVC Union
40mm dia UPVC Union
32mm dia UPVC Union
25mm dia UPVC Union
50mm dia UPVC Elbow
40mm dia UPVC Elbow
32mm dia UPVC Elbow
25mm dia UPVC Elbow
20mm dia UPVC Elbow
40mm dia UPVC Hex Nipple
32mm dia UPVC Hex Nipple
25mm dia UPVC Hex Nipple
25 x 20mm dia UPVC Reducer Elbow
20 x 15mm dia UPVC Reducer Elbow
40mm dia UPVC Tee
32mm dia UPVC Tee
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
40 mm dia G.M Gate valve
32 mm dia G.M Wheel valve
25 mm dia G.M Wheel valve
Supplying and fixing in position 15mm dia Chromium Plated brass screw down tap (heavy type) of approved make conforming to ISS.and including cost of shellac, thread complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Departmental Officers before use on the work)
Providing Anti – termite treatment to soil adjacent and under building foundation, plinth periphery of the building by application of chemicals of IS 6313 part I to IV in stage to suit the progress of work consist as per the detailed specification as below (Measurements taken for the plinth area for the purpose of payment) including braking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport & storing etc., complete and as directed by the departmental officers.(The chemical should be got approved by Executive Engineer before use on work). Stage -1 : Spraying Anti –termite chemical solution for the foundation before laying concrete, in bottom and sides of foundation. Stage-2 : Spraying Anti –termite chemical solution to the grade beam level, spraying has to done for to grade beam brick masonry contact with the back fill earth. Stage-3 : Spraying Anti –termite chemical solution on the sand for the flooring before laying the flooring concrete. This treatment has to be carried out and sand filling by making holes with crow bar to a depth of 60cms and at 60cms intervals on both direction and at junction of wall and flooring throughout. Stage -4 : Spraying Anti –termite chemical solution alround building outside by making holes with crow bar before laying plinth protection and the holes to be close after the treatment.
Supplying and fixing Stainless steel health faucet of best quality with control valve etc., complete complying with standard specification and as directed by the departmental officers (The materials should be got approved by the Executive Engineer before use on works).
Construction of INSPECTION CHAMBER 600 x 600 x 600 mm clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five M sand] using best quality of Fly Ash bricks of size 230×110×70mm " with Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification.
Supplying and fixing of Reverse Osmosis Plant of capacity 250 litres per hour. The Reverse Osmosis plant is stainless steel skid mounted with the parts. Raw water from the water tank is fed in to Pressure sand filter by raw water feed pump. The Pressure sand filter consists of FRP Vessel, Multiport valve and filtration media of pebbles & sand. Raw water enters in to the top of vessel and percolate through filter media and the suspended particles traps in the filter media top. Filtered water flows through Activated carbon filter for removal of colour and organic particles present in the water.The water passes through 10, 5 Micron filter to ensure the fine filtration of feed water. Micron filter made of Polypropylene material and its housing also made of PP. This fine prefiltered water pumped in to RO membrane in the pressure of 10-12 kg/cm2 through high pressure pump.The RO membrane made of thin film composite polyamide and it pore size 0.0001 microns (pore size lesser than Bacteria and virus). After penetrating through this membrane the purified water is collected in the center of the membrane and the salt, bacteria are rejected from the membrane side way. This purified water is collected in to water storage tank for further distributions. The reject water from the RO plant will have a higher TDS and the water is suitable for external applications like sanitary applications, flushing lines, gardening, etc., and as directed by the departmental officers. The rate includes cost of plant, cost of storage tank, loading and unloading, transportation charges, electrification charges, all taxes and all other incidental charges etc., complete.
Paving the floor with pre polished concrete Hydraulically pressed Anti skid tiles (like Eurocon Tiles) 20mm thick in all floors set in cement mortar 1:3 (One cement and three sand), 20mm thick and pointing with the cement including adding suitable colouring pigments of match with colour of tiles and finishing and curing as directed by the departmental officers including cost of tiles, and all other materials, transportation charges and labour charges for laying of tiles as directed by the departmental officers complete complying with standard specification. (The tiles should be got approved by the departmental officers before use on work.)
Supply and installation of Anutone (or) Equivalent Brand of Acoustical False Ceiling of Sisoli Serene / Slate Spirts / Slate Polka Mineral Fibre/ GRG Core Ceiling Tiles of size 595 x 595 x 15mm having volume density 270 kgs / m3, weight 4kg / m2 which is suspended by using 0.3mm thick skelet trelis T15 metal grid system. The skelet trelis T15 metal grid system of 600 x 600mm module includes skelet WA15 W30 wall angle with unequal flanges of 15 / 19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the skelet MT15 W36 MainT with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres.Skelet CT15 W12 CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally skelet CT15 W06 CrossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15 W12 CrossT in direction parallel to the Main T15 to result in 600 x 600mm module. Sisoli Serene / Slate Spirts / Slate Polka of size 595 x 595 x 15mm shall be placed into the grid size of 600 x 600mm. The systems to achieve noise reduction coefficient not less than 0.5 NRC, so as to have an neat appearance as directed by the department offices. The cost includes, cost of material, cost of labour, Scaffolding, transportation, conveyance, etc., complying to standard specication.
Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish 1/3rd fixed glazing 2/3rd prelaminated board of Aluminium partition of size 2.70 mx 2.10 m.The outer frames Outer frame: 63.50x38x3mm@ 1.72 kg/m,Centre mullions: 63.50x38x3mm@ 1.55 kg/m,Alu. Clips: 17.27x17.15x1.50mm @ 0.175kg/mg/m for intermediate vertical mullion 90cm c/c. Horizontal mullion at 1.00m 2.10m covered with 4 mm thick plain glass with neccessary aluminium clips of size 17.27x17.15 x1.50mm @ 0.176kg/m and with required rubber beading etc., including necessary dismantling holes in RCC column,masonry wherever in necessary with power drills to the extent required and made good the damaged portion in good condition after fixing as directed by the departmental officers. All the aluminium sections should be anodised not less than 15 microns as ISI specification1868/1962 / and should be gotapproved by Executive Engineer before use.
Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish of single leaf door with half panelled with 12mm thick both side laminated particle board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section Vertical & Top rail: 50x44.45x2.50mm @ 1.292 kg/m ,Bottom rail: 100 x44.45 x 2.50mm@ 1.974 kg/m, Lock rail : 50x44.45x2.5mm @ 1.292 kg/m, Alu Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 Kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - 1 No., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 1No ., lock-1No., Door stopper with rubber bush including cost of materials labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beams, masonry with power drill wherever necessary and redoing the damaged portion to the original condition after fixing etc., complete. All the Alu. Section are to be anodised with matt finish under electricaly controlled conditions in accordance with IS 1868/1962 for an average anatic film thickness of 15 microns etc., complete.Aluminium sections,and furniture fittings shall be got approved by the Executive Engineer incharge.
Sub Total
G KUPPUSAMY
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .